What happened Daikin Applied, a member of Daikin Industries, Ltd., announced on November 10, 2026 from Minneapolis the introduction of Reference Architecture D60-W Water-Cooled Chillers with Dry Coolers — a 60-megawatt (MW) cooling blueprint aimed at AI factories built on the NVIDIA DSX AI Factory Platform with NVIDIA Vera Rubin NVL72. The architecture is positioned as a design starting point for data center developers, engineers and operators, linking rack-level cooling, chillers, heat rejection and controls into a single system rather than a set of separately coordinated supplier packages. The design supports a 60 MW IT load across six deployable units. Liquid cooling covers 92% of the load and air cooling the remaining 8%, using two temperature loops: a high-temperature liquid loop feeding the coolant distribution units (CDUs) and a dedicated low-temperature loop serving air-cooling rack containment units. The core equipment is Daikin Applied's oil-free Magnitude WME magnetic bearing centrifugal chillers, with capacities up to 10 MW. Dry coolers carry the load for most of the year in suitable climates, with chillers supporting the hottest days; the system switches between dry, hybrid and full mechanical cooling modes. DDC Solutions S-Series rack containment units (RCUs) capture residual rack heat, and Daikin Applied's iDCM supervisory layer coordinates RCUs, CDUs, chillers and dry coolers as one plant. RideThrough and RapidRestore chiller technologies address power disturbances and restart. The Daikin Applied CDU and data center dry cooler are still under development, with availability targeted for the second half of 2027. ### Key figures - 60 MW IT load capacity per reference architecture - Six deployable units per D60-W design - 92% of load handled by liquid cooling; 8% by air cooling - Chiller capacity up to 10 MW per Magnitude WME unit - Two temperature loops (high-temperature liquid, low-temperature air-cooling) - Three operating modes: dry cooling, hybrid cooling, full mechanical cooling - CDU and data center dry cooler availability targeted for H2 2027 - Daikin Industries named to the 2026 Fortune Global 500 ### Why it matters to ebm-papst This is a direct competitive signal in the AI data center cooling chain. Daikin Applied is packaging chillers, CDUs, dry coolers, rack containment and supervisory controls into a single reference architecture co-aligned with NVIDIA's DSX platform — precisely the layer where fan and air-movement suppliers are usually specified. The 8% air-cooled share and the dry cooler heat rejection path both depend on fans and blowers, and the low-temperature loop serving air-cooling RCUs implies fan-driven heat exchangers inside the rack containment. Assessment (inference): Daikin Applied's move raises the risk that cooling content in NVIDIA-referenced AI factory designs becomes bundled around a single HVAC OEM's portfolio, narrowing the window for independent fan suppliers to be specified at the rack and dry cooler level. Assessment (inference): the H2 2027 target for the in-house CDU and dry cooler suggests Daikin Applied may still need external air-movement components during the ramp, which is a near-term opportunity. Assessment (inference): the emphasis on oil-free standby efficiency, fast restart and low WUE indicates that fan efficiency at part-load and standby conditions will be a differentiating specification in AI factory tenders, favoring suppliers with high-efficiency EC fan platforms and integrated control electronics.
原文全文
Press Releases
Blueprint connects rack cooling, oil-free chillers, dry coolers and controls in one system
MINNEAPOLIS, November 10, 2026 - Daikin Applied today introduced Reference Architecture D60-W Water-Cooled Chillers with Dry Coolers, a 60-megawatt (MW) cooling blueprint for AI factories based on the NVIDIA DSX AI Factory Platform with NVIDIA Vera Rubin NVL72. The architecture gives data center developers, engineers and operators a starting point for designing cooling from rack to ambient, connecting cooling equipment and controls into a single system.
As AI factories scale, cooling plays a growing role in how quickly capacity comes online and how reliably it runs. Planning for it often means coordinating rack requirements, facility equipment, heat rejection systems and controls across multiple teams and suppliers. D60-W brings those elements together in one design, helping customers reduce integration complexity and move more quickly into project engineering.
