Johnson Controls launches second AI factory cooling guide, targeting 1-GW air-cooled data centers with 50 MW power return
聚合·JCIT22026-05-05 · INTL · Johnson Controls 江森自控
新品技术发布数据中心/IT散热商用暖通
▾ 1 条同事件报道

情报详报

What happened Johnson Controls (NYSE: JCI) published its second AI Factory Reference Design Guide on May 5, 2026, announced from Milwaukee via PRNewswire. The new guide focuses on air-cooled chiller architectures for data centers, following the company's water-cooled chiller guide released in February 2026. According to the release, the guide is positioned as part of what Johnson Controls describes as the industry's most comprehensive set of global design guides mapping the full data center thermal chain. Additional guides covering absorption chillers and direct-to-chip liquid cooling are stated to follow. The design blueprint targets scalable data center designs up to a 1-GW AI factory using air-cooled chillers. It outlines a thermal cooling architecture integrating high-efficiency air-cooled YORK centrifugal chillers (including the YDAM and YVAM models), fan coil walls (FCWs) and coolant distribution units (CDUs) to manage both air- and liquid-cooled IT loads. The guide provides sizing references for 220 MW compute clusters, including recommended design temperatures and operating conditions across each stage of the thermal chain. Johnson Controls frames the guide as a response to operator challenges including cooling power demand, rising cooling-loop temperatures, efficiency losses from heat islands, and limited water availability. Austin Domenici, president of Johnson Controls Global Data Center Solutions, said gigawatt-scale AI factories require a fundamentally different approach to infrastructure planning. ### Key figures - Design scalability: up to a 1-GW AI factory using air-cooled chillers - Sizing references provided for 220 MW compute clusters - 50 MW returned to the AI factory through bifurcated loops for air- and liquid-cooling systems - 32% improvement in annual energy consumption via intelligent utilization of redundant chillers - 20 MW peak power savings by quantifying and mitigating heat island effects of air-cooled chiller plants - Zero water usage saving over 12 million gallons daily by eliminating cooling towers for facility water - 30% Coefficient of Performance (COP) improvement and 27% fewer chillers from raising chilled water temperature to support warm-water Technology Cooling System (TCS) loops - First guide (water-cooled chillers) released February 2026; absorption chiller and direct-to-chip liquid cooling guides to follow - Johnson Controls company history cited as more than 140 years ### Why it matters to ebm-papst This is a competitive and market-signal event rather than a direct customer transaction. Johnson Controls is staking out a system-level position in AI data center thermal management, publishing reference architectures that specify chillers, FCWs, CDUs and loop configurations. Reference designs shape procurement: once operators and design firms adopt a published blueprint, component selection downstream tends to follow the specified architecture. Assessment (inference): The explicit air-cooled orientation is the most relevant signal for ebm-papst. Air-cooled chiller plants and fan coil walls are fan-intensive, and a guide that scales to 1 GW implies very large aggregate fan content per deployment. If Johnson Controls' air-cooled pathway gains traction against water-cooled designs, demand for high-efficiency EC fans and fan arrays in chiller, FCW and CDU applications should rise accordingly. Assessment (inference): The stated 20 MW peak power savings from mitigating heat island effects and the 32% annual energy consumption improvement point to airflow management and fan efficiency as levers Johnson Controls is actively quantifying. That creates an opening for ebm-papst to position EC fan technology as an enabler of those published outcomes, particularly where the guide specifies design temperatures and operating conditions across the thermal chain. Assessment (inference): The pending direct-to-chip liquid cooling guide is a watch item. Liquid cooling reduces some air-moving content but increases demand for CDU-integrated fans, pumps and heat rejection equipment, so the net effect on ebm-papst's addressable content is uncertain and depends on the final architecture. The zero-water and warm-water TCS direction also suggests growing emphasis on heat rejection efficiency, where fan performance is a differentiating factor. Assessment (inference): ebm-papst should treat Johnson Controls as both a potential channel partner and a competing system integrator whose specifications can lock in supplier choices early. Engaging at the reference-design stage, before blueprints harden into procurement lists, is likely more valuable than responding to tenders later.

