AI算力液冷产业链深度研究报告:GPU功耗爆发驱动液冷渗透率加速提升

China Liquid Cooling Report: AI GPU Racks Hit 120kW+, Market to Top RMB 60B by 2030, Envicool Leads
市场数据/研究数据中心/IT散热

情报详报

What happened On 20 May 2026, a Chinese-language industry research report titled "AI Computing Power -- Deep Dive into the Liquid Cooling Supply Chain" was published and aggregated, with Envicool (Shenzhen-listed, 002837) cited as the source context. The report is a market and supply-chain study of liquid cooling for AI data centers, covering technology routes, core components, the industry chain map, global and China market sizing, vendor landscapes, domestic substitution progress, demand drivers, investment targets and risks. The report's central claim is that liquid cooling has become the mandatory thermal solution for high-power AI GPUs. It states that NVIDIA's GB200 NVL72 rack draws 120kW+ and that traditional air cooling can no longer meet the requirement, with liquid cooling penetration rising from 15% in 2024 toward more than 50% by 2027. It identifies three technology routes -- cold plate, immersion and spray -- and names Envicool, Gaolan (Gaolan Shares), Tongfei, Yimikang, Canatal and Shenling Environment among Chinese suppliers, alongside Vertiv, CoolIT, Boyd, 3M, Schneider Electric, Staubli, CPC and Parker internationally. The document also includes promotional material for a humanoid-robot joint motor event, which is unrelated to the liquid cooling analysis. ### Key figures - Global data center liquid cooling market: RMB 6.0bn (2022), RMB 10bn (2023), RMB 15bn (2024E), RMB 22bn (2025E), RMB 32bn (2026E), RMB 48bn (2028E), RMB 60bn+ (2030E); CAGR >20% - China liquid cooling market: RMB 1.5bn (2022), RMB 3.0bn (2023), RMB 5.0bn (2024E), RMB 8.0bn (2025E), RMB 12bn (2026E), RMB 24bn (2030E); CAGR ~25% - Liquid cooling penetration: 15% (2024) to >50% (2027); GB200 generation >70%; GB300 generation ~100% - Rack power: air cooling 20-30kW; closed hot/cold aisle 30-40kW; cold plate 60-100kW; single-phase immersion >100kW; two-phase immersion >200kW - GPU roadmap: A100 400W (2020), H100 700W (2022), H200 700W (2024), GB200 