# China's Haiwu lands two multi-split HVAC systems in MIIT 2025 energy-saving catalogue, cutting energy 15% and hitting PUE near 1.2

- Source: Hiwave News (T1)
- Published: 2025-12-02
- Score: 53.0
- Tags: Policy / standards, Datacenter, HVAC
- Companies: Hiwave
- Original: https://www.haiwu.com/news/dynamic/1883.html

## Intelligence brief

### What happened China's Ministry of Industry and Information Technology (MIIT) released the 2025 edition of its Recommended Catalogue of Energy-Saving and Carbon-Reducing Technologies and Equipment for the industry and information technology sector. The catalogue is intended to accelerate deployment of advanced, applicable energy-saving and carbon-reduction technologies across key industries in support of green, low-carbon and circular development goals. Haiwu (Guangdong-based digital energy and clean energy technology supplier) announced that two of its solutions were selected for the catalogue: its Heat Pipe Multi-Split Air-Conditioning System technology and its Magnetic Bearing Phase-Change Multi-Split System. The announcement was dated 2 December 2025. The heat pipe multi-split system uses atomization cooling and inverter fluorine-pump equipment to exchange heat between high-temperature return air and liquid refrigerant at the terminal, cooling the indoor space. The liquid refrigerant absorbs heat and becomes gaseous, flows to a rooftop condenser for passive heat rejection, then condenses back to liquid to complete the cooling cycle. A distributed architecture with multi-split terminals is claimed to ensure stable operation and to provide dual-side (indoor and outdoor) redundancy for continuous cooling. The magnetic bearing phase-change multi-split system combines magnetic bearing variable-frequency drive, power heat pipe and evaporative condensing technologies. It runs oil-free, uses a multi-split terminal architecture, and offers configuration flexibility: the outdoor condensing side can use either an evaporative-cooling unit or an air-cooled unit, while indoor terminals can be room-level, row-based, air-wall or high-density near-end air-wall formats. The company states the magnetic bearing compressor eliminates mechanical friction losses and that direct-expansion heat exchange removes intermediate heat-exchange steps, improving system efficiency. ### Key figures - Energy consumption reduction of the heat pipe multi-split air-conditioning system: 15% (company claim). - Measured PUE of the magnetic bearing phase-change multi-split system in South China (Guangzhou, Guangdong): close to 1.2. - Measured PUE of the same system in Northwest China (Zhongwei, Ningxia): below 1.15. - Company history cited: 30 years of technology accumulation. - Catalogue edition: 2025 version, issued by MIIT. - No specific figures disclosed for investment amounts, production capacity, unit volumes or market share. ### Why it matters to ebm-papst This is a market signal that Chinese data-centre cooling vendors are increasingly packaging system-level, high-efficiency architectures (heat pipe, phase-change, magnetic bearing, evaporative condensing) and seeking official MIIT catalogue endorsement as a sales and credibility lever. Catalogue listing typically helps such solutions qualify for provincial energy-saving incentives, appear in public procurement shortlists and gain traction with Chinese hyperscalers and colocation operators. Assessment (inference): For ebm-papst, the direct competitive threat is limited in the short term because Haiwu's listed solutions are compressor- and refrigerant-loop-centric systems, not fan-centric products; however, these architectures still require EC fans, evaporative-condenser fans and high-density near-end air-wall fan arrays, so Haiwu remains a potential customer for high-efficiency fan and motor modules rather than a pure competitor. Assessment (inference): The PUE figures cited (near 1.2 in South China, below 1.15 in Northwest China) raise the efficiency benchmark that data-centre operators will expect from all subsystem suppliers, including fan walls and air handling units, which increases pressure on ebm-papst to demonstrate measurable PUE contribution per fan module. Assessment (inference): The explicit mention of multiple indoor terminal formats (room-level, row-based, air wall, high-density near-end air wall) indicates a growing addressable market for compact, high-static-pressure EC fan arrays in Chinese data centres, and ebm-papst should track Haiwu's project pipeline in Guangdong and Ningxia as an early indicator of demand for such fan platforms. Assessment (inference): Because MIIT catalogue inclusion is a recurring annual mechanism, similar listings by other Chinese cooling vendors should be expected, and ebm-papst's China team may benefit from mapping which listed systems use third-party fans versus in-house fan designs.

## Full text (English translation)

Recently, the Ministry of Industry and Information Technology released the Recommended Catalogue of Energy-Saving and Carbon-Reducing Technologies and Equipment in the National Industry and Information Technology Field (2025 Edition), aimed at accelerating the promotion and application of advanced and applicable energy-saving and carbon-reducing technologies and equipment in the industry and information technology field, supporting key industries in advancing energy-saving and carbon-reduction work, and helping to achieve the goals of green, low-carbon and circular development.