原文全文

- Johnson Controls - Media Center - Second data center reference design guide Johnson Controls releases second data center reference design guide to advance industrial‑scale AI factory cooling - A globally repeatable blueprint for cooling gigawatt‑scale AI factories efficiently and sustainably - Supports zero‑water cooling, eliminating cooling towers and saving 12+ million gallons of water per day. - Enables high-efficiency air-cooled designs that can return up to 50 MW to the AI factory and improve annual energy consumption by 32% MILWAUKEE, May 5, 2026 /PRNewswire/ -- Johnson Controls (NYSE: JCI), a global leader in thermal management, mission-critical building systems, energy efficiency, and decarbonization, is expanding its AI Factory Reference Design Guides with the launch of its second guide, focused on air-cooled chillers. Building on the company's water‑cooled chiller guide released in February, this latest blueprint marks the next step in what will be the industry's most comprehensive set of global design guides mapping the full data center thermal chain — with additional guides covering absorption chillers and direct‑to‑chip liquid cooling to follow. As AI brings new scale and complexity to data center design, operators are facing mounting challenges including the power needed for cooling systems, rising cooling‑loop temperatures, efficiency losses from heat islands and limited water availability. Johnson Controls' AI Factory Reference Design Guide Series addresses this challenge by outlining how designers and operators can achieve industry‑leading energy and water efficiency and minimize noise impact on surrounding communities while remaining adaptable to different climates, workloads and growth paths. The new guide supports the scalable design of data centers of all sizes, up to a 1-GW AI factory, utilizing air-cooled chillers. It outlines a comprehensive thermal cooling architecture that integrates high‑efficiency air-cooled YORK centrifugal chillers (including its YDAM and YVAM chillers), fan coil walls (FCWs) and coolant distribution units (CDUs) to manage both air‑ and liquid‑cooled IT loads. The guide provides sizing references for 220MW compute clusters, including recommended design temperatures and operating conditions across each stage of the thermal chain. Key outcomes enabled by the design guide include: - 50MW returned to the AI factory through the implementation of bifurcated loops for air- and liquid- cooling systems. - 32% improvement in annual energy consumption through the intelligent utilization of redundant chillers. - 20MW peak power savings by quantifying and mitigating heat island effects of air-cooled chiller plants. - Zero water usage saves over 12 million gallons daily by eliminating the need for cooling towers to produce facility water. - 30% Coefficient of Performance (COP) improvement and 27% fewer chillers from raising the chilled water temperature to support warm-water Technology Cooling System (TCS) loops. "At gigawatt scale, AI factories require a fundamentally different way of thinking about infrastructure," said Austin Domenici, president, Johnson Controls Global Data Center Solutions. "The future requires designing integrated systems that can scale predictably, perform efficiently and adapt as technology evolves. This guide reflects how Johnson Controls helps customers plan holistically for AI growth, from design to operations, anywhere in the world." Learn more about Johnson Controls's Reference Guide Series at www.johnsoncontrols.com/industries/data-centers/reference-designs. MEDIA CONTACTS: Louise Colledge +4179 414 4996 Email: louise.colledge@jci.com About Johnson Controls: Johnson Controls, a global leader in thermal management, mission-critical building systems, energy efficiency, and decarbonization, helps customers use energy more productively, reduce carbon emissions, and operate with the precision and resilience required in rapidly expanding industries such as data centers, healthcare, pharmaceuticals, advanced manufacturing, and higher education. For more than 140 years, Johnson Controls has delivered performance where it really matters. Backed by advanced technology, lifecycle services and an industry-leading field organization, we elevate customer performance, turn goals into real-world results and help move society forward. Visit johnsoncontrols.com for more information and follow @Johnsoncontrols on social platforms. SOURCE Johnson Controls International plc