What happened At the 2025 Global Digital Infrastructure Cooperation and Development Beijing Forum, industry experts highlighted that green energy management is becoming a mandatory requirement for data center projects going overseas. The forum featured speakers from Rui Technology (Rui Ji Ke Ji), DITC, Peking University, Amazon Web Services, GALAXY DATA CENTER, and others. They discussed how renewable energy availability, carbon compliance, and liquid cooling are reshaping the criteria for data center site selection and approval, particularly in regions like Singapore, Europe, and the Middle East. The event underscored that green electricity assessment is now a standard prerequisite before project initiation, and that AI-driven energy consumption is forcing dual-track solutions: reducing total energy use and increasing the share of green power. ### Key figures - Global data center IT load reached 64 GW in 2025, expected to exceed 100 GW by 2028. - AI workloads consume 10–30 times more energy than traditional computing. - Latest AI chips consume up to 300% more energy than previous generations. - In the US, many new data center projects are fully liquid-cooled; Google and Amazon have over 60% liquid cooling adoption. - Traditional data center power density: 5–15 kW per rack with air cooling; AI data centers require 15–25 kW per rack with liquid cooling. - AWS commits to net-zero carbon by 2040. - ARM chips reduce power consumption by 60% compared to x86 chips. - Singapore uses a "Green Data Center Roadmap" and DC-CFA centralized approval with capacity quotas, requiring high energy efficiency and low carbon emissions. - No specific figures disclosed for green electricity pricing or capacity. ### Why it matters to ebm-papst The shift toward green energy and liquid cooling as prerequisites for data center projects presents both opportunities and challenges for ebm-papst. As a leading manufacturer of fans and motors, ebm-papst's high-efficiency EC fans and cooling solutions are critical for reducing energy consumption in data centers. The growing emphasis on liquid cooling may reduce demand for traditional air-cooling fans, but ebm-papst can pivot by offering components for liquid cooling systems, such as pumps or specialized fans for hybrid cooling. The requirement for lower carbon footprint and higher energy efficiency aligns with ebm-papst's product strengths. Assessment (inference): The trend toward green electricity and liquid cooling could shift demand away from standard air-moving products toward more integrated thermal management solutions. ebm-papst should monitor the adoption rate of liquid cooling versus air cooling in different regions and invest in R&D for liquid cooling-compatible components. The emphasis on full lifecycle carbon accounting may also increase demand for energy-efficient fans with lower embodied carbon, which ebm-papst can capitalize on by promoting its green manufacturing and product efficiency.
