What happened Hiwave (Chinese thermal-management and digital-energy infrastructure supplier) published a product release on 10 November 2026 introducing its immersion liquid-cooling cabinet, aimed at AI intelligent-computing centers, high-performance computing (HPC) and operator/cloud data centers. The unit is a fully integrated immersion system: an immersion tank, liquid-to-liquid heat exchanger, circulation pump and coolant are combined in a single package, cooling servers and switches by direct immersion in dielectric coolant. Heat from the IT load is carried away by the secondary-side coolant and transferred in the heat exchanger to the facility's primary-side chilled water; the cabinet connects directly to existing primary supply/return water and cooling-tower systems, which Hiwave says reduces system-integration complexity. The release is organized around five themes: (1) full-immersion cooling architecture; (2) precision temperature control using variable-frequency circulation pumps and intelligent control algorithms that modulate flow to match IT load; (3) full-chain safety monitoring covering wetted-material compatibility, direct and indirect leak detection, optional coolant-quality sensing with alarm thresholds, and power-loss memory plus auto-restart on power recovery; (4) intelligent control with PID algorithms on key components, Modbus communications for remote monitoring and command dispatch into a data-center management platform, and an optional smart electricity meter for energy analysis; and (5) target applications spanning AI training/inference, telecom data centers and large-scale cloud computing clusters. Hiwave frames the product as part of a broader push into liquid cooling and digital-energy infrastructure for high-density computing. ### Key figures - Secondary-side supply-liquid temperature fluctuation: ≤ ±0.5 °C - Secondary-side supply/return pressure differential fluctuation: ≤ ±0.1 bar - Heat-transfer (cooling capacity) turndown range: 10%–100% - Circulation pump: variable-frequency, load-based speed control - Communications: Modbus protocol support; optional smart meter - No pricing, production capacity, shipment volumes, market-share targets or customer names disclosed. ### Why it matters to ebm-papst This is a direct signal that the Chinese data-center thermal chain is building out immersion liquid-cooling portfolios for AI/HPC densities, where air movement is reduced or eliminated at the IT rack. For ebm-papst, the relevant exposure is the air-side and hybrid segment: CDUs, dry coolers, adiabatic/fluid coolers and the fans inside them, plus air-cooled and rear-door heat-exchanger rooms that remain the majority of installed capacity. A domestic supplier offering a fully integrated immersion cabinet with pump, heat exchanger and controls increases price and integration pressure on conventional precision-air-conditioning and fan-based cooling architectures in Chinese AI projects. Assessment (inference): Hiwave's move is more a market signal than an immediate competitive threat to ebm-papst's core fan business, since immersion cabinets displace rack-level air movers rather than fans in chillers or cooling towers. The nearer opportunity is on the heat-rejection side — immersion deployments still require primary-side cooling water, dry coolers and cooling towers, all fan-intensive — and on hybrid facilities where air cooling persists for storage, networking and lower-density racks. Assessment (inference): ebm-papst should track whether Hiwave bundles third-party heat-rejection equipment, since that determines whether the company becomes a channel partner for EC fans or a competitor pushing integrated thermal skids. Assessment (inference): the ±0.5 °C and 10%–100% turndown specifications suggest Chinese buyers now benchmark liquid cooling on control precision and part-load efficiency, the same metrics driving EC-fan adoption in air-side systems; ebm-papst's message should link fan efficiency and controllability to overall facility part-load performance.
