# Vertiv Q1 2026 revenue hits $2.65B as AI cooling M&A tops $14.25B; Envicool 2025 sales reach RMB 6.068B

- Source: News · Envicool (T2)
- Published: 2026-07-24
- Score: 64.4
- Tags: Datacenter, M&A / JV, Market data
- Companies: Vertiv, Envicool (002837.SZ), NVIDIA
- Original: https://wallstreetcn.com/articles/3777873

## Intelligence brief

### What happened A Chinese industry report published by Pencil News on 24 July 2026 describes how AI server thermal management has become a large, fast-growing business. The report cites US data-centre power and thermal management company Vertiv, which recorded Q1 2026 revenue of USD 2.65 billion, up 30% year on year, selling power, cooling and rack infrastructure rather than GPUs. Modine Manufacturing, historically an automotive radiator maker, reportedly won a one-off USD 180 million cooling system order from an AI infrastructure developer in 2025, and its AI data-centre cooling revenue surged 158% in Q1 2026. Chinese data-centre thermal equipment maker Envicool posted record 2025 revenue of RMB 6.068 billion; in March 2026 a Google procurement team reportedly travelled to China to discuss AI data-centre liquid cooling equipment purchases with the company. The report also notes two large M&A deals: Ecolab's USD 4.75 billion acquisition of Canadian liquid cooling firm CoolIT Systems in July 2026, and Eaton's USD 9.5 billion purchase of thermal management company Boyd Thermal several months earlier, totalling USD 14.25 billion. It further describes Nvidia's progression from H100 (700W per card) to GB200 (1,200W) to Rubin (2,300W), with air cooling limited to roughly 800W per chip and Nvidia declaring liquid cooling mandatory for the Rubin generation. The report quotes Yang Guang, general manager of Jizhi Lengyuan, on PUE improvements, supply chain dynamics and four ways to make money in liquid cooling, and Zhang Yizhe of Yonggui Fund on three layers of thermal management and domestic substitution opportunities in server fan modules. ### Key figures - Vertiv Q1 2026 revenue: USD 2.65 billion, +30% year on year. - Modine Manufacturing: USD 180 million cooling system order from an AI infrastructure developer in 2025; AI data-centre cooling revenue +158% in Q1 2026. - Envicool 2025 revenue: RMB 6.068 billion (record). - Ecolab acquisition of CoolIT Systems: USD 4.75 billion (July 2026). - Eaton acquisition of Boyd Thermal: USD 9.5 billion. Combined deal value: USD 14.25 billion. - Nvidia per-card power: H100 700W, GB200 1,200W, Rubin 2,300W; air cooling limit approximately 800W per chip. - Global data-centre cooling market: USD 26.3 billion (2025) to USD 128.3 billion (2033), roughly a fivefold increase in eight years. - PUE: traditional air cooling 1.4-1.8; cold plate liquid cooling 1.1-1.2; immersion liquid cooling 1.04-1.09. Each 0.1 PUE reduction saves over 10 million kWh per year for a 10+ MW IT-load, 10,000-card data centre. - China liquid cooling server penetration: 12% in 2025, 28% in H1 2026; all 40-plus newly built 10,000-card AI computing centres in China use liquid cooling. - CDU pricing: RMB 200,000-300,000 per 25-30 kW unit. - China liquid cooling market: approximately RMB 30 billion in 2026, exceeding RMB 100 billion by 2030, CAGR above 45% from 2025 to 2030. - AVC (Asia Vital Components) annual revenue: NTD 139.6 billion (about RMB 32 billion). Nidec: JPY 2.61 trillion (about RMB 125 billion). Minebea Mitsumi: JPY 1.66 trillion (about RMB 80 billion); its fan motor business sales for the fiscal year ending March 2026 were about JPY 90 billion (about RMB 4.2 billion). - A Guangdong cooling fan company has reportedly reached close to RMB 1 billion in revenue. ### Why it matters to ebm-papst The report frames thermal management as a structural growth market driven by rising chip power density, with liquid cooling becoming mandatory at the Rubin generation and air cooling still dominant at chip, board and edge layers. For ebm-papst, this is a demand signal for high-performance fan and blower modules in servers, racks and edge AI devices, and for components that remain relevant even as liquid cooling spreads. The report explicitly states that the global server air-cooling module market has long been dominated by Japanese and Taiwanese suppliers such as AVC, Nidec and Minebea Mitsumi, and that mainland Chinese suppliers remain orders of magnitude smaller, while a Guangdong fan maker is approaching RMB 1 billion in revenue with quarterly doubling in new segments including robotics, automotive and AIDC business with Alibaba Cloud and Oulutong. Assessment (inference): This suggests ebm-papst faces intensifying competition from both established Asian incumbents and fast-scaling Chinese fan makers in server and AIDC cooling, while also facing an opportunity to supply premium, high-reliability fan and blower solutions for hybrid air-liquid architectures, edge AI and industrial cooling where European quality and lifetime requirements matter. Assessment (inference): The consolidation of liquid cooling specialists by Ecolab and Eaton may shift system-level purchasing power toward larger players, potentially changing how fan and blower suppliers are qualified into AI data-centre supply chains. Assessment (inference): The reported Google-Envicool talks and the 28% China liquid cooling penetration in H1 2026 indicate that Chinese suppliers are moving up the value chain, which could pressure ebm-papst's positioning in China-based AI infrastructure projects.

