### What happened In October 2026, Sungrow (300274.SZ) completed a large-scale fire test (LSFT) on its new-generation AC smart energy storage product, PowerTitan 3.0. According to the source (PV Headline), this is the industry's first laminated-cell AC energy storage system to complete a test at this scale. The test setup comprised a 28.56MWh fully liquid-cooled PowerTitan 3.0 system plus a 7.4MW medium-voltage system, built to a 1:1 real-station layout. PowerTitan 3.0 integrates the battery system and PCS into a single 20-foot cabinet. Test conditions were deliberately severe: the ignition cabinet A was installed back-to-back and flush against adjacent cabinet B; all battery cabinets were at 100% SOC; active firefighting and thermal management systems were fully shut down; and the top pressure-relief panel of cabinet A was fully opened. The fire burned for 7.5 hours, with peak internal temperature in cabinet A reaching 1259.8°C. The fire remained confined to cabinet A, and cell temperatures in adjacent cabinets stayed well below the thermal runaway threshold. All cabinets — including the ignition cabinet A and adjacent B, C, D and E — reportedly remained structurally intact and undeformed, and could still be lifted as complete units after the fire. Smoke and emissions were collected and treated by a dedicated purification system. With this test, all three generations of the PowerTitan series (1.0, 2.0 and 3.0) have passed rigorous full-scale fire testing on the first attempt. Sungrow frames the exercise as "burning in order to not burn," arguing the value lies less in a test report than in building a complete, credible evidence chain for system-level safety and project bankability. The company also cites the evolving standards landscape: UL 9540A Edition 6 was published in March 2026, adding large-scale fire test requirements and explicitly requiring LSFT to demonstrate that fire does not propagate between energy storage units; NFPA 855 (2026 edition) has made large-scale fire testing mandatory; and CSA/ANSI C800-2025 provides an approved, standardized large-scale burn test method from a reliability perspective. Sungrow says the PowerTitan 3.0 test was conducted in accordance with both UL 9540A:2026 and CSA/ANSI C800-2025. ### Key figures - Test scale: 28.56MWh PowerTitan 3.0 fully liquid-cooled system plus a 7.4MW medium-voltage system, built to a 1:1 real-station layout. - Cabinet format: battery system and PCS integrated in a single 20-foot cabinet (AC Block architecture). - Test conditions: 100% SOC across all battery cabinets; active firefighting and thermal management shut down; ignition cabinet A pressure-relief panel fully open; cabinets A and B installed back-to-back and flush. - Burn duration: 7.5 hours. - Peak temperature inside ignition cabinet A: 1259.8°C. - Fire containment: no propagation to adjacent cabinets B, C, D and E; all cabinets structurally intact and liftable after the test. - Cell specification: 600Ah+ laminated (stacked) energy storage cells. - Fire barrier performance: battery and electrical compartment separation with nano-scale isolation layer, non-conductive at high temperature, fire resistance ≥2 hours. - Prior test data: PowerTitan 1.0 — 10MWh full-scale data (test completed June 2024); PowerTitan 2.0 — 20MWh, 25 hours 43 minutes, 15cm spacing extreme-condition data. - Standards timeline: UL 9540A Edition 6 published March 2026; NFPA 855 2026 edition makes LSFT mandatory; CSA/ANSI C800-2025 provides a standardized large-scale burn test method. - Simulation: several hundred operating conditions simulated and used for design optimization before the physical burn. ### Why it matters to ebm-papst Sungrow is positioning system-level fire safety — not cell-level safety alone — as a core differentiator, backed by three generations of full-scale burn data and participation in standards development. For ebm-papst, this is primarily a market signal about where energy storage safety requirements are heading: UL 9540A Edition 6 and NFPA 855 2026 make large-scale fire testing a certification gate rather than a best practice, which will push the entire industry toward system-level thermal management, compartmentalization and fire-containment design. Assessment (inference): As a supplier of fans and thermal-management components for energy storage cooling systems, ebm-papst faces both opportunity and risk. The opportunity is that stricter propagation-prevention requirements raise the value of robust, verifiable active cooling and thermal management — including the ability to keep adjacent cabinets below thermal runaway thresholds — and could expand demand for higher-reliability, higher-IP, fire-rated air-moving solutions in AC Block and liquid-cooled architectures. The risk is competitive: Sungrow's fully liquid-cooled PowerTitan 3.0 design, with the DC side confined inside the cabinet, may reduce reliance on certain air-cooling components, and Sungrow's growing in-house safety evidence chain strengthens its bargaining position with suppliers. Assessment (inference): ebm-papst should monitor whether Sungrow's AC Block and liquid-cooling approach becomes an industry template, and should prepare documentation and test evidence showing how its air-moving and thermal components contribute to system-level non-propagation, since customers will increasingly demand supplier-level proof aligned with UL 9540A:2026 and CSA/ANSI C800-2025. No specific figures on procurement volumes, supplier shares or commercial terms were disclosed in the source.

