# China liquid cooling market: cold plate holds 65% share as immersion and spray await scale-up

- Source: Hiwave News (T1)
- Published: 2026-09-22
- Score: 27.0
- Tags: Datacenter, Market data
- Original: https://www.haiwu.com/news/dynamic/2148.html

## Intelligence brief

### What happened Haiwu Technology published an industry overview on 22 September 2026 examining how China's data center cooling market is splitting across three liquid cooling architectures — cold plate, immersion and spray — as AI training and inference demand pushes rack power densities beyond what traditional air cooling can handle. The article frames liquid cooling as a necessity rather than an option for high-density intelligent computing centers, driven by China's "dual carbon" goals and green computing policies. The piece describes each architecture's working principle: spray cooling atomizes coolant directly onto heat-generating components; cold plate cooling transfers heat indirectly through copper or aluminum cold plates bonded to chips; immersion cooling submerges IT hardware entirely in dielectric coolant, split into single-phase and phase-change (two-phase) variants. It walks through system topology for each — cooling towers, CDU (coolant distribution units), primary and secondary loops, liquid-cooled racks, spray modules and immersion tanks — and weighs commercialization maturity, PUE performance, power density ceilings, retrofit difficulty and operating cost. The conclusion: cold plate remains the near-term mainstream; immersion becomes the core solution for ultra-high-density clusters as coolant costs fall and engineering matures, with phase-change immersion positioned as the industry's ultimate direction; spray cooling stays a niche, custom-project technology for now. ### Key figures - All three liquid cooling routes can hold data center PUE below 1.25, meeting green data center construction standards. - Cold plate accounts for 65% of China's liquid cooling market, per data cited from the Zhongshang Industry Research Institute. - Immersion accounts for 34% of that market; spray cooling 1%. - Cold plate cooling can push PUE below 1.25, versus roughly 1.5 typical for air cooling. - Cold plate cooling is described as reaching its limits in racks above 200 kW. - Single-phase immersion can achieve PUE below 1.2; phase-change immersion below 1.1. - Traditional air cooling supports only 10–15 kW per rack; immersion cooling readily exceeds 100 kW per rack and can reach above 200 kW. - Cold plate technology has undergone more than a decade of iteration in China. ### Why it matters to ebm-papst This is a structural demand signal for air-moving equipment in data centers, and it cuts both ways. The article's core claim — that air cooling cannot keep pace with chip power growth — is the same pressure that has driven ebm-papst's data center fan and cooling business, and it is the reason the company has invested in high-static-pressure, high-efficiency fan platforms and in liquid-cooling-adjacent components. Assessment (inference): The 65/34/1 split matters less than the direction of travel. Cold plate is retrofit-friendly and preserves most existing server and rack architecture, which means fan content per rack does not disappear — it shifts from front-panel server fans toward rack-level, CDU and sidecar heat-exchanger air movement. That is a nearer-term opportunity than immersion. Assessment (inference): Immersion's trajectory is the real competitive threat. If single-phase and phase-change immersion scale as the article predicts, server fans are eliminated entirely and rack-level air movement shrinks sharply. The 100–200 kW per-rack figures imply that a single immersion deployment can displace the air-moving content of roughly ten conventional racks. ebm-papst should treat immersion timelines — not cold plate growth — as the key variable to monitor. Assessment (inference): Spray cooling at 1% share with unresolved nozzle clogging, drift and uniformity problems is not a near-term market. It is worth tracking only as a technology watch item. Assessment (inference): The most actionable near-term play is the cold plate ecosystem: CDU pumps and heat exchangers, coolant distribution, and the air side of liquid-to-air and liquid-to-liquid heat rejection all still require fans and blowers. ebm-papst's opportunity is to be designed into CDU and heat-rejection subsystems before immersion erodes the rack-level fan market. Assessment (inference): The article cites no vendor names, procurement volumes or investment figures, so no customer-specific conclusions can be drawn from it. It is a market-structure signal, not a lead.

## Full text (English translation)

AI computing power is surging — how to choose among the three major liquid cooling routes? Cold plate liquid cooling holds the present, immersion and spray liquid cooling are poised for takeoff.

