FläktGroup builds first 2.5MW DX CDU in Arkansas for US data centre customer, targeting 200MW campus
Cooling PostT22026-10-30 · INTL
新品技术发布数据中心/IT散热冷链商超

情报详报

What happened FläktGroup has produced its first 2.5MW direct-expansion (DX) coolant distribution unit (CDU) for a customer in the USA, an item the company frames as a milestone in liquid cooling for next-generation data centres. The unit was built at FläktGroup's Arkansas facility and is described as having been specifically engineered by a dedicated team of experts to address modern data centre application requirements. The CDU is refrigerant-based rather than the conventional liquid-to-liquid architecture, and was developed in close collaboration with the customer to meet that specific project's requirements. Marc Hayes, FläktGroup's executive vice-president, data centres Americas, said the project demonstrates the company's ability to develop innovative solutions addressing emerging customer challenges as the industry increasingly adopts liquid cooling to support AI applications, and that it strengthens FläktGroup's position in the rapidly evolving data centre cooling market. The deployment is phased. The first phase is intended to serve a 25MW data hall; a second phase would double capacity to 50MW. That in turn forms part of a wider campus with a total planned power capacity of 200MW across eight development phases. ### Key figures - CDU capacity: 2.5MW (DX, refrigerant-based) - First unit manufactured at FläktGroup's Arkansas facility - Phase 1 data hall: 25MW - Phase 2: doubled to 50MW - Wider campus planned capacity: 200MW - Campus development phases: eight - Announcement date: 30 October 2026 - Customer identity, order value, unit volumes and delivery schedule: not disclosed ### Why it matters to ebm-papst The announcement is a demand signal for air movement and thermal management content in liquid-cooled AI data halls. A refrigerant-based DX CDU still relies on heat rejection to ambient, which typically means condensers, dry coolers or adiabatic units with fan arrays, plus pumps, controls and possibly cabinet-level air movers in the white space. A 200MW campus across eight phases implies a multi-year, repeatable equipment pipeline rather than a one-off build. FläktGroup is a direct competitor in data centre air handling and cooling, and this positions it as a supplier of integrated liquid cooling infrastructure, not only CRAH/air handling units. That expands its scope in accounts where ebm-papst fans are specified inside air handling and cooling equipment. Assessment (inference): The refrigerant-based DX approach, if it scales, could shift some cooling load from chilled-water infrastructure to refrigerant circuits, changing the fan and blower content mix per MW — potentially favouring condenser and dry cooler fan arrays over chilled-water coil units. Assessment (inference): ebm-papst should treat US AI campus projects of this shape as a priority specification target, tracking the Arkansas-built CDU platform's supply chain and the customer's identity, and positioning EC fan and control offerings for the heat-rejection side, where the 200MW build-out implies the largest cumulative fan volume. Assessment (inference): the phased 25MW-to-50MW structure suggests procurement decisions recur at each phase, giving multiple entry windows rather than a single locked specification.

原文全文

FläktGroup produces milestone 2.5MW CDU 30th October 2026USA: Described as a milestone in providing liquid cooling solutions for next generation data centres, the FläktGroup has produced its first 2.5MW DX CDU for a customer in the USA. Built at FläktGroup’s Arkansas facility, the refrigerant-based CDU has been specifically engineered by a team of experts to address the needs of modern data centre applications. “As the industry increasingly adopts liquid cooling to support AI applications, this project demonstrates our ability to develop innovative solutions that address emerging customer challenges while strengthening our position within the rapidly evolving data centre cooling market,” said FläktGroup’s executive vice-president, data centres Americas, Marc Hayes. Unlike conventional liquid-to-liquid systems, this CDU utilises refrigerant-based cooling technology and was developed in a close collaboration with the customer to meet the specific project requirements. The first phase of the project aims to serve a 25MW data hall. A second phase, will double the capacity to 50MW. This will form part of a wider campus with a total planned power capacity of 200MW across eight development phases.