原文全文
原文
英文翻译
人工智能与高性能计算加速发展,算力基础设施正迈向更高功率密度、更大规模集群的新阶段。随着芯片性能持续提升,传统风冷技术面临散热能力、空间利用及能效优化等多重挑战,液冷技术正成为新一代数据中心热管理的重要发展方向。
其中,浸没式液冷通过将服务器等IT设备直接浸入绝缘冷却液中,实现设备热量的高效传递,为高密度算力提供新的散热路径。
面向AI智算中心及高性能计算场景,海悟浸没式液冷机柜以一体化集成设计为基础,融合高效换热、精准温控、全链路安全监测与智能控制技术,为高密度IT设备提供稳定、可靠、智能的液冷散热保障。
01 全浸没散热|构建高效冷却架构
面对高密度服务器持续增长的散热需求,传统空气冷却方式在热量传递效率及散热能力方面面临更高要求。
海悟一体式浸没液冷系统采用高度集成化设计,将浸没Tank、液液热交换器、循环泵及冷却液集成于一体,实现服务器、交换机等IT设备的浸没式循环冷却。
系统通过二次侧冷却液直接带走IT设备运行产生的热量,再经液液热交换器与一次侧冷却水进行热量交换,实现IT设备与外部冷源之间的高效热量传递。
通过直接外接数据中心一次侧供回水及冷却塔系统,即可构建完整的液冷散热链路,减少系统集成复杂度,为高密度算力设备提供稳定的冷却支持。
从IT设备到循环冷却,再到外部冷源,高度集成的系统架构让散热更直接、更高效。
02 精准温控|让每一度都恰到好处
液冷系统不仅需要具备高效换热能力,更需要在复杂负载变化下保持稳定的温度控制。
海悟浸没式液冷机柜采用智能精准温控技术,通过变频循环泵与智能控制算法,根据IT设备实际负载动态调节循环流量,实现冷却能力与散热需求的精准匹配。
-
精准温控: 二次侧供液温度波动≤±0.5℃,保障IT设备冷却环境稳定。
-
稳定压差: 二次侧供回液压差波动≤±0.1bar,提升系统运行稳定性。
-
宽幅调节: 换热量支持10%~100%范围调节,灵活适应不同负载需求。
-
变频运行: 循环泵根据系统负载智能调节转速,优化运行能耗。
-
自然冷却: 支持与自然冷却系统联动,充分利用低温环境下的自然冷源。
同时,系统具备智能防凝露功能,可实时监测机房露点温度,动态调整温控目标,提升不同环境条件下的运行适应能力。
让温度控制更精准,让冷却能力随算力负载灵活响应。
03 全链路监测|筑牢液冷运行安全防线
液冷系统的长期稳定运行,离不开对材料、冷却介质及循环链路的全面管理。
海悟浸没式液冷机柜从材料兼容性、泄漏监测到冷却液质量管理,构建多层次安全保障机制。
-
材料兼容: 湿材料经过专用严格检测,确保与冷却工质具备良好的兼容性。
-
漏液监测: 支持直接及间接全链路漏液检测,及时发现异常风险。
-
工质管理: 可选配冷却液质量检测组件,实时监测工质状态,超限报警。
-
运行保障: 支持断电记忆与来电自启动功能,提升系统运行连续性。
通过多维度状态监测与异常预警,将安全管理贯穿液冷系统运行全过程,为IT设备长期稳定运行提供保障。
04 智能控制|让液冷运维更高效
随着数据中心规模不断扩大,设备数量与系统复杂度持续提升,传统人工巡检和分散管理模式已难以满足智能化运维需求。
海悟浸没式液冷机柜搭载智能控制系统,关键器件采用PID控制算法,结合IT负载变化,动态调节系统运行参数,实现冷却系统的智能化管理。
系统支持Modbus通信协议,可实现运行数据远程监控与控制命令下发,便于接入数据中心统一管理平台。
同时,可选配智能电表,实现设备用电数据监测,为能耗分析、运行优化及绿色数据中心建设提供数据支撑。
从本地精准控制到远程集中管理,让液冷系统运行状态可视、可控、可管理。
05 多元应用|适配高密算力基础设施
依托一体化集成、高效换热、精准温控及智能运维等优势,海悟浸没式液冷机柜可面向多种高密度算力场景提供液冷散热支持。
-
人工智能智算中心: 满足AI训练、推理等高密度算力设备的散热需求。
-
运营商数据中心: 适配通信算力基础设施升级及高性能计算场景。
-
云计算与算力中心: 为规模化算力集群提供稳定、可靠的液冷运行保障。
以液冷之力,释放算力潜能
从全浸没式高效散热,到宽幅调节的精准温控;从全链路安全监测,到远程智能化运维,海悟浸没式液冷机柜以系统级集成能力,推动数据中心冷却技术向高效化、智能化、可靠化持续演进。
面向AI算力时代,海悟将持续深耕液冷技术与数字能源基础设施,以更专业的热管理解决方案,为高密算力释放提供稳定支撑。
Data-center air-conditioning thermal control, fully immersed heat dissipation, intelligently controlling every degree | Hiwave immersion liquid-cooling cabinet
With the accelerated development of artificial intelligence and high-performance computing, computing infrastructure is moving into a new stage of higher power density and larger-scale clusters. As chip performance continues to improve, traditional air-cooling technology faces multiple challenges in cooling capability, space utilization and energy-efficiency optimization, and liquid-cooling technology is becoming an important development direction for next-generation data-center thermal management.
Among these, immersion liquid cooling achieves efficient transfer of equipment heat by directly immersing IT equipment such as servers in insulating coolant, providing a new heat-dissipation path for high-density computing.
Targeting AI intelligent-computing centers and high-performance computing scenarios, the Hiwave immersion liquid-cooling cabinet is based on an integrated design and combines efficient heat exchange, precise temperature control, full-link safety monitoring and intelligent control technology to provide stable, reliable and intelligent liquid-cooling heat-dissipation assurance for high-density IT equipment.
01 Full immersion heat dissipation | Building an efficient cooling architecture
Facing the continuously growing heat-dissipation demand of high-density servers, traditional air-cooling methods face higher requirements in heat-transfer efficiency and cooling capability.
The Hiwave integrated immersion liquid-cooling system adopts a highly integrated design, integrating the immersion tank, liquid-to-liquid heat exchanger, circulation pump and coolant into one unit, enabling immersion circulating cooling of IT equipment such as servers and switches.
