# Sungrow, TÜV Rheinland and module makers publish two reliability test standards for IGBT modules and PCE units

- Source: News · Sungrow (T2)
- Published: 2026-11-05
- Score: 38.8
- Tags: Policy / standards, ESS
- Companies: Sungrow (300274.SZ)
- Original: https://www.ne21.com/news/show-232168.html

## Intelligence brief

### What happened Sungrow (300274.SZ), together with TÜV Rheinland and power-module suppliers including StarPower Semiconductor, onsemi and SiEn Integrated, released two jointly developed reliability test standards: 2 PfG 3325, "Reliability Test and Certification Standard for IGBT Modules Used in Photovoltaic Power Generation Systems and Power Electronic Conversion Systems," and 2 PfG 3328 Part 2, "Reliability Test and Evaluation Specification for Power Electronic Products – Part 2: Power Conversion Equipment (PCE)." The announcement was dated 2026-11-05 in the aggregated feed; the release ceremony itself is described only as having taken place "recently," with no city or venue stated. The two standards are aimed at two layers: the key power module and the complete PCE unit, forming a layered reliability evaluation path from component to system. At the ceremony, Sungrow technical experts explained that inverters run continuously and are among the most heavily loaded core devices in a PV plant, with power semiconductors exposed to high temperature, high humidity, dust and frequent start-stop cycles. They noted that increasingly diverse sites — desert, gobi, sandy, hilly, coastal and high-altitude — bring salt spray, wind-blown sand and thin air, adding to long-term reliability challenges. As the industry moves toward high-quality development, reliable operation across a 25-year lifecycle has become a shared concern for owners and investors, yet the industry has lacked a unified yardstick for proving it. Dr. Jiang Ke of Sungrow's ground-mounted PV product quality department described IGBTs as the "heart" of the inverter, with failures beginning invisibly — bond-wire fatigue from repeated thermal expansion, voids and cracks in solder layers, and slow chip degradation under high-temperature bias. 2 PfG 3325 builds on automotive electronics reliability practice (AQG 324) and IEC standards, setting three test categories around these failure mechanisms: bias and humidity (high-temperature reverse bias, high-temperature gate bias, humidity bias), thermo-mechanical (thermal shock, temperature cycling, power cycling), and environmental/mechanical (salt spray, vibration, shock, ESD), with parameters traceable before, during and after testing. Compared with conventional certification, the new standard adds a 1.1× VGESmax serial test after high-temperature gate bias, 1,000 thermal shock cycles and more than 60,000 power cycles. 2 PfG 3328 Part 2 defines five unified electrical operating conditions (E1–E5) and tests complete units under power in real high/low temperature, condensing humidity, salt spray and dust environments, adding 4,000-hour high-temperature accelerated aging, loaded high/low temperature cycling, humidity acceleration, start-stop and islanding-recovery tests. The two standards are interlocked: IGBT modules must pass 2 PfG 3325 before a complete unit is submitted, and component-level data can be traced if a device fails during unit testing. ### Key figures - Two standards released: 2 PfG 3325 (IGBT modules) and 2 PfG 3328 Part 2 (PCE units). - 25 years: the inverter lifecycle reliability target referenced by owners and investors. - 1.1× VGESmax serial test added after high-temperature gate bias testing. - 1,000 temperature shock cycles required. - More than 60,000 power cycles required. - 4,000 hours of high-temperature accelerated aging for complete units. - Five unified electrical operating conditions, E1–E5. - Three test categories in 2 PfG 3325: bias/humidity, thermo-mechanical, environmental/mechanical. - No financial figures, production capacity, market share or certification fee data disclosed. ### Why it matters to ebm-papst This is primarily a market-signal and standards-setting development. The new framework raises the bar for how inverter reliability is demonstrated over a 25-year lifecycle, and it was authored by a leading inverter maker together with a major certification body and semiconductor suppliers — a coalition that can shape procurement expectations for the whole PV value chain. For ebm-papst, inverters and PCE units are adjacent thermal-management territory: cooling capability degradation, rising losses and temperature rise, protection derating and restart behavior are explicitly named in the standard as chain reactions that component-level metrics cannot capture. That language pushes OEMs toward system-level validation of thermal design, which is where fans and cooling subsystems sit. Assessment (inference): If 2 PfG 3328 Part 2 gains traction with owners, investors and insurers, inverter OEMs may demand higher-confidence lifetime and accelerated-aging data from their cooling-component suppliers, including fan bearing life, high-temperature endurance and salt-spray/dust performance. ebm-papst could face new documentation and test-evidence requirements from PV customers, but also an opportunity to differentiate on validated long-life cooling and to position its products as enablers of the 25-year reliability claim. The absence of ebm-papst or any fan supplier from the listed participants suggests the cooling layer is not yet represented in this standards conversation — a gap worth monitoring and potentially engaging with, either directly or through customer OEM programs. No indication in the source that the standards address fans or cooling components specifically; that linkage is inference only.

