风液协同・弹性解耦|海悟机房液冷方案支撑GW级智算集群低碳建设

Hiwave launches air-liquid hybrid cooling solution targeting GW-scale AI compute clusters with sub-90-day build cycles
海悟科技新闻T12026-10-19 · CN · 海悟科技 Hiwave
数据中心/IT散热新品技术发布

情报详报

What happened Hiwave, a Chinese data center infrastructure and liquid cooling specialist, published a solution positioning piece on 19 October 2026 outlining its machine-room liquid cooling portfolio for AI-era compute facilities. The company frames the shift from MW-scale to GW-scale compute clusters — driven by high-density GPU and NPU deployment with single-rack power approaching the hundred-kilowatt level — as a systemic challenge that single-component optimization can no longer address. Hiwave's answer is an integrated, system-engineering-led liquid cooling solution built on four principles it names as compatibility, elasticity, decoupling and efficiency. The architecture combines three elements: an air-liquid hybrid design that bridges air-cooled and liquid-cooled systems so a single facility can serve racks of differing power density; a prefabricated, modular construction model in which electromechanical systems are integrated in-factory and assembled on site; and a distributed decoupled architecture separating cold source, power distribution and IT load to reduce single-point-failure risk and allow phased expansion. For racks at 50 kW and above, the company positions cold-plate liquid cooling and near-end cooling as the core technologies, claiming these break through the ceiling of conventional air cooling while lowering cooling energy consumption and improving PUE. Hiwave situates the offering in the context of China's dual-carbon strategy and the East Data West Computing program, and states it will continue investing in liquid cooling and full-chain system engineering. ### Key figures - Single-rack power density addressed: 50 kW and above for the cold-plate liquid cooling and near-end cooling scenarios. - Construction cycle: compressed from a traditional several-hundred-day schedule to within 90 days, per Hiwave's prefabricated modular approach. - Cluster scale framing: the industry is described as moving from MW-level to GW-level compute clusters; single-rack power is described as trending toward the hundred-kilowatt level. - No specific figures disclosed for revenue, production capacity, market share, order volume, customer names, PUE values achieved, or investment amounts. ### Why it matters to ebm-papst Hiwave is explicitly positioning itself as a system-level integrator rather than a component vendor, and its air-liquid hybrid architecture is the commercially significant detail: a hybrid design keeps air-cooling infrastructure — and therefore fan content — inside high-density AI halls, whereas a pure liquid cooling path would displace air movers from the thermal chain. For ebm-papst this is a mixed signal. On the opportunity side, hybrid and near-end cooling schemes still require high-efficiency, high-static-pressure fans and EC motor platforms for the air-side loop, rear-door and near-end heat exchangers, and the modular prefabrication model creates repeatable, standardized fan demand that suits ebm-papst's product portfolio. On the threat side, a Chinese integrator building in-house system architecture and factory-prefabricated skids may specify local fan suppliers, compressing the addressable content per rack as liquid cooling takes a larger share of the heat load. Assessment (inference): Hiwave's emphasis on decoupling and phased build-out implies that cooling capacity will be procured in increments rather than as a single large order, which favors suppliers able to serve small, repeated, standardized module shipments with short lead times — a supply-chain profile where European component makers can compete on reliability and efficiency but may be pressured on price. Assessment (inference): the 90-day delivery claim, if credible, sets a delivery-speed benchmark that will propagate to sub-suppliers, making short lead times and local inventory a de facto qualification criterion for fan vendors in this segment. Assessment (inference): ebm-papst should treat GW-scale Chinese AI cluster projects as a specification-shaping battleground — engaging early with integrators on air-side efficiency and acoustic requirements for hybrid architectures is likely more valuable than competing purely on unit cost.

原文全文

原文 英文翻译
AI 产业化浪潮奔涌而来,人工智能正从实验室模型走向千行百业的实体落地,数字经济的底层逻辑正在被算力重新定义。算力中心不再只是简单的机房载体,而是驱动新质生产力的核心载体,是数字时代的 “AI 生产工厂”。算力集群规模由 MW 级向 GW 级跨越,算力形态从通用计算向通算、智算融合方向演进,高密度 GPU、NPU 大规模应用,单机柜功率迈向百千瓦级别,给传统数据中心基础设施带来多重系统性考验。 高热密度散热瓶颈、日益严苛的 PUE 低碳管控要求、IT 设备与基建生命周期错配、算力业务的不确定性,多重难题叠加,倒逼数据中心制冷体系、建设模式、系统架构迎来颠覆性变革。单一设备的优化已经难以应对 AI 时代的复杂挑战,唯有具备系统工程能力的一体化解决方案,方能支撑大规模算力平稳落地。 依托深厚的液冷核心技术沉淀与算力基础设施系统工程能力,海悟在风液同源、模块化部署、全生命周期协同运行领域持续深耕,打造面向 AI 时代的机房液冷解决方案,以兼容、弹性、解耦与高效四大核心理念,破解高密度算力建设痛点,助力数字基础设施低碳转型,服务双碳战略与东数西算工程,践行绿色发展的社会责任。 风液融合架构,兼容多元算力,守护投资价值 智算场景算力负载差异巨大,高低功率设备并存。海悟风液融合架构,打通风冷与液冷两套体系,可灵活适配不同功率密度机柜,兼顾通用算力与 AI 算力的差异化散热需求。面对芯片迭代、业务负载波动等不确定因素,风液融合方案保障系统长期稳定运行,支持算力平滑升级,保护客户前期投资,实现算力基础设施可持续演进。 预制化模块化,重构工程模式,加速算力落地 GW 级算力集群建设,对交付速度提出极高要求。海悟坚持工程产品化思路,将机电系统高度集成,采用工厂预制 + 现场拼装的建设模式,把传统数百天的建设周期压缩至 90 天以内。模块化方案支持分期建设、按需扩容,跟随算力规模跃迁节奏分步落地,实现标准化快速复制,大幅降低现场施工复杂度,高效支撑大规模算力中心建设。 分布式解耦架构,增强系统韧性,实现按需扩容 传统集中式架构易出现单点故障,且扩容改造难度大。海悟机房液冷解决方案采用冷源、配电、IT 负载分布式解耦设计,有效降低单点故障带来的连锁风险,提升算力基础设施的可靠性。解耦架构打破基础设施一次性建设固化的局限,支持算力分期部署、按需扩展,从容应对 IT 硬件快速迭代,弥合设备与基建生命周期错配难题。 规模化液冷落地,突破散热极限,践行低碳发展 针对单机柜 50kW 及以上超高密度算力场景,海悟以冷板液冷、近端制冷技术为核心,突破传统风冷散热上限,高效带走高功率芯片产生的热量。液冷方案大幅降低制冷能耗,持续优化 PUE,在支撑海量算力稳定输出的同时,有效控制数据中心碳排放,平衡算力扩张与生态保护,推动算力产业绿色可持续发展。 当下,AI 产业竞争已经从算法、数据层面,延伸到底层算力基础设施的比拼。算力底座的能效、弹性、可靠性,决定着人工智能产业规模化发展的上限。面向数字经济长远发展,海悟将持续深耕算力基础设施与液冷技术创新,发挥全链条系统工程优势,持续打造高效、低碳、可规模化复制的数据中心产品体系。以绿色算力底座赋能各行各业数字化转型,助力我国数字基础设施高质量建设,为新质生产力发展注入持久动力。