Demand for AI large-model training and inference continues to explode, high-density computing clusters are being deployed rapidly, and traditional air cooling can no longer keep up with the soaring power consumption of chips. Driven by the "dual carbon" goals and green computing policies, liquid cooling technology has become the core solution for intelligent computing center construction.

At present, the industry's mainstream liquid cooling solutions include three types: cold plate, immersion and spray. All three routes can control data center PUE below 1.25, meeting green data center construction standards. The most core difference among the three lies in the way the coolant contacts the heat-generating components of the servers. Spray cooling sprays directly onto the chip for heat exchange; cold plate cooling relies on a metal cold plate for indirect heat conduction; immersion cooling directly soaks the equipment in coolant, and can be further divided into two major branches: single-phase immersion and phase-change immersion.

Cold plate liquid cooling: retrofit-friendly, the market's first choice at present

Cold plate liquid cooling is the most mature solution for commercial deployment in China. The complete system consists of cooling towers, CDU coolant distribution units, primary and secondary side circulation piping, cooling medium and liquid-cooled racks. Inside the rack are core components such as liquid cooling plates, built-in piping, fluid connectors and manifolds.

Its working logic is simple and clear: heat generated by server chips is conducted to copper or aluminum liquid cooling plates that sit tightly against the components; driven by the CDU circulation pump, working fluids such as water, glycol solution or fluorinated liquid flow inside the cold plate and carry away the heat. The heated working fluid enters the CDU heat exchanger, transfers the heat to the outdoor cooling tower, and after the medium cools down it flows back again, forming an uninterrupted cycle.

After more than a decade of technological iteration, cold plate liquid cooling has a solid industrialization foundation. According to data from the Zhongshang Industry Research Institute, cold plate accounts for as much as 65% of China's liquid cooling market, far exceeding immersion's 34% and spray's 1% market share.

Compared with traditional air cooling, cold plate has prominent advantages. PUE can be reduced to below 1.25, better than the roughly 1.5 level common for air cooling. The biggest highlight is strong hardware compatibility: there is no need to substantially modify existing server motherboard structures, retrofit difficulty for existing computer rooms is low, and large-scale replication and deployment are easy. At the same time, the coolant does not directly contact the circuit boards, so the risk of equipment damage from leakage is lower and operational stability is stronger.

Its shortcomings are equally objective: heat must pass through the cold plate medium, the heat exchange chain is longer, and compared with immersion solutions the heat dissipation capability has a ceiling — it becomes somewhat strained in ultra-high-density rack scenarios above 200 kW.

Immersion liquid cooling: maximum heat exchange efficiency, the rising star for high-computing-power scenarios

Immersion liquid cooling means placing IT hardware entirely into insulating coolant, with heat sources and liquid exchanging heat in direct contact. The complete system is divided into outdoor cooling units, primary pipe networks, indoor CDUs, immersion chambers, IT equipment and secondary circulation piping, and comes in two modes: single-phase immersion and phase-change immersion.

Single-phase immersion: low-temperature coolant flows in from the bottom of the chamber, wraps around server components and carries away heat; the heated medium returns from the top of the chamber to the CDU, and then discharges the heat externally through a heat exchanger. The coolant remains liquid throughout, using high-boiling-point, insulating, low-corrosion hydrocarbon or fluorocarbon media.

The phase-change immersion heat exchange process is broadly the same, but the coolant has a lower boiling point. After the medium absorbs heat from the chip it boils and vaporizes; the vapor rises to the top of the chamber, condenses back into liquid upon meeting the condenser, and falls back to the bottom of the chamber by gravity to continue circulating. Relying on latent heat of phase change, its heat exchange capability is stronger.

The core advantage of immersion liquid cooling is extreme heat dissipation. Single-phase immersion can achieve PUE below 1.2, and phase-change immersion can even push it below 1.1. Its advantage in power density is enormous: traditional air cooling can carry only 10–15 kW per rack, while immersion liquid cooling easily exceeds 100 kW per rack and can reach above 200 kW, perfectly matching high-power computing clusters such as AI intelligent computing.

