# Newsome swaps two R407C rooftop chillers for Trane R454B units at York hospital, cutting power 28%

- Source: Cooling Post (T2)
- Published: 2026-09-08
- Score: 44.9
- Tags: HVAC, Retrofit
- Companies: Trane Technologies, Johnson Controls
- Original: https://www.coolingpost.com/features/trane-r454b-chillers-give-hospital-a-lift/

## Intelligence brief

### What happened UK contractor Newsome, based in Yorkshire and founded in 1973, replaced two ageing rooftop air-cooled chillers serving the main air handling unit cooling circuit at a hospital in York. The work was reported by Cooling Post on 8 September 2026. The project followed an energy and performance review of the existing system, which identified an opportunity to improve efficiency, resilience and long-term reliability. The original installation comprised two York YAES 0415 air-cooled chillers running on R407C. One of the two units had already failed, while the remaining chiller continued to support the site. Because the system serves a critical hospital environment, the replacement programme had to be planned around live operations and completed with minimal disruption. Newsome compared the existing chillers against current high-efficiency alternatives, and also assessed the potential benefits of adiabatic spray systems so the site team could weigh upgraded existing equipment against a full chiller replacement. Two Trane Sintesis Advantage CGAF 105 HE LN air-cooled chillers were selected. The failed chiller was disconnected first; the main lifting operation was then scheduled for a weekend to limit disruption to normal hospital activity. During the lift, the remaining chiller was isolated and disconnected before both existing units were removed from the roof and the new chillers positioned. The work was phased so the first replacement chiller could be connected and commissioned before the second unit was completed. ### Key figures - Two existing York YAES 0415 air-cooled chillers, using R407C refrigerant, were replaced. - One of the two original chillers had already failed; the other was still supporting the site. - Two Trane Sintesis Advantage CGAF 105 HE LN air-cooled chillers were installed. - Each new chiller provides approximately 395 kW of nominal cooling. - Each new chiller incorporates two independent refrigeration circuits. - The new system was assessed to reduce annual power consumption by approximately 28% across the two units. - A detailed single-unit comparison indicated an estimated efficiency improvement of around 33% under the assessed operating profile. - The new units use R454B refrigerant. - Newsome was founded in 1973. - No project value, contract sum, delivery lead time or refrigerant charge figures were disclosed. ### Why it matters to ebm-papst This is a refrigerant-transition and chiller-retrofit signal in the UK healthcare segment, a vertical where resilience and uninterrupted operation outweigh first-cost considerations. The shift from R407C to R454B in a live hospital environment confirms that lower-GWP refrigerant adoption is now being executed in operational, mission-critical buildings rather than only in new-build projects. Assessment (inference): Chiller replacement at this scale typically pulls through associated air-moving content, including condenser and evaporator fan assemblies, EC motors and drives, so each completed retrofit represents a component opportunity even when ebm-papst is not the chiller OEM. Assessment (inference): The stated 28% system-level and roughly 33% single-unit efficiency gains suggest that fan and motor efficiency, not only compressor and refrigerant performance, is a meaningful part of the value proposition being sold to end users, which favours suppliers with high-efficiency EC fan platforms. Assessment (inference): Trane is a direct competitor in the chiller space but also a potential channel for ebm-papst air-moving products, so this project is best read as both a competitive datapoint and a demand indicator. Assessment (inference): The UK hospital estate contains a large installed base of ageing R407C rooftop chillers, and the phased, weekend-scheduled replacement model demonstrated here is likely to be repeated, making healthcare retrofit a durable near-term demand signal for replacement air-moving components and aftermarket service.

## Full text (original)

Trane R454B chillers give hospital a lift
8th September 2026UK: Yorkshire-based contractor Newsome has replaced two ageing rooftop chillers with units using R454B refrigerant to serve the main air handling unit cooling circuit at a hospital in York.
The project followed an energy and performance review of the existing system, which identified a clear opportunity to improve efficiency, resilience and long-term reliability.
The original installation used two York YAES 0415 air-cooled chillers using R407C. One unit had already failed, while the remaining chiller was continuing to support the site.
As the system served a critical hospital environment, the replacement programme had to be carefully planned around live operations and completed with minimal disruption.
Newsome carried out a detailed comparison between the existing chillers and current high-efficiency alternatives. The analysis showed that the new system could reduce annual power consumption by approximately 28% across the two units, with the detailed single-unit comparison indicating an estimated efficiency improvement of around 33% under the assessed operating profile.
The potential benefits of adiabatic spray systems were also assessed, allowing the site team to compare the performance of upgraded existing equipment against a full chiller replacement.
Two Trane Sintesis Advantage CGAF 105 HE LN air-cooled chillers were selected, each capable of providing approximately 395kW of nominal cooling. Each chiller incorporates two independent refrigeration circuits, providing additional resilience and helping reduce the impact of any future maintenance requirement.
The failed chiller was disconnected first. The main lifting operation was then scheduled for a weekend to reduce disruption to normal hospital activity. During the lift, the remaining chiller was isolated and disconnected before both existing units were removed from the roof and the new chillers positioned. The work was phased so that the first replacement chiller could be connected and commissioned before the second unit was completed.
Founded in 1973, Newsome is one of the most experienced specialists in the delivery of industrial temperature and humidity control solutions.
This includes specialist rental and maintenance services to a wide range of industries including food and drink, plastics, chemicals, general manufacturing, leisure, building services and pharmaceutical production.