# Hiwave to host AIDC full-chain cooling session at CDCC Data Center Standards Forum in Beijing on Nov 19

- Source: Hiwave News (T1)
- Published: 2026-11-17
- Score: 63.0
- Tags: Datacenter, Product launch, HVAC
- Companies: Hiwave
- Original: https://www.haiwu.com/news/dynamic/2198.html

## Intelligence brief

### What happened Hiwave, a Chinese data center cooling solutions provider, announced it will host a dedicated session on its AIDC full-chain cooling solutions at the 2026 CDCC Data Center Standards Forum, to be held on November 19, 2026 at the China National Convention Center in Beijing. The session, themed "Driving Change Toward Practice, Full-Chain Intelligent Cooling," will be held at booth 311B Hall T6. According to the announcement, Hiwave will present its system-level thinking and engineering practice for next-generation computing infrastructure, covering AIDC cooling technology trends, liquid cooling technology evolution, and the differentiated implementation of prefabricated cooling delivery. The announcement frames AIDC cooling selection as a multi-variable system decision rather than a simple liquid-versus-air replacement. Hiwave identifies six interrelated factors shaping cooling technology selection and deployment: policy and standards, climate and water resources, building form, customer requirements, TCO, and construction and O&M. On liquid cooling, the company highlights three focus areas: full-server liquid cooling moving from localized component cooling toward system-level thermal management; cold plate evolution from single-phase toward two-phase cooling; and CDU upgrades toward larger capacity, higher adaptability, modularity and intelligence. On delivery, Hiwave promotes prefabrication, modularization and productization to shift engineering work from on-site integration to factory prefabrication and standardized delivery, while retaining differentiated cold source configurations including cooling towers, dry coolers and high-temperature chillers to suit local conditions. ### Key figures - Event date: November 19, 2026 - Venue: China National Convention Center, Beijing - Booth: 311B Hall T6 - Six key variables identified as shaping AIDC cooling selection: policy and standards, climate and water resources, building form, customer requirements, TCO, and construction and O&M - Three liquid cooling focus areas: full-server liquid cooling, cold plate evolution (single-phase to two-phase), CDU capability upgrades - Fast delivery requirements cited: T+3/T+4 - Three cold source types cited: cooling towers, dry coolers, high-temperature chillers - No specific financial, capacity, market share or investment figures disclosed. ### Why it matters to ebm-papst This event is a market signal that Chinese AIDC cooling discussions are shifting from component-level performance toward system-level, full-chain thermal management, with liquid cooling and prefabricated delivery positioned as the main upgrade paths. For ebm-papst, a supplier of fans and motors for cooling equipment, the framing matters because air cooling is explicitly described as complementary rather than obsolete: Hiwave states that air and liquid cooling can be flexibly combined into hybrid air-liquid configurations depending on server configuration, auxiliary component cooling needs and room conditions. This preserves demand for high-efficiency fans and motors in CDUs, chillers, dry coolers, cooling towers and hybrid systems. Assessment (inference): Hiwave's emphasis on prefabrication, modularization and standardized delivery could favor suppliers that can offer standardized, factory-integrated fan and motor subassemblies with predictable specifications, rather than purely customized on-site solutions. Assessment (inference): The explicit focus on CDU capacity growth, adaptability and intelligence suggests growing demand for fans and motors in CDU heat exchange and flow management, an addressable opportunity for ebm-papst. Assessment (inference): The six-variable framework, particularly climate and water resources plus TCO, indicates that dry coolers and high-temperature chillers will remain relevant in northern and water-constrained regions, sustaining air-movement component demand alongside liquid cooling growth. Assessment (inference): As a Chinese domestic cooling player promoting system-level solutions, Hiwave could strengthen local competitors' integration capabilities, so ebm-papst should monitor whether Hiwave's standardized platforms lock in component specifications early in design cycles.

## Full text (English translation)

Computing power continues to leap forward—how can cooling systems keep pace?

With the rapid development of artificial intelligence, large models and high-performance computing, data centers are accelerating into a new stage of high density, high power and large-scale deployment. Per-cabinet power consumption continues to break through, computing density keeps climbing, and traditional cooling architectures face new heat dissipation challenges. At the same time, energy efficiency, construction cycles, resource utilization and long-term operating costs have become important factors that must be coordinated in building next-generation computing infrastructure.