The system directly carries away the heat generated by IT equipment operation through secondary-side coolant, then exchanges heat with primary-side cooling water via the liquid-to-liquid heat exchanger, achieving efficient heat transfer between the IT equipment and the external cold source.
By directly connecting to the data center's primary-side supply and return water and cooling tower system, a complete liquid-cooling heat-dissipation link can be built, reducing system integration complexity and providing stable cooling support for high-density computing equipment.
From IT equipment to circulating cooling, and then to the external cold source, the highly integrated system architecture makes heat dissipation more direct and more efficient.
02 Precise temperature control | Making every degree just right
A liquid-cooling system not only needs efficient heat-exchange capability, but also needs to maintain stable temperature control under complex load variations.
The Hiwave immersion liquid-cooling cabinet adopts intelligent precise temperature-control technology, using variable-frequency circulation pumps and intelligent control algorithms to dynamically adjust circulation flow according to the actual load of IT equipment, achieving precise matching of cooling capability and heat-dissipation demand.
- Precise temperature control: Secondary-side supply-liquid temperature fluctuation ≤ ±0.5 °C, ensuring a stable cooling environment for IT equipment.
- Stable pressure differential: Secondary-side supply/return pressure differential fluctuation ≤ ±0.1 bar, improving system operation stability.
- Wide-range adjustment: Heat exchange supports 10%–100% range adjustment, flexibly adapting to different load demands.
- Variable-frequency operation: The circulation pump intelligently adjusts speed according to system load, optimizing operating energy consumption.
- Natural cooling: Supports linkage with natural cooling systems, making full use of natural cold sources in low-temperature environments.
At the same time, the system has an intelligent anti-condensation function, which can monitor the dew-point temperature of the equipment room in real time and dynamically adjust the temperature-control target, improving operational adaptability under different environmental conditions.
Make temperature control more precise, and let cooling capability respond flexibly to computing load.
03 Full-link monitoring | Building a solid defense line for liquid-cooling operation safety
The long-term stable operation of a liquid-cooling system cannot be separated from comprehensive management of materials, cooling media and the circulation link.
The Hiwave immersion liquid-cooling cabinet builds a multi-level safety assurance mechanism covering material compatibility, leak monitoring and coolant quality management.
- Material compatibility: Wetted materials undergo dedicated strict testing to ensure good compatibility with the cooling working fluid.
- Leak monitoring: Supports direct and indirect full-link leak detection to promptly identify abnormal risks.
- Working-fluid management: An optional coolant quality detection component can monitor working-fluid status in real time and alarm when limits are exceeded.
- Operation assurance: Supports power-off memory and auto-start on power recovery, improving system operation continuity.
Through multi-dimensional status monitoring and abnormal-condition warning, safety management runs through the entire liquid-cooling system operation process, providing assurance for the long-term stable operation of IT equipment.
04 Intelligent control | Making liquid-cooling O&M more efficient
As data-center scale continues to expand and equipment counts and system complexity continue to rise, traditional manual inspection and decentralized management models can no longer meet intelligent O&M needs.
The Hiwave immersion liquid-cooling cabinet is equipped with an intelligent control system; key components adopt PID control algorithms and, combined with IT load changes, dynamically adjust system operating parameters to achieve intelligent management of the cooling system.
The system supports the Modbus communication protocol, enabling remote monitoring of operating data and issuance of control commands, facilitating integration into a unified data-center management platform.
At the same time, an optional smart electricity meter enables monitoring of equipment power-consumption data, providing data support for energy-consumption analysis, operation optimization and green data-center construction.
From local precise control to remote centralized management, the liquid-cooling system's operating status is made visible, controllable and manageable.
05 Diverse applications | Adapting to high-density computing infrastructure
Relying on advantages such as integrated design, efficient heat exchange, precise temperature control and intelligent O&M, the Hiwave immersion liquid-cooling cabinet can provide liquid-cooling heat-dissipation support for a variety of high-density computing scenarios.
- AI intelligent-computing centers: Meeting the heat-dissipation needs of high-density computing equipment such as AI training and inference.
- Operator data centers: Adapting to communication computing infrastructure upgrades and high-performance computing scenarios.
- Cloud computing and computing centers: Providing stable and reliable liquid-cooling operation assurance for large-scale computing clusters.
Unleash computing potential with the power of liquid cooling
From full-immersion efficient heat dissipation to wide-range precise temperature control; from full-link safety monitoring to remote intelligent O&M, the Hiwave immersion liquid-cooling cabinet, with system-level integration capability, drives data-center cooling technology to continue evolving toward high efficiency, intelligence and reliability.
Facing the AI computing era, Hiwave will continue to deepen liquid-cooling technology and digital-energy infrastructure, providing stable support for the release of high-density computing with more professional thermal-management solutions.