## Full text (English translation)

Token has made this RMB 870 billion business hot.

A business hidden in a corner has become hot.

This is cooling AI servers.

Vertiv, the US data-centre power and thermal control giant, reached USD 2.65 billion in Q1 2026 revenue, up 30% year on year. What it sells is not GPUs, but power, cooling and rack infrastructure for GPUs.

Modine Manufacturing, which makes automotive radiators, won a one-off USD 180 million cooling system order from an AI infrastructure developer in 2025, and its AI data-centre cooling business revenue surged 158% in Q1 2026.

Envicool, which makes data-centre thermal control equipment, posted record 2025 revenue of RMB 6.068 billion; in March 2026, Google's procurement team travelled to China specifically to discuss AI data-centre liquid cooling equipment purchases with it.

A single eight-card B200 server costs several million RMB. But if cooling is not solved, the chips downclock after two minutes of running and computing power drops by 20%. No matter how powerful the chip, if it cannot dissipate heat, it may just be a hot piece of silicon.

The global data-centre cooling market is expected to grow from USD 26.3 billion (about RMB 178 billion) in 2025 to USD 128.3 billion (about RMB 869 billion) in 2033, nearly fivefold in eight years.

"Cooling solves a kind of invisible 'bottleneck' problem," Yang Guang, general manager of Jizhi Lengyuan, told Pencil News.

What is cooled is the chip; what is increased is Token

In July this year, global water treatment giant Ecolab spent USD 4.75 billion to buy Canadian liquid cooling company CoolIT Systems.

A few months earlier, electrical equipment giant Eaton also spent USD 9.5 billion to acquire thermal management company Boyd Thermal.

The two deals total USD 14.25 billion.

What buyers are scrambling for is not large models, nor GPUs, but a group of companies producing cold plates, fans, pumps, heat exchangers and thermal interface materials.

Money suddenly poured in because AI servers are getting hotter and hotter.

AI computing has an unavoidable physical law: a large part of the electricity consumed by chips ultimately becomes heat.

The more chips, and the longer they run, the hotter the machine room becomes.

From Nvidia H100 to GB200 to Rubin, per-card power jumped from 700W to 1,200W, then to 2,300W. The limit of air cooling is about 800W per chip; beyond that threshold, no matter how many fans there are, they cannot suppress it. At the Rubin generation, Nvidia directly announced that the entire system must have liquid cooling as standard — it is not a choice, it is a physical problem.

If cooling capacity is insufficient, even the most expensive GPU cannot continuously release performance.

Only when temperature control is more stable can chips maintain higher performance in continuous inference tasks.

High temperatures also accelerate the aging of electronic components, packaging materials and connectors. For a server worth several million RMB or more, reducing one failure and extending effective service life both mean more Token output.