## Full text (English translation)

(Source: PV Headline)
In recent years, the energy storage industry has been broadly gripped by safety anxiety: standards keep tightening, testing keeps escalating, and accidents still occur from time to time.
For Sungrow, safety can be described as its trump card. In recent years, its energy storage systems have ranked first on the BNEF bankability list, and its safety system has played an indispensable role. Large-scale fire testing is one important element of that.
01
Three fire tests! What exactly is Sungrow testing?
In October 2026, the new-generation AC smart storage product PowerTitan 3.0 completed a large-scale fire test, making it the industry's first laminated-cell AC smart storage system to complete a fire test at this level.
The test scale was a 28.56MWh fully liquid-cooled PowerTitan 3.0 system plus a 7.4MW medium-voltage system, built according to a 1:1 real-station layout.
PowerTitan 3.0 adopts an AC smart storage solution, with the battery system and PCS integrated into a single 20-foot cabinet. The test was conducted under severe conditions: ignition cabinet A and adjacent cabinet B were installed back-to-back and flush against each other. All battery cabinets were at 100% SOC, active firefighting and thermal management systems were fully shut down, and the top pressure-relief panel of ignition cabinet A was fully opened.
The fire lasted 7.5 hours, and the peak internal temperature of ignition cabinet A reached 1259.8°C. The fire was firmly locked inside cabinet A, and cell temperatures in adjacent cabinets were far below the thermal runaway critical threshold. All cabinets — including ignition cabinet A and adjacent cabinets B, C, D and E — remained structurally intact and undeformed, and could still be lifted as complete units after the fire. Smoke and emissions generated by the test were all collected and treated by a dedicated purification system.
At this point, all three generations of the PowerTitan series — 1.0, 2.0 and 3.0 — have passed rigorous real-machine fire verification on the first attempt. At the same time, Sungrow proposed the concept of "burning in order to not burn," whose deeper value lies not merely in obtaining a test report, but in completing a full credible evidence chain for system-level energy storage safety, adding another key safeguard for the bankability of energy storage projects.
Behind the test, the safety design that allowed all three generations to pass the fire test on the first attempt is worth mentioning. It can be roughly viewed at two levels: on one hand, system-level full-dimensional safety technology; on the other, long-term empirical accumulation.
02
System-level safety! From cell to power station
For fire testing, true safety is not only about preventing fire propagation after thermal runaway occurs, but more importantly about systematically reducing the risk of thermal runaway from the source through design.
In Sungrow's product logic, safety is not an add-on function attached to a certain link, but an underlying capability that permeates level by level from cells, electrical systems and system integration to station-level architecture — a deep coupling of "three-electricity integration" at the system level.
When encountering an extreme fire under normal operating conditions, it can be roughly understood as all energy storage systems at 100% SOC, with active firefighting and thermal management shut down and pressure-relief panels fully open. Under such test conditions, safety redundancy exists not only at the cell level, but is a whole set of system architecture designs for heat isolation, heat dissipation and fire protection.
At the cell level, PowerTitan 3.0 carries 600Ah+ laminated-process energy-storage-dedicated cells. Compared with winding, the engineering advantage lies in uniform electrode stress distribution, no stress concentration at curved corners, and lower lithium plating risk.