From the accelerated evolution of liquid cooling technology to the gradual maturity of prefabricated delivery models, AIDC cooling systems are undergoing a profound transformation from single-equipment optimization to system-level collaborative upgrading.

However, does liquid cooling mean that air cooling must be fully replaced in all scenarios? How should intelligent computing centers in different regions and of different scales choose cold source configurations? Facing rapid delivery demands, how can advanced cooling technologies truly achieve large-scale implementation?

Technology routes must be determined by needs, and engineering delivery must be standards-led.

On November 19, the 2026 CDCC Data Center Standards Forum will be held at the China National Convention Center in Beijing. Under the theme "Driving Change Toward Practice, Full-Chain Intelligent Cooling," Hiwave will hold a special session on Hiwave AIDC full-chain solution practice, sharing system-level thinking and engineering practice for next-generation computing infrastructure around AIDC cooling technology development trends, liquid cooling technology evolution and differentiated implementation of prefabrication, and exploring upgrade paths for efficient, reliable and green cooling systems.

I. Six variables interwoven: AIDC cooling technology enters the era of system decisions

The upgrade of AIDC cooling technology is not simply replacing air cooling with liquid cooling, nor merely pursuing higher-specification cooling equipment. Rather, it requires comprehensive decisions on technology routes, system architecture and full-lifecycle costs based on project conditions.

Hiwave believes that the key factors affecting the selection and implementation of AIDC cooling technology are mainly concentrated in six dimensions:

Policy and standards: As green and low-carbon development requirements for data centers continue to deepen, energy efficiency indicators, construction specifications and related technical standards are continuously improved, driving cooling systems toward high energy efficiency and standardization.

Climate and water resources: Differences in climate conditions, natural cold source utilization conditions and water resource endowments across regions directly affect cold source forms, system configurations and operating strategies.

Building form: The building structure, spatial layout, load-bearing conditions and mechanical and electrical space of data centers determine the deployment method of cooling equipment and the system integration path.

Customer requirements: Different customers differ in computing density, business continuity, expansion needs and construction cycles, requiring matching cooling architectures and reliability designs.

TCO cost: Cooling systems should not focus only on initial equipment investment; construction input, energy consumption, water resource use, O&M management and future upgrade and renovation costs must also be comprehensively considered.

Construction and O&M: On-site construction conditions, engineering organization capability, O&M level and later maintenance convenience also determine whether a technical solution can truly be implemented.

The six variables are interrelated and jointly affect the choice of cooling technology routes.

This means that future competition in AIDC cooling systems will no longer be competition over single-equipment performance, but comprehensive competition based on scenario understanding, system design, resource allocation and full-lifecycle cost management.

II. Liquid cooling evolution led by system thinking: building deterministic heat dissipation capability for high-density computing

As GPU computing power continues to grow, traditional air cooling is gradually facing limitations in heat dissipation capability and spatial layout in some high-power-density scenarios. With more efficient heat transfer capability, liquid cooling is becoming an important technology direction for next-generation high-density computing infrastructure.

But liquid cooling technology is not an upgrade of a single device; it involves overall coordination of servers, coolant, CDUs, distribution piping networks, cold sources and control systems.

Around the development trends of liquid cooling technology, Hiwave focuses on three directions:

01 Full-server liquid cooling: from localized heat dissipation to system-level thermal management

As chip power density continues to increase, liquid cooling technology is developing from localized cooling of key components toward liquid cooling of servers over a wider scope.

By optimizing the internal thermal management architecture of servers, the liquid cooling system can more directly handle the heat dissipation needs of high-heat-flux components, improving thermal management capability in high-density computing scenarios.

At the same time, air cooling and liquid cooling are not a simple replacement relationship; they can be flexibly combined according to server configuration, auxiliary component cooling needs and room conditions to form hybrid air-liquid solutions adapted to different computing architectures.

02 Cold plate technology evolution: from single-phase to two-phase, expanding the boundaries of liquid cooling technology

Cold plate liquid cooling is an important technology route in current data center liquid cooling applications.

As chip thermal design power continues to increase, cold plate liquid cooling technology is also continuously evolving, exploring from single-phase cooling toward two-phase cooling and other technical directions to adapt to heat dissipation needs under higher heat flux densities.

Different technical routes have their own characteristics in system complexity, medium properties, operation control and engineering adaptability, and need comprehensive evaluation combined with server architecture, application environment and full-lifecycle costs.

