# Hiwave unveils China's first large-scale modular liquid-cooling data center at Shanghai liquid cooling forum

- Source: Hiwave News (T1)
- Published: 2026-09-11
- Score: 38.0
- Tags: Datacenter, Product launch
- Companies: Hiwave
- Original: https://www.haiwu.com/news/dynamic/2136.html

## Intelligence brief

### What happened Hiwave (Haiwu Technology) presented at the 3rd China International Liquid Cooling Technology Innovation and Development Forum, held in Shanghai on 10–11 September 2026. The forum was hosted by Thermal Craftsman with Battery Craftsman as co-host, and focused on data center cooling upgrades and industrial ecosystem coordination in the AI era. Participants spanned the liquid cooling value chain, including liquid-cooled servers, CDUs, cold plates, pumps and valves, piping, and intelligent control systems, with discussions on immersion cooling, CDU architecture iteration, and high-power cold plate heat dissipation. On 11 September, 11:55–12:20, Hiwave's Wang Shun delivered a keynote titled "Hiwave Liquid Cooling Technology Innovation and Practice." He presented what the company describes as China's first large-area modular liquid-cooling data center, covering structural design, production model, quality control, extreme-condition adaptability, and multi-scenario full-stack liquid cooling solutions. Hiwave positions liquid cooling not as a simple stacking of cold plates and CDUs but as an end-to-end system engineering problem spanning outdoor cooling sources, primary piping networks, CDU distribution units, secondary piping, liquid-cooled racks, cold plates, water quality control, and intelligent control strategies. The company outlined four scenario-based solutions: retrofit of existing rooms (modular CDU plus heat-exchange isolation architecture, enabling non-stop air-to-liquid upgrades), new AIDC parks (early design involvement, maximizing free cooling), micro-module/containerized compute (prefabricated integration), and progressive upgrades (from airflow optimization to localized high-density liquid cooling and eventually full-domain liquid cooling). ### Key figures - Forum dates: 10–11 September 2026, Shanghai. - Hiwave keynote slot: 11 September, 11:55–12:20. - Target PUE: below 1.1, versus traditional air cooling. - Factory-completed production processes: more than 90% of total work, with on-site work limited to assembly and connection. - Delivery cycle reduction: more than 50% for micro-module/containerized compute scenarios. - Floor space reduction: 40%–60% in the same scenarios. - Quality system: SOP/SIP full-process control, dual-person review at key processes, third-party acceptance, certified personnel. - No specific investment amounts, capacity figures, order volumes, or customer names were disclosed. ### Why it matters to ebm-papst Hiwave is publicly claiming a first-mover position in large-scale, replicable modular liquid-cooling data centers in China, explicitly targeting AI high-density compute loads and PUE below 1.1. This is a direct signal that the Chinese data center cooling market is shifting from pilot projects toward industrialized, prefabricated deployment — a shift that compresses the addressable market for conventional air-cooling components, including precision cooling fans and air movers, in new-build AI data centers. At the same time, liquid cooling does not eliminate air movement: CDUs, secondary loops, heat rejection units, and hybrid air-liquid rooms still require fans, pumps, and intelligent airflow control, and retrofit scenarios (air-to-liquid transition without downtime) keep existing air-cooled infrastructure in service longer. Hiwave's emphasis on full-stack system integration, water quality control, and intelligent regulation also implies that component suppliers must integrate into system-level design rather than sell standalone parts. Assessment (inference): ebm-papst should treat Hiwave as both a competitive signal and a potential channel partner. Its modular, prefabricated architecture could become a reference design for Chinese AIDC projects, and early engagement on fan, blower, and control solutions for CDU and heat rejection subsystems may be more valuable than defending purely air-cooled positions. Assessment (inference): the stated PUE below 1.1 and 50%+ delivery compression are vendor claims not independently verified here, so they should be validated against actual project references before being used in competitive positioning.

## Full text (English translation)

Scale deployment begins a new journey; liquid-cooling room heat dissipation builds a green computing foundation | Hiwave appears at the 3rd China International Liquid Cooling Technology Innovation and Development Forum

On 10–11 September, the 2026 3rd China International Liquid Cooling Technology Innovation and Development Forum was held in Shanghai. The forum was hosted by Thermal Craftsman and co-hosted by Battery Craftsman, focusing on data center cooling technology upgrades and industrial ecosystem coordination in the AI era. It gathered core players across the entire liquid cooling industry chain, including liquid-cooled servers, CDUs, cold plates, pumps, valves and piping, and intelligent control systems, and conducted in-depth discussions on key directions such as immersion liquid cooling, CDU architecture iteration, and high-power cold plate heat dissipation, jointly exploring the evolution path and commercialization model of liquid cooling technology against the backdrop of exploding computing power demand.