At the electrical level, PowerTitan 3.0 adopts the AC Block architecture, confining the DC side inside the cabinet. DC cables do not leave the cabinet, the path is short, and multiple branches make arcing difficult, structurally reducing the probability of DC arcing caused by insulation failure. ArcDefender 2.0 technology uses the PCS as an integrated carrier and, through TMR high-precision sensing and dynamic algorithms, achieves precise identification and rapid arc extinction, and has been widely applied in PowerTitan products.
In terms of fire safety: battery and electrical compartment design, nano-scale isolation layer, no conduction at high temperature, fire resistance ≥2h; integrated advantages of "isolation, detection, discharge, drainage and extinguishing," integrating cell-level intelligent diagnostic detection, system-level three-dimensional firefighting, station-level zero-propagation structural design, etc., and an intelligent linked firefighting system, so that extreme thermal runaway does not cause fire; three consecutive generations of large-scale combustion empirical evidence, so that extreme fire does not propagate.
Sungrow has repeatedly emphasized one judgment: "Energy storage safety is far more than cell safety." Energy storage safety is the result of multiple factors working together, including cell performance, system integration, thermal management, structural protection and engineering design.
The degree of standard evolution also shows that the focus of energy storage safety certification is moving up from "cell/module-level thermal runaway behavior" to "system-level fire non-propagation."
In March 2026, UL 9540A Edition 6 was officially published, adding large-scale fire test requirements and explicitly requiring LSFT to prove that fire will not propagate between energy storage units. At the same time, NFPA 855 2026 edition has made large-scale fire testing a mandatory requirement. CSA/ANSI C800-2025 provides an approved large-scale combustion test method from a reliability perspective, standardizing combustion testing.
03
Significance of standardization! When combustion testing goes from "optional" to "admission ticket"
Sungrow's PowerTitan 3.0 test was executed in accordance with both UL 9540A:2026 and CSA/ANSI C800-2025, but its standardization significance does not lie in "meeting the latest standards." What is truly noteworthy is the database accumulated while participating in standards.
The first-generation test was completed in June 2024, when UL 9540A Edition 6 had not yet been published and LSFT had not yet been formally incorporated into the certification process. Before the standard became mandatory, Sungrow had already accumulated 10MWh real-machine data for PowerTitan 1.0 and extreme data for PowerTitan 2.0 of 20MWh/25 hours 43 minutes/15cm spacing. Now it has also accumulated data for the 28.56MWh laminated-cell AC Block system of PowerTitan 3.0.
The database across generations means that when facing the requirements of UL 9540A:2026, Sungrow is not "responding to a new test" but calling on a calibration system that has already been running for three generations.
From the perspective of industry competition, when most companies begin preparing for standard changes, Sungrow has already used measured data from three generations of products to form a safety evidence chain that exceeds the minimum requirements of standards.
When combustion testing moves from "best practice" to "certification admission," latecomers can obtain a certificate through one test, but cannot obtain three generations of fire behavior data, nor the simulation models and safety design capabilities that were prepared in advance and repeatedly calibrated.
04
Turning "combustion testing" into "replicable safety"
Li Guohong, general manager of Sungrow's power storage product line, said: "Burning is in order to not burn. Time and again, at no expense spared, combustion tests ultimately have only one goal: the power station does not catch fire, and if it catches fire, it does not propagate, achieving replicable safety."
The database is the foundation of three generations of products, and what helped them pass the test on the first attempt is their simulation and other capabilities. Before the physical burn, PowerTitan 3.0 completed simulation deduction and design optimization for hundreds of operating conditions based on data accumulated from previous tests. The actual burn results showed that the fire scale and fire evolution trends predicted by simulation were highly consistent with the physical test.
Liu Jie, engineering manager at UL Solutions, said: "Through large-scale fire testing, the fire behavior and fire propagation of energy storage systems can be evaluated under specific test conditions. The results of this test show that, under specific test conditions, the fire did not propagate to adjacent energy storage units, providing important test data for evaluating the fire safety performance of the system."
This means the function of combustion testing has undergone a fundamental shift: in the logic of most companies, testing is the endpoint, and passing means obtaining certification; in Sungrow's logic, it is not only the product, but also the accuracy of simulation prediction that must be verified.
And by calibrating simulation models through measured results, more extreme operating conditions can be predicted and analyzed at the design stage, risks can be identified in advance, safety design can be optimized, and safety verification can be extended from a single test to a broader range of application scenarios.
