What happened Hiwave (Haiwu Technology) announced the launch of its CRC in-row chilled-water precision air conditioner, a new-generation near-source cooling unit aimed at small and medium-sized data centers, modular computer rooms and high-density compute facilities. The announcement was published on 2026-09-21 on the company's news channel. According to the company, the CRC unit is deployed directly between server racks and uses a horizontal airflow pattern: cold air is supplied from the front of the cold aisle and return air is drawn from the rear of the hot aisle. This shortens the air path and targets server sensible heat directly, which Hiwave says eliminates hot/cold air mixing and airflow short-circuiting, evens out the room temperature field and removes local hot spots. The product's headline differentiator is that it requires no dedicated outdoor condensing unit. Instead it integrates with a centralized chilled-water system comprising chillers, pumps and chilled-water piping. Hiwave positions this as a solution to common retrofit constraints: insufficient outdoor unit space, roof load limits and difficult facade construction. Hiwave lists eight core capabilities: branded core components tested for high/low temperature, long-term load and start-stop endurance for 7x24 operation; EC centrifugal fans with stepless variable-frequency modulation that adjust airflow and cooling output to real-time IT load; a power-free wet-film humidifier; a full-cabinet straight-tube coil design with large heat-exchange area and low air resistance; a high return-air temperature design intended to exploit centralized cooling sources; dual-side (front and rear) full-service access with a pull-out electrical control box on half-cabinet models; flexible group control networking for multi-unit coordination and load balancing; and an optional electricity metering module for per-unit energy visibility. Target applications include small and medium data centers, modular data centers, cold/hot aisle retrofit projects, medium-to-high heat density telecom rooms and enterprise computer rooms, spanning carrier IDC, internet, financial securities, government and large enterprise data center new-build, expansion and upgrade scenarios. ### Key figures No specific figures disclosed. The announcement contains no capacity ratings (kW), airflow values, COP/EER or PUE figures, pricing, unit counts, delivery timelines, market share data or efficiency percentages. All performance claims are qualitative (for example "significantly lower energy consumption" and "significantly improved heat-exchange efficiency"). ### Why it matters to ebm-papst The CRC is an in-row chilled-water unit using EC centrifugal fans with stepless variable-frequency control, which places it in the same component category ebm-papst supplies for precision cooling and in-row/rack-level cooling applications. Hiwave is a Chinese thermal-management vendor targeting exactly the fast-growing small and mid-size, modular and retrofit data center segment where near-source cooling is displacing traditional room-level CRAC units. Assessment (inference): The most direct commercial angle is fan supply. A new in-row platform with EC variable-speed centrifugal fans represents a potential volume opportunity for ebm-papst or for its competitors, and Hiwave's emphasis on "branded core components" suggests it sources from established suppliers rather than in-house. Assessment (inference): The no-outdoor-unit architecture is a market signal that retrofit-constrained sites in China are a priority segment, since it removes the outdoor condenser, roof loading and facade work that often block room-level upgrades. Assessment (inference): Because the unit is designed around high return-air temperatures and centralized chilled water, fan selection will be driven by high-temperature, low-air-resistance operating points, which favors EC centrifugal designs with wide modulation range and low acoustic output. Assessment (inference): Competitive risk exists if Hiwave's EC fan demand is captured by local Chinese fan makers on price; the counter-position is efficiency, noise, reliability and lifetime cost in 7x24 duty. Assessment (inference): The absence of published capacity, efficiency or PUE figures means the competitive impact cannot be quantified from this announcement alone; ebm-papst should treat it as a segment signal and seek the unit's fan specification and supplier through channel or tender intelligence.