原文全文
原文
英文翻译
2025年全球算力中心IT负载已达64GW,预计2028年将突破100GW。在这场规模空前的算力全球化竞赛中,绿色能源已逐渐成为企业出海项目落地的“硬约束”。
在日前举行的2025全球数字基础设施合作发展北京论坛上,瑞技科技数据中心解决方案总监赵春晓分享了瑞技科技在出海过程中的观察。他表示,绿色能源转型已成为国际竞争的优势之一。以德国和爱尔兰为例,因为有较高的可再生能源比例和适宜气候条件,吸引了很多科技巨头投资。
DITC副主席、北京大学能源系主任杨荣贵则将绿色低碳定义为必须回答的时代命题。从欧盟的严苛碳排放标准,到东南亚国家对煤电投资的担忧,再到中东市场对可再生能源配套的要求,绿电管理正在重新定义算力出海的准入规则。
项目落地前的绿电评估已成标配
算力出海项目在启动建设前,绿色能源配套方案已成为工程评估的必选项。这种转变体现在评估体系、政府审批、验收标准三个层面。
杨荣贵教授提出,在项目落地前开始质量与合规的预评估,将许可流程、电路接入、可再生能源的可用性、能效约束等要素整合为工程雷达图。在这个评估框架中,将可再生能源的可用性与许可流程、电路接入并列为核心变量。
他强调,很多难题如果在前期做好充分对齐,建设过程中就不再是难题,缺乏前期对齐往往演变成长期风险。
以新加坡为例,新加坡通过“绿色数据中心路线图”和 DC-CFA 集中审批机制,对新增数据中心项目实行容量配额,并要求新项目达到高能效和低碳排放阈值,明确将“采用绿电或低碳电力方案”作为评审重点之一,未能证明能源与碳绩效达标的项目难以获批。
评估标准的要求进一步印证了了绿电的重要性。杨荣贵教授提出建立超越单一PUE指标的评价体系,将高可用性、可维护性、运维可靠性与全生命周期碳足迹纳入总体框架下优化。
DITC亚太观察员杨培锋指出,国际政策、国际形势对碳中和、DPUE、新能源技术提出了更大的要求,需要在硬件和架构设计上加大投入。这种评价体系的变化,使得数据中心不仅要关注运营期电力使用效率,还需核算全生命周期碳足迹,绿电配套成为降低碳足迹的关键手段。
能耗暴增倒逼双轨应对
生成式AI消耗的能源是传统算力工作的10到30倍,最新AI芯片的耗能比前一代高达300%。AI算力的能耗突破传统数据中心承载极限,企业必须在降低总能耗和提高绿电比例两个方向同时发力,形成系统性解决方案。
赵春晓介绍,美国很多新建项目已全部采用液冷,Google、亚马逊等数据中心液冷比例已达60%以上,这已经是一种国际通用的先进架构。
杨培峰指出,针对中国企业全产业链出海的战略需求,应重点整合包括液冷技术在内的绿色节能方案。通过将绿色能源供给与算力运营深度结合,以应对国际市场对高能效、低碳排基础设施的严苛要求。
而液冷的采用不仅仅是服务器本身的改造。新意网业务拓展(大中华区)副总裁Coco Cheng表示,传统数据中心功率密度为每机柜5到15千瓦,采用空气冷却,地板承重7到12千帕。AI数据中心主要利用液冷,地板承重需达15到25千帕,数据中心建设同样需要跟进。
液冷降低总能耗的同时,企业还需在绿电采购上发力。亚马逊云科技计算与云原生产品总监张洋介绍,AWS承诺2040年实现净零碳排放。具体措施包括采购绿色能源,在机房运行上对水、二氧化碳排放采取措施。
张洋提到了设备层面的能效优化,设备层面采用液冷技术,CPU采用ARM芯片,ARM芯片比传统X86芯片耗电量降低60%。资源调度上,通过智能算法和竞价实例充分利用资源,保证电力进来后完全发挥经济价值。
从嘉宾的分享中,可以明显看出区域实践的差异。东南亚地区因数据中心用电规模大,普通光伏或绿电对数据中心的支撑只能做部分少量配套。而中东地区数据中心直接配套绿电的项目则比较多。
从技术输出到生态赋能
随着算力基建的落成,当地市场面临的最紧迫挑战将从“建设开发”转向“运营治理”。中国在光伏、储能等绿电相关领域的技术积累和产业化能力,正在转化为算力出海的差异化竞争力。
以GALAXY DATA CENTER东南亚项目为例,根据首席发展与营销官Jeffrey Tay的介绍,东南亚国家对绿色能源技术有明确需求,但普遍面临本地技术积累不足的瓶颈。依托国内成熟的光伏经验,GALAXY DATA CENTER为当地引入了成熟的绿电运营管理经验,更通过数字化管理平台解决了能效管理难题。
他举例表示,在波动的AI算力需求下,实现煤电与绿电的动态平衡,就需要精细化的管理能力。GALAXY DATA CENTER的管理平台能够管理碳排放与碳中和进程,同时,还能评估AI运算所消耗的煤电与绿电比例,并对此进行平衡与优化。
硬件与软件的输出仅是起点,不仅是绿电管理经验,本土化人才培育也是算力生态出海中的一个重要部分,中国企业的竞争优势不应仅止于基础设施的物理交付,更应通过“知识转移”赋能当地,协同当地培养专业管理人才,破解其管理能力缺失的后顾之忧。
杨荣贵教授提出的全球化模式为这种生态构建提供了方法论。他建议坚持全球统一内核加本地化扩展的模式,将安全、可靠、运维、绿色等核心能力构建为全球统一的内核,在各区域以灵活扩展包适配当地的数据治理、能效政策。这意味着中国企业的绿电能力不是单点技术,而是硬件+软件(管理平台)+服务(生态构建、人才培养)的完整解决方案。
当技术与人才形成规模效应,中国经验的最终形态表现为对行业标准的定义权。杨荣贵教授倡议启动AI数据中心质量与能效基准试点,不同气候、不同电力结构、不同负载形态的站点共同参与,完善评估体系,为统一国际标准奠定基础。同时共建液冷系统协同验证平台,围绕关键材料、工艺与监测,建立跨厂商链条共享机制。
这种以人才为基石、以产业链为支撑的标准构建,将引领中国算力出海企业从“规则适应者”到“标准制定者”,构筑更坚实的竞争优势。
Green Electricity Management Is Becoming a Ticket for Computing Power Going Overseas
In 2025, the global data center IT load has reached 64 GW, and it is expected to exceed 100 GW by 2028. In this unprecedented global competition of computing power, green energy has gradually become a "hard constraint" for enterprises' overseas project implementation.
