聚合·天加T22026-09-18 · CN · 天加环境 TICA · NVIDIA 英伟达 · Smardt 无油冷水机组
新品技术发布数据中心/IT散热

情报详报

What happened TICA (Nanjing TICA Climate Solutions) published the final installment of its white paper series on liquid cooling for the high-density AI computing era, released via an aggregated company channel dated 18 September 2026. The first two installments covered rising server heat-removal demand and industry pain points, and the evolution of AIDC HVAC architectures; this closing part presents TICA's integrated AIDC HVAC solution for ultra-high-density computing scenarios, positioned around full-chain in-house development and manufacturing. The solution spans a primary-side cooling source, a secondary-side liquid cooling unit, and a secondary-side air-assisted terminal. On the primary side, TICA offers magnetic-bearing chillers and dry coolers. TICA states it wholly acquired Smardt, a leading global magnetic-bearing chiller brand, and that Smardt oil-free magnetic-bearing chillers deliver zero friction, zero oil and zero degradation, can run stably down to 2% load, and reach a part-load COP of up to 32.1; a "Smart Lift" function supports stable operation with high chilled-water supply temperatures. Dry coolers target "East Data West Computing" hub nodes and favorable climates, with free cooling exceeding eight months per year in northern China and spray/wet-film pre-cooling in hot-humid southern regions; chillers shut off entirely when outdoor dry-bulb temperature falls below 27.5 C, with supply/return water around 25/35 C. On the secondary side, TICA has developed high-power liquid cooling CDUs for 130-200 kW racks, matched to NVIDIA GB200 NVL72 and GB300 NVL72 cabinets, plus dual-source air walls sharing the same primary-side cooling water for cabinet air cooling loads. ### Key figures - Part-load COP of Smardt magnetic-bearing chillers: up to 32.1 - Minimum stable load: 2% - Energy saving versus traditional computer rooms via OPTSEEK platform: more than 40% - Free cooling duration in northern China: more than 8 months per year - Dry cooler changeover threshold: outdoor dry-bulb below 27.5 C; supply/return water about 25/35 C - CDU for GB200 NVL72: rated heat exchange capacity 1350 kW; secondary flow about 11.6 m3/h at 10 C supply-return differential; covers 115 kW liquid cooling load - CDU for GB300 NVL72: 1500 kW capacity; flow about 12.9 m3/h at 10 C differential; addresses 121 kW continuous liquid cooling load plus transient peaks - Rack power range addressed: 130-200 kW - Air cooling loads: GB200 17 kW, GB300 21 kW - Air wall supply air temperature: 18-27 C (recommended 22-26 C) - EC fan energy saving versus AC fans: 25%-40%; fan noise as low as about 60 dB(A) - Claimed efficiency gain of GB200 NVL72 liquid cooling versus traditional air cooling: 25x - WUE of dry-mode-first strategy: approximately 0 ### Why it matters to ebm-papst TICA is positioning itself as a full-stack AIDC thermal management supplier, from primary cooling source through CDU to rack-level air terminals, explicitly aligned to NVIDIA GB200 and GB300 NVL72 platforms. This is a competitive signal in the data center cooling value chain: a Chinese HVAC manufacturer is consolidating chiller, CDU and air-side content under one in-house portfolio, which could reduce the number of separate component suppliers per project. Assessment (inference): The air-side portion of TICA's architecture, specifically the dual-source air walls using EC variable-frequency fans, is the most directly relevant element for ebm-papst, since EC fans are a core ebm-papst product category and TICA does not state which fan supplier it uses. Assessment (inference): TICA's stated 25%-40% EC-versus-AC fan energy saving and roughly 60 dB(A) noise level are the performance benchmarks ebm-papst would need to match or beat in any bid for this class of air wall. Assessment (inference): The emphasis on high chilled-water temperatures (25 C supply) and extended free cooling favors fan-heavy dry cooler and air wall designs, which could expand the addressable fan content per megawatt of IT load. Assessment (inference): Because TICA claims full-chain self-development and self-production, ebm-papst should treat TICA primarily as a potential competitor at system level and as a possible OEM customer only for components TICA does not manufacture itself; the white paper does not disclose TICA's fan sourcing, so this remains uncertain.