## Full text (English translation)

Recently, Sungrow, together with TÜV Rheinland and module manufacturers including StarPower Semiconductor, onsemi and SiEn Integrated, jointly released two jointly developed reliability test standards — 2 PfG 3325 "Reliability Test and Certification Standard for IGBT Modules Used in Photovoltaic Power Generation Systems and Power Electronic Conversion Systems" and 2 PfG 3328 Part 2 "Reliability Test and Evaluation Specification for Power Electronic Products – Part 2: Power Conversion Equipment (PCE)." The two standards target key power modules and complete PCE units respectively, forming a layered reliability evaluation path from component to system.

The industry lacks a yardstick for verifying 25-year inverter health

At the release ceremony, Sungrow technical experts interpreted the standards.

In a PV plant, the inverter is one of the core devices that runs all year round and carries the heaviest workload, continuously performing power conversion and grid interaction day and night, while sensitive components such as power semiconductors inside endure high temperature, high humidity, dust and frequent start-stop cycles over long periods. At the same time, application scenarios such as desert, gobi, sandy, hilly, coastal and high-altitude sites are becoming increasingly diverse, and extreme environments such as salt spray, wind-blown sand and thin air pose increasingly severe challenges to the long-term reliable operation of inverters.

As the industry moves toward high-quality development, ensuring reliable operation of inverters throughout a 25-year full lifecycle is becoming a shared focus for owners and investment institutions. How to prove that an inverter "can run healthily for 25 years" — the industry has long lacked a unified yardstick.

One governs the "heart," the other governs the "complete unit"

Dr. Jiang Ke, of Sungrow's ground-mounted PV product quality department, shared the design philosophy and practice of reliable lifetime for PV inverter systems. He pointed out that IGBTs are the power devices in inverters that withstand high voltage and high current, equivalent to the "heart" of the equipment. Their failure often begins where the naked eye cannot see: bond wires fatigue and detach due to repeated thermal expansion and contraction, solder layers develop voids and cracks, and chips slowly degrade under high-temperature bias. The IGBT Reliability Test Standard (2 PfG 3325) is based on the automotive electronics reliability specification AQG 324 and relevant IEC standards, and sets three major categories of tests around these failure mechanisms: bias and humidity (high-temperature reverse bias, high-temperature gate bias, humidity bias), thermo-mechanical (thermal shock, temperature cycling, power cycling), and environmental and mechanical (salt spray, vibration, shock, electrostatic discharge). Parameters are traceable throughout pre-test, in-test and post-test, and every "test passed" corresponds to specific stress and physical evidence.

Compared with conventional certification, the new standard is noticeably strengthened: after high-temperature gate bias testing, a 1.1× VGESmax serial test is added, along with 1,000 temperature shock cycles and more than 60,000 power cycles, closing off hidden risks of premature failure under extreme operating conditions.

The PCE Reliability Test Standard (2 PfG 3328 Part 2) is like a "road test" for the complete unit. Its difficulty lies in putting environment, operation, control and protection on the same assessment boundary: the standard first defines five unified electrical operating conditions, E1–E5, then places the complete unit together with these conditions into real environments such as high and low temperature, humid condensation, salt spray and dust for a "live test," and adds rigorous 4,000-hour high-temperature accelerated aging, loaded high/low temperature cycling, humidity acceleration, start-stop and islanding recovery and other long-term dynamic assessments. The reliability of a complete unit is never a simple sum of component indicators — declining cooling capacity, rising losses and temperature rise, protection intervention and derating, and fault reset and restart form chain reactions, and this is exactly the question the complete-unit standard aims to answer.

Turning "feels reliable" into "calculable reliability"

Group photo at the release ceremony of Sungrow and TÜV Rheinland

The significance of the two standards must first be examined against the map of industry standards. In the past, whether IEC 62109 or relevant domestic specifications, the assessment of inverters was mainly based on safety and design qualification; "passing certification" did not equal "able to operate healthily for 25 years." With this release, Sungrow and TÜV Rheinland for the first time make "long-term reliability" an independently certifiable dimension: 2 PfG 3325 systematically transplants automotive-electronics-grade reliability methods (AQG 324, IEC 60747-9) to power converters, establishing a quantitative assessment benchmark for the IGBT "heart"; 2 PfG 3328 Part 2 covers almost all mainstream product forms, including micro inverters, string inverters, central inverters and PV-storage integrated machines, extending verification to the complete-unit level.

