# ebm-papst EC fan data cuts freezer defrost energy from 7.8kWh to 3.4kWh weekly

- Source: Cooling Post (T2)
- Published: 2026-11-05
- Score: 46.8
- Tags: Product launch, Refrigeration
- Companies: ebm-papst
- Original: https://www.coolingpost.com/world-news/using-ec-fans-to-trigger-defrost-on-demand/

## Intelligence brief

### What happened On 5 November 2026, Germany-based fan and motor manufacturer ebm-papst announced it has developed a need-based defrosting technology for refrigeration systems that derives its trigger signal from the operating data of EC fans. The approach targets a well-known inefficiency in refrigeration: fixed defrost intervals, which run defrost cycles on a timer regardless of whether the evaporator is actually iced up, causing unnecessary defrost cycles and avoidable energy use. In ebm-papst's method, operating data from the EC fan is used to assess the icing condition of the evaporator, and a defrost cycle is triggered only when conditions require it. The company says laboratory results and initial field tests confirm the technology's potential. The studies to date were carried out in a deep-freeze application at -18°C. To bring Defrost on Demand to market, ebm-papst says it is currently investigating several integration approaches. One is based on an EVCO cooling unit controller that manages the entire refrigeration cycle and can integrate the functions required for on-demand defrosting. In parallel, the company is examining how its own NEXAIRA Gateway can serve as a digital platform to evaluate operating data and provide additional monitoring and analysis functions. Both approaches are undergoing further development and are being validated through pilot projects, with further pilots planned to confirm the results under different operating conditions. ### Key figures - Deep-freeze test application temperature: -18°C - Weekly energy consumption with time-controlled defrosting: 7.8kWh - Weekly energy consumption with on-demand defrosting: 3.4kWh - Potential savings: more than 49% - Baseline defrost schedule: one fixed defrost cycle every seven hours - Defrost cycles actually required with on-demand control: three to six per week, depending on icing condition - Announcement date: 5 November 2026 - No specific figures disclosed on commercial launch timing, pricing, production volumes or number of pilot sites. ### Why it matters to ebm-papst The announcement positions ebm-papst not merely as a component supplier but as a provider of data-driven refrigeration control functionality, using the EC fan as a sensor node. For a company whose commercial refrigeration customers face rising pressure on energy costs and refrigerant-related regulation, a demonstrated 49%-plus reduction in defrost energy in a deep-freeze case is a concrete, quantifiable sales argument. It also strengthens the case for EC fans over AC alternatives, since the value proposition depends on access to fan operating data. The dual integration strategy is notable: partnering with EVCO on a cooling unit controller extends reach into the refrigeration control layer, while the NEXAIRA Gateway route keeps value capture inside ebm-papst's own digital platform and creates a recurring monitoring and analytics touchpoint with customers. This is a competitive signal for other fan and refrigeration control vendors, and a potential customer opportunity for OEM refrigeration unit builders and supermarket chains looking to cut energy in frozen cases. Assessment (inference): The results rest on a single deep-freeze application at -18°C, and ebm-papst itself flags that further pilots are needed across different operating conditions; savings in medium-temperature or high-humidity formats may differ materially, so the 49% figure should be treated as indicative rather than generalizable until broader field data is published. Assessment (inference): The dependence on EVCO controllers or the NEXAIRA Gateway suggests commercialization will be tied to ecosystem partners and retrofit feasibility, which will shape how quickly the technology reaches installed bases.

## Full text (original)

Using EC fans to trigger defrost on demand
5th November 2026GERMANY: EBM-Papst has developed a technology for need-based defrosting based on operating data from EC fans.
Laboratory results and initial field tests are said to confirm the potential for the technology which solves the problem of fixed defrost intervals in refrigeration systems triggering unnecessary defrost cycles.
The technology uses operating data from the EC fan to assess the icing condition of the evaporator and trigger defrost cycles only when necessary.
Studies conducted to date in a deep-freeze application at -18°C are said to demonstrate the potential of on-demand defrosting. Compared to time-controlled defrosting, weekly energy consumption was reduced from 7.8kWh to 3.4kWh.
Instead of a fixed defrost cycle every seven hours, only three to six defrost cycles per week were required, depending on the icing condition. This results in a potential savings of more than 49%.
Further pilot projects are planned for the future to confirm the results under different operating conditions.
To implement Defrost on Demand, EBM‑Papst is currently investigating various integration approaches. One of these is based on an EVCO cooling unit controller that manages the entire refrigeration cycle and can integrate the functions required for on-demand defrosting. At the same time, the company is examining how its own NEXAIRA Gateway can be used as a digital platform to evaluate operating data and provide additional monitoring and analysis functions.
Both approaches are currently undergoing further development and are being validated through pilot projects.