At the same time, immersion computer rooms can eliminate server cooling fans, achieving low-noise operation; they dispense with supporting facilities such as hot and cold aisle containment and raised floors, making the computer room layout more compact and suitable for projects with limited space.

But large-scale adoption still faces many difficulties. Immersion chambers use horizontal tank bodies, completely different from traditional vertical rack architecture, and the initial investment cost for new construction or retrofit is relatively high. Dedicated coolants such as fluorinated liquids are expensive, some media carry safety risks, and later-stage operations and maintenance processes are also more complex.

The industry generally predicts that in the short term cold plate will remain the market mainstay; in the long term, as coolant costs fall and engineering solutions are continuously optimized, immersion liquid cooling will become the core solution for ultra-high-density computing scenarios, and phase-change immersion is regarded as the ultimate direction of liquid cooling technology.

Spray liquid cooling: chip-level precise cooling, industrialization still on the way

Spray liquid cooling belongs to direct-contact cooling — figuratively speaking, it "sprays targeted cooling" onto chips. Relying on pump pressure or gravity, it precisely sprays coolant onto the surface of heat-generating components on the circuit board, directly carrying away heat. The system includes cooling towers, CDUs, circulation piping and spray racks; inside the rack are liquid distribution piping, spray modules and a return liquid collection system.

Cooling process: after the coolant is cooled in the CDU it is delivered into the rack, and sprayed through spray modules aimed at heat sources such as chips; the liquid that has absorbed heat collects in the return liquid tank at the bottom and is pumped back to the CDU for re-cooling and circulation.

In terms of heat dissipation performance, spray cooling is similar to immersion, likewise supporting high-power racks, with low noise during computer room operation. But this technology is insufficiently mature, with many pain points in engineering implementation. The spraying process easily produces liquid drift and volatilization, polluting the computer room environment; nozzle clogging and difficulty in controlling spray uniformity restrict its promotion. At present there are few deployment cases, mostly used only in a small number of customized scenarios.

Conclusion

Facing the rapid expansion of AI computing power, liquid cooling has gone from a bonus item to a hard requirement for high-density data centers. The three major liquid cooling routes each have their strengths, and there is no absolute "best solution." Cold plate wins on stability and ease of deployment; immersion is strong in heat dissipation ceiling, aimed at future high-density computing power; spray focuses on precise chip cooling and is a niche solution in the short term.

When planning intelligent computing centers, enterprises should comprehensively evaluate rack power, project budget and computer room infrastructure conditions, choose the appropriate liquid cooling technology, and find the optimal balance among computing performance, energy consumption level and construction cost.