原文全文
原文
英文翻译
无外机极简部署,近端极致节能|海悟CRC列间级冷冻水精密空调 赋能中小型绿色算力机房
发布时间:2026-09-21
当下中小型数据中心、模块化机房、高密度算力机房建设与改造提速,传统房间级空调送风距离长、冷热风易短路、局部热点突出、整体能效偏低,同时大量存量机房存在外机安装空间不足、施工受限、改造难度大等现实痛点。在算力高密度升级与双碳节能的双重趋势下,机房温控亟需从“粗放制冷”向精准制冷、极简部署、智能降耗、低运维成本全面升级。
立足中小型算力机房真实工况与改造痛点,海悟推出CRC列间级冷冻水精密空调。作为新一代行间近端制冷设备,产品延续紧靠热源精准制冷优势,创新无需室外机极简部署方案,依托集中冷冻水系统架构,搭配高效换热、变频自适应送风、节能加湿、智能群控等核心能力,高效解决高密机房散热不均、能耗偏高、施工受限、运维繁琐等难题,全面助力绿色数据中心提质降本、低碳增效。
一、产品概述:列间近端制冷,适配受限场景高效落地
海悟CRC列间级冷冻水精密空调是专为高热密度机房打造的行间精密制冷设备,可与冷水机组、水泵、冷冻水管道组成成熟稳定的集中制冷系统。区别于常规空调,产品无需单独配置室外机,完美破解机房外机位不足、楼顶荷载受限、外立面施工困难等落地难题。
机组直接部署于机柜列间,采用冷通道前送风、热通道后回风的水平送风模式,紧贴热源、缩短送风路径,精准处理服务器设备显热,从根源杜绝冷热风掺混、气流短路问题,机房温度场更均匀,彻底消除局部热点,在保障业务稳定运行的同时,实现显着节能效果,适配机房长期低碳运营需求。
二、全场景适配,覆盖算力机房新建与改造
产品场景适配度极高,精准匹配中小型算力基础设施全生命周期建设需求,广泛应用于:中小型数据中心、模块化数据中心、机柜冷热通道改造项目、中高热密度通讯机房、企业计算机机房,全面适配运营商IDC、互联网机房、金融证券、政务单位、大中型企业数据中心等场景的新建、扩容与升级改造。
三、核心产品优势,八大硬核能力破解机房痛点
1. 大牌核心部件,整机稳定可靠、故障率低
整机核心零部件均甄选行业知名品牌,经过多轮高低温、长期负载、启停耐久测试,硬件品质扎实、抗衰减能力强,可从容应对7×24小时不间断运行工况,大幅降低设备故障概率与后期维保成本,为金融、政务等关键业务机房提供高可靠温控保障。
2. EC变频风机自适应,按需供冷更省电
搭载高性能EC离心风机,支持全程无级变频调节,可根据机房实时IT负载、环境温度动态自动调节风量与制冷输出,实现“负荷随动、按需制冷”。低功耗、低噪音、低震动运行特性,有效减少无效能耗输出,适配机房动态负载变化,长期节能收益可观。
3. 无功耗湿膜加湿,节能加湿双优
配备轻量化无功耗湿膜加湿组件,无需额外耗电即可实现快速、均匀加湿,相较传统加湿方式能耗更低、加湿更平稳。可精准平衡机房环境湿度,有效规避静电、设备受潮、元件老化等问题,保障精密IT设备长期稳定运行,适配高标准机房环境管控要求。
4. 满柜式一字型表冷器,大面积、低风阻、高效率
采用创新满柜式一字型表冷器设计,最大化利用整机空间拓展换热面积,搭配低风阻流道结构,风阻大幅降低、换热容量显着提升,冷量交换更充分。结合高回风温度优化设计,进一步释放集中冷源节能潜力,整机换热效率大幅升级,助力机房持续压低PUE。
5. 高回风工况设计,系统能效显着跃升
适配数据中心高回风运行工况,可充分利用环境温度特性,减少冷源系统负荷压力,最大化发挥集中冷冻水系统的节能优势,相较传统房间级空调,系统整体能耗更低、能效表现更优,适配绿色数据中心节能建设标准。
6. 双面全维运维,抽拉电控设计省时高效
采用正面+背面双面全维护结构,无死角检修空间,日常滤网、风机、管路维护便捷高效。半柜机型搭载可抽拉式电控箱,无需整机拆机即可完成电路检测、故障排查与部件保养,大幅缩短运维时长、降低人工成本,适配机房紧凑布局场景。
7. 灵活群控组网,机房能效智能统筹
支持多机组灵活群控组网,可实现多台设备协同联动、负载均衡、智能调度,根据机房整体冷热负荷自动分配制冷量,避免局部过载与能源浪费,实现机房全域能效最优,适配模块化、集群化机房的智能化管理需求。
8. 可选电量计量,支撑精细化能耗管理
可按需增配电量计量功能模块,精准统计单台设备运行能耗,实现能耗可视、可查、可追溯,助力机房完成节能考核、能耗分析与精细化能源管控,契合绿色数据中心标准化建设要求。
四、多维价值落地,赋能算力产业高质量发展
1. 社会价值:夯实数字基建,保障业务永续稳定
数据中心是数字经济、政务服务、金融通信、企业信息化的核心底座,机房温度不均、局部过热极易引发设备降频、业务卡顿、系统宕机,直接影响社会生产与公共服务秩序。海悟CRC列间冷冻水空调以近端精准制冷、全域均匀控温能力,彻底解决高密度机房热点难题,保障关键业务全年连续稳定运行。同时无外机轻量化部署模式,大幅降低老旧机房改造难度,盘活存量算力资源,提升机房空间利用率与基础设施集约化水平。
2. 低碳价值:全链路节能降耗,助力双碳落地
制冷能耗是数据中心能耗的核心构成,也是IDC降碳增效的关键突破口。海悟CRC依托EC变频按需制冷、低风阻高效换热、无功耗节能加湿、高水温节能工况、智能群控优化多重技术叠加,全方位降低机房制冷能耗,持续优化机房PUE水平,有效减少碳排放。通过最大化利用集中冷源、减少无效制冷损耗,实现设备全生命周期绿色低碳运行,助力中小型数据中心规模化完成节能降碳目标。
3. 数字经济赋能:支撑算力升级,加速算力网络建设
