# Haiwu launches five-layer full-stack liquid cooling for AI data centers, citing 500k cold plates and 50k CDU annual capacity

- Source: Hiwave News (T1)
- Published: 2026-09-02
- Score: 57.0
- Tags: Product launch, Datacenter, Cleanroom
- Companies: Hiwave
- Original: https://www.haiwu.com/news/dynamic/2128.html

## Intelligence brief

### What happened Haiwu (Haiwu Technology), a Chinese data center thermal management and infrastructure supplier, published a corporate technology announcement on 2026-09-02 outlining its "full-stack liquid cooling" system architecture for AI computing facilities. The company positions the offering as an end-to-end thermal management closed loop spanning five layers: device (chip) level, rack level, room level, cooling-source level, and O&M level. The stack combines cold plates, CDU (coolant distribution units), liquid cooling piping networks, an intelligent control platform, and high-efficiency cooling source systems. Haiwu explicitly rejects what it calls the industry misconception that "liquid cooling equals cold plates plus CDU hardware stacked together," and argues that there is no universal liquid cooling standard — the scenario determines the technical path. To that end, the company describes a scenario-based methodology covering four main deployment cases: (1) retrofit of existing air-cooled rooms, using modular CDU fast deployment, plate heat exchanger isolation, and zoned dynamic control to allow non-stop upgrades; (2) new-build AIDC campuses, where Haiwu engages at the campus master-planning stage to maximize free cooling and apply AI-based control; (3) micro-modules and containerized data centers, using highly integrated prefabricated liquid cooling designs; and (4) customers with phased compute roadmaps, offered a stepwise migration path from airflow optimization to targeted rack-level liquid cooling and finally full-room liquid cooling. Haiwu also presents itself as a full-lifecycle service provider covering consulting and design, solution planning, engineering construction, and O&M optimization, supported by what it lists as six core capabilities including a standard technology library, engineering delivery system, liquid cooling safety control logic, water quality and reliability management, and consulting/design enablement. The announcement is a corporate positioning and capability statement; no customer names, contract values, or project locations were disclosed. ### Key figures - Cleanroom capacity: 2,200 sq m ISO Class 7 ("ten-thousand class") cleanroom; 4,300 sq m ISO Class 9 ("million class") cleanroom. - Annual production capacity: 500,000 cold plates; 50,000 CDUs. - Production line automation rate: above 60%. - CDU product portfolio: full power range from 30 kW to 1,500 kW. - Micro-module / containerized scenario claims: project delivery cycle compressed by more than 50%; room footprint reduced by 40%–60%. - Quality inspection processes cited: high-precision helium leak testing, coordinate measuring machine (CMM) inspection, full endoscopic inspection, MES full-chain traceability, CCD vision inspection. - No financial figures, market share data, customer names, or order values were disclosed. ### Why it matters to ebm-papst Haiwu is a Chinese thermal management vendor moving aggressively into the AI data center liquid cooling value chain, and its public emphasis on full-stack integration — cold plates, CDUs, piping, controls, and cooling sources — signals a competitive dynamic in which hardware components are increasingly bundled into integrated solutions rather than sold as standalone parts. Assessment (inference): For ebm-papst, the most direct read-through is on the air-moving side of the cooling chain. Haiwu's roadmap explicitly frames liquid cooling as displacing traditional air cooling at the high-density end, and its retrofit scenario still relies on airflow optimization as the first step of a phased migration. That creates a near-term demand window for high-efficiency fans and blowers in hybrid air-liquid rooms, but a longer-term risk that rack-level and room-level fan content per kilowatt declines as liquid cooling penetration rises in AI clusters. Assessment (inference): Haiwu's stated CDU power range up to 1,500 kW and its 50,000-unit annual CDU capacity indicate it is targeting large AIDC campuses, not only edge or micro-module deployments. CDUs and liquid cooling loops still require dry coolers, air-cooled chillers, and heat rejection fans, which is where ebm-papst's cooling-source and condenser fan portfolio could remain relevant even in a liquid-cooled architecture. Assessment (inference): The scenario-based, phased approach Haiwu promotes — airflow optimization first, then targeted rack liquid cooling, then full-room liquid cooling — suggests Chinese data center operators will run mixed air and liquid environments for years. Suppliers that can serve both sides of that transition, with efficient EC fans and controls for hybrid rooms, are better positioned than those betting purely on one cooling modality. Assessment (inference): Haiwu's emphasis on domestic manufacturing scale, cleanroom capacity, and inspection processes also signals that Chinese liquid cooling supply chains are maturing quickly, which could intensify price pressure on imported thermal components in the China AI data center market. ebm-papst should treat Haiwu as both a potential channel partner for heat-rejection air movement and a competitor for thermal budget share in Chinese AIDC projects.

