### What happened Vertiv completed a modernisation of the cooling infrastructure at the Madrid headquarters of Acciona, a sustainable infrastructure solutions company, with the work announced on 20 May 2026. The contract covered an upgrade of cooling units that had already been operating reliably for more than a decade, following a proactive assessment by Vertiv's service team that identified opportunities to improve performance. Rather than replacing the installed assets, Vertiv took a lifecycle and growth-oriented design approach. The core of the solution was a switch from fixed-speed AC fans to high-efficiency, variable-speed EC fans, integrated with Vertiv Liebert iCOM controls for real-time optimisation of unit components and setpoints. Unlike conventional constant-speed cooling units, the upgraded system adjusts airflow dynamically according to actual demand. Before full rollout, Vertiv and Acciona validated the concept through a pilot upgrade on two cooling units, confirming the projected energy savings and system improvements. The full modernisation was then carried out during regular working operations, using the site's existing N+1 redundancy to maintain continuous operations with no downtime. ### Key figures - 70% reduction in energy consumption attributed to the cooling refurbishment - Projected return on investment in approximately three years - Existing cooling units had been in reliable operation for over a decade - Pilot validation conducted on two cooling units before full implementation - No specific figures disclosed for contract value, installed cooling capacity (kW), number of units modernised in the full rollout, or the freed-up power/cooling headroom in absolute terms ### Why it matters to ebm-papst The retrofit centres on exactly the component category ebm-papst competes in: high-efficiency variable-speed EC fans replacing fixed-speed AC fans in data centre cooling units. Vertiv is both a major OEM buyer of EC fans and a channel that specifies fan technology into installed-base modernisations, so a publicly referenced, repeatable retrofit playbook built around EC fan upgrades reinforces demand for the technology class ebm-papst supplies. Assessment (inference): The strategic risk is that Vertiv frames this as a Vertiv-led service and controls story (Liebert iCOM plus EC fan upgrade), which strengthens its position as the party that owns the retrofit decision and the fan specification. If Vertiv standardises on a preferred EC fan supplier for these lifecycle upgrades, competing fan vendors could be locked out of a growing refurbishment pipeline. Conversely, this is a customer opportunity: the Acciona case is a referenceable proof point that EC fan retrofits deliver roughly 70% energy savings and three-year payback, which ebm-papst can use to push EC fan adoption with other data centre operators and with Vertiv itself. Assessment (inference): The broader market signal is that the installed base, not only new-build, is becoming a meaningful demand pool for high-efficiency fans. Retrofits avoid major capital investment and preserve uptime, which lowers the sales barrier in a segment where ebm-papst's EC fan efficiency and controls-integration capability are directly relevant. ebm-papst should expect rising OEM and service-provider interest in fan-level retrofit kits, airflow-on-demand control integration, and documented payback evidence, and should be prepared to support such programmes with validated energy-savings data.

## Full text (original)

Vertiv cooling refurb delivers 70% saving
20th May 2026SPAIN: The modernisation of the cooling infrastructure at the Madrid HQ of sustainable infrastructure solutions company Acciona is said to have delivered a 70% reduction in energy consumption.
The contract, carried out by Vertiv, projected a return on investment in approximately three years, while maintaining full operational continuity.
Following a proactive assessment by Vertiv’s service team, opportunities were identified to further enhance the performance of cooling units that had been operating reliably for over a decade. The goal was clear: increase energy efficiency and available capacity without disrupting operations or compromising availability.
Rather than replacing existing assets, Vertiv says the initiative demonstrated how rethinking the performance of installed infrastructure through a lifecycle and growth‑oriented design approach can unlock significant efficiency gains and future capacity.
The solution focused on upgrading from fixed-speed AC fans to high-efficiency, variable-speed EC fans, integrated with Vertiv Liebert iCOM controls for real-time optimisation of unit components and setpoints. Unlike conventional cooling units operating at constant speed, the upgraded system dynamically adjusts airflow based on actual demand, to enhance system responsiveness and contribute to an extended infrastructure life cycle.
Before full implementation, Vertiv and Acciona validated the solution through a pilot upgrade on two cooling units, confirming projected energy savings and system improvements.
The full modernisation was executed during regular working operations by leveraging the existing N+1 redundancy to enable continuous operations with no downtime. In addition to energy efficiency gains, the optimisation also freed up cooling capacity and available power within the data centre, creating headroom for future IT expansion without requiring major capital investments.