1,200W with NVL72 at 120kW+, GB300 1,400W+ with NVL144 at 250kW+, Rubin >1,500W (2027E) - Technology mix: cold plate >70% today, falling to 60% by 2030; immersion rising from 10% (2024E) to 40% (2030E) - Component cost share (2025): CDU 25%, cold plate 22%, manifold 15%, quick connectors 8%, coolant 5%, system integration and services 25% - Domestic substitution rates (2024E to 2027E): system integration ~35% to ~50%; CDU ~30% to ~45%; cold plate ~40% to ~55%; quick connectors ~25% to ~40%; fluorinated coolant <5% to ~15%; pumps/high-end valves ~30% to ~45% - 3M holds >70% of the immersion coolant market; its Novec patent expiry could cut immersion costs by 30-50% - Envicool revenue ~RMB 6bn versus Vertiv >RMB 50bn; Envicool liquid cooling growth >50%; Envicool domestic AI liquid cooling share >40% - Tongfei has invested RMB 300m in a liquid cooling temperature-control project - PUE: air cooling 1.3-1.5; cold plate 1.1-1.2; single-phase immersion 1.05-1.1; two-phase immersion <1.05 ### Why it matters to ebm-papst This report frames liquid cooling as the default thermal architecture for AI data centers, which is a direct structural signal for ebm-papst's data center cooling business. The report explicitly states that traditional air cooling cannot serve racks above roughly 40kW and that GB200-class racks at 120kW+ require liquid cooling. If that trajectory holds, the addressable market for conventional precision-air-cooling fans and air movers in new AI halls shrinks in relative terms, while demand shifts toward liquid-cooling infrastructure: CDUs, manifolds, heat exchangers and dry coolers. Assessment (inference): ebm-papst's most immediate exposure is not the cold plate or GPU-adjacent components, where the report names CoolIT, Boyd, AAVID, Envicool and Gaolan, but the heat-rejection side of the loop -- CDU pumps and fans, coolant circulation, and the external cooling tower or dry cooler that rejects heat from a centralized liquid loop. The report notes that centralized liquid cooling for multi-hundred-MW AI campuses is becoming standard, which increases the number of large