# Sungrow says AIDC storage orders reach 2GWh with over 10GWh in pipeline

- Source: News · Sungrow (T2)
- Published: 2026-09-09
- Score: 65.2
- Tags: Order win, Market data, Datacenter, ESS
- Companies: Sungrow (300274.SZ), NVIDIA
- Original: https://mh2.solarbe.com/news/20260909/50028816.html

## Intelligence brief

### What happened On the conference call following the release of its 2026 interim report, Sungrow (300274.SZ) stated that its AIDC (AI data center) storage business currently holds approximately 2GWh of firm orders, with more than ten gigawatt-hours of projects under active pursuit. The company framed its position in this niche as the cumulative payoff of roughly three decades of capability building in power electronics, storage PCS and grid-forming technology. The article describes AIDC storage as a distinct, high-barrier segment rather than a simple extension of conventional utility-scale storage. Traditional enterprise racks draw roughly 5-8kW, while AI racks have risen to 60-200kW and beyond. With the release of the next-generation Rubin platform, the legacy 415V AC UPS architecture is described as increasingly untenable, and data center power supply is migrating toward an 800V DC hybrid architecture, and eventually toward medium-voltage AC converted in one step to 800V DC via medium-voltage rectifiers or solid-state transformers (SST). In this transition, storage shifts from a backup device to an active regulating unit in the power supply chain, simultaneously handling load smoothing, grid interconnection buffering, demand response and backup support. The article cites NVIDIA's whitepaper on 800VDC next-generation infrastructure architecture, which explicitly proposes a "dual-layer storage architecture," positioning storage as standard equipment in next-generation AI data center power architectures. NVIDIA's new certification boundary is defined on the AC side of the storage system (including PCS), requiring vendors to submit PCS delivery volumes over the past 12 months, EMT models, weak-grid stability validation and capacity expansion plans. ### Key figures - AIDC storage firm orders: approximately 2GWh - Projects under pursuit: more than ten gigawatt-hours (over 10GWh) - Traditional enterprise rack power: typically 5-8kW - AI rack power: 60-200kW and above - AI training and inference power fluctuation: can exceed 50% - Data center grid draw without storage: roughly 40MW to over 70MW during AI power pulses - Grid-side fluctuation with storage connected: compressed to roughly 45-55MW - Traditional storage system availability: typically 99%-99.9% - AIDC storage availability requirement: "five nines" (99.999%), no more than 5 minutes of downtime per year - Traditional storage response time for grid peak shaving: second-level; AIDC storage requires millisecond-level response - Traditional large-scale storage single-cabinet power: typically several hundred kW to 1MW; AIDC storage must support single-rack loads above 220kW - AIDC storage price per watt-hour: over RMB 1.2/Wh, more than 1.5-2x conventional large-scale storage (industry estimate) - PowerTitan 3.0 response time: approximately 20 milliseconds, with GW-level black-start capability - 2025: Sungrow completed full-capacity grid connection of the 7.8GWh Saudi Arabia project, described as the world's largest grid-forming storage project - High-voltage platforms: 1500V/2000V; long-term pre-research on 35kV solid-state transformers ### Why it matters to ebm-papst This is a market signal that the AI data center power chain is being re-architected around 800V DC, high-density racks and system-level storage, with NVIDIA's certification requirements setting a de facto vendor qualification bar on the AC side of storage systems. For ebm-papst, the relevant shift is thermal and airflow management: rack power rising from 5-8kW to 60-200kW+ and single-rack loads above 220kW imply far higher heat densities, tighter temperature control and higher availability requirements ("five nines") than conventional data centers. That tends to raise demand for high-efficiency, high-static-pressure fans and intelligent cooling subsystems, and it favors suppliers that can co-develop with power electronics and storage vendors rather than sell commodity air movers. Assessment (inference): Sungrow's disclosed 2GWh order book and 10GWh+ pipeline suggest AIDC storage is moving from concept to procurement, which could create near-term cooling demand alongside storage cabinets, PCS and SST equipment. Assessment (inference): ebm-papst is not named in this article and no direct competitive overlap with Sungrow is stated; the more plausible opportunity is as a cooling component and subsystem supplier to data center power and storage integrators, including Chinese and global OEMs building 800V DC architectures. Assessment (inference): the barrier described here is electrical and control-related, not thermal, so ebm-papst's exposure depends on whether AIDC storage cabinets and 800V DC power skids adopt higher-density, actively managed cooling, which the article does not specify. Assessment (inference): NVIDIA's certification requirements on PCS delivery volume, EMT models and weak-grid validation could indirectly narrow the supplier field and concentrate demand among a few qualified storage vendors, making early engagement with those vendors more valuable than broad market coverage.