随着云计算、大数据、边缘计算持续普及,中小型机房算力密度持续提升,传统制冷方案难以匹配高密散热需求。海悟CRC列间空调凭借紧贴热源、极速换热、精准控温的优势,突破高密机房散热瓶颈,为算力硬件稳定运行提供坚实物理支撑。同时智能化群控、可视化运维、能耗精细化管理能力,推动机房从传统人工运维向数字化、无人化、智能化运维升级,降低算力基础设施运营成本,持续赋能全国一体化算力网络建设,助推数字经济高效绿色发展。
五、总结
无需外机、部署灵活、精准控温、极致节能、运维简便、智能可控,海悟CRC列间级冷冻水精密空调精准击中中小型数据中心与高密机房建设、改造核心痛点,以成熟的集中冷源架构与迭代升级的产品能力,平衡“建设成本、运行能耗、运维压力、安全稳定性”四大核心需求。未来,海悟将持续深耕算力温控领域,以绿色、智能、高效的温控技术,持续为数字基建升级、算力产业低碳转型赋能。
相关新闻更多
No outdoor unit, minimalist deployment, extreme near-end energy savings | Hiwave CRC in-row chilled-water precision air conditioner empowers small and medium-sized green compute rooms
Published: 2026-09-21
At present, the construction and renovation of small and medium-sized data centers, modular computer rooms and high-density compute rooms are accelerating. Traditional room-level air conditioners have long air supply distances, are prone to cold/hot air short-circuiting, prominent local hot spots and relatively low overall energy efficiency. At the same time, a large number of existing computer rooms face practical pain points such as insufficient outdoor unit installation space, construction restrictions and high renovation difficulty. Under the dual trends of high-density compute upgrades and dual-carbon energy saving, room temperature control urgently needs a comprehensive upgrade from "extensive cooling" to precise cooling, minimalist deployment, intelligent energy reduction and low O&M cost.
Based on the real operating conditions and renovation pain points of small and medium-sized compute rooms, Hiwave has launched the CRC in-row chilled-water precision air conditioner. As a new-generation inter-row near-end cooling device, the product continues the advantage of precise cooling close to the heat source, innovates a minimalist deployment solution requiring no outdoor unit, and relies on a centralized chilled-water system architecture, combined with core capabilities such as high-efficiency heat exchange, variable-frequency adaptive air supply, energy-saving humidification and intelligent group control, to efficiently solve the problems of uneven heat dissipation, high energy consumption, construction restrictions and cumbersome O&M in high-density computer rooms, comprehensively helping green data centers improve quality, reduce costs and increase efficiency with low carbon.