air-moving and heat-exchange assemblies per site even as per-rack air cooling content falls. Assessment (inference): the report's vendor tables list no fan or air-movement supplier at all, which suggests either that air movers are treated as commodity sub-components inside CDUs and dry coolers, or that the report's scope simply excludes them. Either reading argues for ebm-papst to position itself explicitly with CDU and system-integration vendors -- Envicool, Gaolan, Tongfei, Yimikang, Vertiv, CoolIT, Schneider Electric -- rather than only with server OEMs. Assessment (inference): the report's claim that Chinese suppliers already cover CDU, cold plate and quick connectors, and are pushing into pumps and high-end valves, is a medium-term competitive signal. If Chinese CDU and pump localization advances as projected (roughly 30% to 45% by 2027), European and Japanese component suppliers, including ebm-papst, could face price pressure in the China market and in Chinese-built export projects. The countervailing opportunity is the immersion route, where the report expects commercialization to accelerate after 2027 and where coolant, sealing and heat-rejection engineering requirements are higher. Assessment (inference): the report is a sell-side-style equity research document with explicit stock recommendations and star ratings, so its market forecasts and share estimates should be treated as directional rather than audited. The 2030 figures are marked as estimates (E) throughout, and no primary source or methodology is disclosed. ebm-papst should validate the rack-power and penetration assumptions against its own OEM and hyperscaler contacts before using them in planning.

原文全文

原文 英文翻译
AI算力产业链深度研究报告 液冷产业链专题 液冷:AI算力的“散热命脉”,GPU功耗爆发下的源确定性增量 一、执行摘要 【核心观点】 液冷散热是AI数据中心应对高功耗GPU的核心解决方案,涵盖冷板式、浸没式、喷淋式三大技术路线。NVIDIA GB200 NVL72单柜功耗达120kW+,传统风冷已无法满足散热需求,液冷渗透率从2024年的15%向2027年的>50%加速提升。中国厂商在冷板式液冷领域已具备全球竞争力,英维克、高澜股份等厂商在超大型数据中心项目中已获得订单。 【五大要点】 1. 全球数据中心液冷市场2025年预计超过200亿元,AI驱动下2030年突破600亿元,CAGR>20% 2. 冷板式液冷是当前主流,占比>70%;浸没式是未来方向,2027年后加速商用化 3. NVIDIA GB200/GB300等新一代GPU平台强制要求液冷,单柜功耗从40kW跃升至120kW+,直接拉动液冷采购 4. 