At present, the rapid iteration of the artificial intelligence industry is driving continuously surging computing power demand. The large-scale deployment of high-power AI servers poses unprecedented challenges to data center cooling capacity, energy consumption control, and space utilization. Developing efficient liquid cooling technology and promoting the green and low-carbon transformation of computing infrastructure is not only an inherent requirement for building new digital infrastructure, but also a key lever for implementing the national dual carbon goals, cultivating new quality productive forces, and achieving sustainable development of the digital economy. However, the industry generally faces practical obstacles: liquid cooling mostly remains at the pilot verification stage, on-site construction is complex, later maintenance is difficult, and adaptation to complex environments is insufficient. How to achieve the leap of liquid cooling from scattered pilots to large-scale, replicable commercial deployment has become a core issue urgently needing to be tackled by the entire industry.

On 11 September, 11:55–12:20, Hiwave's Wang Shun delivered a keynote speech titled "Hiwave Liquid Cooling Technology Innovation and Practice" at the forum. Addressing industry chain colleagues, he focused on sharing the innovative achievements of China's first large-area liquid-cooling modular data center, providing in-depth interpretation around structural design, production mode, quality control, extreme working condition adaptation, and multi-scenario full-stack liquid cooling solutions, and outputting implementation experience that combines technical advancement with engineering feasibility.

This large-area liquid-cooling modular data center breaks the industry status quo where liquid cooling technology is mostly limited to small-batch pilots and laboratory verification, creating a complete solution that can be replicated in batches and delivered and deployed quickly. Compared with traditional air cooling systems, its heat dissipation capacity is greatly improved, perfectly adapting to the ultra-high-density computing loads of AI intelligent computing centers; it pushes data center PUE toward below 1.1, effectively reducing carbon emissions of computing infrastructure and practicing the concept of green development; at the same time, it greatly improves rack deployment density, releasing more computing power in limited physical space, saving machine room land and space resources, and serving the intensive construction of China's digital infrastructure.

In response to the four core pain points of industry implementation, Hiwave has completed systematic innovation breakthroughs. First, it innovated a detachable skylight and floor shelter structure, with liquid cooling piping prefabricated in the factory, requiring only connection work on site, reducing on-site welding and cutting, and achieving efficient deployment; later maintenance and hardware iteration do not require destroying the main body of the shelter, enabling flexible maintenance and upgrades and improving the economics of the project's full life cycle. Second, it replaced the traditional on-site engineering model with standardized productized production. All shelters implement unified specifications, processes, and acceptance standards, avoiding quality differences caused by on-site construction; the factory completes more than 90% of production processes, with only assembly and connection done on site, significantly compressing the construction cycle. Third, it established a complete SOP/SIP quality control system, with dual-person review implemented at key processes, promoting a dual-person review plus third-party acceptance mechanism, building a complete full-process SOP/SIP control system, implementing dual-person review at key processes, introducing a third-party acceptance mechanism, and requiring post personnel to hold certificates, solidifying the quality bottom line for batch delivery. This mature quality control system can also provide a reusable management model for similar projects in the industry. Fourth, facing complex regional working conditions such as sandstorms and large temperature differences, it strengthened shelter sealing and anti-corrosion, packaging protection, and anti-vibration and anti-impact design, completing multiple rounds of rigorous simulation tests for impact, vibration, and sand dust, expanding the applicable regions for liquid cooling computing facilities and better supporting the cross-regional computing power layout of the East Data West Computing project.

Hiwave believes that liquid cooling is not equal to a simple stacking of components such as cold plates and CDUs, but a complex system engineering with end-to-end coordination. From outdoor cooling sources, primary pipe networks, CDU distribution units, secondary piping, liquid-cooled racks, and cold plates, to water quality control and intelligent regulation strategies, any mismatched parameter in any link will cause local overheating, energy efficiency degradation, and operational risks. There is no universal one-size-fits-all solution; customized system design must be done in combination with computing load, site conditions, and long-term expansion plans.

Based on this system engineering methodology, Hiwave has built full-stack liquid cooling solutions covering multiple business scenarios:
Existing machine room retrofit scenario: relying on modular CDUs and heat exchange isolation architecture, with zoned dynamic regulation, it supports smooth completion of air cooling to liquid cooling upgrades without business downtime, protecting customers' existing IT assets; New AIDC intelligent computing park scenario: early involvement in planning and design, maximizing the use of natural cooling sources, and building a liquid cooling computing foundation oriented toward future iteration; Micro-module/containerized computing scenario: highly integrated and prefabricated, shortening project delivery cycles by more than 50%, reducing machine room floor area by 40%-60%, and enabling on-demand elastic expansion of computing power; Progressive upgrade scenario: gradually transitioning from airflow optimization and localized high-density rack liquid cooling retrofits to full-domain liquid cooling, helping customers balance investment costs and business returns.

The wave of the computing era surges forward, and green and low-carbon development is the inevitable path for new data centers. In the future, Hiwave will continue to deepen liquid cooling technology research and engineering practice, adhere to the development approach of productization, scale, and full life cycle, polish more reliable and economical liquid cooling infrastructure products, join hands with upstream and downstream industry chain partners to build a healthy industrial ecosystem, and use technological innovation to support the high-quality and low-carbon development of China's digital infrastructure, solidifying the computing foundation for the vigorous development of the digital economy.

