海悟将亮相2026 CDCC数据中心标准论坛,发布AIDC全链路液冷解决方案
情报详报
What happened Hiwave announced that it will present at the 2026 CDCC Data Center Standards Forum, scheduled for 19 November 2026 at the China National Convention Center in Beijing. At the event the company will host a dedicated session titled "Hiwave AIDC Full-Chain Solution Practice" under the theme "Driving Change Toward Practice, Full-Chain Intelligent Cooling." The session is positioned around full-stack liquid cooling, full-lifecycle services, intelligent integration and multi-source cooling coordination, aimed at next-generation AI computing centers. Hiwave will also exhibit at booth T6 in Hall 311B, with the session starting at 13:30. The announcement frames the shift of data centers from general-purpose compute hosting toward high-density, large-scale AI infrastructure, and argues that single-equipment, decentralized build models no longer meet requirements for efficiency, reliability and flexible evolution. Hiwave describes its response as a system-engineering approach spanning from cooling source to chip, combining liquid cooling, standardized and prefabricated delivery, and air-liquid fusion with intelligent coordination. The session is structured around four value dimensions — full, chain, intelligent, cooling. "Full" refers to a five-layer closed-loop thermal management system covering primary-side integrated cooling sources, supplementary cooling with dual water/refrigerant sources, secondary-side liquid cooling CDUs and prefabricated piping, liquid-cooled racks, and liquid-cooled micro-modules. "Chain" covers six business stages: consulting and planning, factory prefabrication, installation and commissioning, O&M management, retrofit and upgrade, and long-term asset management. "Intelligent" centers on the HYPERBLOCK 5.0 product system with a "one architecture, six modules" design and a 5 MW typical standard capacity unit. "Cooling" refers to a multi-source cooling matrix with an air-liquid intelligent coordination architecture compatible with both air-cooled and liquid-cooled terminals, applicable to new builds, retrofits, high-density clusters and water-scarce regions. ### Key figures - Event date: 19 November 2026, session starting at 13:30. - Venue: China National Convention Center, Beijing; booth T6, Hall 311B. - HYPERBLOCK 5.0 typical standard capacity unit: 5 MW. - Five-layer closed-loop thermal management architecture; six business stages in the lifecycle service chain; "one architecture, six modules" product framework. - No financial figures, production capacity, market share or order volumes were disclosed. ### Why it matters to ebm-papst Hiwave is positioning itself as a full-chain AIDC cooling solution provider, explicitly combining liquid cooling with air-liquid fusion architectures that remain compatible with air-cooled terminals. That framing keeps air-side heat rejection — fan walls, EC fans, air handling and dry cooler/adiabatic segments — inside the scope of AI data center designs, even as liquid cooling penetration rises. Assessment (inference): Hiwave's push toward standardized, prefabricated 5 MW building blocks and multi-source cooling matrices could accelerate specification cycles in China's AI data center market, where fan and air-movement content per project may shift from room-level CRAC/CRAH toward fan walls, dry coolers and liquid-cooling CDU auxiliary air paths. This represents both a competitive signal — Chinese integrators bundling cooling subsystems and squeezing component suppliers on cost — and a customer opportunity for ebm-papst to position EC fan and air-movement solutions as the air-side enabler of hybrid liquid-air architectures. Assessment (inference): the absence of disclosed volumes or customers means near-term impact cannot be quantified; monitoring Hiwave's HYPERBLOCK 5.0 reference projects and CDU/dry-cooler supplier choices after the forum would be the practical next step.