I. Product overview: in-row near-end cooling, efficiently implemented in constrained scenarios
Hiwave CRC in-row chilled-water precision air conditioner is an inter-row precision cooling device specially built for high heat density computer rooms. It can form a mature and stable centralized cooling system with chillers, pumps and chilled-water pipes. Unlike conventional air conditioners, the product requires no separately configured outdoor unit, perfectly solving implementation difficulties such as insufficient outdoor unit positions, limited roof load and difficult facade construction.
The unit is deployed directly between cabinet rows and adopts a horizontal air supply mode with front supply from the cold aisle and rear return from the hot aisle. It stays close to the heat source, shortens the air supply path, precisely handles the sensible heat of server equipment, fundamentally eliminates cold/hot air mixing and airflow short-circuiting, makes the room temperature field more uniform, thoroughly eliminates local hot spots, and while ensuring stable business operation, achieves significant energy-saving effects, adapting to the long-term low-carbon operation needs of computer rooms.
II. Full-scenario adaptation, covering new construction and renovation of compute rooms
The product has extremely high scenario adaptability and precisely matches the full life-cycle construction needs of small and medium-sized compute infrastructure. It is widely used in: small and medium-sized data centers, modular data centers, cabinet cold/hot aisle renovation projects, medium and high heat density communication rooms, and enterprise computer rooms, fully adapting to new construction, expansion and upgrade renovation scenarios such as carrier IDC, internet computer rooms, finance and securities, government units, and large and medium-sized enterprise data centers.
III. Core product advantages: eight hardcore capabilities solving computer room pain points
1. Branded core components, stable and reliable whole machine with low failure rate
The core components of the whole machine are all selected from well-known industry brands. After multiple rounds of high and low temperature, long-term load, and start-stop endurance tests, the hardware quality is solid and the anti-degradation capability is strong. It can calmly cope with 7x24 uninterrupted operation conditions, greatly reducing the probability of equipment failure and later maintenance costs, and providing highly reliable temperature control guarantees for key business computer rooms such as finance and government affairs.
2. EC variable-frequency fans adapt automatically, supplying cooling on demand and saving more electricity
Equipped with high-performance EC centrifugal fans, it supports stepless variable-frequency adjustment throughout the whole process, and can dynamically and automatically adjust air volume and cooling output according to the real-time IT load and ambient temperature of the computer room, realizing "load following, cooling on demand." Its low power consumption, low noise and low vibration operating characteristics effectively reduce ineffective energy output, adapt to dynamic load changes in the computer room, and deliver considerable long-term energy-saving returns.
3. Power-free wet-film humidification, excellent in both energy saving and humidification
Equipped with a lightweight power-free wet-film humidification component, it can achieve fast and uniform humidification without additional power consumption. Compared with traditional humidification methods, energy consumption is lower and humidification is more stable. It can precisely balance the ambient humidity of the computer room, effectively avoid problems such as static electricity, equipment dampness and component aging, and guarantee the long-term stable operation of precision IT equipment, adapting to the environmental control requirements of high-standard computer rooms.
4. Full-cabinet straight-tube coil, large area, low air resistance, high efficiency
It adopts an innovative full-cabinet straight-tube coil design, maximizing the use of the whole machine space to expand the heat exchange area. Combined with a low-air-resistance flow channel structure, air resistance is greatly reduced and heat exchange capacity is significantly improved, making cooling exchange more sufficient. Combined with a high return-air temperature optimization design, it further releases the energy-saving potential of the centralized cooling source, greatly upgrades the heat exchange efficiency of the whole machine, and helps computer rooms continuously lower PUE.
5. High return-air condition design, system energy efficiency significantly improved
It adapts to the high return-air operating conditions of data centers, can make full use of ambient temperature characteristics, reduce the load pressure of the cooling source system, and maximize the energy-saving advantages of the centralized chilled-water system. Compared with traditional room-level air conditioners, the overall system energy consumption is lower and energy efficiency performance is better, adapting to the energy-saving construction standards of green data centers.
