Daikin Applied Europe and CTS Group patent AI data centre cooling concept targeting PUE as low as 1.09
聚合·DaikinT22026-09-21 · INTL · Daikin 大金
新品技术发布数据中心/IT散热商用暖通
▾ 3 条同事件报道

情报详报

What happened Daikin Applied Europe and CTS Group announced a jointly developed, patented cooling concept aimed at maximising energy efficiency, reducing operational costs and supporting the next generation of AI-driven data centres. The announcement was dated 21 September 2026. The concept targets low Power Usage Effectiveness (PUE) values through extensive use of free cooling, optimised water management and a system architecture designed specifically for modern high-density computing environments. It combines enhanced facility water systems, advanced controls, maximised free cooling and dedicated buffer pipe technology. The stated purpose of the buffer pipe technology and advanced controls is to maintain highly stable water temperatures supplied to liquid-cooled servers, even during sudden load changes or electrical short-break events. The companies link this requirement to artificial intelligence workloads, particularly Large Language Model (LLM) training, which they describe as creating highly dynamic thermal loads with rapid fluctuations in server heat output. According to the announcement, full-scale factory testing has validated the concept's ability to handle the demanding conditions associated with modern AI applications. The two companies position the concept as a response to data centre operators seeking partners that can provide more than individual products. ### Key figures - Projected PUE values as low as 1.09 in Nordic climates. - Projected PUE values below 1.20 even in demanding Middle Eastern environments. - The announcement states projected PUE levels below 1.2 even in some of the world's most challenging climates. - No specific figures disclosed for investment volume, production capacity, unit shipments, pricing, customer names, order intake or commercial launch dates. - No specific figures disclosed for the number of test units, test duration or test facility location. ### Why it matters to ebm-papst This is a competitive and market-signal item rather than a direct customer win or loss. Daikin Applied Europe is a major HVAC and cooling player, and a patented, validated cooling concept aimed squarely at AI data centres strengthens its position in a segment where ebm-papst supplies air-moving and thermal-management components. Assessment (inference): The emphasis on liquid cooling for high-density AI racks, combined with free cooling and tight water-temperature stability, suggests that the addressable fan and blower content per installation may shift over time from traditional air-cooled CRAC/CRAH architectures toward liquid-cooling support equipment such as dry coolers, adiabatic coolers, CDUs and re-cooling systems. ebm-papst should verify whether its current data centre portfolio is positioned for those adjacent air-moving duties, not only for room-level air handling. Assessment (inference): The Nordic PUE claim of 1.09 implies very high reliance on ambient free cooling, which typically requires large air-side or water-side heat rejection surfaces and therefore significant fan content. This could represent a volume opportunity for high-efficiency EC fans in dry cooler and cooling tower applications, provided ebm-papst is specified into Daikin Applied Europe or CTS Group platforms. Assessment (inference): The Middle East claim of below 1.20 is more demanding and may indicate a differentiated architecture; if Daikin and CTS Group succeed commercially there, competitors will likely respond with similar patented concepts, raising the importance of early design-in engagement with the major chiller and data centre cooling OEMs. Assessment (inference): The mention of electrical short-break events and rapid load swings points to controls and buffer design as the core patent claims, not air movement itself. ebm-papst's opportunity is therefore likely as a component supplier whose fan performance and controllability must integrate with the OEM's control logic; demonstrating fast-response, stable airflow at part-load conditions could be a differentiating argument. Assessment (inference): The announcement contains no disclosed customer deployments, order volumes or timelines, so the near-term commercial impact is uncertain. ebm-papst should treat this as a signal to monitor Daikin Applied Europe and CTS Group data centre projects and to confirm whether existing specifications already include ebm-papst components.

原文全文

Daikin Applied Europe and CTS Group have developed a patented cooling concept designed to maximise energy efficiency, reduce operational costs, and support the next generation of AI-driven data centres. Power Usage Effectiveness (PUE) remains one of the most important metrics for measuring data centre efficiency. The lower the PUE, the greater the proportion of energy directed to IT equipment rather than supporting infrastructure such as cooling systems. The jointly developed Daikin and CTS Group solution is designed to achieve projected PUE values as low as 1.09 in Nordic climates and below 1.20 even in demanding Middle Eastern environments. This performance is made possible through the extensive use of free cooling, optimised water management, and an innovative system architecture designed specifically for modern high-density computing environments. The result is a cooling infrastructure that consumes less energy while enabling a greater share of available electrical capacity to be dedicated to revenue-generating IT equipment. Artificial intelligence, particularly Large Language Model (LLM) training, creates highly dynamic thermal loads. Servers can experience rapid fluctuations in heat output, requiring cooling systems capable of responding instantly while maintaining stable operating conditions. To overcome this challenge, Daikin and CTS Group have developed a patented concept that combines enhanced facility water systems, advanced controls, maximised free cooling, and dedicated buffer pipe technology. This approach helps maintain highly stable water temperatures supplied to liquid-cooled servers, even during sudden load changes or electrical short-break events. Full-scale factory testing has validated the concept's ability to handle the demanding conditions associated with modern AI applications. Cooling efficiency is about much more than sustainability. It also has a direct impact on the economics of a data centre. By reducing the energy required for cooling, operators can significantly lower electricity costs throughout the lifecycle of their facilities. In addition, more efficient cooling systems reduce the overall electrical infrastructure required to support a given IT load, helping to optimise capital expenditure. Perhaps even more importantly, greater cooling efficiency allows more of a site's available power to be allocated to computing resources rather than support systems. This means more IT capacity from the same grid connection, maximising both infrastructure utilisation and return on investment. As data centres continue to grow in complexity, operators are looking for partners that can provide more than individual products. Through their patented cooling concept, Daikin Applied Europe and CTS Group have demonstrated how innovative cooling strategies can help meet these objectives, delivering projected PUE levels below 1.2 even in some of the world's most challenging climates and setting a new benchmark for efficient AI-ready data centres.