海悟将亮相2026 CDCC数据中心标准论坛,聚焦液冷与预制化冷却体系升级

Hiwave to host AIDC full-chain cooling session at CDCC Data Center Standards Forum in Beijing on Nov 19
海悟科技新闻T12026-11-17 · CN · 海悟科技 Hiwave
数据中心/IT散热新品技术发布商用暖通

情报详报

What happened Hiwave, a Chinese data center cooling solutions provider, announced it will host a dedicated session on its AIDC full-chain cooling solutions at the 2026 CDCC Data Center Standards Forum, to be held on November 19, 2026 at the China National Convention Center in Beijing. The session, themed "Driving Change Toward Practice, Full-Chain Intelligent Cooling," will be held at booth 311B Hall T6. According to the announcement, Hiwave will present its system-level thinking and engineering practice for next-generation computing infrastructure, covering AIDC cooling technology trends, liquid cooling technology evolution, and the differentiated implementation of prefabricated cooling delivery. The announcement frames AIDC cooling selection as a multi-variable system decision rather than a simple liquid-versus-air replacement. Hiwave identifies six interrelated factors shaping cooling technology selection and deployment: policy and standards, climate and water resources, building form, customer requirements, TCO, and construction and O&M. On liquid cooling, the company highlights three focus areas: full-server liquid cooling moving from localized component cooling toward system-level thermal management; cold plate evolution from single-phase toward two-phase cooling; and CDU upgrades toward larger capacity, higher adaptability, modularity and intelligence. On delivery, Hiwave promotes prefabrication, modularization and productization to shift engineering work from on-site integration to factory prefabrication and standardized delivery, while retaining differentiated cold source configurations including cooling towers, dry coolers and high-temperature chillers to suit local conditions. ### Key figures - Event date: November 19, 2026 - Venue: China National Convention Center, Beijing - Booth: 311B Hall T6 - Six key variables identified as shaping AIDC cooling selection: policy and standards, climate and water resources, building form, customer requirements, TCO, and construction and O&M - Three liquid cooling focus areas: full-server liquid cooling, cold plate evolution (single-phase to two-phase), CDU capability upgrades - Fast delivery requirements cited: T+3/T+4 - Three cold source types cited: cooling towers, dry coolers, high-temperature chillers - No specific financial, capacity, market share or investment figures disclosed. ### Why it matters to ebm-papst This event is a market signal that Chinese AIDC cooling discussions are shifting from component-level performance toward system-level, full-chain thermal management, with liquid cooling and prefabricated delivery positioned as the main upgrade paths. For ebm-papst, a supplier of fans and motors for cooling equipment, the framing matters because air cooling is explicitly described as complementary rather than obsolete: Hiwave states that air and liquid cooling can be flexibly combined into hybrid air-liquid configurations depending on server configuration, auxiliary component cooling needs and room conditions. This preserves demand for high-efficiency fans and motors in CDUs, chillers, dry coolers, cooling towers and hybrid systems. Assessment (inference): Hiwave's emphasis on prefabrication, modularization and standardized delivery could favor suppliers that can offer standardized, factory-integrated fan and motor subassemblies with predictable specifications, rather than purely customized on-site solutions. Assessment (inference): The explicit focus on CDU capacity growth, adaptability and intelligence suggests growing demand for fans and motors in CDU heat exchange and flow management, an addressable opportunity for ebm-papst. Assessment (inference): The six-variable framework, particularly climate and water resources plus TCO, indicates that dry coolers and high-temperature chillers will remain relevant in northern and water-constrained regions, sustaining air-movement component demand alongside liquid cooling growth. Assessment (inference): As a Chinese domestic cooling player promoting system-level solutions, Hiwave could strengthen local competitors' integration capabilities, so ebm-papst should monitor whether Hiwave's standardized platforms lock in component specifications early in design cycles.