## Full text (English translation)

Five-Layer Closed Loop, Scenario-Intelligent Drive | Haiwu's Full-Stack Liquid Cooling System Solution Safeguards the High-Quality Development of AI Computing Room Heat Dissipation

Published: 2026-09-02

As the artificial intelligence industry iterates rapidly, computing power — the core engine of the digital economy and new-quality productive forces — continues to drive up single-rack power consumption. The large-scale deployment of high-density computing clusters brings new opportunities for China's new digital infrastructure construction, but also poses severe heat dissipation challenges. Traditional air-cooling solutions are gradually hitting the energy efficiency ceiling, and energy saving and carbon reduction, long-term stable operation, and full-lifecycle TCO optimization of data centers have become core propositions for industry development. Responding to the national dual-carbon strategy and promoting the green and low-carbon transformation of computing infrastructure is both an inevitable direction for industry development and a social responsibility borne by technology enterprises.

Drawing on years of deep experience in thermal management for computing infrastructure, Haiwu breaks away from the traditional misconception that "liquid cooling equals cold plates plus simple stacking of CDU hardware," and innovatively proposes the advanced concept of full-stack liquid cooling, building an end-to-end thermal management closed-loop system from chip heat dissipation to environmental heat exhaust. The solution fully covers five layers: device layer, rack layer, room layer, cooling source layer, and O&M layer. Relying on deep coordinated interaction among multiple modules — cold plates, CDU liquid cooling distribution units, liquid cooling piping networks, intelligent control platforms, and high-efficiency cooling source systems — it precisely achieves efficient heat transfer and dynamic control, delivering integrated liquid cooling solutions that are highly energy-efficient, highly reliable, and sustainably evolvable for various AI computing centers and data centers, achieving a win-win of computing performance release and low-carbon emission reduction.

Haiwu adheres to a core judgment: there is no universal standard answer for liquid cooling solutions; the scenario determines the technical path. Different computer rooms differ in construction stage, computing business planning, site resource conditions, and investment pace, and a generalized liquid cooling architecture can hardly match a project's long-term return objectives. Based on accumulated experience from massive engineering deployments, Haiwu has built a systematic, scenario-based methodology, delivering differentiated and customized liquid cooling construction paths for four mainstream computing scenarios in the industry, truly making the solution fit the project rather than the project accommodating the solution.

For existing computer room retrofit scenarios, many traditional air-cooled rooms urgently need to be upgraded to carry high-density AI computing, yet commonly face pain points such as high risk of shutdown during retrofit, waste of existing assets, and long construction cycles. Haiwu adopts a modular CDU rapid deployment solution, combined with plate heat exchanger isolation technology and zoned dynamic control strategies, to achieve smooth non-stop upgrade of the computer room, maximize the utilization of existing air-cooled infrastructure assets, ensure continuous operation of core business, and steadily complete high-density computing expansion.

For new-build AIDC intelligent computing park scenarios, Haiwu intervenes in the park's top-level design at an early stage of solution planning, coordinating the liquid cooling system architecture layout from the project source, maximizing the exploitation and utilization of outdoor free cooling sources, and pairing this with AI intelligent control strategies to reduce annual energy consumption from the source of refrigeration, creating for customers a modern liquid cooling computing infrastructure oriented toward future computing iteration and with long-term low-carbon operation potential.