原文全文
原文
英文翻译
算力驱动数字经济,绿色定义发展未来。
随着人工智能、大模型及数字经济加速发展,算力正成为推动产业变革、赋能社会发展的重要基础资源。数据中心作为数字经济的核心基础设施,正加速向高密度、高能效、规模化和绿色低碳方向演进。
从算力规模持续攀升,到能源利用效率不断优化;从基础设施建设模式升级,到全生命周期运营管理,如何在释放算力价值的同时,实现能源高效利用与产业可持续发展,已成为数字基础设施建设的重要课题。
11月19日,2026 CDCC数据中心标准论坛大会将在北京国家会议中心举行。海悟将以**「驭变向实 全链智冷」**为主题,举办「海悟AIDC全链路解决方案实践专场」,围绕全栈液冷、全链路服务、智能化集成及多元冷源协同,分享面向下一代智算中心的系统解决方案与工程实践,以全链路制冷能力赋能绿色算力基础设施建设。
一、驭变向实,全链智冷:回应下一代算力基础设施发展需求
AI大模型的高速发展,推动数据中心从传统算力承载平台向高密度、规模化的智算基础设施加速演进。
与此同时,高密散热、能源消耗、建设周期及规模化交付等问题日益凸显。传统单一设备、分散式建设模式,已难以充分满足新一代智算中心对高效率、高可靠性与灵活演进的综合需求。
面向这一产业变革,海悟以系统工程思维构建从冷源到芯片的全链路制冷体系,贯通液冷核心环节与项目全生命周期,形成覆盖产品、系统、工程及服务的综合解决方案。
以全栈液冷为技术基础,以标准化、预制化为交付支撑,以风液融合和智能协同为系统能力,推动数据中心制冷从单点设备优化向全链路系统协同升级。
全链路制冷 · 全场景覆盖。
海悟希望以更加高效、可靠、灵活的基础设施解决方案,助力算力资源高效利用,推动数字基础设施向集约化、绿色化、可持续方向发展。
二、聚焦「全·链·智·冷」,构建AIDC全链路解决方案
本次专场,海悟将围绕「全、链、智、冷」四大价值维度,系统呈现面向下一代AI Factory的全链路制冷实践。
全|全栈液冷,构建五层闭环热管理体系
面对万卡级算力集群的高密度散热需求,海悟构建覆盖冷源侧、输配侧与机房末端的五层闭环热管理体系,形成从冷源到芯片的全栈液冷产品支撑。
-
一次侧: 一体化冷源,提供系统级冷量保障。
-
补冷侧: 水氟双冷源,实现多元冷源协同与灵活补冷。
-
二次侧: 液冷CDU与预制化管网,实现冷却液高效输配与精准控制。
-
末端侧: 液冷机柜,满足高密度服务器散热需求。
-
微模块侧: 液冷微模块,推动制冷系统与IT基础设施集成化部署。
通过多层级产品协同,海悟打通从冷源到芯片的关键制冷环节,形成完整的系统级热管理能力。同时,以全生命周期标准化服务为支撑,让智算基础设施建设与运行更加可靠、可控。
链|贯通六大业务环节,覆盖资产全生命周期
数据中心的价值不仅在于建设完成,更在于长期稳定运行与持续创造算力价值。
海悟将服务能力贯穿项目全生命周期,围绕六大业务方向,构建从前期规划到长期运营的全链路服务体系:
咨询规划 → 工厂预制 → 安装调试 → 运维管理 → 改造升级 → 长期资产管理
从前期咨询规划与方案设计,到工厂预制和现场安装调试,再到后期运维管理、系统升级及长期资产管理,海悟推动技术、产品、工程与服务深度融合。
通过标准化服务流程与统一责任主体,实现项目各阶段有效衔接,减少多方协同带来的管理成本,让每一次交付都有据可循,让每一份算力都得到持续经营。
智|HYPERBLOCK 5.0,以标准化与预制化推动规模交付
面对算力需求快速变化、芯片技术持续迭代以及数据中心建设规模不断扩大的趋势,基础设施建设需要兼顾标准化、灵活性与可扩展性。
海悟秉承**「以算力需求定义产品、以标准化构建系统、以预制化实现规模交付」**的核心主张,依托HYPERBLOCK 5.0产品体系,构建「一个架构、六大模块」的系统化产品架构。
以5MW为典型标准容量单元,支持不同算力规模、技术代际及建设场景的灵活适配,推动数据中心机电基础设施从传统工程建造向标准化产品与模块化交付转变。
围绕四大能力方向,实现系统能力升级:
-
产品定义算力化: 以算力需求驱动产品设计,让基础设施适配算力发展。
-
系统构建标准化: 以统一架构实现系统复用,提升方案一致性与可复制性。
-
规模交付预制化: 以工厂制造和预制集成支撑批量交付,提高建设效率。
-
场景适配全景化: 面向多规模、多形态、多代际场景,实现灵活配置与持续演进。
通过标准化架构与预制化交付协同,海悟推动数据中心基础设施建设提速、提质、提效,助力行业向更加集约、高效的建设模式转型。
冷|多元冷源矩阵,构建绿色高效风液协同架构
不同地域的气候条件、水资源禀赋及数据中心建设需求各不相同,单一制冷技术难以覆盖所有应用场景。
海悟构建多元冷源产品矩阵,搭载风液同源智能协同架构,兼容风冷与液冷末端,结合项目实际条件进行系统配置与运行策略优化。
无论是新建智算中心,还是存量数据中心节能改造;无论是高密度液冷算力集群,还是水资源相对紧缺地区的算力基础设施,海悟均可提供差异化的系统制冷方案。
通过自然冷源利用、多冷源协同及风液灵活配置,提升能源利用效率与系统适配能力,在保障算力稳定运行的同时,兼顾节能降耗与资源合理利用。
三、以技术创新驱动绿色发展,让算力与能源协同进化
数字经济的持续发展,离不开高效、可靠、绿色的数字基础设施。
从高密度算力散热到能源高效利用,从模块化建设到全生命周期服务,数据中心产业正在经历一场从技术架构到建设模式的系统性变革。
海悟始终围绕数字能源与清洁能源领域的技术创新和产业需求,持续深化全栈液冷、风液融合、模块化预制及智能化控制等关键能力建设,推动制冷系统与算力基础设施深度协同。
让算力发展更高效,让能源利用更集约,让基础设施建设更绿色、更可持续。
此次亮相2026 CDCC数据中心标准论坛大会,海悟将通过全链路制冷解决方案实践,分享面向下一代智算中心的技术探索与系统能力,与行业伙伴共同探讨数字基础设施绿色低碳发展的新路径。
未来,海悟将继续以技术创新为驱动,以系统解决方案为支撑,以全生命周期服务为保障,助力数字经济基础设施高质量发展,为绿色算力建设与产业可持续发展贡献力量。
2026 CDCC数据中心标准论坛大会
驭变向实 · 全链智冷
海悟AIDC全链路解决方案实践专场
时间:2026年11月19日 13:30
地点:北京·国家会议中心
展位:311B厅 T6展位
诚邀行业伙伴莅临交流,共探绿色算力发展新机遇,共筑数字基础设施新未来!
