维谛技术(Vertiv)提出Tokenomics框架:从PUE转向每MW有效AI产出

Vertiv's Tian Jun proposes Tokenomics framework at CGC 2026 to measure AI output per contracted MW
中国IDC圈T22026-11-03 · CN · Vertiv 维谛技术
数据中心/IT散热新品技术发布

情报详报

What happened At the main forum of the 2026 Global Computing Conference (CGC), Dr. Tian Jun, Vice President of Marketing and Product Application for Vertiv Greater China, delivered a keynote titled "Tokenomics — From a New Economic Perspective, How to Maximize AI Output per MW of Contracted Power Through Infrastructure Optimization." The presentation introduced Tokenomics, a framework that quantifies AI infrastructure return on investment by measuring how much effective AI output (tokens) each contracted megawatt produces, mapping physical infrastructure performance directly onto the commercial value of an AI factory. Tian framed the shift as a fundamental reorientation of AI infrastructure logic: PUE measures how much power is wasted, while Tokenomics measures how much power is converted into effective compute output. He traced the attrition from contracted power to usable GPU power across five stages — grid interconnection and site readiness limits; redundancy reserves, topology headroom and distribution overhead; facility loads such as cooling, heat rejection, pumps, fans, lighting and controls; conversion losses plus network, CPU, memory and server fans; and finally thermal throttling, instability, downtime and maintenance derating. Only the cooling-and-distribution segment is visible to PUE, he noted. Tian also compared industry-median and industry-leading deployments of comparable contracted power and GPU scale, saying the leaders retain materially more power at the compute end and deliver markedly more tokens per second per MW and more daily compute value per MW. Tokenomics rests on four core metrics — Tokens per Second (effective throughput), Tokens per Watt (energy productivity), Tokens per Dollar (economic productivity) and Time to First Token (revenue speed) — converging on tokens per second per MW. Vertiv positions its "fully integrated physical infrastructure" concept, embodied in the Vertiv OneCore integrated infrastructure solution, as the answer, combining 800 VDC architecture, UPS power smoothing and fault ride-through, MV BESS UPS for AI pulsed loads, higher-water-temperature liquid cooling, and prefabricated, digitally validated reference designs with integrated power, cooling and IT delivery. ### Key figures - Five stages of power attrition identified between contracted power and effective GPU power. - Four core Tokenomics metrics: Tokens per Second, Tokens per Watt, Tokens per Dollar, Time to First Token. - 800 VDC architecture cited as a means to reduce conversion stages. - Vertiv cites 60+ years of development history and, in China, 3 R&D centers, 3 manufacturing bases, 30+ offices and customer service centers, and 100+ city business support centers. - No specific figures were disclosed for the magnitude of power losses at each stage, the size of the median-versus-leading performance gap, or projected customer savings. ### Why it matters to ebm-papst The article explicitly places fans among the facility and IT loads that consume power before it reaches effective compute — cooling and heat-rejection fans on the facility side, and server fans on the critical IT side. A framework that scores infrastructure on tokens per MW rather than PUE shifts buyer attention toward every conversion and thermal loss in the chain, including fan energy and thermal-throttling avoidance. Assessment (inference): Vertiv's push toward higher-water-temperature liquid cooling and integrated, prefabricated power-and-cooling skids could reduce the share of conventional air-movement content in AI factory cooling designs, which is a competitive threat to fan-centric incumbents in that segment. Assessment (inference): At the same time, the emphasis on system-level thermal optimization and avoiding GPU throttling creates a customer opportunity for high-efficiency, high-static-pressure fan and EC motor solutions positioned on tokens-per-watt rather than unit price. Assessment (inference): Vertiv is setting the vocabulary — Tokenomics, tokens per MW — that hyperscale and colocation customers may soon use in tenders, so ebm-papst should prepare quantified airflow-per-watt and thermal-headroom arguments mapped to those four metrics. Assessment (inference): Vertiv's integrated OneCore approach may favor pre-validated component suppliers early in reference designs, raising the value of engaging Vertiv's Greater China team now. No specific figures on fan content or market share were disclosed.