中国厂商在CDU、冷板、快接头等核心部件上已具备全球供应能力,英维克是全球液冷龙头 5. 主要风险:液冷工艺标准未统一、浸没式商用化进度不确定、工质泄漏风险 二、技术概述 2.1 数据中心散热技术演进 数据中心散热技术随单柜功耗持续提升而演进,从传统风冷迈向液冷。AI GPU功耗的爆发式增长是核心驱动力。 | 散热技术 | 散热介质 | 单柜最大制冷量 | 典型PUE | 成本指数 | 适用场景 | | 传统风冷(精密空调) | 空气 | 20-30kW/柜 | 1.3-1.5 | 1x(基准) | 传统数据中心、中低功耗服务器 | | 冷热通道封闭 | 空气+先进风道 | 30-40kW/柜 | 1.2-1.4 | 1.2x | 中高功耗服务器、过渡方案 | | 冷板式液冷 | 水/乙二醇溶液+冷板 | 60-100kW/柜 | 1.1-1.2 | 1.5-2.5x | AI服务器、高功耗GPU | | 浸没式液冷(单相) | 绝缘液体(氟化液) | >100kW/柜 | 1.05-1.1 | 2-4x | 超大型AI集群、超算中心 | | 浸没式液冷(双相) | 绝缘液+沸点制冷 | >200kW/柜 | <1.05 | 3-5x | 下一代超大型AI集群 | 2.2 三大液冷技术路线对比 | 对比维度 | 冷板式液冷 | 浸没式液冷(单相) | 浸没式液冷(双相) | | 散热原理 | 冷板接触GPU表面,液体带走热量 | GPU直接浸泡在绝缘液体中散热 | 绝缘液沸腾相变取热+冷凝回流 | | 散热能力 | 60-100kW/柜 | >100kW/柜 | >200kW/柜 | | 改造难度 | 较低(可改造现有服务器) | 高(需专用浸没设备) | 极高(需完全新建) | | 商用成熟度 | ★★★★★(大规模部署) | ★★★(小规模商用) | ★★(主要在超算) | | 工质要求 | 水/乙二醇溶液(普通) | 氟化液(专用绝缘) | 氟化液(专用绝缘) | | 主要厂商 | 英维克、Vertiv、CoolIT、Boyd | 3M、LiquidStack、高澜股份 | 3M、LiquidStack | 2.3 主流GPU平台散热需求演变 | GPU平台 | 单GPU功耗(W) | 整机功耗(kW) | 柜级功耗(kW) | 推荐散热方案 | 液冷渗透率 | | NVIDIA A100(2020) | 400W | 3.2kW(8GPU) | 20-25kW | 传统风冷可行 | <5% | | NVIDIA H100(2022) | 700W | 5.6kW(8GPU) | 30-40kW | 风冷边界/液冷选项 | ~15% | | NVIDIA H200(2024) | 700W | 5.6kW(8GPU) | 35-45kW | 液冷强烈推荐 | ~30% | | NVIDIA GB200(2025) | 1200W                     | NVL72: 120kW+ | 120kW+ | 强制液冷 | >70% | | NVIDIA GB300(2026) | 1400W+ | NVL144: 250kW+ | 250kW+ | 强制液冷(可能浸没) | ~100% | | NVIDIA Rubin(2027E) | >1500W | TBD | TBD(更高) | 强制液冷/浸没式 | ~100% | 三、液冷系统核心部件体系 液冷系统由CDU、冷板、管路分配单元、快接头、工质等核心部件组成,各部件均有其技术壁垒和核心厂商。 3.1 冷板式液冷系统核心部件 | 部件 | 功能 | 技术要求 | 全球主要供应商 | 国内主要厂商 | 成本占比 | | CDU(冷量分配单元) | 控制冷却液的温度、压力、流量 | ±0.5°C精度,冗余设计 | Vertiv、CoolIT、Boyd | 英维克、高澜股份、同飞股份 | 25-30% | | 冷板(Cold Plate) | 直接接触GPU/C PU表面带走热量 | 微通道设计,热阻<0.05°C/W | CoolIT、Boyd、AAVID | 英维克、飞荣达、高澜股份 | 20-25% | | Manifold(管路分配器) | 分配冷却液到各冷板 | 耐压、均匀分配、快速连接 | CPC、Staubli | 英维克、申菱环境 | 10-15% | | 快接头(Quick Connect) | 实现管路无滴漏快速连接 | 零泄漏设计,耐插拔>5000次 | Staubli、CPC、Parker | 英维克、旭升股份 | 5-8% | | 工质/冷却液 | 传导热量从服务器到CDU | 低冰点、高比热、低导电性 | 3M(Novec)、Solvay | 巨化股份、东岳集团 | 3-5% | 3.2 浸没式液冷核心部件 | 部件 | 功能 | 技术要求 | 全球主要供应商 | 国内主要厂商 | | 浸没槽(Tank) | 容纳GPU服务器和浸没液体 | 密封、耐腐蚀、结构强度 | LiquidStack、GRC、3M | 高澜股份、依米康 | | CDU(冷量分配) | 控制浸没液体温度和流动 | 大流量、高效换热、防泄漏监控 | 英维克、Vertiv、CoolIT | 英维克、高澜股份 | | 浸没工质 | 绝缘散热介质 | 高绝缘、低沮度、不燃 | 3M(Novec)、Solvay(Fluorinert) | 巨化股份、东岳集团(研发中) | 四、产业链全景图 液冷产业链从上游核心部件到中游系统集成再到下游数据中心部署,涵盖8个关键环节。 | 产业层次 | 子环节 | 主要产品/服务 | 代表企业(国内) | 代表企业(海外) | 投资评价 | | 上游 | 液冷工质 | 氟化液、乙二醇溶液、去离子水 | 巨化股份、东岳集团 | 3M、Solvay、Chemours | 氟化液供应高度依赖3M,有替代空间 | | 上游 | 泵、阀、管路、传感器 | 循环泵、电动阀、流量计、温度传感器 | 汇川技术、汉钟精机 | Grundfos、Belimo、Siemens | 部分关键部件仍依赖进口 | | 上游 | 快接头/连接器 | 液冷快接头、流体连接器 | 旭升股份、英维克 | Staubli、CPC、Parker | 零泄漏设计是技术核心 | | 中游 | 核心部件制造 | CDU、冷板、Manifold、换热器 | 英维克、高澜股份、同飞股份 | Vertiv、CoolIT、Boyd、AAVID | 核心投资主线,国产正在快速追赶 | | 中游 | 液冷系统集成 | 整体液冷解决方案设计与集成 | 英维克、依米康、佳力图 | Vertiv、Schneider、CoolIT | 系统集成能力是核心壁垒 | | 中游 | 数据中心温控设备 | 精密空调、气流组织、温控系统 | 英维克、佳力图、依米康 | Vertiv、Schneider、Stulz | 传统温控与液冷融合 | | 下游 | AI数据中心/云厂商 | 超大型AI集群部署与运营 | 阿里云、华为云、百度智脑 | AWS、Azure、GCP、Meta | 核心拉动力,液冷采购才刚开始 | | 下游 | 5G/边缘计算/超算 | 基站、边缘数据中心、超级计算机 | 中国移动、中科院 | NTT、美国能源部 | 稳定高端需求,体量较小 | 五、全球市场规模 5.1 全球数据中心液冷市场预测 | 年份 | 全球市场(亿元) | 冷板式占比 | 浸没式占比 | 同比增速 | 市场记忆 | | 2022年 | 60 | 95% | 5% | - | 风冷主导,液冷仅在超算少量应用 | | 2023年 | 100 | 93% | 7% | +67% | ChatGPT拉动AI训练集群建设 | | 2024年(E) | 150 | 90% | 10% | +50% | H100集群大规模部署拉动液冷 | | 2025年(E) | 220 | 85% | 15% | +47% | GB200 NVL72量产交付,液冷强制 | | 2026年(E) | 320 | 80% | 20% | +45% | GB300、1.6T光模块拉动 | | 2028年(E) | 480 | 70% | 30% | +22% | 浸没式加速商用化 | | 2030年(E) | 600+ | 60% | 40% | CAGR>20% | 浸没式成为重要增量 | 5.2 中国数据中心液冷市场 | 年份 | 中国市场(亿元) | 全球占比 | 主要驱动因素 | | 2022年 | 15 | 25% | 东数西算启动,信创液冷先行 | | 2023年 | 30 | 30% | AI训练集群建设加速 | | 2024年(E) | 50 | 33% | 国产芯片量产拉动配套液冷 | | 2025年(E) | 80 | 36% | 英维克等国产厂商订单爆发 | | 2026年(E) | 120 | 38% | 国产GB300类似方案部署 | | 2030年(E) | 240 | 40% | CAGR~25%,全球增速最快 | 5.3 液冷部件市场细分结构 | 细分市场 | 2025年占比 | 2030年占比(E) | 增长驱动力 | | CDU冷量分配单元 | 25% | 22% | 单体价值高,技术壁垒深 | | 冷板(Cold Plate) | 22% | 20% | 用量大但竞争激烈 | | 管路与分配系统(Manifold) | 15% | 16% | 随GPU柜数量线性增长 | | 快接头与流体连接器 | 8% | 10% | 强制液冷提升配套比例 | | 液冷工质 | 5% | 8% | 浸没式采用拉动氟化液需求 | | 系统集成与服务 | 25% | 24% | 解决方案能力决定竞争地位 | 六、全球主要厂商 6.1 海外主要厂商 | 厂商 | 所在地 | 主要产品 | 技术定位 | 核心竞争优势 | | Vertiv(维谟) | 美国 | CDU、精密空调、数据中心整体温控 | 