## Full text (original)

AI 大模型训练、推理需求持续爆发，高密度算力集群快速落地，传统风冷散热已经逐渐跟不上芯片功耗暴涨的节奏。在 “双碳” 目标与绿色算力政策驱动下，液冷技术成为智算中心建设的核心解决方案。
目前行业主流液冷方案包含冷板式、浸没式、喷淋式三类，三条路线均能够把数据中心 PUE 控制在 1.25 以内，满足绿色数据中心建设标准。三者最核心的差异，在于冷却液与服务器发热元器件的接触方式。喷淋式为芯片直接喷淋换热；冷板式依靠金属冷板间接导热；浸没式则将设备直接浸泡在冷却液中，又可细分为单相浸没与相变浸没两大分支。
冷板式液冷：改造友好，现阶段市场首选
冷板式液冷是国内商业化落地最成熟的方案，整套系统由冷却塔、CDU 冷量分配单元、一次二次侧循环管路、冷却介质以及液冷机柜构成。机柜内部配置液冷板、内置管路、流体连接器、分液器等核心部件。
它的工作逻辑简单清晰：服务器芯片产生的热量传导至紧贴元器件的铜、铝材质液冷板；在 CDU 循环泵驱动下，水、乙二醇溶液或者氟化液等工质在冷板内部流动，带走热量。升温后的工质进入 CDU 换热器，将热量传递至室外冷却塔，介质降温后再次回流，形成不间断循环。
经过十余年技术迭代，冷板式液冷产业化基础扎实。据中商产业研究院数据，国内液冷市场中冷板式占比高达 65%，远超浸没式 34%、喷淋式 1% 的市场份额。
对比传统风冷，冷板式优势突出。PUE 可降至 1.25 以下，优于风冷普遍 1.5 左右的水平。最大亮点在于硬件兼容性强，无需大幅改动现有服务器主板结构，存量机房改造难度低，便于大规模复制部署。同时冷却液不会直接接触电路板，泄漏带来的设备损坏风险更低，运行稳定性更强。
短板同样客观存在：热量需要穿过冷板介质传递，换热链路更长，对比浸没方案，散热能力存在上限，面对超 200kW 超高密机柜场景会略显吃力。
浸没式液冷：换热效率拉满，高算力场景未来之星
浸没式液冷，就是把 IT 硬件整体放入绝缘冷却液中，热源和液体直接接触换热。整套系统分为室外冷却单元、一次管网，室内 CDU、浸没腔体、IT 设备与二次循环管路，分为单相浸没、相变浸没两种模式。
单相浸没：低温冷却液从腔体底部流入，包裹服务器元器件带走热量，升温介质从腔体顶部回流 CDU，再通过换热器把热量外排。冷却液全程保持液态，选用高沸点、绝缘、低腐蚀的碳氢、氟碳类介质。
相变浸没换热流程大体一致，但冷却液沸点更低。介质吸收芯片热量后沸腾汽化，蒸汽上升到腔体顶部遇冷凝器冷凝变回液体，依靠重力回落腔体底部持续循环。依靠相变潜热，换热能力更强。
浸没式液冷的核心优势就是极致散热。单相浸没可以将 PUE 做到 1.2 以下，相变浸没方案甚至能够压低至 1.1 以下。功率密度维度优势巨大：传统风冷单机柜只能承载 10~15kW，浸没式液冷单机柜轻松突破 100kW，最高可达 200kW 以上，完美适配 AI 智算等高功耗算力集群。
同时浸没机房可以取消服务器散热风扇，实现低噪音运行；省去冷热通道封闭、架空地板等配套设施，机房布局更紧凑，适合空间受限的项目。
但想要大规模普及，仍面临不少难题。浸没腔体采用卧式罐体，和传统立式机柜架构完全不同，新建或改造的初期投资成本偏高。氟化液等专用冷却液价格昂贵，部分介质存在安全风险，后期运维流程也更加复杂。
行业普遍预判，短期冷板式依旧是市场主力；长期随着冷却液成本下降、工程方案不断优化，浸没式液冷将成为超高密度算力场景的核心方案，相变浸没更是被视作液冷技术的终极方向。
喷淋式液冷：芯片级精准冷却，产业化仍在路上
喷淋式液冷属于直接接触式冷却，形象来说就是给芯片 “定点喷淋降温”。依靠泵压或者重力，把冷却液精准喷洒在电路板发热元件表面，直接带走热量。系统包含冷却塔、CDU、循环管路与喷淋机柜，机柜内配有布液管路、喷淋模块、回液收集系统。
冷却流程：冷却液在 CDU 降温后输送进机柜，通过喷淋模块对准芯片等热源喷洒；吸热后的液体汇集至底部回液箱，泵回 CDU 重新冷却循环。
散热性能层面，喷淋式和浸没式相近，同样支持高功率机柜，机房运行噪音低。但是这项技术成熟度不足，工程落地痛点较多。喷淋过程容易产生液体飘溢、挥发，污染机房环境，喷嘴堵塞、喷淋均匀度难以控制，制约了推广。目前落地案例稀少，大多只用于少量定制化场景。
结语
面对 AI 算力高速扩张，液冷已经从加分项，变成高密度数据中心的刚需。三大液冷路线各有所长，不存在绝对的 “最好方案”。冷板式胜在稳定、易落地；浸没式强在散热上限，面向未来高密算力；喷淋式主打芯片精准冷却，短期属于小众方案。
企业在规划智算中心时，要结合机柜功率、项目预算、机房基础条件综合评估，选择适配的液冷技术，在算力性能、能耗水平与建设成本之间找到最优平衡点。