原文全文

原文 英文翻译
算力持续跃迁,冷却体系如何与之同行? 随着人工智能、大模型及高性能计算快速发展,数据中心正加速迈向高密度、高功率与规模化部署的新阶段。单柜功耗持续突破,算力密度不断攀升,传统制冷架构面临新的散热挑战。与此同时,能源效率、建设周期、资源利用与长期运营成本,也成为下一代算力基础设施建设必须统筹考量的重要因素。 从液冷技术加速演进,到预制化交付模式逐步成熟,AIDC冷却系统正在经历从单一设备优化向系统级协同升级的深刻变革。 然而,液冷是否意味着所有场景都要全面替代风冷?不同地域、不同规模的智算中心,应该如何选择冷源配置?面对快速交付需求,如何让先进冷却技术真正实现规模化落地? 技术路线需要因需而定,工程交付需要标准先行。 11月19日,2026 CDCC数据中心标准论坛大会将在北京国家会议中心举行。海悟将以「驭变向实 全链智冷」为主题,举办海悟AIDC全链路解决方案实践专场,围绕AIDC冷却技术发展趋势、液冷技术演进与预制化差异落地,分享面向下一代算力基础设施的系统思考与工程实践,探索高效、可靠、绿色的冷却体系升级路径。 一、六大变量交织,AIDC冷却技术进入系统决策时代 AIDC冷却技术的升级,并不是简单地用液冷替代风冷,也不是单纯追求更高规格的制冷设备,而是需要结合项目条件,对技术路线、系统架构和全生命周期成本进行综合决策。 海悟认为,影响AIDC冷却技术选型与落地的关键因素,主要集中在六个维度: 政策标准: 随着数据中心绿色低碳发展要求持续深化,能效指标、建设规范及相关技术标准不断完善,推动冷却系统向高能效、标准化方向发展。 气候水资源: 不同地域的气候条件、自然冷源利用条件及水资源禀赋存在差异,直接影响冷源形式、系统配置与运行策略。 建筑形式: 数据中心的建筑结构、空间布局、承重条件及机电空间,决定冷却设备的部署方式与系统集成路径。 客户需求: 不同客户在算力密度、业务连续性、扩容需求及建设周期方面存在差异,需要匹配不同的冷却架构与可靠性设计。 TCO成本: 冷却系统不能只关注初始设备投资,还需综合考虑建设投入、能源消耗、水资源使用、运维管理及未来升级改造成本。 施工运维: 现场施工条件、工程组织能力、运维水平与后期维护便利性,同样决定技术方案能否真正落地。 六大变量相互关联,共同影响冷却技术路线的选择。 这意味着,未来AIDC冷却系统的竞争,不再是单一设备性能的竞争,而是基于场景认知、系统设计、资源配置与全生命周期成本管理的综合竞争。 二、液冷主导演进,构建面向高密算力的确定性散热能力 随着GPU算力持续增长,传统风冷在部分高功率密度场景下逐渐面临散热能力与空间布局的限制。液冷凭借更高效的热传递能力,正成为下一代高密度算力基础设施的重要技术方向。 但液冷技术并非单一设备的升级,而是涉及服务器、冷却液、CDU、输配管网、冷源及控制系统的整体协同。 围绕液冷技术的发展趋势,海悟重点关注三个方向: 01 服务器全液冷:从局部散热走向系统级热管理 随着芯片功率密度持续提升,液冷技术正从局部关键器件散热向更大范围的服务器液冷化发展。 通过优化服务器内部热管理架构,让液冷系统更直接地承担高热流密度器件的散热需求,提升高密度算力场景下的热管理能力。 同时,风冷与液冷并非简单的替代关系,而是可以根据服务器配置、辅助器件散热需求及机房条件进行灵活组合,形成适配不同算力架构的风液融合方案。 02 冷板技术演进:从单相到两相,拓展液冷技术边界 冷板式液冷是当前数据中心液冷应用的重要技术路线。 随着芯片热设计功耗持续提升,冷板液冷技术也在不断演进,从单相冷却向两相冷却等技术方向探索,以适应更高热流密度下的散热需求。 不同技术路线在系统复杂度、介质特性、运行控制及工程适配方面各有特点,需要结合服务器架构、应用环境和全生命周期成本进行综合评估。 