全球数据中心温控第一 | 全产品线+全球服务网络 | | CoolIT Systems | 加拿大 | 冷板、CDU、液冷解决方案 | 冷板式液冷全球领先 | 直接液冷技术专利壁垒 | | Boyd Corporation | 美国 | 冷板、换热器、液冷组件 | 冷板设计与制造龙头 | 微通道加工技术积累深厚 | | 3M | 美国 | 氟化液(Novec)、浸没式解决方案 | 浸没工质全球垄断>70% | 化学配方专利+规模优势 | | Schneider Electric | 法国 | 数据中心整体温控、配电、监控 | 数据中心基础设施全球巨头 | 产品组合+品牌+服务网络 | 6.2 国内主要厂商 | 厂商 | 股票代码 | 主要产品 | 技术定位 | AI液冷业务进展 | 投资评级 | | 英维克 | 002837 | CDU、冷板、液冷系统集成、数据中心温控 | 国内液冷绝对龙头,全球前三 | GB200等超大型项目已获订单,液冷业务增速>50% | ★★★★★ | | 高澜股份 | 300499 | CDU、冷板、浸没式液冷系统 | 国内液冷核心部件领先者 | 具备冷板式和浸没式双技术路线 | ★★★★★ | | 同飞股份 | 300990 | 液体恒温设备、精密温控、液冷CDU | 工业级液体恒温领先者 | 正在切入数据中心液冷赛道,已建设液冷项目 | ★★★★☆ | | 依米康 | 300249 | 数据中心温控设备、液冷系统集成 | 数据中心全生命周期温控服务商 | 液冷系统集成项目持续获单 | ★★★★☆ | | 佳力图 | 603912 | 精密空调、机房环境一体化产品 | 数据中心精密空调领先者 | 正在向液冷方向拓展,传统温控受益AI建设 | ★★★☆☆ | | 申菱环境 | 301018 | 数据中心温控设备、液冷系统解决方案 | 数据中心环境控制新势力 | 液冷解决方案已在多个项目部署 | ★★★☆☆ | 七、国产替代进展 7.1 液冷各环节国产化率 | 产业环节 | 国产化率(2024E) | 国产化率(2027E) | 主要短板 | 核心国产厂商 | | 液冷系统集成 | ~35% | ~50% | 大型项目经验积累 | 英维克、依米康、佳力图 | | CDU冷量分配单元 | ~30% | ~45% | 控制精度、冗余设计 | 英维克、高澜股份、同飞股份 | | 冷板(Cold Plate) | ~40% | ~55% | 微通道加工、热阻优化 | 英维克、飞荣达、高澜股份 | | 快接头 | ~25% | ~40% | 零泄漏设计、耐用次数 | 旭升股份、英维克 | | 浸没工质(氟化液) | <5% | ~15% | 3M垄断>70%,化学配方专利 | 巨化股份、东岳集团(研发中) | | 循环泵/高端阀门 | ~30% | ~45% | 长期可靠性、耐腐蚀 | 汇川技术、汉钟精机 | 7.2 中国厂商与国际巨头对比 | 对比维度 | Vertiv(美) | 英维克 | 高澜股份 | 差距分析 | | 产品线广度 | 温控全产品线全球领先 | CDU+冷板+液冷系统全覆盖 | CDU+冷板+浸没式系统 | 产品线已基本追平Vertiv | | 年营收(亿元) | >500 | ~60 | ~10 | 规模差距大,但国产增速远超 | | AI液冷市场份额 | 全球第一 | 国内第一/全球前三 | 国内前三,浸没领先 | 英维克在国内AI液冷占捠>40% | | 浸没式能力 | Ü用合作伙伴方案 | Ü小规模部署 | Ü国内浸没领先 | 高澜在浸没领域最具前瞻性 | | 客户结构 | 全球云厂商+企业客户 | 国内云厂商+NVIDIA×国内46 | 国内数据中心+超算 | 英维克客户质量国内最优 | 八、核心驱动因素 驱动因素一:GPU功耗爆发式增长强制推动液冷采用 NVIDIA GB200单芯片功耗达1200W,NVL72柜级功耗超120kW,传统风冷已无法满足。每一代GPU功耗提升50-100%,而风冷制冷能力基本到顶,液冷是唯一解。NVIDIA已明确GB200及后续产品强制液冷,直接锁定未来5年的液冷采购增量。 驱动因素二:超大型数据中心建设拉动集中式液冷解决方案 单个超大型AI数据中心布局数万张GPU,总功耗达数百MW。集中式液冷方案通过外部冷却塔集中散热,可显著降低PUE和运营成本。微软、Meta、英伟达等已全面采用液冷方案。 驱动因素三:双碳目标与PUE要求提升 国家双碳政策要求数据中心PUE降至1.3以下,部分地区要求<1.2。液冷可将PUE从1.4-1.5降至1.1以下,是达标的核心手段。同时液冷可提升单柜功率密度,节省土地和空间成本。 驱动因素四:浸没式液冷商用化将开启新增量 随着3M Novec专利临近到期和国产工质替代加速,浸没式液冷的成本正在下降。预计2027-2030年浸没式将从小规模商用迈向大规模部署,成为液冷市场的第二增长极。 驱动因素五:边缘计算与5G基站等多元化下游 边缘数据中心、5G基站、超算中心、智能网联汽车等场景也需要高效散热解决方案。