大金发布iCM PRO智能冷机管理平台,支持最多16台机组

Daikin launches iCM PRO chiller manager, linking up to 16 third-party units per controller from Nov 2026
聚合·DaikinT22026-10-28 · INTL · Daikin 大金
新品技术发布商用暖通节能改造
▾ 1 条同事件报道

情报详报

What happened Daikin has announced the launch of iCM PRO, a next-generation version of its intelligent Chiller Manager platform, available from 1 November 2026. The system is positioned as an HVAC plant management platform that integrates Daikin equipment together with compatible third-party chillers and heat pumps under a single control strategy, supporting up to 16 units per controller. iCM PRO comes in four configurations covering 4, 8, 12 or 16 chillers and heat pumps, with datapoint capacities ranging from 500 to 5,000. It targets both new installations and retrofit projects, and is designed so that existing equipment can remain integrated. A pre-configured control architecture built on proprietary Daikin software is intended to simplify commissioning and cut on-site configuration effort. The platform covers air-cooled and water-cooled chillers, heat pumps and multifunctional units, including two-pipe and four-pipe systems, simultaneous heating and cooling, and seasonal changeover applications. It also coordinates plant auxiliaries such as pumps, cooling towers and control valves. Compatible Daikin equipment includes the EWYT-CZ, EWYE-CZ, EWAT-CZ, EWYT-B, EWYK-QZ and VZ series, plus the DWSC, DWDC and EWW(D)(H)(S)-DZ centrifugal chiller ranges. Developed by Daikin Applied Europe, iCM PRO uses a two-level software architecture that combines validated Daikin control algorithms with a customisation layer based on Niagara technology, allowing operating logic, configurations and functionality to be adapted to individual project requirements while retaining the validated control layer. The platform adds flow-based sequencing alongside traditional temperature-based control, monitoring unit availability, alarms, operating priorities, running hours, start frequency and plant thermal demand to adjust equipment operation. By factoring hydraulic demand into sequencing decisions, it is aimed at variable-flow installations, primary-secondary configurations, multi-zone buildings and industrial processes with dynamic loads. ### Key figures - Availability date: 1 November 2026 - Maximum units per controller: 16 chillers and heat pumps - Configurations: four (4, 8, 12 or 16 units) - Datapoint capacity range: 500 to 5,000 - Software architecture: two levels (validated Daikin control algorithms plus a Niagara-based customisation layer) - No pricing, production volume or sales target figures disclosed. ### Why it matters to ebm-papst This is a controls-layer move by a major chiller OEM, and it matters to ebm-papst mainly as a market signal about where plant-level integration is heading. By explicitly supporting third-party chillers and heat pumps and by building on Niagara technology, Daikin is positioning iCM PRO as an open, retrofit-friendly supervisory layer rather than a closed Daikin-only controller. That raises the bar for interoperability expectations among consultants and building owners specifying HVAC plant. Assessment (inference): For ebm-papst, the most direct relevance is not the chiller controller itself but the fan and auxiliary side of the plant. iCM PRO coordinates pumps, cooling towers and control valves, and its flow-based sequencing logic is designed around variable-flow installations and dynamic thermal demand. Those are exactly the operating regimes in which EC fan technology and demand-based airflow control deliver their efficiency advantage, so a platform that sequences on hydraulic demand could strengthen the case for intelligent, bus-connected fans and for fan-level data being exposed to the supervisory layer. Assessment (inference): There is also a competitive-adjacent risk. If Daikin's Niagara-based layer becomes a de facto integration point in European plant rooms, third-party equipment that cannot expose its operating data cleanly may be sequenced suboptimally or excluded from optimisation logic. ebm-papst should treat this as a prompt to confirm that its fan and motor interfaces, protocols and data models map readily onto Niagara-based supervisory platforms, and to track whether Daikin Applied Europe extends iCM PRO beyond chillers into air-handling and ventilation plant, where the overlap with ebm-papst's core business would be more direct.

原文全文

Daikin has announced the launch of iCM PRO, a new generation of its intelligent Chiller Manager platform, available from 1 November 2026. The system expands HVAC plant management capabilities by integrating Daikin equipment and compatible third-party chillers and heat pumps within a single control strategy, supporting up to 16 units per controller. iCM PRO is available in four configurations supporting 4, 8, 12 or 16 chillers and heat pumps, with datapoint capacities ranging from 500 to 5,000. The platform is designed for new installations and retrofit projects, allowing existing equipment to remain integrated. Pre-configured control architecture using proprietary Daikin software is intended to simplify commissioning and reduce on-site configuration. The platform supports air-cooled and water-cooled chillers, heat pumps and multifunctional units, including two-pipe and four-pipe systems, simultaneous heating and cooling, and seasonal changeover applications. It also coordinates plant auxiliaries such as pumps, cooling towers and control valves. Compatible Daikin equipment includes the EWYT-CZ, EWYE-CZ, EWAT-CZ, EWYT-B, EWYK-QZ and VZ series, alongside DWSC, DWDC and EWW(D)(H)(S)-DZ centrifugal chiller ranges. Developed by Daikin Applied Europe, iCM PRO uses a two-level software architecture combining validated Daikin control algorithms with a customisation layer based on Niagara technology. This allows operating logic, configurations and functionality to be adapted to individual project requirements while retaining the validated control layer. The platform introduces flow-based sequencing alongside traditional temperature-based control. It monitors unit availability, alarms, operating priorities, running hours, start frequency and plant thermal demand to adjust equipment operation. By incorporating hydraulic demand into sequencing decisions, the system is designed to support variable-flow installations, primary-secondary configurations, multi-zone buildings and industrial processes with dynamic loads.