Carter Synergy 为 Granarolo 冷库定制 CO2 制冷系统

Carter Synergy installs bespoke dual CO2 refrigeration system at Granarolo's new £10m Willenhall cold store
Cooling PostT22026-09-25 · INTL
冷链商超市场数据/研究

情报详报

What happened Carter Synergy designed and installed a bespoke CO2 refrigeration system at Granarolo's new distribution centre in Willenhall, UK, according to a report published by Cooling Post on 25 September 2026. The new £10m warehouse was opened in December, replacing the company's former facility on the same site, which was destroyed by fire in January 2023. The installation comprises two independent CO2 refrigeration systems serving four temperature-controlled chilled and frozen storage areas. According to the report, this dual-system architecture provides additional operational flexibility and security. Each cold room is fitted with ceiling-mounted evaporators, which are evenly distributed across both refrigeration systems to deliver consistent cooling throughout the facility. Beyond the two housed external CO2 packs, Carter Synergy installed two gas coolers, two de-superheaters and 16 internal evaporators. The project's control systems use RDM controls, linking the refrigeration system and leak detection to the building management system. Integration is achieved through BACNet communication protocols and RDM's custom TDB software. ### Key figures - Warehouse investment: £10m - New distribution centre opened: December (year not specified in the source; the report is dated 25 September 2026) - Former facility destroyed by fire: January 2023 - Independent CO2 refrigeration systems: 2 - Temperature-controlled storage areas served: 4 (chilled and frozen) - Housed external CO2 packs: 2 - Gas coolers: 2 - De-superheaters: 2 - Internal evaporators: 16 - Control platform: RDM controls with BACNet communication and RDM custom TDB software ### Why it matters to ebm-papst This project is a further example of CO2 (R744) refrigeration being specified for a new-build UK cold storage distribution centre, a segment where natural-refrigerant architectures are increasingly standard rather than exceptional. The installation's reliance on multiple evaporators distributed across two independent systems, plus external gas coolers and de-superheaters, implies a substantial count of air-moving components — evaporator fan assemblies, gas cooler fans and related motorised air movement — across a single site. Assessment (inference): For ebm-papst, the relevant signal is less about this individual site than about the specification pattern it represents: dual-redundant CO2 systems with many distributed evaporators create repeatable demand for EC fans and motors optimised for CO2 duty, low ambient operation and integration with BMS/leak-detection architectures. Assessment (inference): The explicit BACNet and RDM control integration suggests that fan and motor components with native digital communication and monitoring capability may be advantaged in future tenders, since system integrators are already building connected control layers around refrigeration assets. Assessment (inference): Carter Synergy's role as designer and installer of bespoke systems makes it a relevant channel partner to track for UK cold store projects, though the source does not disclose which component suppliers were used, so no conclusion can be drawn about incumbent suppliers on this project. Assessment (inference): Granarolo's replacement of a fire-destroyed facility with a larger, higher-specification cold store may indicate continued investment in UK cold chain capacity, a market where ebm-papst's refrigeration and ventilation portfolio is directly applicable.

原文全文

Carter Synergy CO2 system at Granarolo cold store 25th September 2026UK: Carter Synergy designed and installed the bespoke CO2 refrigeration system at the new Granarolo distribution centre in Willenhall. The new £10m warehouse was opened in December to replace its former facility on the site which was destroyed by fire in January 2023. Two independent CO2 refrigeration systems serve the four temperature-controlled chilled and frozen storage areas, providing additional operational flexibility and security. Each cold room is fitted with ceiling-mounted evaporators, evenly distributed across both refrigeration systems to provide consistent cooling throughout the facility. In addition to the two housed external CO2 packs, Carter Synergy installed two gas coolers, two de-superheaters and 16 internal evaporators. The project’s control systems utilise RDM controls, seamlessly linking the refrigeration system and leak detection to the building management system. Integration is facilitated through BACNet communication protocols and RDM’s custom TDB software.