What happened Hiwave announced that it will host a dedicated session at the 2026 CDCC Data Center Standards Forum, to be held on 19 November 2026 at the China National Convention Center in Beijing. The session, themed "Driving Change into Practice, Full-Chain Intelligent Cooling," is titled "Hiwave AIDC Full-Chain Solution Practice" and focuses on the system-level value and technology evolution of primary-side cooling sources (the heat-rejection side of the cooling plant). In its announcement, Hiwave argues that as AI, large models and high-performance computing push data centers toward higher density, higher power and larger scale, chip power continues to rise and liquid cooling is moving from an optional measure in some scenarios to an important heat-removal path for high-density compute. This shifts the role of the cooling source: previously treated as ancillary equipment supplying cooling capacity, it must now accommodate iterative compute architectures, dynamic load changes, regional resource conditions and future scale-out. Hiwave proposes a "four-dimension collaborative decision" framework covering IT, cooling capacity, architecture and geography. Under the IT dimension, cooling configuration is driven by chip power density, server architecture, rack configuration and future compute upgrades rather than single-device parameters. Under cooling capacity, the company advocates matching capacity and modulation capability to dynamic rather than fixed peak loads. Under architecture, it proposes decoupling cooling-source, distribution and terminal boundaries, combined with an air-liquid common-source architecture that supports both air and liquid cooling terminals, plus modular design and phased deployment. Under geography, it calls for differentiated configuration based on local climate, natural cooling resources, water availability and building conditions. Hiwave frames three core design principles: decoupling to address chip uncertainty, air-liquid common-source for flexible allocation and phased deployment, and total cost of ownership optimization across the full lifecycle. The session is scheduled for 13:30 on 19 November in Room 311B. ### Key figures - Event date and time: 19 November 2026, 13:30 - Venue: China National Convention Center, Beijing, Room 311B - Framework dimensions: four (IT, cooling capacity, architecture, geography) - Core design principles: three (decoupling, air-liquid common-source, TCO optimization) - No specific figures disclosed on investment amounts, production capacity, market share or revenue targets. ### Why it matters to ebm-papst Hiwave is positioning itself as a system-level cooling-source integrator for AI data centers, explicitly promoting an air-liquid common-source architecture that must remain compatible with both air-cooled and liquid-cooled terminals. For ebm-papst, this is a market signal that Chinese AIDC cooling suppliers are moving up the value chain from component supply to system architecture definition, which could shape specification requirements for fans and air-moving components in hybrid air-liquid cooling designs. Assessment (inference): Hiwave's emphasis on decoupling and phased deployment implies that air-cooled terminals will coexist with liquid cooling for multiple technology generations, sustaining demand for high-efficiency EC fans and fan arrays in retrofit and incremental build scenarios. Assessment (inference): if Hiwave's four-dimension framework gains traction in Chinese data center standards discussions, it may influence procurement criteria toward system-level TCO and modulation capability rather than unit performance, favoring suppliers able to co-engineer with cooling-source integrators. Assessment (inference): ebm-papst should monitor the CDCC forum outcomes and engage with Chinese AIDC cooling integrators to ensure its fan and motor platforms are specified within air-liquid common-source architectures.
原文全文
原文
英文翻译
算力持续跃迁,能源系统如何与之协同?