At the recently held 2025 Global Digital Infrastructure Cooperation and Development Beijing Forum, Zhao Chunxiao, Director of Data Center Solutions at Rui Technology, shared observations from the company's overseas expansion. He stated that green energy transformation has become one of the advantages in international competition. For example, Germany and Ireland, with their high proportions of renewable energy and suitable climate conditions, have attracted many tech giants to invest.
Yang Ronggui, Vice Chairman of DITC and Director of the Department of Energy at Peking University, defined green and low-carbon as a proposition of the era that must be answered. From the EU's stringent carbon emission standards, to Southeast Asian countries' concerns about coal power investment, to the Middle East market's requirements for renewable energy supporting facilities, green electricity management is redefining the access rules for computing power going overseas.
Green electricity assessment before project implementation has become standard
Before the start of construction for computing power overseas projects, green energy supporting solutions have become a mandatory item in engineering evaluation. This change is reflected in three aspects: evaluation system, government approval, and acceptance standards.
Professor Yang Ronggui proposed conducting pre-evaluation of quality and compliance before project implementation, integrating elements such as permitting process, circuit access, renewable energy availability, and energy efficiency constraints into an engineering radar chart. In this evaluation framework, the availability of renewable energy is listed as a core variable alongside permitting process and circuit access.
He emphasized that many problems can be avoided if thorough alignment is done in the early stage; lack of early alignment often evolves into long-term risks.
Taking Singapore as an example, Singapore implements capacity quotas for new data center projects through its "Green Data Center Roadmap" and DC-CFA centralized approval mechanism, requiring new projects to meet high energy efficiency and low carbon emission thresholds. It explicitly lists "adopting green electricity or low-carbon electricity solutions" as one of the review priorities. Projects that cannot demonstrate energy and carbon performance compliance are difficult to approve.
The requirements of evaluation standards further confirm the importance of green electricity. Professor Yang Ronggui proposed establishing an evaluation system that goes beyond the single PUE indicator, optimizing high availability, maintainability, operational reliability, and full lifecycle carbon footprint within an overall framework.
Yang Peifeng, DITC Asia-Pacific Observer, pointed out that international policies and situations impose greater requirements on carbon neutrality, DPUE, and new energy technologies, necessitating increased investment in hardware and architecture design. This change in the evaluation system means data centers must not only focus on operational power usage efficiency but also account for full lifecycle carbon footprint, making green electricity supporting a key means to reduce carbon footprint.
Soaring energy consumption forces dual-track response
Generative AI consumes 10 to 30 times more energy than traditional computing workloads, and the latest AI chips consume up to 300% more energy than previous generations. AI computing power's energy consumption exceeds the limits of traditional data centers, forcing enterprises to simultaneously reduce total energy consumption and increase the proportion of green electricity, forming a systematic solution.
Zhao Chunxiao introduced that many new projects in the US have fully adopted liquid cooling, and data centers of Google, Amazon, etc., have over 60% liquid cooling adoption, which has become an internationally common advanced architecture.