D60-W supports a 60 MW IT load across six deployable units. Liquid cooling handles 92% of the load and air cooling handles the remaining 8%. The design runs two temperature loops. A high-temperature liquid loop serves the coolant distribution units (CDUs) and a dedicated low-temperature loop serves the air-cooling rack containment units, improving overall plant efficiency.
D60-W is built around Daikin Applied's oil-free Magnitude® WME magnetic bearing centrifugal chillers, with capacities up to 10 MW. In D60-W, dry coolers carry the cooling load for most of the year in suitable climates, with chillers supporting the operation during the hottest days. Large-scale chillers have traditionally relied on oil lubrication, which requires maintenance even during extended periods of standby operation, including oil management and periodic run cycles. Oil-free technology removes oil heaters, pumps and standard oil servicing requirements, reducing standby energy use and maintenance. It also eliminates oil-related startup delays when chillers return from the standby state, helping cooling recover quickly and protecting GPU availability.
“AI factories are designed to turn energy into output as efficiently as possible, and cooling infrastructure sits right at the center of that challenge,” said Yu Nishiwaki, president and CEO of Daikin Applied. “D60-W draws on the full depth of Daikin Applied’s portfolio, giving customers a single partner as they scale AI operations.”
D60-W’s racks are primarily liquid cooled via CDUs, while the DDC Solutions S-Series rack containment units (RCUs) capture the remaining heat at the rack and move it directly to the low-temperature loop, with fire suppression and water-loop protection built into every rack1. Operators can run compute in air-cooled, liquid-cooled or hybrid configurations side by side.
“An AI factory is a system of systems,” said Karim Shalash, director of Data Center Solutions at Daikin Applied. “A cooling decision at the rack carries implications for water temperatures, flow requirements, plant operation and heat rejection. D60-W gives engineering teams a framework for working through those dependencies and developing a cooling architecture around the facility's operating requirements.”
1 Source: DDC Solutions, S-Series Rack Containment Platform specifications. [ddcsolutions.com]
At the equipment level, Daikin Applied's RideThrough® and RapidRestore® chiller technologies address brief power disturbances and restart after shutdown. At the system level, redundancy across the cooling system – from the rack to the dry cooler – helps maintain uptime during equipment outages and planned maintenance.
D60-W switches between dry cooling, hybrid cooling and full mechanical cooling based on outdoor conditions. In dry cooling mode, the chiller compressors are off. In hybrid mode, waterside economizers precool the return water and the chillers handle the remaining load. Heat rejection relies on dry coolers instead of evaporative cooling towers, which eliminates cooling-tower make-up water and supports low water usage effectiveness (WUE).
Within D60-W, Daikin Applied’s iDCM supervisory layer coordinates RCUs, CDUs, chillers and dry coolers as one plant. It manages load sharing, balances equipment operating hours and controls transitions between the three operating modes. Built-in redundancy and integration with site management systems provide greater control resilience and centralized visibility, while energy optimization and predictive maintenance capabilities support plant efficiency and equipment reliability.
Because D60-W scales by deployable unit, project teams can add capacity as demand grows, backed by Daikin Applied commissioning, planned maintenance and 24/7 emergency response. The Daikin Applied CDU and data center dry cooler are currently under development, with availability targeted for the second half of 2027.
To access Reference Architecture D60-W Water-Cooled Chillers with Dry Coolers and discuss its application to a project, visit daikinapplied.com/industry-solutions/data-center-solutions/D60W-ai-factory-reference-architecture/
Daikin Applied, a member of Daikin Industries, Ltd., which was named to the 2026 Fortune Global 500, designs and manufactures advanced commercial and industrial HVAC systems for
customers around the world. The company’s technology and services play a vital role in creating comfortable, efficient and sustainable spaces to work and live — and in delivering quality air to workers, tenants and building owners. Daikin Applied solutions are sold through a global network of dedicated sales, service and parts offices. For more information or to locate a Daikin Applied representative, visit www.daikinapplied.com or call 800-432-1342. Also, follow the company on LinkedIn for the latest on HVAC technology, services and trends.
Find out more in your region.