随着人工智能、大模型及高性能计算快速发展,数据中心正加速迈向高密度、高功率、规模化的新阶段。芯片功率持续攀升,液冷技术从部分场景的可选方案逐渐成为高密度算力的重要散热路径,数据中心的热管理体系也随之发生深刻变革。
当液冷逐渐成为高密算力的重要技术选择,冷源系统的角色也在发生变化。
过去,冷源更多被视为数据中心制冷系统的配套设备,主要承担提供冷量的基础功能;而在下一代AIDC中,冷源不仅要满足当前芯片与服务器的散热需求,还需要适应算力架构迭代、负荷动态变化、不同地域资源条件以及未来规模扩展。
从单一设备选型到系统级协同决策,冷源正在从被动配套走向算力基础设施的核心底座。
冷源选型不再是单一设备采购,而是IT、冷量、架构、地域四维协同的系统工程。
11月19日,2026 CDCC数据中心标准论坛大会将在北京国家会议中心举行。海悟将以「驭变向实 全链智冷」为主题,举办海悟AIDC全链路解决方案实践专场,围绕一次侧冷源的系统价值与技术演进,分享如何通过四维协同决策、风液同源架构与系统解耦设计,构建可扩展、可验证、可规模化的算力冷源基础设施,为下一代绿色智算中心建设提供确定性支撑。
一、从被动配套到核心底座,重新定义AIDC冷源价值
AI算力的发展,正在改变数据中心的能源与热管理需求。
随着GPU等高性能芯片持续迭代,单柜功率密度不断提升,液冷系统逐步进入规模化应用阶段。与传统风冷架构相比,液冷系统对冷源供给、温度控制、流量调节及系统协同提出了更高要求。
与此同时,不同代际的芯片、不同类型的服务器,以及不同规模的算力集群,对冷量需求和运行条件也存在差异。
这意味着,冷源系统不能再简单按照当前IT设备的制冷需求进行一次性配置,而需要具备适应未来算力变化的能力。
一方面,冷源需要与IT架构协同设计,满足不同技术代际的散热需求;另一方面,还要兼顾冷量动态变化、系统扩展、建设条件及长期运营成本。
尤其在绿色低碳发展背景下,冷源系统不仅关系到数据中心的制冷能力,也直接影响能源利用效率、水资源配置和基础设施全生命周期成本。
因此,AIDC冷源的价值正在从单纯提供冷量,转向支撑算力稳定运行、能源高效利用与基础设施持续演进。
海悟以系统工程思维重新审视一次侧冷源的定位,推动冷源从传统制冷配套设备升级为连接算力需求、热管理系统与能源利用的核心基础设施。
二、IT、冷量、架构、地域:四维协同构建确定性冷源方案
面对IT架构多变、冷量需求跳变、建筑条件各异及南北气候差异等复杂因素,单一维度的设备选型已经难以满足下一代智算中心的建设需求。
海悟提出以IT、冷量、架构、地域四大维度协同决策,从项目实际需求出发,构建更加精准、灵活、可持续的冷源系统。
01 IT维度|以算力需求定义冷源配置
IT架构是冷源系统设计的起点。
不同芯片代际、服务器配置及机柜功率密度,对散热方式、供液条件和系统运行能力提出不同要求。
随着液冷技术持续发展,数据中心逐渐从传统风冷末端向风液融合、多类型液冷架构演进。
海悟以IT设备实际需求为基础,将芯片功率密度、服务器架构、机柜配置及未来算力升级纳入冷源规划,推动冷源系统与IT架构协同设计。
不以单一设备参数定义冷源,而以算力需求驱动系统配置,让冷源能力与算力发展相匹配。
02 冷量维度|以动态需求实现精准供冷
算力负载并非始终保持恒定,不同业务类型、运行阶段及设备配置,都可能带来冷量需求变化。
如果冷源系统只按照单一峰值负荷进行固定配置,可能造成部分时段设备利用不足,也可能在负荷变化时面临调节能力不足的问题。
海悟从实际冷量需求出发,综合考虑系统负荷特征、运行变化与未来扩展需求,通过合理配置冷源容量与调节能力,提升系统对动态负荷的适应性。
让冷量供给与算力负荷相匹配,在满足散热需求的同时,兼顾系统运行效率与长期运营成本。
03 架构维度|以系统解耦应对技术代际不确定性
AI芯片迭代速度不断加快,而数据中心基础设施具有较长的使用周期。
如果冷源系统与某一代IT设备过度绑定,当芯片功率、服务器架构或液冷技术路线发生变化时,可能面临系统整体调整甚至重复建设的压力。
海悟以解耦思维应对算力架构的不确定性,通过合理划分冷源侧、输配侧与末端侧的系统边界,推动冷源架构与IT设备配置形成相对独立、灵活适配的协同关系。
同时,依托风液同源架构,兼容不同类型的风冷与液冷末端,实现不同散热需求之间的弹性调配。
结合模块化设计与分期部署,让冷源系统能够根据项目建设节奏和算力发展阶段灵活扩展,减少基础设施整体重构的压力。
04 地域维度|因地制宜优化能源与冷源配置
数据中心的建设条件不仅取决于IT需求,还受到地域气候、自然冷源、水资源禀赋及建筑条件等因素影响。
北方与南方在室外气象条件方面存在差异,不同地区的水资源条件、能源供应情况及项目建设环境也各不相同。
因此,冷源系统不能简单复制单一技术路线,而应结合项目所在地的实际条件进行差异化配置。
海悟坚持因地制宜,根据不同地域的气候特征、水资源条件及项目需求,综合考虑冷源形式、系统架构与运行策略,提升自然资源利用效率与系统适配能力。
让冷源方案既符合项目当前建设条件,也兼顾长期运营效率与绿色低碳发展需求。
IT定义需求,冷量决定能力,架构保障演进,地域决定适配。
四维协同,让冷源选型从单一设备采购走向系统级决策,为AIDC基础设施建设提供更加确定的技术路径。
三、以确定性方案,回应算力冷源的未来挑战
面对算力技术快速迭代与数据中心建设规模持续扩大,冷源系统需要解决的不仅是当前散热问题,更是未来长期运行与持续演进的问题。
海悟围绕这一目标,形成三大核心设计思路:
以解耦思维应对芯片不确定性。
通过冷源与IT架构合理解耦,降低基础设施对单一技术代际的依赖,让系统具备更好的适配与演进能力。
以风液同源实现弹性调配与分期部署。
兼容风冷与液冷末端,根据不同算力规模、设备配置及建设阶段灵活组织冷却系统,提升架构适配能力与部署灵活性。
以TCO最优为准则,统筹全生命周期价值。
冷源决策不只关注初始设备投资,更要综合考虑建设成本、能源消耗、运行维护及未来扩展升级成本,通过系统级优化实现长期价值。
最终,让一次侧冷源成为可扩展、可验证、可规模化的确定性基础设施。
四、以绿色冷源支撑算力发展,推动数字基础设施可持续演进
算力规模持续增长,数字基础设施建设也面临能源效率、资源利用与长期运营的多重挑战。
冷源作为数据中心能源与热管理体系的重要组成部分,其技术路线与系统配置,不仅关系到算力运行的稳定性,也影响着数据中心的能源利用效率与长期运营成本。
从传统冷源配套到系统级协同,从单一制冷配置到风液融合,从一次性建设到分期扩展,冷源系统的升级正在推动数据中心基础设施向更加集约、高效、灵活的方向发展。
通过四维协同决策、系统解耦与风液同源架构,海悟持续探索适应不同算力场景、不同地域条件与不同技术代际的冷源解决方案。
以更加精准的冷源配置减少资源错配,以更加灵活的系统架构适应算力演进,以全生命周期成本管理推动能源高效利用。
