海悟推出一体化冷源(干冷器),以风液融合方案赋能高密数据中心散热

Hiwave launches integrated dry cooler for air-liquid cooling data centers, claiming 75% shorter TTM and 15% efficiency gain
海悟科技新闻T12026-11-04 · CN · 海悟科技 Hiwave
新品技术发布数据中心/IT散热

情报详报

What happened Hiwave (Hiwave Technology), a Chinese thermal-management and digital-energy equipment supplier, published a product release on 4 November 2026 introducing its integrated cooling source unit — a dry cooler (dry cooler / air-cooled heat rejection unit) aimed at data centers that combine air cooling and liquid cooling. The announcement was made via the company's news channel; no customer, project site, or contract was named. The product integrates the dry cooler body, circulation pumps, piping, and control system into a single factory-prefabricated package, with optional wet-film and spray auxiliary cooling modules selectable per project. Hiwave positions it as a standardized, productized outdoor heat-rejection solution for high-density AI compute facilities, covering air-cooled, liquid-cooled, and cold-plate liquid-cooling architectures. The release is structured around five themes: high integration for faster deployment; air-liquid convergence for flexible adaptation to varying rack power densities; intelligent control for continuous optimization; year-round reliability (freeze, fouling, UV, and snow protection); and target scenarios including supercomputing centers, intelligent computing centers, integrated big data centers, city cloud-brain infrastructure, and cold-plate liquid-cooling data centers. Hiwave frames the launch against rising AI compute demand, increasing rack power density, and the need to cut water consumption and project timelines while improving energy efficiency — explicitly contrasting dry coolers with conventional cooling towers that rely on evaporative water loss. ### Key figures - Project TTM (time-to-market) shortened by 75%, per Hiwave. - System operating energy efficiency improved by 15%. - Opex reduced by 15%. - No specific figures disclosed on unit cooling capacity, airflow, price, production capacity, order volume, or market share. - No specific figures disclosed on WUE values or water savings. - No specific figures disclosed on deployment dates, customer names, or geographic markets. ### Why it matters to ebm-papst Hiwave is positioning an integrated, factory-prefabricated dry cooler as a standardized product for AI-era data centers — a segment where ebm-papst supplies fans and blowers for both air-side heat rejection and liquid-cooling CDUs. A productized dry cooler with integrated controls and optional spray modules is a natural host for EC fan arrays, so this is primarily a component opportunity rather than a direct competitive threat: ebm-papst does not sell integrated dry-cooler skids. The emphasis on air-liquid convergence matters because it widens the addressable fan content per facility — dry coolers, air-cooled condensing units, and cold-plate CDUs can coexist in the same hall, each needing fans and motors. Hiwave's stated 15% efficiency and Opex gains also raise the bar for fan-level efficiency and controllability, since system-level optimization claims increasingly depend on modulating EC fans with precise speed control and telemetry. Assessment (inference): Hiwave's 75% TTM reduction claim signals a shift toward prefabricated, skid-based outdoor cooling in China, which favors fan suppliers that can deliver standardized, pre-tested fan modules with documented performance curves and controls integration rather than bespoke assemblies. Assessment (inference): the absence of named customers or capacity figures suggests this is an early-stage product launch, so near-term volume impact is likely limited; the strategic signal — Chinese thermal-management vendors productizing dry coolers for AI campuses — is more significant than the launch itself. Assessment (inference): ebm-papst should treat Hiwave as a potential OEM/channel partner for EC fan arrays in dry coolers and CDUs, while monitoring whether Hiwave vertically integrates fans or sources them, which would change the competitive picture.