Final note: an industry proposition that needs to be taken seriously
If combustion testing is understood as a publicity competition of "who burns harder, who burns bigger," then it consumes social resources and produces a one-time communication asset.
The judgment put forward by Sungrow in its test statement deserves serious attention from the industry: safety is not burned out, it is designed; burning is only to prove that the design can be trusted.
The ultimate point of "burning in order to not burn" is not only that PowerTitan 3.0 successfully prevented fire propagation at an extreme high temperature of 1259.8°C, but also that it verified the safety of the AC smart storage system design equipped with laminated cells, and the feasibility of "safety design - predictive simulation - large-scale measured verification."
This methodology is not limited to a single product or a single test, but continuously empowers safety design and iteration. "Passing on the first attempt" is no longer the ultimate goal; "replicable safety" is.

## Full text (original)

（来源：光伏头条）
近年来，储能行业普遍陷入安全焦虑：标准持续收紧、测试不断加码，事故时有发生。
而阳光电源，安全可以说是它的王牌。近年来，它的储能系统在BNEF可融资性榜单中排名第一，安全体系功不可没。大规模火烧测试，更是其中的重要一项。
01
三次燃烧测试！
阳光电源究竟在测什么
2026年10月，新一代交流智储产品PowerTitan 3.0完成大规模火烧测试，这也是业内首个完成该级别火烧测试的叠片电芯交流智储系统。
这次的测试规模为28.56MWh全液冷PowerTitan 3.0系统加7.4MW中压系统，按1:1真实场站布局搭建。
PowerTitan 3.0采用交流智储方案，电池系统与PCS集成于20尺单柜内。测试在严苛条件下进行：起火A箱与相邻B箱背靠背紧贴安装。所有电池箱100% SOC、主动消防与热管理系统全部关停，起火A箱顶部泄爆板完全开启。
燃烧持续7.5小时，起火A箱内部峰值温度达1259.8℃，火势牢锁A箱内，相邻箱体电芯温度远低于热失控临界阈值。所有箱体——包括起火A箱和相邻的B、C、D、E箱——结构完整、无变形，火烧后仍可作为完整单元起吊。测试产生的烟气和排放物均经专用净化系统收集处理。
至此，PowerTitan系列 1.0、2.0、3.0 三代产品全部一次性通过严苛的真机火烧验证。同时，阳光电源提出“烧是为了不烧”的理念，其深层价值不止是拿到一份测试报告，更是在储能系统级安全上补齐一整套可信证据链，为储能项目的可融资性再增加一道关键保障。
在测试背后，三代都一次性通过火烧的安全设计更值得一提。可以大致看成两个层面，一方面是系统级的全维安全技术，一方面是长期的实证积累。
02
系统级安全！
从电芯到电站
对于火烧测试而言，真正的安全不仅是发生热失控后防止火灾蔓延，更重要的是通过系统性设计，从源头降低热失控发生的风险。
在阳光电源的产品逻辑里，安全不是附着在某个环节上的附加功能，而是从电芯、电气、系统集成到站级架构逐级渗透的底层能力，是 “三电融合”在系统层面的深度耦合。
