Data Center World Power: AI racks hit 1 MW as global data center demand heads past 200 GW by 2030

Data Center KnowledgeT22026-09-29 · INTL · NVIDIA
Market dataDatacenterPolicy / standards

Intelligence brief

What happened At the Data Center World Power conference in Dallas, held Sept. 21-23, leaders from utilities, power producers, hyperscalers, data center developers, operators, and supply chain partners convened to address how to scale power capacity for AI-driven data centers while safeguarding grid reliability, protecting ratepayers, and accelerating economic development. Bill Kleyman, executive chair of the Data Center World Power Advisory Board and CEO and co-founder of Apolo.us, opened an early session by laying out the realities of deploying Nvidia DGX-class servers. He noted that a standard rack can accommodate six such systems, each built around eight Nvidia H100 accelerators, with individual accelerator cards costing up to $40,000. He cited AFCOM's State of the Data Center 2026 survey, in which 69% of respondents expect rack density to increase like nothing seen in the past, alongside 36% growth in liquid cooling adoption. Scott Hart, executive vice president of NRG Business, described how customer requirements have escalated from traditional 20- to 40-MW grid-connected facilities, to cloud campuses in the 100 MW range, and now to conversations about a gigawatt and beyond. He pointed to two clocks running during data center development: a technology clock operating on timelines of months or a few years, and a power infrastructure clock operating on decades, noting that a utility needs a minimum 15-year time horizon and commitment with a secured offtake agreement. He said most data center projects NRG works on are excited about being part of a demand response program. Alise Porto, vice president of sustainability and strategic initiatives at Switch, said site selection now revolves around power and community together, and that Switch's "AI factory" design targets up to 2 MW per rack with modularity to scale cabinet-level power draw. Dado Slezak, executive vice president of energy capital and strategy at QTS, emphasized capital intensity, saying that for every dollar of generation there are multiple dollars of data center infrastructure, and that there is no point when you can look three or four years in advance and know what you should build. ### Key figures - Global data center power demand projected to exceed 200 GW by 2030 - Typical rack densities moving from roughly 10-30 kW into 80-150 kW, with advanced deployments approaching 1 MW per rack - Individual campuses scaling into the hundreds of megawatts and beyond - A standard rack can accommodate six Nvidia DGX-class systems, each built around eight Nvidia H100 accelerators - Individual Nvidia H100 accelerator cards costing up to $40,000 - 69% of AFCOM State of the Data Center 2026 survey respondents expect rack density to increase - 36% growth in liquid cooling adoption in data centers - Traditional data centers described as grid-connected, 20- to 40-MW facilities; cloud campuses in the 100 MW range; current conversations at a gigawatt and beyond - Utilities need a minimum 15-year time horizon and commitment with a secured offtake agreement; assets planned and financed over 15-30 years - Switch's "AI factory" design targets up to 2 MW per rack - Conference held Sept. 21-23 in Dallas ### Why it matters to ebm-papst This is a direct demand signal for high-density cooling and air-movement components. The shift from 10-30 kW to 80-150 kW racks, and toward 1-2 MW racks, compresses the addressable market for fans and blowers into fewer, larger, higher-value units per rack, and it favors suppliers that can support both air cooling today and liquid cooling later, as Switch explicitly described. Assessment (inference): ebm-papst's opportunity is strongest where operators want modularity and a migration path from air to liquid cooling, since that requires fan and blower solutions that remain viable as cabinet-level power draw scales. The stated 36% growth in liquid cooling adoption is a competitive threat to conventional air-cooling content per rack, but it also creates demand for hybrid architectures, rear-door heat exchangers, and high-static-pressure fans that bridge both modes. Assessment (inference): The utility constraint described by NRG, a minimum 15-year commitment against a technology clock of months to a few years, suggests that on-site generation, demand response, and battery-backed operation will grow. That could shift some cooling load to islanded or hybrid power environments where efficiency and part-load performance matter more, a specification area where ebm-papst can differentiate. Assessment (inference): The 200 GW by 2030 projection and gigawatt-scale campus pipeline indicate that hyperscaler and colocation customers will increasingly standardize on reference designs. ebm-papst should prioritize engagement with developers such as Switch and QTS at the design stage, since the article indicates cooling and density decisions are being locked in through modular "AI factory" concepts rather than retrofitted later.

