三菱电机板式换热器换热性能提升三倍

Mitsubishi Electric claims plate heat exchanger with triple heat transfer performance, cutting refrigerant charge to one-third
Cooling PostT22026-09-14 · INTL
新品技术发布热泵供暖

情报详报

What happened On 14 September 2026, Mitsubishi Electric (Japan) announced it has developed a plate heat exchanger for heat pumps whose heat transfer performance is claimed to be triple that of its conventional grooved-plate heat exchangers. The company says the design reduces the number of plate layers, which in turn allows the refrigerant charge to be reduced to approximately one-third of conventional levels. Mitsubishi Electric frames the development against the shift to flammable, lower-GWP refrigerants, where minimising refrigerant volume is essential to reduce the danger of accidental leaks. The company notes that although raising heat transfer performance reduces refrigerant charge, conventional grooved-plate heat exchangers perform insufficiently for this purpose. Inserting micro-offset fins between flat plates to promote turbulence and heat transfer was considered, but tests confirmed that the refrigerant's gas-liquid two-phase flow does not distribute uniformly across an entire plate. The new design instead uses distribution channels at the fluid inlets and outlets to ensure uniform refrigerant flow across plates, including plates fitted with micro-offset fins, reportedly producing an even distribution of gas-liquid two-phase flow refrigerant. Channel placement was optimised using proprietary analysis technology that simulates the complex flow of two-phase refrigerants. Mitsubishi states the technology could be applied to a wide range of products, including water-based cooling and heating equipment, heat pump systems for electric vehicles, and air-cooled air conditioners. ### Key figures - Heat transfer performance: claimed triple (3x) that of Mitsubishi Electric's conventional grooved-plate heat exchangers. - Refrigerant charge: approximately one-third of conventional levels. - Plate layers: reduced (no specific number disclosed). - Announcement date: 14 September 2026. - Location/company: Mitsubishi Electric, Japan. - No specific figures disclosed for production capacity, investment amount, commercial launch timing, or target sales volumes. ### Why it matters to ebm-papst This is a component-level innovation in heat pump and air-conditioning heat exchangers, not a fan or motor product, so it does not directly compete with ebm-papst's core offerings. However, it is a market signal worth tracking: higher-performance, lower-charge heat exchangers enable more compact refrigerant circuits and potentially smaller, differently configured air-side modules, which can shift the airflow, pressure and acoustic requirements placed on fans and blowers in heat pumps, air-cooled air conditioners and EV thermal systems. Assessment (inference): If Mitsubishi Electric's claimed 3x heat transfer performance and one-third refrigerant charge translate into commercial products, OEMs may redesign heat pump and air-conditioning platforms around smaller heat exchanger cores, changing fan sizing, static pressure targets and noise specifications. That could create both a risk of reduced fan content per unit and an opportunity for higher-value, more tightly integrated fan-motor assemblies optimised for new core geometries. Assessment (inference): ebm-papst should monitor whether Mitsubishi Electric licenses or supplies this heat exchanger to third parties, since broader adoption across water-based cooling/heating, EV heat pumps and air-cooled air conditioners would affect air-side component demand across several of ebm-papst's customer segments. Assessment (inference): the explicit link to flammable lower-GWP refrigerants also reinforces the regulatory-driven push toward A2L systems, a trend that favours suppliers able to co-develop sealed, safety-compliant air-moving subsystems with heat pump OEMs.

原文全文

Mitsubishi triples heat exchanger performance 14th September 2026JAPAN: Mitsubishi Electric claims to have developed a plate heat exchanger for heat pumps with a heat transfer performance triple that of its conventional grooved-plate heat exchangers. The new heat exchanger is said to reduce the number of plate layers allowing the refrigerant charge to be reduced to approximately one-third that of conventional levels. The move to flammable lower GWP refrigerants make it essential to minimise their volume to reduce the danger of accidental leaks. Mitsubishi Electric argues that although increasing heat transfer performance reduces the refrigerant charge, conventional heat exchangers with grooved plates perform insufficiently. Inserting micro-offset fins – which promote turbulence and heat transfer – between the flat plates was considered, but tests confirmed that the refrigerant’s gas-liquid two-phase flow does not distribute uniformly across an entire plate. Instead, Mitsubishi Electric’s new plate heat exchanger has distribution channels at the fluid inlets and outlets that ensure uniform refrigerant flow across plates, even those fitted with micro-offset fins. The result is said to be an even distribution of gas-liquid two-phase flow refrigerant. Channel placement was optimised using proprietary analysis technology that simulates the complex flow of two-phase refrigerants. According to be Mitsubishi, the technology could be applied to a wide range of products, including water-based cooling and heating equipment, heat pump systems for electric vehicles and air-cooled air conditioners.