Building a green computing foundation, empowering sustainable digital economy development | Hiwave to appear at the 2026 CDCC Data Center Standards Forum
Computing power drives the digital economy; green defines the future of development.
With the accelerated development of artificial intelligence, large models and the digital economy, computing power is becoming an important foundational resource driving industrial transformation and empowering social development. As the core infrastructure of the digital economy, data centers are accelerating their evolution toward high density, high energy efficiency, large scale and green, low-carbon operation.
From the continuous rise in computing scale to the ongoing optimization of energy utilization efficiency; from the upgrading of infrastructure construction models to full-lifecycle operation management, how to achieve efficient energy use and sustainable industrial development while unlocking the value of computing power has become an important topic in digital infrastructure construction.
On 19 November, the 2026 CDCC Data Center Standards Forum will be held at the China National Convention Center in Beijing. Hiwave will, under the theme "Driving Change Toward Practice, Full-Chain Intelligent Cooling," host the "Hiwave AIDC Full-Chain Solution Practice Session," sharing system solutions and engineering practices for next-generation intelligent computing centers around full-stack liquid cooling, full-chain services, intelligent integration and multi-source cooling coordination, empowering green computing infrastructure construction with full-chain cooling capability.
I. Driving Change Toward Practice, Full-Chain Intelligent Cooling: Responding to the development needs of next-generation computing infrastructure
The rapid development of AI large models is driving data centers to accelerate their evolution from traditional computing hosting platforms to high-density, large-scale intelligent computing infrastructure.
At the same time, issues such as high-density heat dissipation, energy consumption, construction cycles and large-scale delivery are becoming increasingly prominent. Traditional single-equipment, decentralized construction models can no longer fully meet the comprehensive requirements of new-generation intelligent computing centers for high efficiency, high reliability and flexible evolution.
Facing this industrial transformation, Hiwave builds a full-chain cooling system from cooling source to chip with systems engineering thinking, connecting core liquid cooling links with the full project lifecycle, and forming comprehensive solutions covering products, systems, engineering and services.
With full-stack liquid cooling as the technical foundation, standardized and prefabricated delivery as the support, and air-liquid fusion and intelligent coordination as system capabilities, it drives data center cooling from single-point equipment optimization to full-chain system coordination.
Full-chain cooling · Full-scenario coverage.
Hiwave hopes to use more efficient, reliable and flexible infrastructure solutions to help efficient utilization of computing resources and drive digital infrastructure toward intensive, green and sustainable development.
II. Focusing on "Full, Chain, Intelligent, Cooling" to build AIDC full-chain solutions
At this session, Hiwave will systematically present full-chain cooling practices for the next-generation AI Factory around the four value dimensions of "full, chain, intelligent, cooling."
Full | Full-stack liquid cooling, building a five-layer closed-loop thermal management system
Facing the high-density heat dissipation needs of ten-thousand-card computing clusters, Hiwave builds a five-layer closed-loop thermal management system covering the cooling source side, transmission and distribution side and room terminals, forming full-stack liquid cooling product support from cooling source to chip.
- Primary side: integrated cooling source, providing system-level cooling capacity assurance.
- Supplementary cooling side: dual water/refrigerant cooling sources, enabling multi-source cooling coordination and flexible supplementary cooling.
- Secondary side: liquid cooling CDU and prefabricated piping networks, enabling efficient coolant transmission and precise control.
- Terminal side: liquid-cooled racks, meeting high-density server heat dissipation needs.
- Micro-module side: liquid-cooled micro-modules, promoting integrated deployment of cooling systems and IT infrastructure.