03 CDU能力升级:大容量、高适配,强化系统支撑 CDU作为液冷系统中连接一次侧冷源与二次侧IT设备的重要环节,其换热能力、流量控制、冗余设计及运行可靠性,直接影响液冷系统整体表现。 面向高密度算力需求,CDU正朝着大容量、高适配、模块化及智能化方向发展。 通过优化液冷系统的流量分配、温度控制与运行管理,提升冷却系统对不同服务器配置、不同机柜功率及未来算力架构的适配能力。 从服务器液冷化到冷板技术演进,再到CDU系统能力升级,液冷正在推动数据中心散热从局部优化走向全链路热管理。 三、预制化与差异化并行,让先进冷却技术真正落地 如果说液冷解决的是高密算力的散热问题,那么预制化解决的就是先进冷却系统如何高效建设、规模复制与快速交付的问题。 面对AIDC项目日益紧迫的建设周期,T+3/T+4等快速交付需求,对传统现场施工模式提出了更高挑战。冷源设备、输配管网、CDU及末端系统涉及多个专业环节,如果仍然依赖分散采购、现场集成和逐项调试,容易增加工程协同复杂度,影响整体交付效率。 海悟以预制化、模块化、产品化为重要方向,推动冷却系统从现场工程集成向工厂预制与标准化交付转变。 通过标准化设计、模块化组合、工厂预制与系统测试,将更多工程环节前置至工厂,提升系统集成效率与交付确定性。 与此同时,预制化并不意味着所有项目采用完全相同的冷却配置。 不同地域、不同建筑条件及不同算力规模,对冷源设备的选择仍然存在差异。海悟强调因地制宜,通过多元冷源矩阵与模块化配置,实现标准化交付与差异化应用的协同。 冷却塔: 结合当地气候及水资源条件,适配相应冷却架构与运行策略。 干冷器: 充分考虑室外气象条件与自然冷源利用潜力,优化系统运行方式。 高温冷水机组: 根据末端供水温度、负荷需求及系统能效要求,进行合理配置。 通过不同冷源设备的组合与协同,兼顾项目建设条件、运行效率及长期运营成本。 让冷却系统既具备标准化、模块化的交付能力,又保留面向不同应用场景的灵活适配空间。 四、从技术升级到绿色发展,构建可持续算力基础设施 算力规模持续增长,意味着数字基础设施需要消耗更多能源与资源。如何在保障算力供给的同时,提升能源利用效率、合理配置水资源、降低全生命周期运营成本,已经成为数据中心绿色发展的重要课题。 AIDC冷却技术的升级,不应只关注短期散热性能,更应从建设、运行、维护与升级等全生命周期维度进行统筹。 液冷技术的发展,为高密度算力提供了更加适配的热管理路径;预制化与模块化交付,有助于减少现场重复作业、提升工程组织效率;多元冷源与差异化配置,则为不同地域和资源条件下的数据中心提供更灵活的节能优化空间。 三者协同,推动冷却系统从单点技术创新走向系统级能效优化,从一次性工程建设走向标准化、可复制的基础设施交付。 面向数字经济高质量发展,海悟持续围绕全栈液冷、风液融合、多元冷源协同与预制化集成深化技术创新,推动冷却系统与算力基础设施深度融合。 让技术路线更加确定,让工程交付更加高效,让能源利用更加集约。 11月19日,2026 CDCC数据中心标准论坛大会,海悟将围绕AIDC冷却技术的确定性升级,分享液冷技术演进与预制化差异落地的系统实践,与行业伙伴共同探讨下一代绿色算力基础设施的发展方向。 未来,海悟将继续以系统级解决方案为支撑,以标准化、预制化为交付保障,推动数据中心冷却技术向高效、可靠、灵活与可持续方向发展,为数字经济基础设施建设贡献专业力量。 2026 CDCC数据中心标准论坛大会 驭变向实 · 全链智冷 海悟AIDC全链路解决方案实践专场 时间:2026年11月19日 地点:北京·国家会议中心 展位:311B厅 T6 冷却技术如何确定性升级?液冷主导,还是预制落地? 海悟邀您相聚北京,共探液冷技术演进与预制化规模落地新路径,共筑绿色、高效、可靠的算力基础设施新未来。