在正常运行状态下遇到极端火灾，可以大致理解为所有储能系统100% SOC、关停主动消防和热管理、泄爆板全开。这种测试条件下，安全冗余不仅存在于电芯层面，是一整套系统架构的隔散热和防火等设计。
电芯层面，PowerTitan 3.0搭载600Ah+叠片工艺储能专用电芯，相比卷绕的工程优势在于极片应力分布均匀、无弧形拐角应力集中，析锂风险更低。
电气层面，PowerTitan 3.0采用AC Block架构，将直流侧限制在柜内，直流线缆不出柜、路径短、多支路难以起弧，从结构上降低了因绝缘失效导致直流拉弧的概率。ArcDefender 2.0技术以PCS为集成载体，通过TMR高精度传感和动态算法实现拉弧的精准识别与快速灭弧，并已在PowerTitan产品中广泛应用。
消防安全方面：电池、电气隔舱设计，纳米级隔离层，高温不传导，耐火≥2h；“隔探排泄消”一体化优势，融合电芯级智能诊断探测、系统级立体消防、站级零蔓延结构设计等，智能联控消防系统，极端热失控不起火；连续三代大规模燃烧实证，极端起火不蔓延。
一直以来，阳光电源反复强调一个判断：“储能安全远不止电芯安全”。储能安全是电芯性能、系统集成、热管理、结构保护、工程设计等多重因素共同作用的结果。
标准的演进程度也可见，储能安全认证的重心正在从“电芯/模组级热失控行为”上移到“系统级火灾不蔓延”。
2026年3月，UL 9540A第六版正式发布，新增大规模火灾测试要求，并明确要求通过LSFT证明火灾不会在储能单元之间蔓延。与此同时，NFPA 855 2026年版已将大规模火灾测试列为强制性要求。CSA/ANSI C800-2025则从可靠性角度提供了获批的大规模燃烧测试方法，将燃烧测试标准化。
03
标准化意义！
当燃烧测试从“选做题”变成“准入证”
阳光电源PowerTitan 3.0的测试，同时依据UL 9540A:2026和CSA/ANSI C800-2025执行，但它的标准化意义并不在于“满足了最新标准”。真正值得注意的是他们参与标准的同时，沉淀的数据库。
第一代测试在2024年6月完成，彼时UL 9540A第六版尚未发布，LSFT尚未被正式纳入认证流程。阳光电源在标准强制之前已经积累了PowerTitan 1.0的10MWh真机数据、PowerTitan 2.0的20MWh/25小时43分钟/15厘米间距极限数据。现在，又积累了PowerTitan 3.0的28.56MWh叠片电芯AC Block系统数据。
历代数据库，使得阳光电源在面对UL 9540A:2026的要求时，不是在“应对一项新测试”，而是在调用一套已经运行了三代的校准体系。
从行业竞争的视角看，当多数企业开始为标准变化做准备时，阳光电源已经用三代产品的实测数据形成了一条超出标准最低要求的安全证据链。
当燃烧测试从“最佳实践”变成“认证准入”时，后来者可以通过一次测试获得一张证书，但无法获得三代火灾行为数据，和提前准备、反复校准的仿真模型和安全设计能力。
04
把“燃烧测试”变成“可复制的安全”
阳光电源电力储能产品线总经理李国宏表示：“烧是为了不烧。一次次不惜代价的燃烧测试，最终目标只有一个，电站不起火，起火不蔓延，实现安全可复制。”
数据库是三代产品的地基，而帮助一次性通过测试的则是他们的仿真等能力。物理实烧之前，PowerTitan 3.0基于历代测试积累的数据完成了数百种工况的仿真推演与设计优化，实烧结果显示仿真预测的火灾规模、火势演化趋势与物理测试高度吻合。
UL Solutions工程经理刘杰表示：“通过大规模火烧测试，可以在特定测试条件下评估储能系统的火灾行为及火势蔓延情况。本次测试结果显示，在特定的测试条件下，火势未蔓延至相邻储能单元，为评估该系统的火灾安全性能提供了重要的测试数据。”
这意味着燃烧测试的功能发生了根本性迁移：在多数企业的逻辑中，测试是终点，通过即获得认证；在阳光电源的逻辑中，不仅是产品，还要验证仿真预测准确度。
而通过实测结果校准仿真模型，可以在设计阶段就对更多极端工况进行预测分析，提前识别风险、优化安全设计，让安全验证从单次测试延伸到更广泛的应用场景。
写在最后：一个需要被正视的行业命题
如果燃烧测试被理解为一场“谁烧得更狠、谁烧得更大”的传播竞赛，那么它消耗的是社会资源，产出的是一次性的传播资产。
阳光电源在测试声明中提出的判断值得行业认真对待：安全不是烧出来的，是设计出来的；烧只是为了证明设计可以被信任。
“烧是为了不烧”的最终落点，不只是PowerTitan 3.0在1259.8℃极端高温下成功阻止火灾蔓延，更检验了搭载叠片电芯的交流智储系统设计方案的安全性，与“安全设计-预测性仿真-大规模实测验证”的可行性。
这套方法论也不局限于单款产品或单次测试，而是持续赋能安全设计与迭代。“一次通过”不再是最终目标，“安全可复制”才是。