Data Center Infrasound Under Community Scrutiny; Cooling Towers, Fans and Generators Named Key Sources

Data Center KnowledgeT22026-09-24 · INTL
Datacenter

Intelligence brief

What happened Data Center Knowledge published an explainer on 24 September 2026 examining low-frequency noise and infrasound from data centers, as community opposition to new projects increasingly focuses on acoustic impacts that residents cannot consciously hear. The article defines infrasound as acoustic energy typically below 20 Hz, beneath the normal range of human hearing, which people may nonetheless perceive indirectly as body pressure, vibration in nearby structures, or resonance that makes doors, windows and fittings buzz. It identifies the main data center sources: cooling towers and large axial fans, which can emit low-frequency sound waves that propagate beyond the site, particularly under certain wind or atmospheric conditions; standby generators, via engines, exhaust systems and enclosures, especially during testing or outages; and server fans, which are primarily mid- to high-frequency sources but can contribute to low-frequency hum in aggregate through airflow paths and structural resonance. The article states server fans are typically secondary sources compared with cooling plants and generators. The piece notes that most infrasound-related health complaints from residents — headaches, nausea, anxiety and other problems — have not been fully validated, and that accurate measurement requires specialized equipment that few communities have deployed. It recommends mitigation measures including regular cleaning of fans and heat exchange surfaces, larger fans running at lower speeds, anti-vibration pads and isolation mounts, optimized enclosures, mufflers and silencers, minimized generator runtime, selective use of active noise control, and alternative cooling approaches such as liquid cooling with isolated pumps. It also urges operators to communicate measurement data transparently rather than dismissing residents' concerns. ### Key figures - Infrasound is defined as acoustic energy typically below 20 Hz. - No specific figures disclosed on sound pressure levels, project counts, investment amounts, market size or regulatory timelines. ### Why it matters to ebm-papst This is a demand-side signal for low-noise air movement and thermal management, the core of ebm-papst's data center portfolio. The article explicitly names cooling towers and large axial fans as leading infrasound contributors, and recommends larger-diameter fans running at lower speeds for equivalent airflow — precisely the design direction of modern EC centrifugal and axial fan platforms. It also flags liquid cooling as a way to cut reliance on high airflow, while warning that pumps and related components must be isolated to avoid new low-frequency paths. Assessment (inference): ebm-papst should treat this as a competitive and commercial opportunity rather than a direct threat. Operators facing community opposition will increasingly specify acoustic performance, not just airflow and efficiency, in cooling procurement — favouring suppliers who can document low-frequency emission data, offer low-RPM large-diameter fan options, and provide vibration-isolation and mounting guidance. Assessment (inference): the article's emphasis on measurement and transparency suggests a growing role for suppliers who can support acoustic testing and site-level noise documentation alongside hardware, which could become a differentiator in tender processes. Assessment (inference): the explicit caution that liquid cooling shifts noise to pumps and related components is a potential opening for ebm-papst's pump and fluid-movement-adjacent product lines, provided low-vibration mounting is addressed. Assessment (inference): the risk is that if fan and cooling-tower noise becomes a regulatory trigger in key markets, permitting delays could slow data center construction and soften near-term order intake; proactive acoustic positioning would mitigate that exposure.

Full text

Low-Frequency Noise and Data Centers: What to Know Infrasound produced by data centers is increasingly scrutinized by communities, making proactive mitigation and transparent communication essential for operators. Most of the noise that frustrates neighbors around data centers is audible. But one important factor isn’t: infrasound – low-frequency acoustic energy that most people can’t actually hear, yet may perceive as pressure changes, vibrations, or even building rattle. As communities scrutinize new projects, understanding what infrasound is, where it comes from, and how to control it is increasingly important. What Is Infrasound? Infrasound refers to acoustic energy typically below 20 Hz, which sits beneath the usual range of human hearing. Although it’s often inaudible, people can sometimes sense infrasound indirectly – as subtle body pressure, vibration in nearby structures, or resonance that causes doors, windows, or fittings to buzz. Where Infrasound Comes From in Data Centers Infrasound arises from both natural and human-made sources. Ocean waves, storms, and seismic activity all produce low-frequency energy. In data centers, several systems can contribute: - Cooling towers and large axial fans can emit low-frequency sound waves that propagate beyond the site, especially under certain wind or atmospheric conditions. - Standby generators – through engines, exhaust systems, and enclosures – are common sources of low-frequency noise and infrasound during testing or outages. - Server fans primarily contribute mid- to high-frequency noise; however, in aggregate, they can also contribute to low-frequency hum through airflow paths and structural resonance. They are typically secondary sources compared to cooling plants and generators. Why Low-Frequency Noise Matters Most people can’t hear infrasound, and many ordinances address only audible sound. For these reasons, one might think that the data center industry has little reason to be concerned about high levels of infrasound. In reality, infrasound is increasingly part of debates about the impact of data centers on local communities, with residents complaining that low-frequency noise and infrasound produce headaches, nausea, anxiety, and other health problems. So far, most of these claims have not been fully validated. Measuring infrasound accurately requires specialized equipment, and few communities have conducted the assessments necessary to prove infrasound at high levels – let alone to prove that data centers are the source of the sound or that it’s causing health problems. Practical Ways to Reduce Infrasound Data center operators aiming to stay in the good graces of local communities (not to mention politicians and regulators) would do well to invest in strategies for mitigating infrasound emissions from their facilities, whether real or perceived. Many options are practical and not especially costly: - Regularly clean fans and other mechanical components. Keeping blades and heat exchange surfaces clean helps equipment run smoothly and can reduce low-frequency noise and infrasound generation. - Install larger fans operating at lower speeds where feasible. Larger-diameter fans running at lower speeds can produce less low-frequency energy than smaller fans at higher RPM for equivalent airflow. - Use anti-vibration pads and proper isolation mounts to decouple infrasound-producing equipment from floors, walls, and other structural components. Low-frequency energy travels efficiently through solids, so preventing direct contact can significantly reduce transmission. - Optimize enclosures, mufflers, and silencers. Properly sealed and tuned enclosures around generators and large fans reduce low-frequency output during operations and testing. - Minimize generator runtime. Rely on the grid for normal operations, schedule tests during daytime windows, and consider battery energy storage to reduce generator use. - Consider active noise control in constrained paths. It can help in specific, controlled scenarios, but is rarely practical at a facility scale or in open-air environments, especially at very low frequencies. Prioritize source control and isolation first. - Evaluate alternative cooling approaches. Liquid cooling can reduce reliance on high airflow and the associated fan noise, but pumps and related components should be mounted and isolated to avoid introducing new low-frequency paths. Engaging the Community with Data and Transparency Beyond engineering controls, measurement and communication matter. Operators will likely win more hearts and minds if they have an open conversation about low-frequency noise and infrasound – including what’s been measured and what’s being done – rather than suggesting that the issue lies solely in neighbors’ heads.