03 CDU capability upgrade: large capacity, high adaptability, strengthening system support

As an important link connecting the primary-side cold source and secondary-side IT equipment in liquid cooling systems, the CDU's heat exchange capability, flow control, redundancy design and operational reliability directly affect the overall performance of the liquid cooling system.

Facing high-density computing needs, CDUs are developing toward large capacity, high adaptability, modularization and intelligence.

By optimizing flow distribution, temperature control and operation management of liquid cooling systems, the cooling system's adaptability to different server configurations, different cabinet power levels and future computing architectures is improved.

From server liquid cooling to cold plate technology evolution and then to CDU system capability upgrades, liquid cooling is driving data center heat dissipation from localized optimization toward full-chain thermal management.

III. Prefabrication and differentiation in parallel: enabling advanced cooling technologies to truly land

If liquid cooling solves the heat dissipation problem of high-density computing, then prefabrication solves the problem of how advanced cooling systems can be efficiently built, scaled and rapidly delivered.

Facing increasingly urgent construction cycles for AIDC projects, fast delivery requirements such as T+3/T+4 pose greater challenges to traditional on-site construction models. Cold source equipment, distribution piping networks, CDUs and terminal systems involve multiple professional disciplines. If they still rely on decentralized procurement, on-site integration and item-by-item commissioning, it is easy to increase engineering coordination complexity and affect overall delivery efficiency.

Hiwave takes prefabrication, modularization and productization as important directions, promoting the transformation of cooling systems from on-site engineering integration to factory prefabrication and standardized delivery.

Through standardized design, modular combination, factory prefabrication and system testing, more engineering steps are moved forward to the factory, improving system integration efficiency and delivery certainty.

At the same time, prefabrication does not mean that all projects adopt completely identical cooling configurations. Different regions, different building conditions and different computing scales still have differences in the selection of cold source equipment. Hiwave emphasizes adapting to local conditions, achieving synergy between standardized delivery and differentiated application through a diversified cold source matrix and modular configuration.

Cooling towers: Adapt to corresponding cooling architectures and operating strategies based on local climate and water resource conditions.

Dry coolers: Fully consider outdoor meteorological conditions and natural cold source utilization potential to optimize system operation modes.

High-temperature chillers: Configure reasonably according to terminal water supply temperature, load demand and system energy efficiency requirements.

Through the combination and coordination of different cold source equipment, both project construction conditions, operating efficiency and long-term operating costs are taken into account.

This enables the cooling system to have standardized, modular delivery capability while retaining flexible adaptability for different application scenarios.

IV. From technology upgrade to green development: building sustainable computing infrastructure

Continued growth in computing scale means digital infrastructure needs to consume more energy and resources. How to improve energy utilization efficiency, rationally allocate water resources and reduce full-lifecycle operating costs while ensuring computing supply has become an important topic in the green development of data centers.

The upgrade of AIDC cooling technology should not focus only on short-term heat dissipation performance, but should be coordinated across the full lifecycle dimensions of construction, operation, maintenance and upgrade.

The development of liquid cooling technology provides a more suitable thermal management path for high-density computing; prefabricated and modular delivery helps reduce repetitive on-site work and improve engineering organization efficiency; diversified cold sources and differentiated configuration provide more flexible energy-saving optimization space for data centers under different regional and resource conditions.

The coordination of the three promotes cooling systems from single-point technology innovation to system-level energy efficiency optimization, and from one-time engineering construction to standardized, replicable infrastructure delivery.

Facing the high-quality development of the digital economy, Hiwave continues to deepen technological innovation around full-stack liquid cooling, air-liquid fusion, diversified cold source coordination and prefabricated integration, promoting deep integration of cooling systems and computing infrastructure.

Make technology routes more certain, engineering delivery more efficient, and energy utilization more intensive.

On November 19, at the 2026 CDCC Data Center Standards Forum, Hiwave will share systematic practice on the deterministic upgrade of AIDC cooling technology, liquid cooling technology evolution and differentiated implementation of prefabrication, and discuss with industry partners the development direction of next-generation green computing infrastructure.

In the future, Hiwave will continue to rely on system-level solutions as support and standardization and prefabrication as delivery guarantees, promoting data center cooling technology toward efficient, reliable, flexible and sustainable development, and contributing professional strength to digital economy infrastructure construction.