This year, as large-model inference demand increased, ensuring smooth Token output has become the first task for major manufacturers.

"Last year the industry discussed: is liquid cooling really a trend? This year, no one discusses this question anymore." Yang Guang described a change: now everyone talks about how to design cold plates, how to choose coolant, how to match thermal interface materials, and how to improve reliability.

Yang Guang observed that liquid cooling orders in the North American market are growing very fast, and some mainland China and Taiwan suppliers already cannot keep up with orders.

Information shows that Yinlun, which makes microchannel cold plates, is expanding overseas chip packaging and server customers with products such as liquid cooling plates and heat exchangers; Envicool is a core supplier of Google TPU liquid cooling CDUs. The overseas business of leading domestic enterprises is becoming a second growth curve.

Back in China, the situation is different: liquid cooling companies serving the domestic market are generally not full, and some small manufacturers cannot even get orders.

The reason is not complicated.

North American cloud computing companies deployed Nvidia GB200, GB300 and other liquid cooling servers earlier, so orders can be immediately passed to cold plate, CDU, connector and heat exchanger companies. The Chinese market still has a large number of air-cooled servers, and the domestic AI chip and software ecosystem is still in a stage of continuous adaptation, verification and scaling.

Therefore, a contrast has appeared in China's liquid cooling industry: the capital market looks very hot, but many companies in the supply chain are still waiting for truly large-scale orders.

"Of course China has some high-end GPUs, but on the one hand production is limited, and on the other hand, at this stage some domestic chips' power and heat flux density can still be solved with traditional air cooling."

Yang Guang repeatedly emphasized a fact that is easily overlooked: "Whether there is liquid cooling demand first depends on whether there are liquid cooling servers." If a server leaves the factory air-cooled, then no matter how high the chip power is, at this stage it can only use air cooling.

But conversely, this also means that the explosion of the domestic market is only a matter of time. The next generation of domestic chips will certainly continue to increase power consumption, and at that critical point, liquid cooling demand will be released in a concentrated way.

Institutional estimates put China's liquid cooling market at nearly RMB 30 billion in 2026, expected to exceed RMB 100 billion by 2030, with a compound growth rate above 45% from 2025 to 2030.

Four ways to make money in liquid cooling

Yang Guang's judgment is clear: liquid cooling will become the basic configuration of AIDC (artificial intelligence data centres).

He did the math:

Traditional air-cooled data-centre PUE (power usage effectiveness) is usually between 1.4 and 1.8; cold plate liquid cooling can reduce it to 1.1 to 1.2, and immersion liquid cooling can even reach 1.04 to 1.09. For every 0.1 reduction in PUE, a 10,000-card data centre with over ten megawatts of IT power can save more than ten million kWh per year.

A market report by CCID Consulting shows: in 2025, the overall penetration rate of domestic liquid cooling servers was only 12%, and in the first half of 2026 it directly soared to 28%. All of the more than 40 newly built 10,000-card AI intelligent computing centres nationwide use liquid cooling solutions, and not one chose traditional air cooling.

Many people think the liquid cooling industry makes money by selling equipment. In fact, the ways of making money in this industry chain are much more complex than imagined.

There are mainly three:

First, selling equipment. The most direct model, represented by CDU (coolant distribution unit). A 25-30 kW CDU sells for RMB 200,000 to 300,000 on the market. Vertiv is one representative of this model; it was once the designated CDU supplier in Nvidia's early liquid cooling supply chain.

But the ceiling for selling equipment is also the most competitive. Domestic price competition is already very fierce, and many companies' revenue grows but profit does not rise in sync. Yang Guang said that CDU and cold plates are essentially close to manufacturing, "with volume but no money."

Second, being a tier-two supplier. There are many companies in the Jiangsu-Zhejiang area that originally made radiators and pump units. Without a big brand, it is hard for them to directly enter Nvidia's or North American customers' supply chains. So they act as tier-two suppliers to Taiwanese and North American server, rack and liquid cooling companies, producing under OEM labels.

These companies' business is actually very good. Because some Taiwanese companies are deeply tied to Nvidia, domestic companies indirectly enter the North American market through them, and orders are not a worry.

