Sungrow completes world-first 500MW on-site broadband oscillation reproduction and suppression test in Qinghai

News · SungrowT22026-07-28 · CN · Sungrow (300274.SZ)
Market dataESS

Intelligence brief

What happened At the "Seminar on Conditions and Capabilities for Building a New-Type Power System," Pan Nian'an, Chief Expert and Ground PV Chief Engineer at Sungrow (300274.SZ), presented the company's latest innovation results. Earlier in 2026, State Grid Northwest Branch, together with the China Electric Power Research Institute, State Grid Qinghai Electric Power, State Power Investment Corporation's Huanghe Company, and Sungrow, conducted the world's first on-site broadband oscillation reproduction and suppression test at the 500MW Dingyao PV-plus-storage station in Hainan Prefecture, Qinghai Province. The test relied on Sungrow inverters. After several months of joint analysis and verification, a systematic set of test results was formed, which the company describes as a key step forward in broadband oscillation suppression research. The test targeted two long-standing difficulties: safely and controllably reproducing oscillations at a real station, and validating effective suppression measures. Using an impedance cart to emulate a weak-grid environment, the team traced the causes of broadband oscillation and, for the first time, identified power, system short-circuit ratio (SCR), and control parameters as key influencing factors, achieving controllable reproduction of local system oscillations. The test also validated the suppression effect of Sungrow's grid-forming control strategy, keeping the system stable across a wide SCR range (0-100) and effectively suppressing transient overvoltage. Sungrow cited prior incidents to underline the stakes: the 2025 Iberian Peninsula blackout caused by oscillation-triggered cascading disconnections, affecting more than 50 million people; repeated forced outages at China's Zhangbei VSC-HVDC project after 2020 due to super-synchronous oscillation; and the 2019 Hornsea offshore wind farm disconnection in the UK due to sub-synchronous oscillation, which caused roughly 3.2% of system load loss and affected about 1 million users. ### Key figures - Test site capacity: 500MW (Dingyao PV-plus-storage station, Hainan Prefecture, Qinghai) - SCR range validated for stable operation: 0-100 - Iberian Peninsula blackout (2025): more than 50 million people affected - UK Hornsea offshore wind disconnection (2019): about 3.2% of system load lost, roughly 1 million users affected - Zhangbei VSC-HVDC project: multiple forced station outages due to super-synchronous oscillation after 2020 - Test timeline: initiated early 2026; results finalized after several months of joint analysis - No specific figures disclosed for investment amount, production capacity, or market share. ### Why it matters to ebm-papst This result is a market signal that grid-forming inverter control and oscillation suppression are moving from simulation to engineering validation at utility scale. For ebm-papst, the direct relevance is indirect but real: as PV-plus-storage and weak-grid projects multiply, demand grows for reliable cooling of power electronics (inverters, PCS, storage containers) and for fans that tolerate wide operating ranges and transient overvoltage conditions. Chinese inverter makers such as Sungrow strengthening their grid-support credentials could accelerate deployment of large PV and storage fleets in weak-grid regions, expanding the addressable market for high-reliability, high-efficiency fan and blower solutions. Assessment (inference): ebm-papst is unlikely to face direct competition from Sungrow in fans or motors, but Sungrow's growing system-level influence may shift procurement specifications toward integrated, grid-forming power conversion cabinets, where cooling component requirements are set earlier in the design cycle. Assessment (inference): European and Middle Eastern weak-grid and offshore projects cited in the article suggest a cross-regional opportunity, since oscillation-related outages raise the value of robust thermal management in power electronics. Assessment (inference): ebm-papst should monitor whether Chinese grid-forming standards and test methodologies become export references, as that could standardize cooling requirements in overseas projects where ebm-papst has stronger customer relationships.

Full text

Original English translation
A problem that has troubled the industry for years — broadband oscillation — was, for the first time globally, controllably reproduced and successfully suppressed at a real 500MW station. Recently, at the "Seminar on Conditions and Capabilities for Building a New-Type Power System," Pan Nian'an, Ground PV Chief Engineer and Chief Expert at Sungrow, shared the company's innovative practice results. Earlier this year, State Grid Northwest Branch, together with the China Electric Power Research Institute, State Grid Qinghai Electric Power, State Power Investment Corporation Huanghe Company, and Sungrow, completed the world's first on-site broadband oscillation reproduction and suppression test at the 500MW Dingyao PV-plus-storage station in Hainan Prefecture, Qinghai, relying on Sungrow inverters. After several months of joint analysis and verification, a systematic set of test results was ultimately formed, marking a key step forward in broadband oscillation suppression technology research. Why does a single on-site test touch a nerve across the new energy industry? Consider a set of real cases: In 2025, the Iberian Peninsula grid, covering Spain and Portugal, suffered cascading disconnections triggered by oscillation, causing a system-wide blackout that affected more than 50 million people; In 2020, after China's Zhangbei VSC-HVDC project was put into operation, stations were repeatedly forced to shut down due to super-synchronous oscillation; In 2019, the UK's Hornsea offshore wind farm experienced large-scale disconnection due to sub-synchronous oscillation, causing about 3.2% of system load loss and affecting about 1 million users. Behind these accidents lies the same problem — broadband oscillation. As new energy penetration continues to rise, broadband oscillation has become a severe challenge for the global new energy industry. However, because the oscillation mechanism is complex and hard to predict, related research has long faced two major difficulties: first, it is difficult to safely and controllably reproduce oscillation at a real station; second, there is a lack of engineering-validated effective suppression methods. As a result, broadband oscillation suppression research has long remained at the theoretical simulation level, lacking systematic verification in real power station environments. Now, this technical problem that has troubled the industry for years has finally seen a key breakthrough in engineering practice. World's first engineering test achieves broadband oscillation reproduction and suppression This on-site test was carried out around the two key difficulties of "oscillation reproduction" and "oscillation suppression." For broadband oscillation reproduction, the test used an impedance cart to simulate a weak-grid environment, traced the causes of broadband oscillation, and for the first time revealed the key factors affecting broadband oscillation — power, system short-circuit ratio (SCR), and control parameters — and successfully achieved controllable reproduction of local system oscillation. In addition, the test verified the suppression effect of Sungrow's grid-forming control strategy on broadband oscillation, enabling the system to operate stably across a wide SCR range (0-100) and effectively suppressing transient overvoltage. What does this result mean for the industry? In the view of industry experts, the greatest significance of this on-site test is that it brought broadband oscillation suppression out of theoretical simulation and into a real power station for the first time, validating existing theories and technologies and providing replicable, scalable engineering practice for grid stability control in high-proportion new energy scenarios. In the future, as related technologies are further researched and key breakthroughs are made, and as they are gradually promoted through engineering application, it is expected to further improve the operating stability of new energy equipment under extremely weak grid conditions, effectively avoid disconnection problems caused by oscillation, greatly release the transmission capacity of weak-grid stations, and reduce power generation losses. "For new energy to become a truly stable and reliable main power source, the core prerequisite is having autonomous and controllable fault self-healing and grid support capabilities," said Pan Nian'an. He stated that in the future Sungrow will continue to deepen technology research and development in the grid field, advance key technology innovations such as broadband oscillation suppression, grid-forming control, and multi-energy coordination, help new energy connect to the grid stably and be consumed efficiently, and build a solid technical foundation for the energy transition and the safe and stable operation of the new-type power system. Return to Sohu to see more.