Full text

The 200 GW Moment: Reinventing the Grid for the AI Economy As AI pushes rack densities into unprecedented territory, utilities, hyperscalers, and developers are rethinking how to deliver reliable, affordable power at massive scale. Global data center power demand is projected to exceed 200 gigawatts (GW) by 2030. AI workloads are driving typical rack densities from roughly 10-30 kW into 80-150 kW, with advanced deployments approaching 1 MW per rack. Individual campuses are scaling into the hundreds of megawatts and beyond. The pace of growth is unprecedented. At the Data Center World Power conference in Dallas, held Sept. 21-23, leaders from utilities, power producers, hyperscalers, data center developers, operators, and supply chain partners discussed how to scale capacity while safeguarding grid reliability, protecting ratepayers, and accelerating economic development. Bill Kleyman, executive chair of the Data Center World Power Advisory Board and CEO and co-founder of Apolo.us, opened an early session by laying out the realities of deploying Nvidia DGX-class servers. He noted that a standard rack can accommodate six such systems, each built around eight Nvidia H100 accelerators, with individual accelerator cards costing up to $40,000. “Sixty-nine percent of respondents to AFCOM’s State of the Data Center 2026 survey expect that rack density is going to increase like nothing we've seen in the past,” Kleyman said. “In parallel, we are seeing 36% growth in liquid cooling adoption in data centers, and that's continuing to expand.” Utilities Confront the Gigawatt-Scale Campus Scott Hart, executive vice president of NRG Business, a major provider of retail electricity, natural gas, and demand response in North America, described how customer requirements have escalated. “Traditionally, data centers would be a grid-connected, 20- to 40-MW facility,” he said. “Then we saw the cloud campuses in the 100 MW range, but now conversations have pivoted to a gigawatt and beyond.” With projects of that scale, it can be challenging for a utility to commit to constructing a power plant. Hart explained that there are two clocks running during data center development: a technology clock that operates on timelines of months or a few years, and a power infrastructure clock that operates on decades. That creates friction when customers want capacity on near-term timelines, but utilities must plan and finance assets over 15-30 years. “A utility needs a minimum 15-year time horizon and commitment with a secured [offtake agreement] that can pay for that entire period,” Hart said. Some sites will remain grid-only. Increasingly, however, projects are pursuing hybrid arrangements that combine grid supply with on-site generation and storage, Hart noted. That can involve mixing technologies such as geothermal, gas turbine plants, and renewables. Hart added that incorporating demand response – programs in which customers curtail load or shift to on-site resources during grid stress in exchange for incentives – is becoming more attractive. “Most of the data center projects we work on are excited about being part of a demand response program,” he said. Site Selection: Power and Community Alise Porto, vice president of sustainability and strategic initiatives at Switch, said the site selection calculus has changed. A few years ago, proximity to major metro areas and robust fiber connectivity often dominated decisions. Today, available and reliable power is paramount. “Everything now revolves around power,” Porto said. “And more recently, the scope has expanded to both power and community – it is those two together that now coordinate where you go, how big you go, and what you do.” “Everything now revolves around power.” – Alise Porto, vice president of sustainability and strategic initiatives, Switch Utilities, initially surprised by multi-hundred-megawatt and gigawatt-scale requests, are increasingly engaging earlier and collaborating on flexible solutions, Porto noted. That can include agreeing to reduce power draw during peak conditions or temporarily switching to batteries or backup generators to support local grid reliability when needed. To maintain optionality as chip roadmaps evolve, Switch is pursuing designs that accommodate both current and future cooling methods and densities. “Depending on the type of chips our customers have, they can deploy air cooling now and utilize liquid cooling later,” Porto said. She added that Switch’s “AI factory” design targets up to 2 MW per rack, with modularity to allow cabinet-level power draw to scale as denser server architectures enter the market. Developer and Operator Economics Dado Slezak, executive vice president of energy capital and strategy at QTS, emphasized the capital intensity of AI data centers, particularly when on-site power is part of the plan. “For every dollar you've got of generation, you've got multiple dollars of data center infrastructure,” he said. “With that scale of investment, there must be a decades-long financial return secured contractually.” Slezak also cautioned against rigid long-term prescriptions. “There is no point when you can look three or four years in advance and know what you should build,” he said. “A lot can change in that time, and decisions keep shifting, each with a downstream impact.” He urged deep collaboration among partners to manage evolving technology targets and interconnection realities.