Third, operations and maintenance services. This is a direction Yang Guang believes may be a good business in the future. Traditional data centres fear water entering the machine room most, but in the liquid cooling era there is a whole liquid circulation system in the data centre. Coolant must be tested regularly; corrosion, impurities and microorganisms may appear inside equipment; and leaks, pipelines and equipment status must be monitored.

Once this system is put into operation, maintenance demand exists for the long term. Initial investment is relatively low, the main cost is personnel and service system, and it is possible to form stable service revenue.

Yang Guang believes that the fourth way, which Jizhi Lengyuan is exploring, is where heat dissipation will really make money in the future: not waiting until chips are made and then adding cooling, but defining the entire solution together with chip makers and packaging houses at the beginning of chip design.

As domestic computing chips' power and heat flux density continue to rise, heat dissipation will become increasingly difficult to solve with a single component. What chip makers really need is not to separately purchase cold plates, CDUs, pipes and pumps and then assemble them themselves, but a complete solution with a completed technical route, material selection and system matching.

This requires suppliers to understand heat transfer, fluids and materials, and also to combine chip power distribution, local hot spots and packaging structures for joint design. This is exactly the position Jizhi Lengyuan hopes to occupy: not just selling "ingredients," but starting from the chip source to serve domestic chip makers a "finished dish" that can be directly implemented.

Huge opportunity for domestic substitution

But if your understanding still stays at "liquid cooling = heat dissipation," you may only be seeing the tip of the iceberg.

Zhang Yizhe, founding partner of Yonggui Fund, has a judgment: heat dissipation is layered.

He divided heat dissipation into three levels:

First layer, chip and board level. The heat of the chip itself must first be transferred out through thermal conductive materials, heat pipes and vapor chambers. At this layer, air cooling and active cooling are still the main force. Just like human skin dissipates heat first, and only when it really cannot bear it does it need air conditioning.

Second layer, server and rack level. Multiple servers stacked together concentrate heat, requiring a liquid cooling system to carry the heat away. Cold plate liquid cooling and immersion liquid cooling mainly play a role at this layer.

Third layer, data-centre level. Heat dissipation scheduling for the entire campus, including cooling towers, heat exchangers and waste heat recovery, belongs to a larger system engineering.

"Liquid cooling and air cooling correspond to heat dissipation needs at different levels and different positions," Zhang Yizhe emphasized. It cannot be simply understood that liquid cooling will completely replace air cooling.

This means the heat dissipation industry is far more than just the liquid cooling track. Even in air cooling, a field many consider "traditional" and "backward," there are huge domestic substitution opportunities.

Surprisingly: the global server air cooling module market has long been dominated by Japanese and Taiwanese companies.

Representative Taiwanese companies such as AVC (Asia Vital Components) have annual revenue of NTD 139.6 billion (about RMB 32 billion), while Japanese representatives Nidec and Minebea Mitsumi have annual revenue as high as JPY 2.61 trillion (about RMB 125 billion) and JPY 1.66 trillion (about RMB 80 billion). Compared with these giants with revenues in the tens of billions, mainland Chinese peers still have a significant gap of orders of magnitude.

"People used to think (cooling) fans are very simple, but truly doing well in performance, noise, life, reliability and cost is not easy," Zhang Yizhe said. Cooling fans have technical thresholds — structural design, material selection, dynamic balance control and life testing all require accumulation.

The logic of domestic substitution is very clear here:

First, supply chain security. Under current international relations, long-term procurement of cooling components from Japan or Taiwan, if the supply chain changes, although fans may not be the most serious "bottleneck" link, can still make downstream companies very uncomfortable.

Second, profit space. The heat dissipation industry has long been ignored, and gross margins are not low. Reaching the level of Taiwanese peers would mean considerable profit space.

According to Pencil News, a Guangdong cooling fan company has rapidly grown revenue to close to RMB 1 billion — possibly becoming the first fan company in mainland China to reach RMB 1 billion in revenue.

More important is this company's growth curve: after entering robot cooling, car-machine cooling, robot dog cooling, and AIDC-related business with Alibaba Cloud and Oulutong, revenue in new areas has basically doubled every quarter.