原文全文

原文 英文翻译
随着AI算力需求持续攀升,数据中心正加速向高密度、高功率、规模化方向演进。不断提升的机柜功率密度,对冷却系统的散热能力、部署效率、能源利用及运行可靠性提出了更高要求。 传统冷却模式已难以全面适应新一代数据中心的发展需求。如何在保障稳定散热的同时,降低水资源消耗、优化能源效率,并缩短项目建设周期,成为数据中心基础设施升级的重要课题。 以高效换热为基础,以风液融合为路径,以智能控制为核心,海悟一体化冷源(干冷器)通过高度集成的产品设计与智能化运行管理,为数据中心提供高效、节能、可靠的室外冷源解决方案。 01 高度集成|让冷源部署更高效 传统冷源系统涉及多个独立设备及管路组件,现场安装、管道连接与系统调试环节较多,对工程协同和交付周期提出了较高要求。 海悟一体化冷源采用高度集成化设计,将干冷器本体、循环泵、管道及控制系统进行一体化整合,并可根据项目需求选配湿膜、喷淋等辅助制冷系统,实现冷源设备的标准化、产品化交付。 通过工厂预制、系统集成与标准化调试,减少现场施工与设备安装工作量,支持项目TTM缩短75%,助力数据中心加快建设部署,实现从设备交付到系统投运的高效衔接。 02 风液融合|灵活适配多元散热需求 面对AI数据中心不断变化的算力负载,单一冷却方式已难以满足不同功率密度、不同运行阶段的散热需求。 海悟一体化冷源融合风冷与液冷冷源能力,可根据项目架构与负载需求灵活配置,实现风冷、液冷冷源的协同适配。 相较传统冷却塔依赖水蒸发散热的方式,干冷器主要通过空气与换热盘管进行热交换,减少对蒸发水资源的依赖,有效降低系统WUE,同时减少填料、水处理等相关维护需求。 配合可选辅助制冷系统,可根据不同地域气候条件及项目运行需求灵活配置,兼顾全年运行适应性与系统能效。 从风冷到液冷,从单一散热到多元协同,让冷源配置更灵活,让高密算力散热更从容。 03 智能寻优|让节能贯穿运行全过程 高效冷却不仅取决于设备性能,更取决于系统能否根据实际运行工况实现精准调节。 海悟一体化冷源标配智能控制系统,具备全自动运行与部件手动调试模式,可根据室内外环境变化、系统负载及运行状态,动态调节设备运行参数,实现制冷量精准匹配与系统运行寻优。 通过智能化控制与高效部件协同,优化设备运行策略,减少不必要的能源消耗。 系统运行能效提升15%,Opex降低15%,让节能从设备设计延伸至长期运营。 04 全年可靠|应对复杂环境与多变工况 数据中心冷却系统需要面对不同地域、不同季节及复杂气象条件的长期考验。 海悟一体化冷源针对室外运行环境进行可靠性设计,具备防冻、防污、防紫外线、防雪等能力,结合循环系统与智能控制策略,可根据环境变化持续调节制冷量,保障全年不同气象条件下的稳定运行。 从严寒到高温,从复杂气候到高负载运行,为数据中心提供持续、稳定的室外散热保障,满足智算中心、超算中心及高密度液冷数据中心的冷源需求。 05 多元场景|赋能新一代数字基础设施 依托高效换热、风液融合、智能控制及标准化集成优势,海悟一体化冷源可广泛应用于: - 超算中心 / 智算中心: 满足高密度算力基础设施的高效散热需求。 - 一体化大数据中心: 适配模块化、规模化部署需求,提升冷源系统建设效率。 - 城市云脑: 适应高热密度、持续运行的基础设施冷却需求。 - 冷板式液冷数据中心: 为液冷系统提供高效、稳定的室外冷源支持。 以高效冷却,支撑绿色算力未来 从设备集成到系统协同,从高效换热到智能寻优,海悟一体化冷源(干冷器)以产品化设计提升部署效率,以风液融合拓展场景适配能力,以智能控制优化全生命周期运行成本。 面向AI算力持续增长与数据中心绿色低碳转型,海悟将持续深耕数字能源与热管理技术,以更高效、更可靠、更智能的冷却解决方案,为新一代算力基础设施建设与发展提供有力支撑。