2026 CDCC Data Center Standards Forum
Driving Change Toward Practice · Full-Chain Intelligent Cooling
Hiwave AIDC Full-Chain Solution Practice Session
Time: November 19, 2026
Venue: China National Convention Center, Beijing
Booth: Hall 311B T6
How can cooling technology achieve a deterministic upgrade? Liquid cooling-led, or prefabrication implementation?
Hiwave invites you to gather in Beijing to explore new paths for liquid cooling technology evolution and large-scale prefabrication implementation, and jointly build a green, efficient and reliable new future for computing infrastructure.

## Full text (original)

算力持续跃迁，冷却体系如何与之同行？
随着人工智能、大模型及高性能计算快速发展，数据中心正加速迈向高密度、高功率与规模化部署的新阶段。单柜功耗持续突破，算力密度不断攀升，传统制冷架构面临新的散热挑战。与此同时，能源效率、建设周期、资源利用与长期运营成本，也成为下一代算力基础设施建设必须统筹考量的重要因素。
从液冷技术加速演进，到预制化交付模式逐步成熟，AIDC冷却系统正在经历从单一设备优化向系统级协同升级的深刻变革。
然而，液冷是否意味着所有场景都要全面替代风冷？不同地域、不同规模的智算中心，应该如何选择冷源配置？面对快速交付需求，如何让先进冷却技术真正实现规模化落地？
技术路线需要因需而定，工程交付需要标准先行。
11月19日，2026 CDCC数据中心标准论坛大会将在北京国家会议中心举行。海悟将以「驭变向实 全链智冷」为主题，举办海悟AIDC全链路解决方案实践专场，围绕AIDC冷却技术发展趋势、液冷技术演进与预制化差异落地，分享面向下一代算力基础设施的系统思考与工程实践，探索高效、可靠、绿色的冷却体系升级路径。
一、六大变量交织，AIDC冷却技术进入系统决策时代
AIDC冷却技术的升级，并不是简单地用液冷替代风冷，也不是单纯追求更高规格的制冷设备，而是需要结合项目条件，对技术路线、系统架构和全生命周期成本进行综合决策。
海悟认为，影响AIDC冷却技术选型与落地的关键因素，主要集中在六个维度：
政策标准： 随着数据中心绿色低碳发展要求持续深化，能效指标、建设规范及相关技术标准不断完善，推动冷却系统向高能效、标准化方向发展。
气候水资源： 不同地域的气候条件、自然冷源利用条件及水资源禀赋存在差异，直接影响冷源形式、系统配置与运行策略。
建筑形式： 数据中心的建筑结构、空间布局、承重条件及机电空间，决定冷却设备的部署方式与系统集成路径。
客户需求： 不同客户在算力密度、业务连续性、扩容需求及建设周期方面存在差异，需要匹配不同的冷却架构与可靠性设计。
TCO成本： 冷却系统不能只关注初始设备投资，还需综合考虑建设投入、能源消耗、水资源使用、运维管理及未来升级改造成本。
施工运维： 现场施工条件、工程组织能力、运维水平与后期维护便利性，同样决定技术方案能否真正落地。
六大变量相互关联，共同影响冷却技术路线的选择。
这意味着，未来AIDC冷却系统的竞争，不再是单一设备性能的竞争，而是基于场景认知、系统设计、资源配置与全生命周期成本管理的综合竞争。
二、液冷主导演进，构建面向高密算力的确定性散热能力
随着GPU算力持续增长，传统风冷在部分高功率密度场景下逐渐面临散热能力与空间布局的限制。液冷凭借更高效的热传递能力，正成为下一代高密度算力基础设施的重要技术方向。
但液冷技术并非单一设备的升级，而是涉及服务器、冷却液、CDU、输配管网、冷源及控制系统的整体协同。
围绕液冷技术的发展趋势，海悟重点关注三个方向：
01 服务器全液冷：从局部散热走向系统级热管理
随着芯片功率密度持续提升，液冷技术正从局部关键器件散热向更大范围的服务器液冷化发展。