In micro-module and containerized data center scenarios, relying on the highly integrated prefabricated design of the liquid cooling system, the project delivery cycle can be compressed by more than 50%, and the computer room footprint reduced by 40%–60%. It also supports elastic computing expansion, can quickly respond to urgent production demands such as edge computing and short-term burst computing, and greatly shortens the computing deployment cycle.

For customers whose computing planning proceeds gradually, Haiwu launches a progressive evolution solution, providing a phased upgrade route: starting from computer room airflow optimization, transitioning to local liquid cooling retrofit of high-power critical racks, and finally completing full-room liquid cooling upgrade, helping customers scientifically control investment pace, balance early-stage investment and long-term returns, and effectively avoid the investment risk brought by one-time large-scale retrofit.

As a comprehensive service provider for the full lifecycle of data centers, Haiwu's full-stack liquid cooling capability is not limited to the manufacturing and supply of hardware products, but also builds a complete service value chain covering consulting and design, solution planning, engineering construction, and O&M optimization. Relying on six core capabilities — a standard technology library, a professional engineering delivery system, liquid cooling safety control logic, refined management of water quality and reliability, and consulting and design enablement — it continuously delivers to the industry batch after batch of replicable, verifiable, and sustainably evolvable liquid cooling benchmark projects, laying a solid engineering foundation for the large-scale commercial deployment of liquid cooling technology.

Behind the strong solution deployment is the support of hardcore intelligent manufacturing strength and a strict quality control system. Haiwu has built a 2,200 sq m ISO Class 7 (ten-thousand class) cleanroom and a 4,300 sq m ISO Class 9 (million class) cleanroom, with strong large-scale production capacity: annual capacity can reach 500,000 cold plates and 50,000 CDUs, and the production line automation rate exceeds 60%. Its CDU product matrix fully covers the 30–1,500 kW power range, adapting to diverse computing loads from small computer rooms to large intelligent computing parks. In the product quality inspection process, multiple inspection procedures are implemented, including high-precision helium leak testing, coordinate measuring machine inspection, full endoscopic inspection, MES full-chain production traceability, and CCD vision inspection, checking layer by layer to comprehensively improve the cleanliness, operational reliability, and batch consistency of liquid cooling core components, ensuring the liquid cooling system operates stably for years without issue.

If computing thrives, the digital economy thrives; if infrastructure is strong, the industrial foundation is strong. Standing at the era's风口 of rapid AI computing expansion, thermal management innovation has become a key factor in measuring the core competitiveness of data centers. In the future, Haiwu will continue to deepen its cultivation in the track of full-stack liquid cooling technology innovation, adhere to the development direction of scenario-driven technology evolution and full-stack capability empowering green computing, continuously iterate and improve multi-scenario liquid cooling system engineering solutions, and join hands with industry ecosystem partners to jointly advance the efficient and low-carbon transformation of China's computing infrastructure, injecting a steady stream of green technology momentum into the construction of new digital infrastructure and the high-quality, sustainable development of the digital economy.

Related news More

## Full text (original)

五层闭环・场景智驱｜海悟全栈液冷系统方案，护航AI算力机房散热高质量发展                        
                        发布时间：2026-09-02
                            
