海悟推出CFC冷冻水近端风墙空调,主打高密算力机房近端制冷

Haiwu launches CFC chilled-water near-end fan wall AC, cutting fan power 50% and cooling-source power 30%
海悟科技新闻T12026-09-08 · CN · 海悟科技 Hiwave
新品技术发布数据中心/IT散热
▾ 3 条同事件报道

情报详报

What happened Haiwu Technology (Haiwu), a Chinese thermal-management equipment supplier, announced on 8 September 2026 the launch of its CFC chilled-water near-end fan wall air conditioner, a terminal cooling unit aimed at high-density data centers, modular compute facilities and high-heat-density telecom and enterprise computer rooms. According to the company's announcement, the product uses a compact chassis that can be installed flush alongside server racks, creating a standardized hot/cold aisle containment arrangement without complex ceiling work or raised-floor modification. Haiwu positions the unit for new-build, retrofit and expansion projects, and says it supports high chilled-water supply temperatures, high airflow and a high sensible heat ratio to shorten cooling delivery distance. The announcement highlights four claimed capability areas: (1) full-redundancy design with dual-side maintenance access and hot-swappable redundant fans for non-stop servicing; (2) airflow-path optimization that the company says cuts fan power consumption by 50% and, through higher entering/leaving water temperatures that widen free-cooling availability, reduces cooling-source power consumption by 30%; (3) an intelligent control system with graphical interface, self-diagnosis, proactive alarms and multi-unit group control that can integrate with DCIM platforms to modulate fan speed and valve opening against live IT load; and (4) lifecycle sustainability measures including RoHS compliance and optional low-GWP refrigerant. Haiwu states the unit is suited to rack densities above 20 kW and to differentiated East Data West Computing nodes. ### Key figures - Fan power consumption reduction: 50% (company claim) - Cooling-source power consumption reduction: 30% (company claim) - Supported rack density: 20 kW+ high-density racks - Announcement date: 8 September 2026 - No specific figures disclosed for unit capacity, airflow, price, production volume, market share or delivery timeline. ### Why it matters to ebm-papst Haiwu is explicitly targeting the same high-density, low-PUE data center cooling segment where ebm-papst supplies fan and motor subsystems, and it is doing so with a near-end fan wall architecture that multiplies the number of fans per rack row rather than centralizing air handling. The claimed 50% fan power reduction is a direct competitive signal: if Haiwu achieves this through proprietary airflow-path design and its own fan selection, it could reduce the value ebm-papst captures per unit unless ebm-papst is the fan supplier or can match the efficiency claim with its own high-efficiency EC fan platforms. Assessment (inference): The near-end fan wall format is structurally fan-intensive, so even a modest share gain by Haiwu in Chinese hyperscale and modular projects would expand total fan content per megawatt of IT load, which is a volume opportunity for ebm-papst if it is designed in. Assessment (inference): Haiwu's emphasis on hot-swappable redundant fans, high-water-temperature operation and DCIM-linked group control maps closely to ebm-papst's strengths in EC fans, redundancy and intelligent controls, suggesting a partner-or-compete decision point rather than a purely defensive one. Assessment (inference): The explicit alignment with the East Data West Computing program indicates Haiwu is pursuing state-backed projects where local-content preference may disadvantage non-Chinese suppliers, so ebm-papst should treat this as a market-access signal as much as a product threat. Assessment (inference): Because no capacity, pricing or customer commitments were disclosed, the near-term competitive impact is uncertain; the more actionable signal is that Chinese chilled-water terminal cooling is converging on near-end, high-airflow, high-water-temperature designs, which should inform ebm-papst's roadmap for data center fan walls and its engagement with Chinese OEMs.