原文全文

原文 英文翻译
天加环境白皮书致力于在高密AI时代提供液冷解决方案。在第一篇内容中我们指出了AI时代服务器散热需求的增长与行业痛点;第二篇中,我们探讨了AIDC暖通架构最新演进方向;本篇将站在前文之上,给出天加面向超高密算力场景的AIDC暖通整体解决方案,以全链条自研自产能力回应AI算力时代的散热难题。 AIDC全链路热管理方案 天加数据中心全链条整体解决方案 全维度适配GB200/GB300服务器 针对英伟达两款超高功耗整机柜差异化散热需求,天加依托自研磁悬浮冷机、标准化液冷CDU、双冷源末端、智慧能碳管控平台,打造一次侧同源冷源+二次侧风液双回路一体化暖通体系,一套冷源同时支撑GB200/GB300风冷包间、IT包间与超核包间,完美平衡新建智算中心、存量机房改造两类场景需求。 一次侧冷源系统 磁悬浮主机&干冷器,适配高温液冷供液需求 1.磁悬浮冷水机组(核心冷源) 天加全资并购全球头部磁悬浮品牌SMARDT,磁悬浮解决方案作为一次侧冷源系统,正深度适配AIDC高温液冷供液需求,为单柜功率突破MW级的高密度算力场景提供可靠冷源保障。SMARDT无油磁悬浮冷水机组,采用磁悬浮轴承技术实现0摩擦、0润滑油、0衰减的运行特性。该机组具备低至2%负荷率仍可稳定运行的超宽调节能力,并可在低环温、高冷冻水温工况下保持高效,部分负荷COP最高可达32.1。同时,机组特有的“Smart Lift”功能可确保高温冷冻水供水条件下的稳定运行,省略复杂的冷却水旁通设计,直接匹配液冷CDU对中高温冷源的需求。 在系统层面,天加通过风液同源架构融合磁悬浮高效主机与液冷CDU,既可兼容传统风冷,也能平滑适配新一代液冷散热。依托OPTSEEK智慧物联平台实现AI主动寻优与能效可视化,较传统机房节能40%以上。该方案已在多个超大规模智算项目。 2.干冷器(自然冷源) 干冷器自然冷源系统是针对“东数西算”枢纽节点及气候适宜地区设计的高效冷却方案。在北方年均干湿球温差较大的区域,该系统全年自然冷却时长可超过8个月,有效降低机械制冷能耗;在南方湿热地区,则通过喷淋/湿膜预冷技术实现等焓降温,将干球温度降至湿球温度附近,进一步延长自然冷却可用时段。 系统控制策略上,当室外干球温度低于27.5℃时,冷水机组完全关闭,由干冷器直接为液冷CDU提供一次侧冷冻水,供回水温度可维持在25/35℃左右,满足GB300集群等高温液冷需求。机组采用全变频EC风机,AI控制器依据室外温湿度变化及机柜实时负载波动,动态调节风机转速与喷淋量,确保冷水出水温度稳定可控,秒级响应瞬时热冲击,解决AI训练任务负载剧烈波动带来的供冷滞后难题。 此外,干模式优先策略大幅减少喷淋用水,WUE≈0,实现极致节水与高效自然冷却的平衡。该系统结构简洁、维护量低,已在海内外多个大型智算中心中复制推广。 二次侧液冷核心单元 天加适配NVL72机柜专用CDU冷却分配系统 CDU是连接一次侧冷源与GB200/GB300液冷机柜的核心枢纽,天加基于行业主流设计标准,自主研发适配130~200kW超高密机柜的大功率液冷CDU,完美匹配两款整机柜流量、压力、温度需求: 1. 分级制冷容量精准匹配 ⑴ 适配GB200 NVL72机型:CDU额定换热容量1350kW,二次侧额定流量匹配低温差高效换热(如供回液温差10℃工况,流量约11.6m³/h),精准覆盖115kW液冷热负荷,并预留峰值冗余; ⑵ 适配GB300 NVL72机型:升级1500kW大容量CDU,流量适配更高负载(供回液温差10℃工况,流量约12.9m³/h),应对121kW持续液冷负荷与瞬时峰值发热; 2. 安全冗余设计适配7×24小时算力运行 内部板式换热器隔离一次侧冷冻水与服务器二次去离子回路,杜绝市政冷源杂质进入芯片微通道冷板;双变频冗余泵组,单泵故障另一台自动100%负荷运行;内置高精度温度、压力、电导率传感器,实时监测冷却液漏液、水质劣化,一旦异常联动服务器预警,避免GPU过热宕机; 3. 高温换热节能特性 支持25℃标准供液,并可实现宽区间弹性调节。更高的供液温度大幅延长了自然冷源的可用时长,减少了对机械制冷的依赖。相比传统风冷架构,GB200 NVL72液冷系统可实现25倍的能效提升,显著降低数据中心的冷却能耗与碳足迹 二次侧风冷辅助末端 双冷源风墙匹配机柜风冷散热需求 GB200风冷负荷17kW、GB300风冷负荷21kW,天加双冷源风墙作为机房辅助散热末端,与液冷系统共用同一套一次侧冷却水,实现冷塔同源架构: 1、双盘管结构: 预冷自然盘管+机械压缩制冷盘管两级水路,大幅延长自然冷却运行时长,显著降低全年压缩机能耗。低负载/低温环境工况仅自然冷却盘管运行,室外冷源冷水通入自然冷却盘管,利用室外免费冷源完成热量置换,压缩机、冷媒系统完全停机;中高负载/高温环境工况,启动压缩机,热风先经自然冷盘管预降温,再通过压缩机制冷盘管深度冷却,双盘管叠加换热容量,补足高热负载所需冷量,稳定控制机房进风温度。 2、精准控温: 风墙出风温度严格控制在18~27℃(推荐运行区间22~26℃),确保每台GPU获得设计工况的进风温度,有效打破高密度部署中的“热串联效应”,避免局部热点导致GPU降频,保障AI集群持续满负荷运行。 3、静音低耗: 采用EC变频风机,相较传统AC风机,在不同工况下可降低25%~40% 的风机能耗。风机本体噪音可低至60dB(A) 左右,显著改善运维工作环境。 天加作为AIDC智算中心热管理专家,为 GB200/GB300 超高密算力构筑起从冷源到机柜的坚实底座。这不仅是散热技术的代际跃迁,更是对 "算力即生产力" 时代命题的深度回应 —— 冷却,已成为 AI 规模落地不可替代的关键基础设施。 面向未来,天加将持续深耕高密算力散热核心技术,以自研部件筑牢自主可控的产业韧性,以智慧能碳管控驱动极致能效与绿色运营,让每一度电都转化为澎湃算力。