## Full text (English translation)

Title: 2GWh in firm orders, over 10GWh in potential orders: Sungrow "jumps the gun" in AIDC storage

Body (truncated): On the conference call following the release of its 2026 interim report, when asked about AIDC-related business, Sungrow clearly stated that its AIDC storage business currently has approximately 2GWh of firm orders, with more than ten gigawatt-hours of projects under follow-up. Although more and more companies are engaged in the storage business, very few can cut into the AIDC niche segment. Sungrow's competitiveness in the AIDC storage track is essentially the concentrated realization of "capability compounding" in power electronics, storage PCS and grid-forming technology.

The high barriers of AIDC storage

The essence of AIDC storage is not simply moving a storage system into a data center, but rebuilding the power supply architecture for AI infrastructure whose power density is rising sharply. Traditional enterprise racks typically operate in the 5-8kW range, while AI racks have risen to 60-200kW+.

With the release of the new-generation Rubin, the traditional 415V AC UPS architecture can no longer cope with the extremely high power density, severe load fluctuations and stringent reliability requirements of AI data centers. Data center power supply is gradually evolving toward an 800V DC hybrid architecture, and in the future will further move toward a solution in which medium-voltage AC is converted in one step to 800V DC via a medium-voltage rectifier or SST. In this paradigm shift, storage changes from backup equipment to an active regulating unit in the power supply chain, and must simultaneously undertake multiple functions such as load smoothing, grid interconnection buffering, demand response and backup support.

For example, the power fluctuations brought by AI training and inference tasks can exceed 50%, and change quickly, creating shocks for both the grid and the data center's own power supply system. Without storage, the power drawn by a data center from the grid during AI power pulse intervals fluctuates greatly, from about 40MW to over 70MW; with storage connected, grid-side power fluctuations are compressed to roughly the 45-55MW range, and storage absorbs the sudden fluctuations of AI loads inside the data center through charging and discharging.

When rack power enters the range of hundreds of kilowatts to megawatts, the original 415V AC distribution chain shows obvious bottlenecks in copper loss, heat loss, number of conversion stages and instantaneous response, so the data center power supply logic upgrades from a "UPS backup system" to a new paradigm of "high-voltage DC + system-level storage + medium-voltage direct conversion." In its whitepaper "800VDC Next-Generation Infrastructure Architecture," NVIDIA has explicitly proposed a "dual-layer storage architecture," and storage is becoming standard equipment in the power supply architecture of next-generation AI data centers.

Compared with traditional storage, AIDC storage represents an order-of-magnitude improvement in multiple dimensions:

Reliability requirements: traditional storage system availability is usually 99%-99.9%, while AIDC requires "five nines" (99.999%), with no more than 5 minutes of downtime per year.

Response speed: the response time of traditional storage participating in grid peak shaving is measured in seconds, while AIDC storage requires millisecond-level response, completing power support at the instant of grid fluctuation.

Power density: the single-cabinet power of traditional large-scale storage is usually several hundred kilowatts to 1MW, while AIDC storage needs to support high-density loads above 220kW per rack, with higher single-system power requirements.

Technical barriers: AIDC storage needs deep coupling with 800V DC architecture, involving cutting-edge technologies such as SST solid-state transformers, medium-voltage direct connection and high-density modular power supplies. Traditional storage companies lack the technical accumulation in power electronics and high-voltage DC distribution, making it difficult for them to enter.

Therefore, the barriers to the AIDC storage track are extremely high. According to industry estimates, the price per watt-hour of AIDC storage exceeds RMB 1.2/Wh, more than 1.5-2 times that of traditional large-scale storage.

Sungrow's capability compounding

Over the past thirty years, Sungrow's "capability compounding" in power electronics, storage PCS and grid-forming technology is now being concentratedly realized in the new AIDC track.

PV inverters, storage PCS and SST solid-state transformers share highly similar underlying logic - all require combinations of standardized power modules, control units, magnetic components and heat dissipation systems to cover different power levels and application scenarios. The core barriers of all three lie in the coordination of hardware topology design and control algorithms, and Sungrow's existing power electronics platform can directly support the development of AIDC products.

The full-stack in-house development of PCS and EMS is another strong card for Sungrow in entering AIDC storage. The most core power conversion and control capabilities of a storage system come from the storage converter and the energy management system. Sungrow's PCS, after decades of iteration and operational verification in massive global projects, is in the industry's first tier in dimensions such as conversion efficiency, power quality control and equipment reliability; EMS can, through self-developed algorithms, combine grid demand, electricity price signals and other factors to intelligently optimize charging and discharging strategies and maximize project returns.