There is also a more upstream route heating up — heat dissipation material upgrades, from aluminum to copper, from copper to silver, and then to diamond. It is understood that some artificial diamond companies in Henan have suddenly attracted attention because of AI cooling demand. Diamond's thermal conductivity far exceeds that of metals, and it is highly expected in the field of active chip cooling.

In addition, Zhang Yizhe mentioned that the future explosion of inference-side demand will bring more cooling opportunities. "When AI truly enters the edge, AI chips or compute-in-memory chips need to be deployed locally. At that time, new cooling demand will arise at the chip layer, module layer and board layer, and the edge cooling market will be very large."

The story of the heat dissipation industry is essentially a story of a "supporting role's counterattack."

In the past, this industry was long ignored — everyone focused on chips, algorithms and applications, and no one cared about "how to cool chips," this dirty and tiring work. It was not until the exponential growth of AI computing power pushed the cooling problem to the forefront.

At each stage, different AI companies emerge. The only certainty is — as long as AI keeps moving forward, the heat dissipation industry will not cool down.

The sales scale of Minebea Mitsumi's fan motor business for the fiscal year ending March 2026 is about JPY 90 billion (about RMB 4.2 billion).

Source of this article: Pencil News

## Full text (original)

一门藏在角落里的生意，火了。
这就是给AI服务器散热。
美国数据中心电力和温控巨头维谛技术，2026年一季度营收达到26.5亿美元，同比增长30%，它卖的不是GPU，而是为GPU提供电力、制冷和机柜基础设施。
做汽车散热器的摩丁制造，2025年一次性拿到一家AI基础设施开发商价值1.8亿美元的冷却系统订单，2026年一季度AI数据中心冷却业务营收暴涨158%。
做数据中心温控设备的英维克，2025年营收创纪录地达到60.68亿元；2026年3月，谷歌采购团队又专程赴华，与其洽谈AI数据中心液冷设备采购。
一台八卡B200服务器，价格数百万元。但如果散热没搞定，芯片跑两分钟就降频，算力打八折。再牛的芯片，散不了热，可能就是一块烫手的硅。