Haiwu's heat pipe multi-split air-conditioning system technology and magnetic bearing phase-change multi-split system were selected for the energy-saving recommendation catalogue.

Heat Pipe Multi-Split Air-Conditioning System Technology

Haiwu's heat pipe multi-split air-conditioning system technology adopts atomization cooling, inverter fluorine pump and other technical equipment to exchange heat between high-temperature return air and liquid refrigerant at the terminal, reducing the indoor temperature. After absorbing heat, the liquid refrigerant becomes gaseous refrigerant, flows to the rooftop condenser for natural heat dissipation, and after cooling forms liquid refrigerant to circulate for cooling. Through a distributed architecture and multi-split terminal design, it can both ensure stable operation of the cooling system and achieve dual-side backup indoors and outdoors, guaranteeing continuous cooling, and can reduce air-conditioning system energy consumption by 15%.

Schematic diagram of the heat pipe multi-split air-conditioning system architecture

Magnetic Bearing Phase-Change Multi-Split System

Haiwu's magnetic bearing phase-change multi-split system integrates multiple energy-saving technologies such as magnetic bearing variable frequency, power heat pipe, and evaporative condensing, achieving excellent energy efficiency performance under various load conditions. The system runs oil-free, has a multi-split terminal architecture, and offers a high degree of configuration flexibility: the outdoor condensing side can choose an evaporative cooling main unit or an air-cooled main unit, and the indoor terminal side can choose various terminal forms such as room-level, row-based, air wall, and high-density near-end air wall, giving the system adaptability for full-scenario applications.

Magnetic bearing phase-change multi-split system

The technological breakthrough at the product level is mainly reflected in the use of magnetic bearing compressors to completely eliminate energy losses caused by mechanical friction, combined with direct expansion heat exchange, reducing intermediate heat exchange links and greatly improving system energy efficiency. Data shows that the system achieved a measured PUE close to 1.2 in South China and a measured PUE below 1.15 in Northwest China, demonstrating outstanding energy-saving performance.

Guangzhou, Guangdong

Zhongwei, Ningxia

Haiwu always adheres to the R&D direction of "customer needs + market orientation," regards technological innovation as the first driving force for enterprise development, and after thirty years of technological accumulation and precipitation has formed strong product competitiveness and technological innovation capability in the industry. Haiwu will continue to uphold the mission of "leading new technologies in digital energy and clean energy, creating a new green and intelligent environment," accelerate the efficient transformation and wide application of scientific and technological achievements, provide the data center industry with more reliable, efficient, and intelligent energy-saving and carbon-reducing technologies and solutions, contribute to the green transformation of China's industry and information technology field, and help achieve the "dual carbon" goals on schedule.

## Full text (original)

近日，国家工业和信息化部发布了《国家工业和信息化领域节能降碳技术装备推荐目录(2025年版)》，旨在加快推广先进适用的节能降碳技术装备在工业和信息化领域的应用，支持各重点行业推进节能降碳工作，助力实现绿色、低碳、循环发展的目标。
海悟热管多联空调系统技术和磁悬浮相变多联系统入选节能推荐目录。
热管多联空调系统技术
海悟热管多联空调系统技术采用雾化冷却、变频氟泵等技术装备，将高温回风与末端液态冷媒进行换热，降低室内温度。液态冷媒吸热后变为气态冷媒，流向屋顶的冷凝器自然散热，冷却后形成液态冷媒循环制冷。通过分布式架构与末端多联设计，既能确保制冷系统稳定运行，又能实现室内外双侧备份，保障连续制冷，可降低空调系统能耗15%。
热管多联空调系统架构示意
磁悬浮相变多联系统
海悟磁悬浮相变多联系统融合了磁悬浮变频、动力热管、蒸发冷凝等多项节能技术，实现了设备在各种负载条件下的卓越能效表现。系统无油运行，末端多联架构，具备高度的配置灵活性：室外冷凝侧可选蒸发冷主机或风冷主机，室内末端侧可选房级、列间、风墙、高密近端风墙等多种末端形式，赋予系统全场景应用的适应能力。
磁悬浮相变多联系统
产品层面的技术突破主要体现在采用磁悬浮压缩机彻底消除机械摩擦带来的能量损失，配合直膨换热方式，减少中间换热环节，使系统能效大幅提升。数据显示，该系统在华南地区落地实测PUE接近1.2，西北地区落地实测PUE低于1.15，展现了出色的节能性能。
广东·广州
宁夏·中卫