6. Dual-side full-dimensional O&M, pull-out electrical control design saves time and improves efficiency
It adopts a front plus rear dual-side full-maintenance structure with no-dead-angle inspection space, making daily maintenance of filters, fans and piping convenient and efficient. Half-cabinet models are equipped with a pull-out electrical control box, allowing circuit inspection, fault troubleshooting and component maintenance without dismantling the whole machine, greatly shortening O&M time and reducing labor costs, adapting to compact computer room layout scenarios.
7. Flexible group control networking, intelligent overall planning of computer room energy efficiency
It supports flexible group control networking of multiple units, enabling coordinated linkage, load balancing and intelligent scheduling of multiple devices, automatically allocating cooling capacity according to the overall cold and hot load of the computer room, avoiding local overload and energy waste, achieving optimal energy efficiency across the whole computer room, and adapting to the intelligent management needs of modular and clustered computer rooms.
8. Optional electricity metering, supporting refined energy consumption management
An electricity metering function module can be added as needed to precisely measure the operating energy consumption of a single device, making energy consumption visible, queryable and traceable, helping computer rooms complete energy-saving assessments, energy consumption analysis and refined energy management, and meeting the standardized construction requirements of green data centers.
IV. Multi-dimensional value implementation, empowering high-quality development of the compute industry
1. Social value: consolidating digital infrastructure, ensuring continuous and stable business
Data centers are the core foundation of the digital economy, government services, financial communications and enterprise informatization. Uneven room temperatures and local overheating can easily cause equipment frequency reduction, business lag and system downtime, directly affecting social production and public service order. With near-end precise cooling and full-domain uniform temperature control capabilities, the Hiwave CRC in-row chilled-water air conditioner thoroughly solves the hot spot problem of high-density computer rooms and guarantees continuous and stable operation of key businesses throughout the year. At the same time, the no-outdoor-unit lightweight deployment mode greatly reduces the renovation difficulty of old computer rooms, revitalizes existing compute resources, and improves computer room space utilization and infrastructure intensification level.
2. Low-carbon value: full-chain energy saving, helping dual-carbon implementation
Cooling energy consumption is a core component of data center energy consumption and a key breakthrough for IDC carbon reduction and efficiency improvement. Relying on the superposition of multiple technologies such as EC variable-frequency on-demand cooling, low-air-resistance high-efficiency heat exchange, power-free energy-saving humidification, high water temperature energy-saving conditions and intelligent group control optimization, the Hiwave CRC comprehensively reduces computer room cooling energy consumption, continuously optimizes computer room PUE level, and effectively reduces carbon emissions. By maximizing the use of centralized cooling sources and reducing ineffective cooling losses, it realizes green and low-carbon operation throughout the equipment life cycle, helping small and medium-sized data centers complete energy-saving and carbon-reduction goals at scale.
3. Digital economy empowerment: supporting compute upgrades, accelerating compute network construction
With the continuous popularization of cloud computing, big data and edge computing, the compute density of small and medium-sized computer rooms continues to rise, and traditional cooling solutions are difficult to match high-density heat dissipation needs. With the advantages of staying close to the heat source, extremely fast heat exchange and precise temperature control, the Hiwave CRC in-row air conditioner breaks through the heat dissipation bottleneck of high-density computer rooms and provides solid physical support for the stable operation of compute hardware. At the same time, intelligent group control, visualized O&M and refined energy management capabilities drive computer rooms to upgrade from traditional manual O&M to digital, unmanned and intelligent O&M, reduce the operating cost of compute infrastructure, continuously empower the construction of the national integrated compute network, and boost the efficient and green development of the digital economy.
V. Summary
No outdoor unit, flexible deployment, precise temperature control, extreme energy saving, simple O&M and intelligent controllability: the Hiwave CRC in-row chilled-water precision air conditioner precisely hits the core pain points of construction and renovation of small and medium-sized data centers and high-density computer rooms. With a mature centralized cooling source architecture and iteratively upgraded product capabilities, it balances the four core needs of "construction cost, operating energy consumption, O&M pressure and safety and stability." In the future, Hiwave will continue to deepen its work in the field of compute temperature control, and continue to empower the upgrading of digital infrastructure and the low-carbon transformation of the compute industry with green, intelligent and efficient temperature control technologies.
Related news More