# Hiwave unveils fast, safe, economical full-stack liquid cooling at HVAC&R annual meeting in Guiyang

- Source: Hiwave News (T1)
- Published: 2026-10-30
- Score: 72.0
- Tags: Product launch, Datacenter
- Companies: Hiwave
- Original: https://www.haiwu.com/news/dynamic/2180.html

## Intelligence brief

### What happened Hiwave presented its full-scenario AIDC (AI data center) data center solutions at the 25th HVAC&R Academic Annual Meeting, which opened on October 28 in Guiyang, China. The event, described as a key industry-academia-research-application exchange platform for the HVAC&R field, gathered 30 regional societies and more than 1,000 industry participants to discuss technology innovation and industry development directions. At the event, Zhu Haolin, Director of Hiwave's Marketing Center, delivered a keynote titled "Data Center Cooling Solutions for the Next-Generation AI Factory." Addressing trends in AI computing infrastructure, he shared Hiwave's technical practices in modular prefabrication, liquid cooling system reliability, and high-efficiency energy savings. Hiwave framed its offering around three pillars — "fast, safe, economical" — aimed at rapid deployment, stable operation, and whole-lifecycle cost optimization for computing infrastructure. On the exhibition floor, Hiwave displayed its AIDC full-scenario solution through overall architecture and multi-type equipment models, highlighting compact dry coolers, high-temperature magnetic levitation chillers, and liquid cooling CDUs, covering natural cold source utilization, liquid cooling heat exchange, and precise terminal temperature control. Hiwave said it can provide differentiated system configurations tailored to regional climate conditions, water resource availability, and project requirements. ### Key figures - Event: 25th HVAC&R Academic Annual Meeting, opened October 28, Guiyang. - Attendance: 30 regional societies and over 1,000 industry participants. - Deployment: a 50-rack liquid cooling module completed in 28 days. - Construction cycle: shortened by 60% versus traditional models. - Maintenance: single CDU replacement time under 5 minutes, with whole-rack online maintenance capability. - Measured PUE: 1.15 in relevant project tests. - Next-generation architecture referenced: Vera Rubin high-density computing. ### Why it matters to ebm-papst Hiwave is positioning itself as a system-level cooling integrator for AI factories, combining modular prefabrication, CDU-based liquid cooling, dry coolers, and magnetic levitation chillers. This is a competitive signal in the fast-growing AIDC cooling space, where fan and air-movement content is increasingly bundled into integrated thermal systems rather than sold as standalone components. Assessment (inference): Hiwave's emphasis on air-liquid hybrid configurations ("wind-liquid same source," flexible air/liquid configuration) suggests continued demand for high-efficiency fans and blowers at the air-side and terminal heat-exchange stages, representing a potential customer opportunity for ebm-papst if it can engage early in Hiwave's system design cycles. Conversely, as integrators like Hiwave build full-stack portfolios and deepen modular prefabrication, they may consolidate supplier choices and increase price and specification pressure on component vendors. The explicit reference to Vera Rubin-class high-density racks signals that liquid cooling adoption is accelerating, which could reduce per-rack air-movement content over time; ebm-papst should monitor how much air-side cooling remains in hybrid designs and position its high-static-pressure, high-efficiency fan lines accordingly. The disclosed PUE of 1.15 also raises the efficiency bar for all subsystem suppliers.

## Full text (English translation)

On October 28, the 25th HVAC&R Academic Annual Meeting opened in Guiyang. As an important industry-academia-research-application exchange platform in the HVAC&R field, this year's annual meeting gathered 30 regional societies and more than 1,000 industry colleagues to jointly discuss technology innovation and industry development directions.

Hiwave appeared at this annual meeting with its full-scenario AIDC data center solutions. Zhu Haolin, Director of Hiwave's Marketing Center, delivered a keynote speech titled "Data Center Cooling Solutions for the Next-Generation AI Factory," sharing Hiwave's technical practices in modular prefabrication, liquid cooling system reliability, and high-efficiency energy savings around the development trends of AI computing infrastructure.

