Vertiv 推出面向下一代 AI 数据中心的高密度远程配电盘 PowerStation 3100 RPP

Vertiv Launches PowerStation 3100 RPP Delivering 600–1,200 A to Enable 100 kW+ AI Racks
聚合·VertivT22026-11-13 · INTL · Vertiv 维谛技术
新品技术发布数据中心/IT散热
▾ 1 条同事件报道

情报详报

该条目尚未深加工(仅精选条目在流水线中生成英文详报)。

Vertiv 发布 PowerStation 3100 RPP,单平台支持 600–1200A、415/480V 四线制,可支撑 100kW+ 机柜,并集成液冷漏液联动跳闸与可调脱扣。该产品强化其 AI 数据中心供配电布局,对 ebm-pa

原文全文

Vertiv Introduces High-Density Remote Power Panel for Next-Generation AI Data Centers The Vertiv™ PowerStation 3100 RPP delivers 600 A to 1,200 A on a single UL-listed platform, enabling 100 kW+ racks without custom engineering These architectures introduce new protection and power-isolation requirements. Delivering 415 V or 480 V power to the rack through four-wire designs can increase available fault current, raising short circuit withstand requirements at the rack level. At the same time, adoption of direct liquid cooling has created a need to isolate power to an individual rack if a coolant leak is detected. Traditional remote power panels were not designed for these demands. "As new GPU generations drive higher rack power demands, customers need distribution infrastructure that supports both current deployments and evolving architectures," said Kyle Keeper, Senior Vice President of Keeper added: "The Purpose-Built for AI Power Architectures Built on a custom busbar architecture with molded case circuit breakers (MCCBs), the Designed for the Realities of High-Density Power Distribution The - Enhanced fault current protection: The system features circuit breakers with higher short-circuit withstand and interrupting ratings to manage increased fault-current exposure in four-wire architectures providing greater design flexibility while reducing the need for additional fault-current mitigation and the risk of equipment damage or service interruption. - Liquid cooling leak isolation: Each branch circuit breaker includes an integrated remote shunt trip, enabling the facility's leak detection system to isolate power to an individual rack the moment a leak is detected, without shutting down adjacent racks or the entire pod. This feature helps contain incidents, preserve uptime and protect AI workload productivity. The shunt trip accessory is embedded within the breaker, adding no additional footprint. - Branch circuit breakers with adjustable trip units: Operators can switch between 60 A, 100 A and 150 A trip-unit ratings within the same circuit breaker frame, providing a future-ready design that allows the system to accommodate changing rack power demands without replacing breakers. - Integrated metering: Provides visibility into power use and quality, while circuit breaker accessory monitoring reports the position and trip status of every circuit in real time. The compact enclosure supports flexible installation in space-constrained environments, with front-only service access and mounting flexibility. Standardized configurations can be replicated across deployments, helping simplify installation, commissioning, and maintenance as data center capacity scales The Vertiv™ PowerStation 3100 RPP is the final power distribution stage before the rack level in For more information about the About Vertiv Holdings Co. (NYSE: VRT) brings together hardware, software, analytics and ongoing services to enable its customers' vital applications to run continuously, perform optimally and grow with their business needs. Vertiv solves the most important challenges facing today's data centers, communication networks and commercial and industrial facilities with a portfolio of power, cooling and IT infrastructure solutions and services that extends from the cloud to the edge of the network. Headquartered in Westerville, Ohio, USA, Vertiv does business in more than 130 countries. For more information, and for the latest news and content from Vertiv, visit Vertiv.com. Forward-looking statements This release contains forward-looking statements within the meaning of the Private Securities Litigation Reform Act of 1995, Section 27 of the Securities Act, and Section 21E of the Securities Exchange Act. These statements are only a prediction. Actual events or results may differ materially from those in the forward-looking statements set forth herein. Readers are referred to Vertiv's filings with the Securities and Exchange Commission, including its most recent Annual Report on Form 10-K and any subsequent Quarterly Reports on Form 10-Q for a discussion of these and other important risk factors concerning Vertiv and its operations. Vertiv is under no obligation to, and expressly disclaims any obligation to, update or alter its forward-looking statements, whether as a result of new information, future events or otherwise. CONTACT [email protected] View original content to download multimedia:https://www.prnewswire.com/news-releases/vertiv-introduces-high-density-remote-power-panel-for-next-generation-ai-data-centers-302938962.html SOURCE Vertiv Holdings Co