这不仅是冷却技术的升级,更是数字基础设施建设理念的转变。
未来,海悟将继续深化全链路制冷技术创新与系统解决方案能力,以可靠、高效、灵活的冷源基础设施,助力绿色算力建设,推动数字经济与能源体系协同发展。
让冷源成为算力发展的坚实底座,让每一份能源创造更高价值。
11月19日,2026 CDCC数据中心标准论坛大会,海悟将围绕一次侧冷源四维协同实践,与行业伙伴共同探讨冷源从被动配套走向算力核心底座的技术路径。
2026 CDCC数据中心标准论坛大会
驭变向实 · 全链智冷
海悟AIDC全链路解决方案实践专场
主题:从被动配套到核心底座——冷源如何四维协同?
时间:2026年11月19日 13:30
地点:北京·国家会议中心 311B厅
冷源如何适配算力变化?如何实现系统协同与长期价值优化?
海悟诚邀行业伙伴莅临交流,共探AIDC冷源技术创新与绿色算力发展新路径,共筑高效、可靠、可持续的数字基础设施新未来。
Strengthening the computing-power energy foundation for data center heat dissipation and temperature control, building a new paradigm of four-dimension collaboration for data center cooling sources | Hiwave appears at the 2026 CDCC Data Center Standards Forum
As computing power continues to leap forward, how can energy systems keep pace?
With the rapid development of artificial intelligence, large models and high-performance computing, data centers are accelerating toward a new stage of high density, high power and large scale. Chip power continues to climb, liquid cooling technology is gradually moving from an optional solution in some scenarios to an important heat dissipation path for high-density computing power, and the thermal management system of data centers is undergoing profound change accordingly.
As liquid cooling gradually becomes an important technology choice for high-density computing power, the role of the cooling source system is also changing.
In the past, the cooling source was more regarded as supporting equipment for the data center cooling system, mainly undertaking the basic function of providing cooling capacity; in next-generation AIDC, the cooling source must not only meet the current heat dissipation needs of chips and servers, but also adapt to computing architecture iteration, dynamic load changes, resource conditions in different regions and future scale expansion.
From single equipment selection to system-level collaborative decision-making, the cooling source is moving from passive supporting equipment to the core foundation of computing infrastructure.
Cooling source selection is no longer a single equipment purchase, but a system engineering of four-dimension collaboration among IT, cooling capacity, architecture and geography.
On November 19, the 2026 CDCC Data Center Standards Forum will be held at the China National Convention Center in Beijing. Hiwave will hold the Hiwave AIDC Full-Chain Solution Practice session under the theme "Driving Change into Practice, Full-Chain Intelligent Cooling," focusing on the system value and technology evolution of the primary-side cooling source, and sharing how to build scalable, verifiable and scalable computing-power cooling source infrastructure through four-dimension collaborative decision-making, air-liquid common-source architecture and system decoupling design, providing deterministic support for the construction of next-generation green intelligent computing centers.