## Full text (original)

9 月 10‑11 日，2026 第三届中国国际液冷技术创新发展论坛于上海举办。本次论坛由热能工匠主办、电池工匠联合主办，聚焦 AI 时代数据中心散热技术升级与产业生态协同，汇聚液冷服务器、CDU、液冷板、泵阀管路、智能控制系统等全产业链核心主体，围绕浸没式液冷、CDU 架构迭代、高功率冷板散热等关键方向开展深度研讨，共同探寻算力爆发背景下液冷技术的演进路径与商业化落地模式。
当前，人工智能产业高速迭代带动算力需求持续激增，高功耗 AI 服务器大规模部署，对数据中心散热能力、能耗管控、空间利用率提出前所未有的挑战。发展高效液冷技术，推动算力基础设施绿色低碳转型，既是建设新型数字基建的内在要求，也是落实国家双碳目标、培育新质生产力、实现数字经济可持续发展的关键抓手。但行业普遍面临液冷多停留在试点验证、现场施工复杂、后期维护难度大、复杂环境适配不足等现实阻碍，如何实现液冷从零星试点向大面积、可复制的规模化商用跨越，成为全行业亟待攻克的核心课题。
9 月 11 日 11:55‑12:20，海悟王舜在论坛带来《海悟液冷技术创新与实践》主题演讲，面向产业链同仁，重点分享国内首个大面积液冷模块化数据中心创新成果，围绕结构设计、生产模式、质量管控、极端工况适配以及多场景全栈液冷解决方案展开深度解读，输出兼具技术先进性与工程可行性的落地经验。
该大面积液冷模块化数据中心，打破行业液冷技术多局限小批量试点、实验室验证的现状，打造可批量复制、快速交付落地的完整解决方案。相较传统风冷体系，散热能力大幅提升，完美适配 AI 智算中心超高密度算力负载；推动数据中心 PUE 向 1.1 以下迈进，有效降低算力基础设施碳排放，践行绿色发展理念；同时大幅提升机柜部署密度，在有限物理空间释放更大算力，节约机房土地与空间资源，服务我国数字基建集约建设。
针对行业落地的四大核心痛点，海悟完成体系化创新突破。 第一，创新可拆卸天窗与地板方舱结构，液冷管路工厂预制，现场仅需对接作业，减少现场焊接切割，实现高效部署；后期检修、硬件迭代无需破坏方舱主体，实现灵活维护与升级，提升项目全生命周期经济性。 第二，以标准化产品化生产替代传统现场工程模式，全部方舱执行统一规格、工艺与验收标准，规避现场施工带来的质量差异；工厂完成 90% 以上生产工序，现场仅做拼装对接，显着压缩建设周期。 第三，建立完整 SOP/SIP 质量管控体系，关键工序执行双人复核，推行双人复核 + 三方验收机制，搭建完整的全流程 SOP/SIP 管控体系，关键工序落实双人复核，引入第三方验收机制，岗位人员持证上岗，筑牢批量交付的品质底线，这套成熟的质量管控体系，也可为行业同类项目提供可复用管理范本。 第四，面向风沙、温差大等复杂地域工况，强化方舱密封防腐、包装防护、抗振抗冲击设计，完成冲击、振动、沙尘多轮严苛模拟测试，拓展液冷算力设施的适用地域，更好支撑东数西算跨区域算力布局。
海悟认为，液冷不等于冷板、CDU 等零部件简单叠加，而是一套端到端协同的复杂系统工程。从室外冷源、一次管网、CDU 分配单元、二次管路、液冷机柜、液冷板，到水质管控、智能调控策略，任一环节参数失配，都会引发局部过热、能效衰减、运维风险。不存在万能通用方案，必须结合算力负载、现场条件、远期扩容规划，做定制化系统设计。
基于这套系统工程方法论，海悟打造覆盖多业务场景的全栈液冷解决方案：
存量机房改造场景：依托模块化 CDU、换热隔离架构，分区动态调控，支持业务不停机平滑完成风冷向液冷升级，保护客户原有 IT 资产； 新建 AIDC 智算园区场景：早期介入规划设计，最大化利用自然冷源，搭建面向未来迭代的液冷算力底座； 微模块 / 集装箱算力场景：高度集成预制化，项目交付周期缩短 50% 以上，机房占地面积降低 40%-60%，算力按需弹性扩容； 渐进式升级场景：从气流优化、局部高密机柜液冷改造，逐步过渡到全域液冷，帮助客户平衡投入成本与业务收益。
算力时代浪潮奔涌，绿色低碳是新型数据中心发展的必由之路。未来，海悟将持续深耕液冷技术研发与工程实践，坚持产品化、规模化、全生命周期的发展思路，打磨更加可靠、经济的液冷基础设施产品，联动产业链上下游共建良性产业生态，以技术创新助力我国数字基建高质量、低碳化发展，为数字经济蓬勃发展夯实算力根基。