全球数据中心散热市场预计将从2025年的263亿美元（约合人民币1780亿元）增至2033年的1283亿美元（约合人民币8690亿元），八年接近翻五倍。
“散热解决的是一种隐形的‘卡脖子’问题。”极智冷源总经理杨光告诉铅笔道。
冷却的是芯片，增加的是Token
今年7月，全球水处理巨头艺康集团斥资47.5亿美元，买下加拿大液冷公司CoolIT Systems。
几个月前，电气设备巨头伊顿也花费95亿美元，收购热管理公司Boyd Thermal。
两笔交易，合计142.5亿美元。
买家争抢的不是大模型，也不是GPU，而是一批生产冷板、风扇、水泵、换热器和导热材料的公司。
钱突然涌进来，是因为AI服务器越来越热。
AI算力有一个无法绕开的物理规律：芯片消耗的电力，最终很大一部分会变成热量。
芯片数量越多，运行时间越长，机房就越热。
从英伟达H100到GB200再到Rubin，单卡功耗从700瓦跳到1200瓦，再冲到2300瓦。风冷的极限大约在单芯片800瓦，超过这个阈值，再多风扇也压不住。到了Rubin这一代，英伟达直接宣布整套系统必须标配液冷——不是选择问题，是物理问题。
如果散热能力不足，最贵的GPU也无法持续释放性能。
温度控制得更稳定，芯片才能在持续推理任务中维持更高性能。
高温还会加速电子元件、封装材料和连接部件老化。对于一套价值数百万元甚至更高的服务器，减少一次故障、延长一段有效使用期，都意味着更多Token产出。
今年大模型推理需求增加，保证Token顺利产出，成为各大厂商第一任务。
“去年行业讨论的是：液冷究竟是不是趋势？到了今年，已经没人讨论这个问题了。”杨光描述了一个的变化：大家现在聊的是冷板怎么设计、冷却液怎么选、热界面材料怎么匹配、怎么提高可靠性。
杨光观察到，北美市场的液冷订单增长很快，一些中国大陆和中国台湾供应商已经出现订单做不过来的情况。
资料显示，做微通道冷板的银轮股份，正以液冷板、换热器等产品拓展海外芯片封装和服务器客户；英维克是谷歌TPU液冷CDU的核心供应商。国内头部企业的出海业务，正在成为第二增长曲线。
回到国内，情况则不同，做国内市场的液冷企业普遍吃不饱，有些小厂家甚至拿不到订单。
背后的原因并不复杂。
北美云计算公司更早部署英伟达GB200、GB300等液冷服务器，订单可以立刻传递到冷板、CDU、连接器和换热器企业。中国市场仍然存在大量风冷服务器，国产AI芯片和软件生态也处于持续适配、验证和放量阶段。
因此，中国液冷行业出现了一个反差：资本市场看上去非常火热，供应链中的很多公司却还在等待真正的大规模订单。
“国内当然有一些高端GPU，但一方面产量受限，另一方面现阶段部分国产芯片的功率和热流密度，还能用传统风冷解决。”
杨光反复强调一个容易被忽略的事实：“有没有液冷需求，首先要看有没有液冷服务器。”一台服务器出厂时是风冷的，芯片功率再高，现阶段也只能用风冷。
但反过来看，这也意味着国内市场的爆发只是时间问题。国产芯片下一代产品一定会沿着功耗继续提升，到了那个临界点，液冷需求会集中释放。
机构测算，国内液冷市场2026年规模接近300亿元，预计2030年突破千亿，2025至2030年复合增速保持在45%以上。
液冷散热四种赚钱方法
杨光的判断很明确：液冷将成为AIDC（人工智能数据中心）的基础配置。
他算了一笔账：
传统风冷数据中心PUE（能源使用效率）通常在1.4到1.8之间，冷板液冷可以降到1.1到1.2，浸没液冷甚至能到1.04到1.09。PUE每降0.1，一个IT功率十几兆瓦的万卡级数据中心，一年就能省下上千万度电。
赛迪顾问一篇市场报告显示：2025年国内液冷服务器整体渗透率仅12%，2026年上半年直接飙升至28%。全国新建的40余家万卡级AI智算中心，全部采用液冷散热方案，无一家选择传统风冷。
很多人以为液冷行业就是卖设备赚钱。实际上，这个产业链上的赚钱方式，比想象中复杂得多。
主要有三种：
第一种，卖设备。 最直接的模式，代表是CDU（液冷分配单元）。一套25到30千瓦的CDU，市场售价20万到30万元。维谛技术是这种模式的代表之一，它曾是英伟达早期液冷供应链里的指定CDU供应商。
但卖设备的天花板也最卷。国内价格竞争已经非常激烈，很多企业营收增长，利润却没有同步上涨。杨光说，CDU和冷板本质上已经接近制造业，“有量不挣钱”。
第二种，做二级供应商。 江浙一带有很多企业，原来做散热器、泵组，没有大品牌，很难直接进英伟达或北美客户的供应链。于是它们给中国台湾和北美的服务器、机架、液冷企业做二级供应商，贴牌生产。
