Vertiv 推出面向数据中心的中压 UPS PowerNexus

Vertiv launches PowerNexus MV UPS for AI data centres, claiming 98.5% peak efficiency and 4-hour battery backup
聚合·VertivT22026-11-20 · INTL · Vertiv 维谛技术
新品技术发布数据中心/IT散热

情报详报

What happened Vertiv has launched the PowerNexus MV UPS, an outdoor-rated medium-voltage uninterruptible power supply platform aimed at colocation, neocloud and hyperscale data centre operators. The system combines UPS functionality, fault ride-through and AI power smoothing in a single unit designed to sit at the utility connection point, freeing indoor floor space for compute equipment. The launch was announced with reference to growing pressure on operators to secure grid connections, manage fluctuating power demands from AI workloads and use building space more efficiently. Vertiv positions the product as a system-level response to grid queues, indoor space constraints and evolving grid requirements. Vertiv recently ran proof-of-concept demonstrations with QTS, SoftBank and Rosendin at its Global Power R&D and Customer Experience Centre in Bologna, Italy. The tests covered steady-state and dynamic conditions and, according to Vertiv, showed stable performance across loads from 0% to 100%, Class 1 voltage accuracy during rapid load changes, and ride-through of severe voltage disturbances including a full voltage sag for 150 milliseconds and a 25% overvoltage lasting five seconds. QTS's Ryan Kuithe, Senior Vice President of Facilities Operations, endorsed the system's performance through dynamic load changes and voltage disturbances. Vertiv also highlighted plans for a dedicated medium-voltage laboratory at its Bologna large power research and customer centre, intended to support R&D, full-voltage validation, customer demonstrations, service training and system-level testing for MV UPS, MV to 800 VDC and battery energy storage technologies. A Power Systems Computer Aided Design model is being offered so customers can simulate system behaviour and validate integration before deployment. ### Key figures - Up to 98.5% peak operating efficiency, per Vertiv. - Battery-backed operation for up to four hours when paired with long-duration battery systems. - Proof-of-concept testing covered loads from 0% to 100%. - Tested ride-through of a full voltage sag for 150 milliseconds and a 25% overvoltage lasting five seconds. - Output voltage quality designed to Class 1 in line with IEC 62040-3. - Planned medium-voltage laboratory at the Bologna facility; no investment figure or timeline disclosed. - No pricing, order volume or revenue figures disclosed. ### Why it matters to ebm-papst This launch is a competitive and market signal in the data centre power chain rather than a direct fan or motor product. Vertiv is pushing critical power equipment outdoors and to the medium-voltage utility interface, which changes the thermal management envelope for outdoor enclosures and the airflow/cooling requirements around UPS and battery skids. Assessment (inference): Outdoor-rated MV power platforms with long-duration battery backup could create incremental demand for ruggedised, high-IP-rated fan and cooling solutions in enclosures that ebm-papst does not currently address with standard data hall products. Assessment (inference): The explicit targeting of AI power smoothing and 800 VDC architectures signals that Vertiv is aligning its roadmap with next-generation AI data centre power topologies; ebm-papst should track whether 800 VDC distribution shifts cooling loads toward higher-density, liquid-assisted or hybrid architectures where fan content per rack may change. Assessment (inference): Vertiv's Bologna medium-voltage laboratory and customer demonstration programme strengthen its position as a system-level integrator, potentially narrowing the window for component suppliers to engage directly with hyperscale and neocloud customers on power-adjacent cooling design. ebm-papst's opportunity lies in positioning fan and motor solutions as part of validated outdoor power skid designs and in engaging early with colocation and neocloud operators who value space savings and grid-friendly operation.

原文全文

Vertiv has launched the PowerNexus MV UPS for data centres, targeting colocation, neocloud and hyperscale operators. The outdoor-rated medium-voltage platform combines an uninterruptible power supply, fault ride-through and AI power smoothing in a single system. Designed to sit at the utility connection point, it is intended to provide continuous power protection while keeping indoor space free for computing equipment. The launch reflects growing pressure on data centre operators to secure grid connections, manage fluctuating power demands from AI workloads and use building space more efficiently. Vertiv says the system can deliver up to 98.5% peak operating efficiency and, when paired with long-duration battery systems, support battery-backed operation for up to four hours. According to Vertiv, that setup could reduce the role of diesel generators in long-duration backup. Its skid-based design also moves critical power equipment outside the data hall, helping operators preserve indoor floor space for revenue-generating compute. The system is designed to deliver Class 1 output voltage quality in line with IEC 62040-3, while protecting critical loads during grid disturbances and upstream faults. Vertiv says the platform can also absorb rapid AI load fluctuations before they reach the grid and support grid stability during fault conditions. Vertiv is also offering a Power Systems Computer Aided Design model for the system. It is intended to let customers simulate system behaviour, validate integration, and assess power quality and dynamic interactions with the wider grid before deployment. Kyle Keeper, Senior Vice President of the Power Management Business Unit at Vertiv, set out the backdrop to the launch. "Data centres are facing new infrastructure challenges, including grid queues that can delay deployment and revenue generation, indoor space constraints that limit compute density, and evolving grid requirements that can challenge traditional infrastructure and architectural approaches," said Kyle Keeper, Senior Vice President of the Power Management Business Unit at Vertiv. "The Vertiv PowerNexus MV UPS is designed as a system-level response to those challenges, combining medium-voltage power protection, fault ride-through and AI power smoothing in an outdoor platform designed to operate with long-duration energy storage, helping operators to focus on deploying compute, not coordinating infrastructure." Customer testing Vertiv recently carried out proof-of-concept demonstrations with QTS, SoftBank and Rosendin at its Global Power R&D and Customer Experience Centre in Bologna, Italy. The tests covered steady-state and dynamic conditions and, Vertiv says, showed stable performance across loads from 0% to 100%. According to Vertiv, the demonstrations also showed Class 1 voltage accuracy during rapid load changes and ride-through of severe voltage disturbances, including a full voltage sag for 150 milliseconds and a 25% overvoltage lasting five seconds. QTS was among the customers involved in the testing. "Vertiv PowerNexus MV UPS demonstrated the performance and flexibility needed to support demanding AI data centre applications," said Ryan Kuithe, Senior Vice President of Facilities Operations at QTS. "During proof-of-concept testing at Vertiv's Global Power R&D and Customer Experience Centre, we validated the system's ability to maintain stable power through dynamic load changes and voltage disturbances." Research base Alongside the launch, Vertiv highlighted plans for a dedicated medium-voltage laboratory at its large power research and customer centre in Bologna. The facility is intended to support research and development, full-voltage validation, customer demonstrations, service training and system-level testing for medium-voltage power architectures, including MV UPS, MV to 800 VDC and battery energy storage technologies. Vertiv says customer interest in demonstrations has underlined the need for more dedicated medium-voltage testing space. The planned laboratory forms part of a broader effort to expand its work on power systems for AI-scale data centres. "By enabling full-voltage research and development, testing, customer demonstrations, and system-level validation, the facility will help customers evaluate new architectures with greater confidence as they plan the power systems required for AI-scale data centres, including 800 VDC," said Giovanni Zanei, Vice President of Large Power Conversion at Vertiv.