通过优化服务器内部热管理架构，让液冷系统更直接地承担高热流密度器件的散热需求，提升高密度算力场景下的热管理能力。
同时，风冷与液冷并非简单的替代关系，而是可以根据服务器配置、辅助器件散热需求及机房条件进行灵活组合，形成适配不同算力架构的风液融合方案。
02 冷板技术演进：从单相到两相，拓展液冷技术边界
冷板式液冷是当前数据中心液冷应用的重要技术路线。
随着芯片热设计功耗持续提升，冷板液冷技术也在不断演进，从单相冷却向两相冷却等技术方向探索，以适应更高热流密度下的散热需求。
不同技术路线在系统复杂度、介质特性、运行控制及工程适配方面各有特点，需要结合服务器架构、应用环境和全生命周期成本进行综合评估。
03 CDU能力升级：大容量、高适配，强化系统支撑
CDU作为液冷系统中连接一次侧冷源与二次侧IT设备的重要环节，其换热能力、流量控制、冗余设计及运行可靠性，直接影响液冷系统整体表现。
面向高密度算力需求，CDU正朝着大容量、高适配、模块化及智能化方向发展。
通过优化液冷系统的流量分配、温度控制与运行管理，提升冷却系统对不同服务器配置、不同机柜功率及未来算力架构的适配能力。
从服务器液冷化到冷板技术演进，再到CDU系统能力升级，液冷正在推动数据中心散热从局部优化走向全链路热管理。
三、预制化与差异化并行，让先进冷却技术真正落地
如果说液冷解决的是高密算力的散热问题，那么预制化解决的就是先进冷却系统如何高效建设、规模复制与快速交付的问题。
面对AIDC项目日益紧迫的建设周期，T+3/T+4等快速交付需求，对传统现场施工模式提出了更高挑战。冷源设备、输配管网、CDU及末端系统涉及多个专业环节，如果仍然依赖分散采购、现场集成和逐项调试，容易增加工程协同复杂度，影响整体交付效率。
海悟以预制化、模块化、产品化为重要方向，推动冷却系统从现场工程集成向工厂预制与标准化交付转变。
通过标准化设计、模块化组合、工厂预制与系统测试，将更多工程环节前置至工厂，提升系统集成效率与交付确定性。
与此同时，预制化并不意味着所有项目采用完全相同的冷却配置。
不同地域、不同建筑条件及不同算力规模，对冷源设备的选择仍然存在差异。海悟强调因地制宜，通过多元冷源矩阵与模块化配置，实现标准化交付与差异化应用的协同。
冷却塔： 结合当地气候及水资源条件，适配相应冷却架构与运行策略。
干冷器： 充分考虑室外气象条件与自然冷源利用潜力，优化系统运行方式。
高温冷水机组： 根据末端供水温度、负荷需求及系统能效要求，进行合理配置。
通过不同冷源设备的组合与协同，兼顾项目建设条件、运行效率及长期运营成本。
让冷却系统既具备标准化、模块化的交付能力，又保留面向不同应用场景的灵活适配空间。
四、从技术升级到绿色发展，构建可持续算力基础设施
算力规模持续增长，意味着数字基础设施需要消耗更多能源与资源。如何在保障算力供给的同时，提升能源利用效率、合理配置水资源、降低全生命周期运营成本，已经成为数据中心绿色发展的重要课题。
AIDC冷却技术的升级，不应只关注短期散热性能，更应从建设、运行、维护与升级等全生命周期维度进行统筹。
液冷技术的发展，为高密度算力提供了更加适配的热管理路径；预制化与模块化交付，有助于减少现场重复作业、提升工程组织效率；多元冷源与差异化配置，则为不同地域和资源条件下的数据中心提供更灵活的节能优化空间。
三者协同，推动冷却系统从单点技术创新走向系统级能效优化，从一次性工程建设走向标准化、可复制的基础设施交付。
面向数字经济高质量发展，海悟持续围绕全栈液冷、风液融合、多元冷源协同与预制化集成深化技术创新，推动冷却系统与算力基础设施深度融合。
让技术路线更加确定，让工程交付更加高效，让能源利用更加集约。
11月19日，2026 CDCC数据中心标准论坛大会，海悟将围绕AIDC冷却技术的确定性升级，分享液冷技术演进与预制化差异落地的系统实践，与行业伙伴共同探讨下一代绿色算力基础设施的发展方向。
未来，海悟将继续以系统级解决方案为支撑，以标准化、预制化为交付保障，推动数据中心冷却技术向高效、可靠、灵活与可持续方向发展，为数字经济基础设施建设贡献专业力量。
2026 CDCC数据中心标准论坛大会
驭变向实 · 全链智冷
海悟AIDC全链路解决方案实践专场
时间：2026年11月19日
地点：北京·国家会议中心
展位：311B厅 T6
冷却技术如何确定性升级？液冷主导，还是预制落地？
海悟邀您相聚北京，共探液冷技术演进与预制化规模落地新路径，共筑绿色、高效、可靠的算力基础设施新未来。