While other players are still outsourcing core components, Sungrow has already achieved full independent controllability from the "brain" to the "heart" in AIDC storage.

Sungrow's accumulation in grid-forming storage technology is also quite critical. As renewable energy penetration rises, grid stability challenges become increasingly prominent, and traditional "grid-following" storage can no longer meet the demand for active voltage and frequency support in weak-grid environments. Sungrow is one of the earliest companies in China to push grid-forming technology from an academic concept to large-scale application, and its grid-forming PCS/BMS/EMS AC-DC integrated solution is in the global first tier. The active support capability of grid-forming technology in weak-grid and off-grid scenarios is precisely the underlying guarantee for AIDC's "five nines" power supply reliability requirement.

NVIDIA's new certification boundary is clearly set on the AC-side storage system (including PCS), requiring manufacturers to submit PCS delivery volume over the past 12 months, EMT models, weak-grid stability verification, capacity expansion plans, etc., which happens to be Sungrow's strength. Its latest-generation storage platform PowerTitan 3.0 has already embedded "Stem Cell Grid-Forming Technology 2.0," with seamless transition capability between grid-following and grid-forming modes, a response time of about 20 milliseconds, and the ability to smooth computing power surge shocks; it also has GW-level black-start capability, enabling zero-voltage microgrid reconstruction in extreme blackout accidents.

In 2025, Sungrow completed full-capacity grid connection of Saudi Arabia's 7.8GWh project, the world's largest grid-forming storage project, and continues to land projects in complex scenarios in Tibet, Australia, the UK and elsewhere.

A research report by Soochow Securities points out that AIDC storage is not a linear extension of traditional large-scale storage demand, but a new type of power electronics system opportunity born under the triple constraints of "high dynamic load + high reliability power supply + high-voltage DC architecture." The key competitive factors have shifted from "cell integration capability" to PCS dynamic control, grid-forming capability, system-level coordination, scenario-based delivery and customer co-development capability. Sungrow has both global practical accumulation in storage PCS and grid-forming technology, and long-term pre-research on 1500V/2000V high-voltage platforms and 35kV solid-state transformers, as well as the delivery capability for integrated PV-storage solutions, and is essentially closest to the underlying capability combination of "Grid to GPU" required by AIDC.

Conclusion

2GWh in firm orders, over 10GWh in projects under follow-up - behind these numbers is Sungrow's first-mover advantage in the AIDC storage track. It was not "grabbed," but rather the concentrated realization of more than twenty years of capability accumulation in power electronics, storage PCS and grid-forming technology at the right time window.

Competition in AIDC storage is not about whose cells are cheaper, but about who understands the grid better, who understands power electronics better, and who can protect the lifeline of computing power in millisecond-level response. In this sense, Sungrow did not "jump the gun"; it is just that most competitors cannot even get running.