Yang Peifeng pointed out that to meet the strategic needs of Chinese enterprises' full industry chain overseas expansion, green and energy-saving solutions including liquid cooling technology should be integrated. By deeply combining green energy supply with computing power operations, they can meet the stringent international market requirements for high energy efficiency and low carbon infrastructure.
The adoption of liquid cooling is not just about server modification. Coco Cheng, Vice President of Business Development (Greater China) at iAdvantage, stated that traditional data centers have power densities of 5 to 15 kW per rack with air cooling and floor load capacity of 7 to 12 kPa. AI data centers mainly use liquid cooling, requiring floor load capacity of 15 to 25 kPa, so data center construction also needs to keep up.
While liquid cooling reduces total energy consumption, enterprises also need to increase green electricity procurement. Zhang Yang, Director of Computing and Cloud Native Products at AWS China, introduced that AWS has committed to achieving net-zero carbon emissions by 2040. Specific measures include purchasing green energy and taking actions on water and carbon dioxide emissions in data center operations.
Zhang Yang mentioned equipment-level energy efficiency optimization, such as using liquid cooling technology and ARM chips, which consume 60% less power than traditional x86 chips. In resource scheduling, intelligent algorithms and spot instances are used to fully utilize resources, ensuring that electricity is fully utilized economically.
From the speakers' sharing, regional differences are evident. In Southeast Asia, due to the large scale of data center electricity consumption, ordinary photovoltaic or green electricity can only provide partial support. In the Middle East, more data center projects directly pair with green electricity.
From technology output to ecosystem empowerment
With the completion of computing power infrastructure, the most urgent challenge for local markets will shift from "construction and development" to "operation and governance." China's technological accumulation and industrialization capabilities in green electricity-related fields such as photovoltaics and energy storage are transforming into differentiated competitiveness for computing power going overseas.
Taking GALAXY DATA CENTER's Southeast Asia project as an example, according to Jeffrey Tay, Chief Development and Marketing Officer, Southeast Asian countries have clear demand for green energy technology but generally face bottlenecks due to insufficient local technical accumulation. Leveraging mature domestic photovoltaic experience, GALAXY DATA CENTER introduced mature green electricity operation and management experience to the local area, and solved energy efficiency management challenges through a digital management platform.
He gave an example: under fluctuating AI computing power demand, achieving dynamic balance between coal power and green electricity requires refined management capabilities. GALAXY DATA CENTER's management platform can manage carbon emissions and carbon neutrality processes, and also evaluate the proportion of coal power and green electricity consumed by AI computing, balancing and optimizing them.
Hardware and software output is just the starting point. Not only green electricity management experience, but also localized talent cultivation is an important part of the computing power ecosystem going overseas. Chinese enterprises' competitive advantage should not be limited to physical delivery of infrastructure; they should empower local areas through "knowledge transfer" and collaborate to cultivate local professional management talent, alleviating concerns about management capability gaps.
Professor Yang Ronggui's proposed globalization model provides a methodology for this ecosystem building. He suggested adhering to a model of "global unified core plus localized expansion," building core capabilities such as safety, reliability, operations, and green into a globally unified core, and adapting to local data governance and energy efficiency policies through flexible expansion packages in each region. This means Chinese enterprises' green electricity capability is not a single-point technology but a complete solution of hardware + software (management platform) + service (ecosystem building, talent cultivation).
When technology and talent achieve scale effects, the ultimate form of Chinese experience is the definition of industry standards. Professor Yang Ronggui proposed initiating pilot projects for AI data center quality and energy efficiency benchmarks, with sites of different climates, power structures, and load types participating together to improve the evaluation system and lay the foundation for unified international standards. At the same time, jointly build a collaborative verification platform for liquid cooling systems, establishing cross-supplier chain sharing mechanisms around key materials, processes, and monitoring.
This standard building, based on talent and supported by the industry chain, will lead Chinese computing power overseas enterprises from "rule adapters" to "standard setters," building a more solid competitive advantage.