原文全文

原文 英文翻译
算力产业进入高密度、高能耗、高迭代的全新发展阶段,AI服务器、超算集群单机柜热负荷持续走高,传统远端制冷模式冷量损耗大、气流组织混乱、局部热点频发、运维成本居高不下,已难以适配新一代数据中心建设要求。面对“高密散热、低PUE、易运维、强可靠”的行业刚需,海悟重磅推出CFC冷冻水近端风墙空调,以机柜旁近端送风架构、超低能耗设计、全冗余可靠运行与AI智能群控能力,为中大型数据中心、模块化机房、高热密度算力场景,提供一套更节能、更稳定、更省心的现代化冷冻水温控解决方案。 场景革新:近端贴合部署,重构机房气流逻辑 海悟CFC冷冻水近端风墙空调采用紧凑型机身设计,占地面积小,可与机柜并列贴合安装,快速搭建标准化冷热隔离通道,彻底告别传统机房风道紊乱、冷热掺混问题。机组支持高水温运行策略,配合大风量、高显热比输出特性,大幅缩短冷量输送距离,换热效率大幅提升。无需复杂吊顶、无需架空地板改造,适配新建、改建、扩建各类算力机房场景,完美匹配当前数据中心高密度、模块化、快速交付的建设趋势。 产品广泛适用于中大型数据中心、模块化算力中心、高热密度通信机房、企业级计算机机房,是高密算力散热改造与新建项目的优选末端制冷方案。 四大核心亮点,解决机房制冷核心痛点 1. 全域无热点,全冗余设计保障业务永续 依托近端零距离制冷优势,冷量精准覆盖机柜热源,机房温度场均匀稳定,从根源消除高密度服务器局部过热、高温降频、突发宕机等风险。整机采用人性化双面维护结构,正面、背面均可快速检修,运维人员无需进入狭小通道,大幅提升作业效率。关键风机部件支持热插拔冗余维护,可实现不停机在线维保,彻底杜绝运维作业带来的业务中断风险,为金融、政务、医疗、交通等关键业务提供7×24小时不间断制冷保障。 2. 风阻极致优化,风机、冷源双向大幅节能 针对传统空调风机能耗高、冷源利用率低的短板,海悟CFC风墙空调完成双重能效突破。通过精细化流道仿真优化,整机风阻大幅降低,风机功耗降低50%;适配高进出水温运行模式,有效拓宽自然冷源适用区间,冷源侧功耗降低30%。 依托冷冻水系统天然优势,机组可联动干冷器、冷却塔,在春秋过渡季、冬季充分启用免费自然冷制冷,大幅减少压缩机机械制冷时长,持续压低机房PUE,帮助数据中心实现常态化超低能耗运行,有效降低年度电费与运营成本。 3. 智能自诊断+集群联调,实现无人化智慧运维 机组搭载新一代智能控制系统,配备可视化图形界面,运行参数、设备状态、故障信息一目了然。内置多重电气、水力、温度防护机制,具备实时监测、故障自诊断、异常主动告警能力,提前识别设备隐患,变被动抢修为主动预防。 支持多机组智能群控协同调优,可无缝对接DCIM基础设施管理平台,基于实时IT负载动态调节风机转速、水阀开度,自适应匹配机房冷热负荷变化,实现整层、整机房制冷系统能效最优,大幅减少人工干预,降低运维人力成本。 多维价值赋能,助力算力产业绿色升级 筑牢数字基建安全底座,实现资源集约利用 数据中心作为数字经济的核心基础设施,承载着社会关键领域核心数据与业务流转。海悟CFC冷冻水近端风墙空调以高可靠、高精度控温能力,规避高温引发的系统故障、数据丢失、服务中断,稳定社会数字化运行秩序。同时,高密散热能力支持单机柜功率大幅提升,同等建筑面积下算力产出更高,有效节约土地资源,契合资源节约型数据中心建设方向。优化静音风道设计,设备运行更平稳、噪音更低,有效改善机房运维环境,降低职业健康损耗。 全生命周期低碳运行,深度落地双碳战略 机房制冷能耗是数据中心节能降碳的核心抓手。海悟CFC风墙空调凭借高效换热结构、自然冷源最大化利用、AI智能能效调优三重技术加持,持续优化机房PUE指标,大幅降低制冷碳排放。产品严格遵循RoHS绿色制造标准,可选低GWP环保制冷剂,从研发、生产到运行、退役的全生命周期践行绿色低碳理念,助力数据中心从“高能耗”向“低耗绿色”全面转型。 支撑高密算力迭代,赋能国家级算力布局 面对AI大模型、云计算驱动的算力爆发,高热密度散热成为制约算力释放的关键瓶颈。海悟CFC冷冻水近端风墙空调凭借精准近端散热、大风量换热优势,轻松适配20kW+高密机柜散热需求,为高算力硬件稳定运行提供坚实保障。产品适配性极强,可灵活匹配“东数西算”工程差异化建设需求:东部节点适配高密度集约部署,西部节点最大化利用自然冷源节能降碳,助力全国算力资源统筹优化、高效协同发展。 结语 从散热安全、空间提效到能耗优化、智能运维,海悟CFC冷冻水近端风墙空调以近端精准制冷、双效节能、全冗余可靠、AI智慧管控四大核心优势,全面适配新时代数据中心绿色化、高密度、智能化发展趋势。未来,海悟将持续深耕数字基础设施温控赛道,以创新技术与成熟方案,持续为算力产业提质降本、低碳增效赋能,筑牢数字经济绿色发展底座。