这类企业生意反而很好。因为中国台湾的一些企业和英伟达深度绑定，国内企业通过它们间接进入北美市场，订单不愁。
第三种，运维服务。 这是杨光认为未来可能是门好生意的方向。传统数据中心最怕水进机房，但液冷时代数据中心里有一整套液体循环系统。冷却液要定期检测，设备内部可能出现腐蚀、杂质、微生物，还要监测漏液、管路和设备状态。
这套系统一旦投运后，维护需求长期存在。初始投入相对低，主要成本是人员和服务体系，有可能形成稳定的服务收入。
而杨光认为，未来散热真正赚钱的是第四种，也就是极智冷源正在探索的：不是等芯片造出来后再补散热，而是在芯片设计之初，就与芯片厂、封装厂一起定义整套方案。
随着国产算力芯片功率和热流密度不断上升，散热将越来越难靠单一部件解决。芯片厂真正需要的，也不是分别采购冷板、CDU、管路和泵，再自己拼装，而是一套已经完成技术路线、材料选型和系统匹配的完整方案。
这要求供应商既懂传热、流体和材料，也能结合芯片功率分布、局部热点和封装结构进行联合设计。极智冷源希望占据的正是这一位置：不只卖“食材”，而是从芯片源头切入，为国产芯片厂端出一套可以直接落地的“成品菜”。
国产化巨大机会
但如果你的认知还停留在“液冷=散热”，那可能只看到了冰山一角。
咏归基金创始合伙人张以哲有个判断：散热是分层的。
他把散热分成了三个层级：
第一层，芯片和板卡级。 芯片本身的热量，首先要通过导热材料、热管、均热板传出来。这一层，风冷和主动散热仍然是主力。就像人体皮肤先散热，实在扛不住了才需要空调。
第二层，服务器和机柜级。 多台服务器堆在一起，热量集中，需要液冷系统把热量带走。冷板液冷、浸没液冷主要在这一层发挥作用。
第三层，数据中心级。 整个园区的散热调度，包括冷却塔、换热器、余热回收等，属于更大的系统工程。
"液冷和风冷对应的是不同层级、不同位置的散热需求。"张以哲强调，不能简单理解为液冷会把风冷完全取代。
这意味着散热行业远不止液冷一条赛道。光是风冷这个被很多人认为"传统""落后"的领域，就藏着巨大的国产化机会。
说出来让人意外：全球服务器风冷散热模组市场，长期被日本和中国台湾企业占据大头。
中国台湾代表性企业如AVC（奇鋐科技）年营收1396亿新台币（约合人民币320亿元），日本代表企业尼得科、美蓓亚三美年营收更是高达2.61万亿日元（约合人民币1250亿元）、1.66万亿日元（约合人民币800亿元）。与这些规模动辄数百亿的巨头相比，中国大陆同类企业则还有数量级的显著差距。
“以前大家觉得（散热）风扇很简单，但真正要把性能、噪声、寿命、可靠性和成本都做好，并不容易。”张以哲介绍。散热风扇是有技术门槛的——结构设计、材料选型、动平衡控制、寿命测试，每一项都需要积累。
国产化的逻辑在这里非常清晰：
第一是供应链安全。在当前国际关系下，长期从日本或中国台湾采购散热部件，一旦供应链发生变化，虽然风扇未必是最严重的"卡脖子"环节，但仍然可能让下游企业非常难受。
第二是利润空间。散热行业过去长期被忽视，毛利率并不低。能做到台湾同行的水平，利润空间相当可观。
据铅笔道了解，一家广东的散热风扇企业，收入已经迅速做到接近10亿元——可能成为中国大陆第一家达到10亿元收入规模的风扇企业。
更重要的是这家企业增长曲线：在进入机器人散热、车机散热、机器狗散热，以及阿里云、欧陆通等AIDC相关业务后，新增领域的收入基本上每个季度都在翻倍增长。
还有一条更上游的路线也在升温——散热材料升级，从铝到铜，从铜到银，再到金刚石。据了解，河南一些生产人造金刚石的公司，因为AI散热需求突然受到关注。金刚石的导热效率远超金属，在芯片主动散热领域被寄予厚望。
另外，张以哲提到将来推理端需求爆发，会带来更多散热机会。"当AI真正进入端侧，需要在本地部署AI芯片或者存算一体芯片。届时，芯片层、模组层和板卡层都会产生新的散热需求，端侧散热市场就会非常大。”
散热行业的故事，本质上是一个"配角逆袭"的故事。
过去，这个行业长期被忽视——大家都在关注芯片、算法、应用，没人在意"怎么给芯片降温"这种脏活累活。直到AI算力的指数级增长，把散热问题推到了台前。
每一个阶段，都有不同的AI公司跑出来。唯一确定的是——只要AI还在往前走，散热这个行业就不会冷。
文中美蓓亚三美风扇电机业务截至2026年3月财年的销售规模约为900亿日元（约合人民币42亿元）。
本文来源：铅笔道