原文全文

原文 英文翻译
当AI从模型竞赛走进算力基建竞赛,一座AI Factory到底值不值钱,正在被重新定义。过去十年,人们习惯用机柜数量、装机规模来判断一座数据中心的价值,用PUE判断它是否高效。但一个更直接的问题已经摆到所有建设者面前:同样投入100MW的合同电力,究竟能换来多少真正可用的AI产出? 近日,在 2026 全球计算大会(CGC)主论坛上,维谛技术(Vertiv)大中华区市场营销及产品应用部副总裁田军博士以《Tokenomics——从经济新视角,如何通过基础设施优化,实现每MW合同电力的最大AI产出》为题发表演讲,提出了衡量AI基础设施经济效益的新框架——Tokenomics:以每个合同MW能产生多少有效AI输出(Token)来量化投资回报,把物理基础设施的性能,直接映射到AI工厂的商业价值。 在他看来,PUE衡量的是“电浪费了多少”,而Tokenomics衡量的是“电变成了多少有效算力产出”。从前者到后者,是AI基础设施建设逻辑的一次根本转向。 合同电力并不等于算力电力:一座园区要穿过五道关口 判断一座AI Factory的真实产出,要先从电力说起。 从合同电力出发,电并不直接进入算力,而要在不同环节被多次“打折”:并网与接入限制、限电和场地就绪,让可交付的站点电力先缩水一部分;冗余预留、拓扑裕量和配电开销,再让设施可用电力退一步;制冷、排热、水泵、风机、照明与控制,又占用掉一笔可观的设施负载;电能转换损耗、网络、CPU、内存与服务器风扇,继续从关键IT电力上切走一块;走到最后,热降频、运行不稳定、停机与维护降额,还会让额定GPU电力再打一次折。 层层递减之后,真正留给有效算力的电力,已经明显低于当初签下的合同容量。名义上的装机规模与最终在产出Token的算力,中间隔着一整条会持续漏损的链路。 而这五道关口里,只有“制冷与配电”这一段,是PUE能够看见的。所以田军博士强调,真正值得算清楚的,不只是电消耗了多少,而是——从政府获得的电力容量,究竟有多少真正变成了AI生产力。 同样的兆瓦,不同的产出:差距不在芯片里 如果说电力在传输与转换中损耗惊人,那么Token产出效率的差距更值得深究。 田军博士给出了一组对比:同样是合同电力、同样规模的GPU集群,行业中位水平与行业领先水平,在设施可用电力、关键IT电力到有效GPU电力上的逐级留存并不相同,留在算力端的电力差距尤其突出;折算到产出端,每兆瓦每秒能跑出的Token数量以及每天每兆瓦对应的算力价值,领先者都明显高出一截。 也就是说,同样的电力投入,最终产出相差悬殊。这道差距不产生在芯片里,而产生在从电力接入到算力输出的整条基础设施链路——同样的电,进去的方式不同,出来的算力就不同。 为了把这道账算清楚,Tokenomics覆盖全链路经济产出,用四个核心指标回答客户最关心的问题:Tokens per Second是有效吞吐,衡量算力的最大产出能力;Tokens per Watt是能源生产率,衡量有限电力能换来多少产出;Tokens per Dollar是经济生产率,衡量每一美元能创造多少Token;Time to First Token是收入速度,衡量从签约到首个Token产出需要多久。 四个指标最终收束为一个终极指标:每兆瓦每秒,能产出多少Token。 把每一级漏损收回来:系统融合,才是 Token 价值的放大器 让每一MW电力创造更多Token,答案并不是简单增加设备,也不是单独提升某个环节的效率。因为决定AI Factory最终产出的,是从电力接入到算力运行的整个系统。 对应前文的漏损链路,抓手其实清晰。在供电架构上,通过800 VDC架构减少转换级数,以 UPS功率平滑和故障穿越稳住负载,用MV BESS UPS应对AI脉冲负载,把冗余预留与转换环节丢掉的那部分电力尽量收回来;在热管理上,以更高水温的液冷运行、热链路系统级优化,把设施负载与热降频带来的损失收回来;在交付与复制上,用工厂预制、数字化验证的参考设计,以及电力、制冷与IT的一体化交付,压缩Time to First Token,堵住接口处的容量泄漏。 由此可见,只有从单点优化走向系统协同,才能让每一环节的改善,转化为整个AI Factory的产出价值。这也正是维谛技术(Vertiv)“全融合物理基础设施”理念的核心所在。同时,这一理念已经落地为具体的基础设施解决方案——Vertiv™ OneCore全融合基础设施解决方案,通过供电、制冷与IT基础设施的集成化设计,以及预制化、模块化的交付方式,减少传统现场集成的复杂性,为AI Factory的快速部署和规模化复制提供支持。 不再拼 MW,而是拼 Token:AI Factory的下一场竞赛 站在产业视角,AI Factory的竞争正在从规模走向效率。 当密度、速度、规模、复杂度与负载特性五股力量叠加,传统“现场拼装、子系统逐个优化”的方式已经跟不上GW级建设的节奏。Tokenomics提供的,正是一种从投入走向产出的新视角——从关注建了多少MW,到关注产出了多少Token。 电力,正在成为AI时代最稀缺的生产要素。谁能让每一瓦电力更充分地转化为有效算力,谁就掌握了下一轮竞争的主动权。当衡量标准从“电有没有被浪费”转向“电变成了多少有效产出”,改变的不仅是评价方式,更是整个AI基础设施的设计逻辑。 从“建得出MW”到“产得出Token”,维谛技术(Vertiv)凭借前瞻视野和完整产品线优势,正以“全融合物理基础设施”理念,驱动AI Factory高效释放Token生产力。 版权声明:© 2026 Vertiv Group Corp. All rights reserved. 关于维谛技术(Vertiv) 维谛技术(Vertiv, NYSE: VRT, 原艾默生网络能源),是一家全球领先的数字基础设施解决方案提供商,在通信网络、数据中心、商业&工业、新能源等领域拥有60+年的发展历史。维谛技术的产品广泛覆盖了政府、电信、金融、互联网、科教、制造、医疗、交通、能源等客户群体,为客户提供覆盖各个领域关键基础设施的电力、制冷和IT基础设施解决方案和技术服务组合。 维谛技术的客户遍布全球,在中国拥有3大研发中心和3大生产基地,覆盖全国范围的30+办事处和用户服务中心、100+城市业务支持中心,为客户提供高可靠高质量的产品方案和专业卓越的技术服务,共同构建关键技术悦动在线keep it hummingTM的美好世界。如需了解更多信息,欢迎访问Vertiv.com,售前热线400-887-6526。