## Full text (original)

在2026年半年报发布后的电话交流会上，当被问及AIDC相关业务时，阳光电源明确表示目前公司AIDC配储业务在手订单约2GWh，跟进中项目有十几个GWh。虽然从事储能业务的企业越来越多，但能切入AIDC这个细分赛道的企业寥寥无几。阳光电源在AIDC储能赛道上的竞争力，本质上是电力电子、储能PCS、构网型技术上“能力复利”的集中兑现。
AIDC储能的高门槛
AIDC储能的本质，不是简单把储能系统搬进数据中心，而是为功率密度急剧跃升的AI基础设施重构供电架构。传统企业级机柜功率常在5-8kW区间，而AI机柜已提升至60-200kW+。
随着新一代Rubin的发布，传统的415V交流UPS架构面对AI数据中心功率密度极高、负载波动剧烈、可靠性要求严苛等考验，已经难以为继。数据中心供电正逐步向800V直流混合架构演进，未来将进一步走向中压交流经中压整流器或SST一步转800V直流方案。在这个范式转换过程中，储能从备用设备变为供电链路中的主动调节单元，需同时承担负荷平滑、并网缓冲、需求响应与备用支撑等多重功能。
例如，AI训练和推理任务带来的功率波动可超过50%，且变化速度快，对电网和自身供电系统都会形成冲击。未配储情况下，数据中心从电网取电的功率在AI功耗脉冲区间会出现从约40MW到70MW以上的大幅波动；接入储能后，电网侧功率波动被压缩至约45-55MW区间，储能通过充放电将AI负载的突发波动消化在了数据中心内部。
当机柜功率进入百千瓦至兆瓦级区间，原有415V交流配电链路在铜耗、热损、转换级数和瞬时响应上都出现明显瓶颈，数据中心供电逻辑因此从“UPS备电体系”升级为“高压直流+系统级储能+中压直转”的新范式。英伟达在《800VDC下一代基础设施架构》白皮书中已明确提出“储能双层架构”，储能正在成为新一代AI数据中心供电架构的标配。
与传统储能相比，AIDC储能在多个维度上都是数量级的提升：
可靠性要求：传统储能系统可用率通常为99%-99.9%，AIDC要求“五个9”（99.999%），一年停机时间不超过5分钟。
响应速度：传统储能参与电网调峰的响应时间以秒级计，AIDC储能需要毫秒级响应，在电网波动瞬间完成功率支撑。
功率密度：传统大储单柜功率通常在数百千瓦至1MW，AIDC储能需要支撑单机柜220kW以上的高密度负荷，单系统功率要求更高。
技术门槛：AIDC储能需要与800V直流架构深度耦合，涉及SST固态变压器、中压直连、高密度模块化电源等前沿技术。传统储能企业缺乏电力电子和高压直流配电的技术积累，难以切入。
所以，AIDC储能赛道的门槛极高。据行业测算，AIDC储能单瓦时价格超过1.2元/Wh，是传统大储的1.5-2倍以上。
阳光电源的能力复利
过往三十年，阳光电源在电力电子、储能PCS、构网型技术上的“能力复利”，正在AIDC这个新赛道中集中兑现。
光伏逆变器、储能PCS与SST固态变压器，底层逻辑高度相通——都需要通过标准化功率模块、控制单元、磁性器件和散热系统的组合，实现不同功率等级与应用场景的覆盖。三者核心壁垒均在硬件拓扑设计与控制算法协同，阳光电源既有的电力电子平台可以直接支撑AIDC产品的开发。
PCS与EMS的全栈自研，则是阳光电源进入AIDC储能的另一张硬牌。储能系统最核心的电能转换与控制能力，来自储能变流器和能量管理系统。阳光电源的PCS经过数十年迭代和全球海量项目的运行验证，在转换效率、电能质量控制、设备可靠性等维度均处于行业第一梯队；EMS则可通过自研算法，结合电网需求、电价信号等实现充放电策略的智能优化，最大化项目收益。
当其他玩家还在外购核心部件时，阳光电源在AIDC储能上已经实现了从“大脑”到“心脏”的全面自主可控。
阳光电源在构网型储能技术上的积累也颇为关键。新能源渗透率攀升后，电网的稳定性挑战日益突出，传统“跟网型”储能已无法满足弱电网环境下的电压和频率主动支撑需求。阳光电源是国内最早将构网型技术从学术概念推向规模化应用的企业之一，其构网型PCS/BMS/EMS交直流一体化方案处于全球第一梯队。构网型技术在弱电网、离网场景中的主动支撑能力，恰好是AIDC对供电可靠性“五个9”要求的底层保障。
英伟达新规认证边界明确设定在交流侧储能系统（含PCS），要求厂商提交过去12个月PCS 交付量、EMT模型、弱电网稳定性验证、扩产计划等，这恰是阳光电源的强项。其最新一代储能平台PowerTitan3.0，已经内嵌“干细胞构网技术2.0”，具备并网跟踪与构网模式无缝过渡能力，响应时间约20毫秒，可平滑算力飙升冲击；同时具备GW级黑启动能力，在极端停电事故下可实现零电压微网重建。
2025年，阳光电源完成了沙特7.8GWh全球最大构网型储能项目全容量并网，并持续在西藏、澳洲、英国等复杂场景落地。
东吴证券研报指出，AIDC储能不是传统大储需求的线性外延，而是“高动态负荷+高可靠供电+高压直流架构”三重约束下诞生的新型电力电子系统机会，关键竞争因素已从“电芯集成能力”转向PCS动态控制、构网能力、系统级协同、场景化交付与客户共研能力。阳光电源既有储能PCS与构网技术的全球实战积累，又拥有1500V/2000V高压平台、35kV固态变压器长期预研、光储一体化方案交付能力，本质上最接近AIDC所需要的“Grid to GPU”的底层能力组合。
结语
2GWh在手订单、超10GWh跟进项目——这组数字的背后，是阳光电源在AIDC储能赛道上的先发优势。它不是“抢”来的，而是过去二十多年在电力电子、储能PCS、构网型技术上的能力积累在恰当时间窗口的集中兑现。
AIDC储能的竞争，比的不是谁的电芯更便宜，而是谁更懂电网、谁更懂电力电子、谁能在毫秒级的响应中守住算力的生命线。从这个意义上说，阳光电源并没有“抢跑”，只是多数竞争对手跑不起来。