I. In the AI Factory era, what new challenges does data center cooling face?

With the rapid development of AI large models and high-density computing, data centers are evolving from traditional resource-bearing platforms to AI Factories centered on computing production.

As computing scale continues to grow and rack power density keeps rising, higher requirements are placed on the delivery efficiency, operational reliability, and energy utilization efficiency of cooling systems.

In his speech, Zhu Haolin pointed out that customers' core demand can be summarized as: spend the least money to produce more tokens.

Around this goal, Hiwave proposed a next-generation data center cooling solution centered on "fast, safe, economical," promoting rapid deployment, stable operation, and whole-lifecycle cost optimization of computing infrastructure.

Fast: modular prefabrication accelerating computing deployment

Traditional data center construction involves multiple professional systems such as cold sources, IT, power distribution, and water treatment, with long on-site construction cycles and complex coordination.

Through full modular prefabrication, Hiwave completes prefabrication, testing, and pre-installation of each system in the factory, realizing a shift from on-site engineering construction to productized delivery.

In project practice, a 50-rack liquid cooling module was deployed in only 28 days, shortening the construction cycle by 60% compared with traditional models, helping customers accelerate the commissioning of computing infrastructure.

Safe: building a reliable liquid cooling system to ensure business continuity

Facing the challenges of liquid cooling operation in high-density computing scenarios, Hiwave has built a liquid cooling system reliability assurance system around key aspects such as redundant design of CDU systems, water-electricity isolation, precision fluid replenishment, rapid replacement, and full-link monitoring.

Through modular design and online maintenance capability of key components, whole-rack online maintenance is achieved, with single CDU replacement time of less than 5 minutes, reducing the impact of system maintenance on business operations.

Economical: system-level energy efficiency optimization to reduce whole-lifecycle costs

Cooling systems are an important part of data center energy consumption. Hiwave continuously optimizes system operating efficiency through air-liquid same-source, distributed multi-cold-source coordination, and AI-assisted intelligent operations and maintenance.

The measured PUE of relevant projects reaches 1.15.

At the same time, for next-generation high-density computing architectures such as Vera Rubin, Hiwave supports flexible air-liquid configuration and smooth evolution, reducing repeated system investment and balancing current deployment needs with future computing upgrades.

From delivery efficiency and system reliability to energy utilization, Hiwave uses systems engineering thinking to promote the coordinated development of cooling technology and AI computing infrastructure.

II. Full-scenario AIDC solutions showcased, demonstrating air-liquid fusion technology strength

At the annual meeting exhibition area, Hiwave concentrated on displaying its full-scenario AIDC data center solutions, presenting system-level cooling capability from the cold source side to the machine room terminal through overall architecture and multi-type equipment models.

The site focused on displaying key products such as compact dry coolers, high-temperature magnetic levitation chillers, and liquid cooling CDUs, covering core links such as natural cold source utilization, liquid cooling heat exchange, and precise terminal temperature control.

Facing climate conditions, water resource conditions, and project construction needs in different regions, Hiwave can provide differentiated system configurations, promoting coordinated optimization of cooling systems among deployment efficiency, operational reliability, and energy-saving performance.

III. Driving high-quality development of next-generation data centers through system-level innovation

The evolution of AI computing infrastructure is not only an upgrade of computing power but also a systemic transformation of energy utilization, thermal management, and engineering delivery models.

From modular prefabrication to full-stack liquid cooling, from efficient cold sources to intelligent operations and maintenance, Hiwave continues to deepen data center cooling technology R&D and product innovation, building AIDC solutions covering multiple scenarios around customers' core needs for efficient deployment, stable operation, and energy-saving cost reduction.

In the future, Hiwave will continue to promote deep coordination between cooling systems and AI infrastructure, helping build next-generation AI Factories with more reliable, efficient, and flexible solutions.