Through multi-level product coordination, Hiwave connects the key cooling links from cooling source to chip, forming complete system-level thermal management capability. At the same time, supported by full-lifecycle standardized services, intelligent computing infrastructure construction and operation become more reliable and controllable.
Chain | Connecting six major business stages, covering the full asset lifecycle
The value of a data center lies not only in completed construction, but also in long-term stable operation and continuous creation of computing value.
Hiwave runs its service capability through the full project lifecycle, building a full-chain service system from early planning to long-term operation around six business directions:
Consulting and planning → Factory prefabrication → Installation and commissioning → O&M management → Retrofit and upgrade → Long-term asset management
From early consulting, planning and solution design, to factory prefabrication and on-site installation and commissioning, and then to later O&M management, system upgrades and long-term asset management, Hiwave drives deep integration of technology, products, engineering and services.
Through standardized service processes and a unified responsible entity, it achieves effective connection between project stages, reduces management costs caused by multi-party coordination, makes every delivery traceable, and ensures every unit of computing power is continuously operated.
Intelligent | HYPERBLOCK 5.0, driving scale delivery through standardization and prefabrication
Facing trends of rapidly changing computing demand, continuous chip technology iteration and ever-expanding data center construction scale, infrastructure construction needs to balance standardization, flexibility and scalability.
Hiwave adheres to the core proposition of "defining products by computing demand, building systems by standardization, and achieving scale delivery by prefabrication," and relies on the HYPERBLOCK 5.0 product system to build a systematic product architecture of "one architecture, six modules."
With 5 MW as a typical standard capacity unit, it supports flexible adaptation to different computing scales, technology generations and construction scenarios, driving data center electromechanical infrastructure from traditional engineering construction to standardized products and modular delivery.
Around four capability directions, it achieves system capability upgrades:
- Computing-driven product definition: driving product design by computing demand, so infrastructure adapts to computing development.
- Standardized system construction: achieving system reuse through a unified architecture, improving solution consistency and replicability.
- Prefabricated scale delivery: supporting batch delivery through factory manufacturing and prefabricated integration, improving construction efficiency.
- Panoramic scenario adaptation: achieving flexible configuration and continuous evolution for multi-scale, multi-form and multi-generation scenarios.
Through the combination of standardized architecture and prefabricated delivery, Hiwave drives faster, better and more efficient data center infrastructure construction, helping the industry transform toward a more intensive and efficient construction model.
Cooling | Multi-source cooling matrix, building a green and efficient air-liquid coordinated architecture
Different regions have different climate conditions, water resource endowments and data center construction needs, and a single cooling technology cannot cover all application scenarios.
Hiwave builds a multi-source cooling product matrix, equipped with an air-liquid same-source intelligent coordination architecture, compatible with air-cooled and liquid-cooled terminals, and optimizes system configuration and operation strategies according to actual project conditions.
Whether for new intelligent computing centers or energy-saving retrofits of existing data centers; whether for high-density liquid-cooled computing clusters or computing infrastructure in regions with relatively scarce water resources, Hiwave can provide differentiated system cooling solutions.
Through utilization of natural cooling sources, multi-source coordination and flexible air-liquid configuration, it improves energy utilization efficiency and system adaptability, while ensuring stable computing operation, balancing energy saving and reasonable resource use.
III. Driving green development through technological innovation, enabling coordinated evolution of computing and energy
The continuous development of the digital economy cannot be separated from efficient, reliable and green digital infrastructure.
From high-density computing heat dissipation to efficient energy utilization, from modular construction to full-lifecycle services, the data center industry is undergoing a systemic transformation from technical architecture to construction models.
Hiwave has always focused on technological innovation and industrial needs in the fields of digital energy and clean energy, continuously deepening key capabilities such as full-stack liquid cooling, air-liquid fusion, modular prefabrication and intelligent control, and driving deep coordination between cooling systems and computing infrastructure.
Making computing development more efficient, energy utilization more intensive, and infrastructure construction greener and more sustainable.
At this appearance at the 2026 CDCC Data Center Standards Forum, Hiwave will share its technological exploration and system capabilities for next-generation intelligent computing centers through full-chain cooling solution practices, and discuss new paths for green and low-carbon development of digital infrastructure with industry partners.
In the future, Hiwave will continue to be driven by technological innovation, supported by system solutions and guaranteed by full-lifecycle services, helping high-quality development of digital economy infrastructure and contributing to green computing construction and sustainable industrial development.
2026 CDCC Data Center Standards Forum
Driving Change Toward Practice · Full-Chain Intelligent Cooling
Hiwave AIDC Full-Chain Solution Practice Session
Time: 19 November 2026, 13:30
Venue: Beijing · China National Convention Center
Booth: Hall 311B, Booth T6
Industry partners are sincerely invited to visit and exchange, explore new opportunities for green computing development, and jointly build a new future for digital infrastructure.