多元化下游为液冷产业提供稳定的增长基本盘,降低单一AI行业周期风险。 九、投资机会与标的 9.1 投资时间维度分析 | 投资期限 | 首选标的 | 驱动逻辑 | 预期回报 | 风险提示 | | 居考当前(2025) | 英维克、高澜股份 | GB200液冷订单爆发+业绩高增速 | 中局期高弹性 | 订单集中度高 | | 2025-2027年 | 英维克、同飞股份、依米康 | GB300/NVL144拉动液冷升级 | 中高位期弹性 | 技术路线验证+产能爬坡 | | 长期(2027+) | 英维克、高澜股份 | 浸没式量产+国产全面替代 | 高截希 | 3M工质供应链+技术路线转变 | 9.2 A股标的详解 英维克(002837) ★★★★★ 首选标的 英维克是国内液冷绝对龙头,也是全球液冷市场前三。公司在CDU、冷板、快接头、系统集成等核心环节全覆盖,GB200等超大型项目已获订单。液冷业务增速>50%,是AI液冷赛道最确定性最高的标的。 高澜股份(300499) ★★★★★ 首选标的 高澜股份是国内少数同时具备冷板式和浸没式液冷技术能力的厂商,在CDU和冷板等核心部件上具有较强实力。公司在浸没式液冷领域布局领先,未来成长空间大。 同飞股份(300990) ★★★★☆ 积极成长标的 同飞股份是国内工业级液体恒温设备龙头,具备精密温控技术积累。公司正在积极切入数据中心液冷赛道,已投资3亿元建设液冷温控项目。技术底子厚、新赛道弹性大。 依米康(300249) ★★★★☆ 积极成长标的 依米康是数据中心全生命周期温控服务商,业务涵盖精密空调、冷热通道、液冷系统集成。公司在数据中心温控领域具有较强品牌和客户基础,液冷业务正在快速增长。 佳力图(603912) ★★★☆☆ 成长标的 佳力图主要做数据中心精密空调和机房环境一体化产品,传统温控业务直接受益于AI数据中心建设。公司正在向液冷方向拓展,但转型进度待观察。 申菱环境(301018) ★★★☆☆ 成长标的 申菱环境主要做数据中心环境控制设备,液冷解决方案已在多个项目部署。公司规模尚小,但随着AI数据中心液冷采购增长,成长空间可期。 十、风险提示与产业展望 10.1 主要风险提示 ·《技术标准未统一风险》:冷板式与浸没式的技术路线之争尚未定论,不同云厂商采用不同方案,导致产业链标准化困难。若某一路线被软件放弃,相关供应商可能受到冲击。 ·《浸没工质供应链风险》:3M Novec氟化液在浸没式市场占比>70%,且部分产品面临环保限制。国产工质替代进度直接影响浸没式液冷商用化节奏。 ·《液冷泄漏与可靠性风险》:液冷系统一旦出现管路破裂或快接头泄漏,可能造成GPU整机损毁。这对系统可靠性和工程质量提出极高要求。 ·《产能迅速扩张导致竞争加剧风险》:国内液冷产能在快速扩张,若需求增速放缓或供应过剩,将导致价格战和利润率下降。 ·《新型散热技术替代风险》:半导体制冷、热电致冷等新型散热技术可能在长期部分替代传统液冷方案。但短期内液冷仍是最确定的技术路线。 10.2 中长期产业展望 2026-2030年,数据中心液冷行业将呈现以下主要趋势: 1. 冷板式液冷将在未来3年保持主导地位,占比>60%,但浸没式从2027年起进入快速商用化期 2. NVIDIA的各代GPU平台将持续锁定液冷采购增量,2030年新建AI数据中心液冷渗透率将接近100% 3. 国产替代将从“冷板/CDU”向“浸没工质/循环泵/高端阀门”等更高壁垒环节突破 4. 集中式液冷方案将成为超大型数据中心的标配,拉动CDU和系统集成商的价值量提升 5. 3M Novec专利到期后国产工质替代将降低浸没式成本30-50%,加速商用化 6. 投资建议:重点关注液冷系统龙头(英维克)、双技术路线厂商(高澜股份)、以及新赛道切入者(同飞股份、300990) 活动推荐1: 一、拟邀议题 | 序号 | | | 人形机器人轴向磁通关节电机与球形关节电机的研究与应用 | | | 具身智能机器人关节电机开发重点和难点剖析 | | | 关节电机的新技术探讨 | | | 机器人关节模组开发经验分享 | | | 微型线性执行方案的含金量 | | | 轴向磁通电机在机器人关节电机的应用进展和趋势 | | | 关于机器人关节系统研究的分享 | | | 探索人形机器人关节技术发展路径 | | | 谐波减速器等关节模组的设计与应用 | | | 通用机器人关键技术在汽车产业的应用和实践 | | | 具身智能机器人本体核心零部件的创制与应用 | | | 关节伺服驱动器在具身智能产业链中的位置及其发展方向 | | | 壮年机器人关节永磁电驱滑模观测技术应用 | | | 环面包络蜗轮蜗杆减速器赋能机人关节 | | | 圆桌会议:人形机器人关节电机的开发重点以及难点 | 议题征集中,创新演讲及赞助请联系张晚晚 13671990811(同微信) 二、拟邀企业类型: 三、报名方式 欢迎加入新能源汽车产业交流群 关注公众号后台回复关键词“社群” 即可获取入群方式