## Full text (original)

10月28日，第二十五届暖通空调制冷学术年会在贵阳开幕。 作为暖通空调制冷领域重要的产学研用交流平台，本届年会汇聚全国30个地方学会及千余名行业同仁，共同探讨行业技术创新与产业发展方向。
海悟携AIDC数据中心全场景解决方案亮相本届年会。海悟市场营销中心总监朱浩林发表《面向下一代AI Factory的数据中心制冷解决方案》主题演讲，围绕AI算力基础设施的发展趋势，分享海悟在模块化预制、液冷系统可靠性及高效节能等方面的技术实践。
一、AI Factory时代，数据中心制冷面临哪些新挑战？
随着AI大模型与高密度算力快速发展，数据中心正从传统的资源承载平台，向以算力生产为核心的AI Factory演进。
算力规模持续增长，机柜功率密度不断提升，对制冷系统的交付效率、运行可靠性和能源利用效率提出了更高要求。
朱浩林在演讲中指出，客户的核心诉求可以概括为：花最少的钱，生产更多的Token。
围绕这一目标，海悟提出以“快、安、省”为核心的下一代数据中心制冷解决方案，推动算力基础设施实现快速部署、稳定运行与全生命周期成本优化。
快：模块化预制，加速算力部署
传统数据中心建设涉及冷源、IT、配电、水处理等多个专业系统，现场施工周期长、协同复杂。
海悟通过全模块化预制，将各系统在工厂完成预制、测试与预装，实现从现场工程建设向产品化交付转变。
在项目实践中，50柜液冷模块仅用28天完成部署，建设周期较传统模式缩短60%，帮助客户加快算力基础设施投产。
安：构建可靠液冷体系，保障业务连续性
面对高密度算力场景下的液冷运行挑战，海悟围绕CDU系统的冗余设计、水电隔离、精密补液、快速更换与全链路监控等关键环节，构建液冷系统可靠性保障体系。
通过模块化设计与关键部件在线维护能力，实现整柜在线维护，单台CDU更换时间小于5分钟，降低系统维护对业务运行的影响。
省：系统级能效优化，降低全生命周期成本
制冷系统是数据中心能源消耗的重要组成部分。海悟通过风液同源、分布式多冷源协同及AI辅助智能运维，持续优化系统运行效率。
相关项目实测PUE达到1.15。
同时，针对Vera Rubin等下一代高密度算力架构，海悟支持风液灵活配置与平滑演进，降低系统重复投资，兼顾当前部署需求与未来算力升级。
从交付效率、系统可靠性到能源利用，海悟以系统工程思维推动制冷技术与AI算力基础设施协同发展。
二、AIDC全场景解决方案亮相，展现风液融合技术实力
在年会展区，海悟集中展示AIDC数据中心全场景解决方案，通过整体架构及多类型设备模型，呈现从冷源侧到机房末端的系统级制冷能力。
现场重点展示集约型干冷器、高温磁悬浮冷机、液冷CDU等关键产品，覆盖自然冷源利用、液冷换热及末端精准控温等核心环节。
面向不同地域的气候条件、水资源状况及项目建设需求，海悟能够提供差异化系统配置，推动制冷系统在部署效率、运行可靠性与节能表现之间实现协同优化。
三、以系统级创新，推动下一代数据中心高质量发展
AI算力基础设施的演进，不仅是计算能力的升级，更是能源利用、热管理与工程交付模式的系统性变革。
从模块化预制到全栈液冷，从高效冷源到智能运维，海悟持续深化数据中心制冷技术研发与产品创新，围绕客户高效部署、稳定运行与节能降本的核心需求，构建覆盖多场景的AIDC解决方案。
未来，海悟将继续推动制冷系统与AI基础设施深度协同，以更可靠、高效、灵活的解决方案，助力下一代AI Factory建设。
