Johnson Controls launches air-cooled chiller guide for 1-GW AI factories, citing 32% energy savings
Intelligence brief
What happened Johnson Controls has released the second installment in its AI Factory Reference Design Guide Series, this one focused on air-cooled chillers for data center thermal management. The guide follows the company's water-cooled chiller guide, published in February, and sits within a planned series that will additionally address absorption chillers and direct-to-chip liquid cooling. Announced in May 2026, the guide is positioned to support scalable data center designs up to a 1-GW AI factory using air-cooled chillers. The document outlines a thermal cooling architecture that combines high-efficiency air-cooled YORK centrifugal chillers, including the YDAM and YVAM models, with fan coil walls and coolant distribution units to manage both air- and liquid-cooled IT loads. Johnson Controls said the guide provides sizing references for 220 MW compute clusters, including recommended design temperatures and operating conditions across each stage of the thermal chain. Austin Domenici, president of Johnson Controls Global Data Center Solutions, framed the release around the infrastructure demands of gigawatt-scale AI facilities, saying such projects require integrated systems that scale predictably, perform efficiently and adapt as technology evolves. ### Key figures - Scalable design support: up to a 1-GW AI factory using air-cooled chillers - Sizing references provided for 220 MW compute clusters - 50 MW returned to the AI factory through bifurcated loops for air- and liquid-cooling systems - 32% improvement in annual energy consumption via intelligent use of redundant chillers - 20 MW stated peak power savings from addressing heat island effects in air-cooled chiller plants - Zero water usage from eliminating cooling towers, saving more than 12 million gallons daily - 30% coefficient of performance improvement from raising chilled water temperature for warm-water Technology Cooling System loops - 27% reduction in the number of chillers under that same warm-water approach - Guide series timeline: water-cooled chiller guide released February 2026; absorption chiller and direct-to-chip liquid cooling guides planned ### Why it matters to ebm-papst This release is a market signal that the data center cooling conversation is shifting toward air-cooled architectures at gigawatt scale, explicitly to eliminate cooling towers and water consumption. Air-cooled chiller plants and the fan coil walls and coolant distribution units described in the guide are fan-intensive systems, which places air-movement components at the center of the thermal chain Johnson Controls is standardizing. For ebm-papst, this is primarily a customer-opportunity signal: OEMs building air-cooled chiller packages, fan coil walls and CDUs around reference designs like this one will specify fans for high-efficiency, low-power operation, and the guide's emphasis on power savings and COP improvement aligns with fan efficiency as a design lever. Assessment (inference): The explicit targets of 20 MW peak power savings and 32% annual energy consumption improvement suggest that component-level efficiency, including fan and motor efficiency, will face tighter specification pressure in these reference designs, and suppliers able to document measurable contributions to those figures may gain preference. Assessment (inference): The planned direct-to-chip liquid cooling guide is a watch item, since broader liquid cooling adoption could reduce air-side fan content per rack even as total facility scale grows. Assessment (inference): Johnson Controls is positioning itself as a design-authority player in AI factory thermal management; ebm-papst should track whether these guides name or imply preferred component vendors, as that could shape specification access for fan suppliers in the data center segment.
Full text
Johnson Controls has launched the second guide in its AI Factory Reference Design Guide Series, focused on air-cooled chillers for data center thermal management. The guide follows the company’s water-cooled chiller guide released in February and is part of a planned series that will also cover absorption chillers and direct-to-chip liquid cooling.
The new guide supports scalable data center designs up to a 1-GW AI factory using air-cooled chillers. It outlines a thermal cooling architecture combining high-efficiency air-cooled YORK centrifugal chillers, including YDAM and YVAM models, fan coil walls and coolant distribution units to manage both air- and liquid-cooled IT loads.
Johnson Controls said the guide provides sizing references for 220 MW compute clusters, including recommended design temperatures and operating conditions across each stage of the thermal chain. The company said the design can return 50 MW to the AI factory through bifurcated loops for air- and liquid-cooling systems and improve annual energy consumption by 32% through intelligent use of redundant chillers.
The guide also addresses heat island effects in air-cooled chiller plants, with stated peak power savings of 20 MW. Johnson Controls said eliminating cooling towers enables zero water usage and can save more than 12 million gallons daily. Raising chilled water temperature to support warm-water Technology Cooling System loops can improve coefficient of performance by 30% and reduce the number of chillers by 27%, according to the company.
“At gigawatt scale, AI factories require a fundamentally different way of thinking about infrastructure,” said Austin Domenici, president, Johnson Controls Global Data Center Solutions. “The future requires designing integrated systems that can scale predictably, perform efficiently and adapt as technology evolves. This guide reflects how Johnson Controls helps customers plan holistically for AI growth, from design to operations, anywhere in the world.”
Learn more about Johnson Controls’s Reference Guide Series at www.johnsoncontrols.com/industries/data-centers/reference-designs.