                            
                        人工智能产业飞速迭代，算力作为数字经济、新质生产力发展的核心引擎，单机柜功耗持续攀升，高密度算力集群规模化落地，为我国新型数字基础设施建设带来全新机遇，也提出严峻的散热挑战。传统风冷散热方案逐步触及能效天花板，数据中心的节能降碳、长期稳定运营、全生命周期 TCO 优化，已经成为行业发展的核心命题。响应国家双碳战略号召，推动算力基础设施绿色低碳转型，既是产业发展的必然方向，也是科技企业肩负的社会责任。
海悟立足多年算力基础设施热管理深耕经验，跳出 “液冷等于冷板、CDU 硬件简单叠加” 的传统误区，创新性提出全栈液冷先进理念，打造一套从芯片散热到环境排热的端‑到‑端热管理闭环体系海悟。方案完整覆盖器件层、机柜层、机房层、冷源层、运维层五大层级，依托冷板、CDU 液冷分配单元、液冷管网、智能控制平台、高效冷源系统多模块深度协同联动，精准完成热量高效传递、动态管控，为各类 AI 算力中心、数据中心交付高能效、高可靠、可持续演进的一体化液冷解决方案，实现算力性能释放与低碳减排双向共赢。
海悟坚持核心研判：液冷方案不存在万能标准答案，场景决定技术路径。不同机房所处建设阶段、算力业务规划、场地资源条件、投资节奏各不相同，通用化液冷架构很难匹配项目长期收益目标。基于海量工程落地实践沉淀，海悟搭建起系统化场景化方法论，面向行业四大主流算力场景输出差异化、定制化液冷建设路径，真正做到方案适配项目，而非项目迁就方案。
面向存量机房改造场景，大量传统风冷机房迫切需要升级承载高密度 AI 算力，却普遍遭遇停机改造风险高、原有资产浪费、施工周期长等痛点。海悟采用模块化 CDU 快速部署方案，搭配板式换热隔离技术与分区动态调控策略，实现机房不停机平滑升级，最大限度盘活原有风冷基础设施资产，保障核心业务连续运行，稳妥完成高密度算力扩容。
针对新建 AIDC 智算园区场景，海悟将方案规划工作前置介入园区顶层设计，从项目源头统筹液冷系统架构布局，最大化挖掘、利用室外自然冷源，配套 AI 智能调控策略，从制冷本源降低全年能耗水平，为客户打造面向未来算力迭代、具备长期低碳运营潜力的现代化液冷算力基础设施。
在微模块与集装箱数据中心场景，依托液冷系统高度集成化预制设计，项目交付周期可压缩 50% 以上，机房占地面积减少 40%‑60%，同时支持算力弹性扩容，能够快速响应边缘算力、短期爆发式算力等紧迫投产需求，大幅缩短算力落地周期。
对于算力规划循序渐进的客户，海悟推出渐进式演进解决方案，提供分阶段升级路线：由机房气流优化起步，过渡至高功耗关键机柜局部液冷改造，最终完成全机房液冷升级，帮助客户科学把控投资节奏，平衡前期投入与长期收益，有效规避一次性大规模改造带来的投资风险。
作为数据中心全生命周期综合服务商，海悟的全栈液冷能力不止局限于硬件产品制造供给，更构建了一条完整的服务价值链，覆盖咨询设计、方案规划、工程建设、运维优化全流程。依托标准技术库、专业工程交付体系、液冷安全控制逻辑、水质与可靠性精细化管理、咨询设计赋能等六大核心能力，持续向行业输出一批又一批可复制、可验证、可持续演进的液冷标杆项目，为液冷技术规模化商用落地筑牢工程底座。
强大的方案落地背后，离不开硬核智造实力与严苛品质管控体系保驾护航。海悟建成 2200㎡ ISO 7 级万级洁净室以及 4300㎡ ISO 9 级百万级洁净室，规模化生产能力强劲，年产能可达 50 万套冷板、5 万台 CDU，生产线自动化率超过 60%。旗下 CDU 产品矩阵全面覆盖 30‑1500kW 全功率段，适配从小型机房到大型智算园区的多样化算力负载。在产品质检环节，落地高精度氦检、三坐标检测、内窥镜全检、MES 生产全链路追溯、CCD 视觉检测多重检测工序，层层把关，全面提升液冷核心部件洁净度、运行可靠性以及产品批次一致性，保障液冷系统长年稳定运行无虞。
算力兴，则数字经济兴；基建强，则产业根基强。站在 AI 算力高速扩张的时代风口，热管理创新已经成为衡量数据中心核心竞争力的关键要素。未来，海悟将持续深耕全栈液冷技术创新赛道，坚守场景驱动技术演进、全栈能力赋能绿色算力的发展方向，不断迭代完善多场景液冷系统工程解决方案，携手产业链生态伙伴共同推进我国算力基础设施高效低碳转型，为新型数字基建建设、数字经济高质量可持续发展注入源源不断的绿色科技动能。