More critically, the two are interlinked and mutually preconditioned: before a complete unit is submitted for testing, its IGBT modules must first pass all assessments of 2 PfG 3325; if a key device fails during complete-unit testing, device-level data can be traced back to define the failure boundary, giving inverter reliability a unified "measure" for the first time. The two standards jointly released by Sungrow and TÜV Rheinland provide a structured, verifiable framework for building "quantifiable, predictable and preventable" reliability competitiveness of PV inverter products, and for manufacturers, investors and insurance institutions to evaluate full-lifecycle product performance, supporting customers in achieving long-lasting and sustained commercial value and driving industry competition from a focus on scale and price toward competition on stability, reliability and long-term value.

## Full text (original)

近日，阳光电源联合TÜV莱茵以及斯达半导体、onsemi、芯联集成等模块厂家共同发布两项联合开发的可靠性试验标准——2 PfG 3325《光伏发电系统及电力电子变换系统用IGBT模块可靠性试验认证标准》与2 PfG 3328 Part 2《功率电子产品可靠性试验与评价规范 第2部分：功率转换设备（PCE）》。两项标准分别面向关键功率模块与PCE整机，形成从器件到系统的分层可靠性评价路径。
行业缺少逆变器25年健康度验证标尺
发布仪式现场，阳光电源技术专家解读标准
在一座光伏电站中，逆变器是全年无休、任务最繁重的核心设备之一，需日夜不停地完成功率变换与电网交互，内部的功率半导体等敏感元件长期承受高温、高湿、粉尘和频繁启停的考验。与此同时，沙戈荒丘滩海等应用场景越来越多元化，盐雾、风沙、空气稀薄等极端环境，对逆变器的长期可靠性运行带来了越来越严峻的挑战。
随着行业迈向高质量发展，让逆变器25年全生命周期内可靠运行，正成为业主与投资机构共同关注的焦点。如何证明一台逆变器“能健康跑完25年”，行业一直缺少一把统一的尺子。
一个管“心脏”，一个管“整机”
阳光电源地面光伏产品质量部姜珂博士分享了光伏逆变系统可靠寿命设计理念与实践。他指出，IGBT是逆变器中承受高电压、大电流的功率器件，相当于设备的“心脏”。它的失效往往从肉眼看不见的地方开始：键合线因反复热胀冷缩而疲劳脱落，焊层出现空洞与裂纹，芯片在高温偏压下缓慢退化。《IGBT可靠性试验标准》（2 PfG 3325）以汽车电子可靠性规范AQG 324和IEC相关标准为基础，围绕这些失效机理设置了三大类试验：偏压与湿热类（高温反偏、高温栅偏、湿热偏压），热机械类（热冲击、温度循环、功率循环），环境与机械类（盐雾、振动、冲击、静电）。试前、试中、试后参数全程可追溯，每一次“试验通过”都对应具体应力与物理证据。
相比常规认证，新标准明显加码：高温栅偏测试后增加1.1倍VGESmax串行测试，1000次温度冲击循环测试，大于60000次功率循环测试，堵住极端工况下提前失效的隐患。
《PCE可靠性试验标准》（2 PfG 3328 Part 2）则像一场“整机路考”。它的难点在于让环境、运行、控制与保护站在同一条考核边界上：标准先定义E1—E5五种统一的电气运行工况，再把整机连同这些工况放进高低温、湿热凝露、盐雾沙尘等真实环境中“带电考试”，并加入了严苛的4000小时高温加速老化、高低温循环带载、湿热加速、启停以及孤岛恢复等长期动态考核。整机的可靠性从来不是零部件指标的简单相加——冷却能力下降、损耗与温升上升、保护介入降额、故障复位重启之间会形成连锁反应，这正是整机标准要回答的问题。
把“感觉可靠”变成“算得出来的可靠”
阳光电源与TÜV莱茵发布仪式合影
两项标准的意义，先要放在行业标准的版图上审视。过去无论IEC 62109还是国内相关规范，对逆变器的考核都以安全与设计鉴定为主，“通过认证”并不等于“能健康运行25年”。这次发布，阳光电源和TÜV莱茵第一次把“长期可靠性”变成可认证的独立维度：2 PfG 3325将汽车电子车规级可靠性方法（AQG 324、IEC 60747-9）系统移植到功率变流器，为IGBT这颗“心脏”建立了量化考核基准；2 PfG 3328 Part 2则覆盖微逆、组串、集中式逆变器、光储一体机等几乎所有主流产品形态，把验证延伸到整机层面。
更关键的是，两者环环相扣、互为前提：整机送测前，其IGBT模块须先通过2 PfG 3325的全部考核；整机试验中关键器件一旦失效，还可回溯器件级数据、界定失效边界，让逆变器可靠性第一次有了统一的“度量衡”。阳光电源与TÜV莱茵联合发布的这两项标准，为构建“可量化、可预测、可预防”的光伏逆变器产品可靠性竞争力，以及制造商、投资者与保险机构评估产品全生命周期表现提供了结构化、可验证的框架，支持客户实现长久持续的商业价值，推动行业竞争从关注规模与价格转向比拼稳定、可靠与长期价值。