I. From passive supporting equipment to core foundation, redefining the value of AIDC cooling sources
The development of AI computing power is changing the energy and thermal management needs of data centers.
As high-performance chips such as GPUs continue to iterate, the power density of a single rack continues to increase, and liquid cooling systems are gradually entering the stage of large-scale application. Compared with traditional air-cooling architectures, liquid cooling systems place higher requirements on cooling source supply, temperature control, flow regulation and system collaboration.
At the same time, chips of different generations, different types of servers and computing clusters of different scales also have differences in cooling capacity demand and operating conditions.
This means that the cooling source system can no longer simply be configured once according to the cooling needs of current IT equipment, but needs to have the ability to adapt to future changes in computing power.
On the one hand, the cooling source needs to be designed in collaboration with the IT architecture to meet the heat dissipation needs of different technology generations; on the other hand, it must also take into account dynamic changes in cooling capacity, system expansion, construction conditions and long-term operating costs.
Especially in the context of green and low-carbon development, the cooling source system is not only related to the cooling capacity of the data center, but also directly affects energy utilization efficiency, water resource allocation and the full life-cycle cost of infrastructure.
Therefore, the value of the AIDC cooling source is shifting from simply providing cooling capacity to supporting stable operation of computing power, efficient energy utilization and continuous evolution of infrastructure.
Hiwave re-examines the positioning of the primary-side cooling source with system engineering thinking, promoting the cooling source to upgrade from traditional cooling supporting equipment to core infrastructure connecting computing power demand, thermal management systems and energy utilization.
II. IT, cooling capacity, architecture, geography: four-dimension collaboration to build deterministic cooling source solutions
Facing complex factors such as variable IT architectures, jumping cooling capacity demand, different building conditions and climate differences between north and south, single-dimension equipment selection can no longer meet the construction needs of next-generation intelligent computing centers.
Hiwave proposes collaborative decision-making across the four dimensions of IT, cooling capacity, architecture and geography, starting from the actual needs of the project to build a more precise, flexible and sustainable cooling source system.
01 IT dimension | Defining cooling source configuration by computing power demand
IT architecture is the starting point for cooling source system design.
Different chip generations, server configurations and rack power densities place different requirements on heat dissipation methods, liquid supply conditions and system operating capabilities.
As liquid cooling technology continues to develop, data centers are gradually evolving from traditional air-cooled terminals to air-liquid fusion and multi-type liquid cooling architectures.
Based on the actual needs of IT equipment, Hiwave incorporates chip power density, server architecture, rack configuration and future computing power upgrades into cooling source planning, promoting collaborative design of the cooling source system and IT architecture.
Rather than defining the cooling source by single equipment parameters, it drives system configuration by computing power demand, so that cooling source capability matches the development of computing power.
02 Cooling capacity dimension | Achieving precise cooling supply based on dynamic demand
Computing loads are not always constant; different business types, operating stages and equipment configurations may all bring changes in cooling capacity demand.
If the cooling source system is only configured in a fixed manner according to a single peak load, it may cause insufficient equipment utilization in some periods, and may also face insufficient regulation capability when the load changes.
Starting from actual cooling capacity demand, Hiwave comprehensively considers system load characteristics, operational changes and future expansion needs, and improves the system's adaptability to dynamic loads by reasonably configuring cooling source capacity and regulation capability.
Let cooling capacity supply match computing power load, while meeting heat dissipation needs, taking into account system operating efficiency and long-term operating costs.
03 Architecture dimension | Addressing technology generation uncertainty through system decoupling
AI chips are iterating faster and faster, while data center infrastructure has a long service life.
If the cooling source system is overly bound to a certain generation of IT equipment, when chip power, server architecture or liquid cooling technology routes change, it may face pressure for overall system adjustment or even repeated construction.
Hiwave addresses the uncertainty of computing architecture with decoupling thinking, and by reasonably dividing the system boundaries of the cooling source side, transmission and distribution side and terminal side, promotes a relatively independent and flexibly adaptable collaborative relationship between the cooling source architecture and IT equipment configuration.
At the same time, relying on the air-liquid common-source architecture, it is compatible with different types of air-cooled and liquid-cooled terminals, achieving flexible allocation between different heat dissipation needs.
Combined with modular design and phased deployment, the cooling source system can be flexibly expanded according to project construction rhythm and computing power development stages, reducing the pressure of overall infrastructure reconstruction.
04 Geography dimension | Optimizing energy and cooling source configuration according to local conditions
The construction conditions of a data center depend not only on IT needs, but are also affected by factors such as regional climate, natural cooling sources, water resource endowment and building conditions.
The north and south differ in outdoor meteorological conditions, and different regions also differ in water resource conditions, energy supply conditions and project construction environments.
Therefore, the cooling source system cannot simply copy a single technology route, but should be configured differently according to the actual conditions of the project location.
Hiwave adheres to adapting to local conditions, and comprehensively considers cooling source forms, system architecture and operating strategies according to the climate characteristics, water resource conditions and project needs of different regions, improving the efficiency of natural resource utilization and system adaptability.
Let the cooling source solution not only meet the current construction conditions of the project, but also take into account long-term operating efficiency and green low-carbon development needs.
IT defines demand, cooling capacity determines capability, architecture guarantees evolution, geography determines adaptation.
Four-dimension collaboration moves cooling source selection from single equipment procurement to system-level decision-making, providing a more certain technical path for AIDC infrastructure construction.
III. Responding to the future challenges of computing power cooling sources with deterministic solutions
Facing the rapid iteration of computing power technology and the continuous expansion of data center construction scale, the cooling source system needs to solve not only current heat dissipation problems, but also future long-term operation and continuous evolution problems.
Around this goal, Hiwave has formed three core design ideas:
Address chip uncertainty with decoupling thinking.
Through reasonable decoupling of the cooling source and IT architecture, reduce infrastructure dependence on a single technology generation, so that the system has better adaptability and evolution capability.
Achieve flexible allocation and phased deployment with air-liquid common source.
Be compatible with air-cooled and liquid-cooled terminals, flexibly organize the cooling system according to different computing power scales, equipment configurations and construction stages, and improve architecture adaptability and deployment flexibility.
Take optimal TCO as the criterion and coordinate full life-cycle value.
Cooling source decisions should not only focus on initial equipment investment, but also comprehensively consider construction costs, energy consumption, operation and maintenance and future expansion and upgrade costs, achieving long-term value through system-level optimization.
Ultimately, let the primary-side cooling source become scalable, verifiable and scalable deterministic infrastructure.
IV. Supporting computing power development with green cooling sources and promoting sustainable evolution of digital infrastructure
As computing power scale continues to grow, digital infrastructure construction also faces multiple challenges in energy efficiency, resource utilization and long-term operation.
As an important part of the data center energy and thermal management system, the technical route and system configuration of the cooling source are not only related to the stability of computing power operation, but also affect the energy utilization efficiency and long-term operating costs of the data center.
From traditional cooling source supporting equipment to system-level collaboration, from single cooling configuration to air-liquid fusion, from one-time construction to phased expansion, the upgrade of the cooling source system is promoting the development of data center infrastructure in a more intensive, efficient and flexible direction.
Through four-dimension collaborative decision-making, system decoupling and air-liquid common-source architecture, Hiwave continues to explore cooling source solutions adapted to different computing power scenarios, different regional conditions and different technology generations.
Reduce resource mismatch with more precise cooling source configuration, adapt to computing power evolution with a more flexible system architecture, and promote efficient energy utilization with full life-cycle cost management.
This is not only an upgrade of cooling technology, but also a transformation of the concept of digital infrastructure construction.
In the future, Hiwave will continue to deepen full-chain cooling technology innovation and system solution capabilities, and with reliable, efficient and flexible cooling source infrastructure, help green computing power construction and promote the coordinated development of the digital economy and the energy system.
Let the cooling source become a solid foundation for computing power development, and let every unit of energy create higher value.
On November 19, at the 2026 CDCC Data Center Standards Forum, Hiwave will focus on the four-dimension collaboration practice of primary-side cooling sources and discuss with industry partners the technical path for cooling sources to move from passive supporting equipment to the core foundation of computing power.
2026 CDCC Data Center Standards Forum
Driving Change into Practice · Full-Chain Intelligent Cooling
Hiwave AIDC Full-Chain Solution Practice Session
Theme: From passive supporting equipment to core foundation - how can cooling sources collaborate in four dimensions?
Time: November 19, 2026, 13:30
Venue: China National Convention Center, Beijing, Room 311B
How can cooling sources adapt to changes in computing power? How to achieve system collaboration and long-term value optimization?
Hiwave sincerely invites industry partners to visit and exchange, jointly explore the technical innovation of AIDC cooling sources and the development path of green computing power, and jointly build a new future of efficient, reliable and sustainable digital infrastructure.