海悟推出高可靠智能液冷分配单元CDU,破解液冷规模化落地三大痛点

Hiwave launches high-reliability CDU targeting liquid-cooling scale-up pain points in AI data centers
海悟科技新闻T12026-10-21 · CN · 海悟科技 Hiwave
新品技术发布数据中心/IT散热

情报详报

What happened Hiwave, a China-based data center thermal management specialist, published a product position paper on 21 October 2026 introducing its liquid-cooling distribution unit (CDU) aimed at the scale-out phase of intelligent computing centers. The company frames the industry transition as moving from "pilot demonstration" to "scale replication," and argues that project bottlenecks are no longer about raw heat-dissipation capacity but about the reliability, safety and O&M efficiency of the core distribution unit. Hiwave positions the CDU as the combined "power hub, safety gate and intelligent brain" of a cold-plate liquid-cooling loop, and describes three functional roles: driving coolant circulation between the cold source and rack cold plates, transferring heat through a plate heat exchanger while physically isolating facility-side and server-side hydraulic loops, and monitoring temperature, flow and pressure across the full chain to match rack load dynamically. The announcement details three design pillars. First, leak containment: physical separation of coolant and electrical compartments, IP66 enclosure rating, 316L stainless steel flow paths with PTFE seals rated for pH 2–12 and corrosion rates below 0.001 mm/year, a 50 μm pre-filter with differential-pressure monitoring at ±5% blockage-warning accuracy, plus a three-tier millisecond leak-response scheme (100 ms automatic shut-off on pressure transients, conductivity monitoring at ±0.1 μS/cm, and a mechanical drip detector with 0.1 mL/min sensitivity). Second, redundancy: dual-bus power with under-10 ms failover, parameter retention on power loss, IEC 61000-4-11 compliance, full N+1 redundancy on pumps and sensors with under-500 ms switchover, blind-mate hot-swappable pumps and power modules replaceable in under 5 minutes without downtime, and a modular architecture for scaling heat-transfer capacity and flow. Third, AI control: an intelligent fluid-replenishment module holding level fluctuation within ±3% versus ±10% conventionally (claimed 90% reduction in manual intervention), AI-based dynamic hydraulic balancing holding rack ΔT within ±1.5 °C to ASHRAE Class A precision, dew-point and pressure control, multi-CDU group control, and a predictive model using eight categories of component parameters (bearing vibration, temperature gradients) with claimed ≥95% fault-prediction accuracy and 48-hour advance warning. Hiwave targets urban cloud-brain nodes, edge distributed data centers, air-to-liquid retrofit projects and dense legacy machine-room upgrades, and frames the CDU as a domestically developed core component that lowers liquid-cooling solution cost and supports PUE reduction under the East Data West Computing program and dual-carbon goals. ### Key figures - IP66 enclosure protection rating for the CDU. - Flow-path material: 316L stainless steel with PTFE seals; rated for pH 2–12; corrosion rate below 0.001 mm/year. - Pre-filter accuracy: 50 μm; blockage-warning accuracy: ±5%. - Leak response: automatic shut-off within 100 ms on pressure transients; conductivity monitoring accuracy ±0.1 μS/cm; drip-detection sensitivity 0.1 mL/min. - Power redundancy: dual-bus design, seamless switchover under 10 ms; IEC 61000-4-11 EMC certification. - Component redundancy: full N+1 on pumps and sensors; switchover delay under 500 ms. - Maintenance: blind-mate replacement of pumps and power modules in under 5 minutes, no downtime. - Fluid level control: ±3% fluctuation versus ±10% for conventional systems; claimed 90% reduction in manual intervention. - Rack ΔT control: within ±1.5 °C, ASHRAE Class A. - Predictive maintenance: eight categories of monitored parameters; claimed ≥95% fault-prediction accuracy; 48-hour advance warning. - No pricing, production capacity, revenue or market-share figures disclosed. ### Why it matters to ebm-papst Hiwave's CDU messaging is a direct signal that Chinese liquid-cooling component vendors are competing on reliability, redundancy and intelligence rather than price alone — the same axes on which ebm-papst differentiates its fan and motor portfolio in data center thermal systems. The emphasis on N+1 pump redundancy, hot-swap maintenance and AI-driven dynamic balancing indicates that CDU vendors are increasingly specifying and integrating their own critical subcomponents, which could reduce the addressable content for external fan and blower suppliers in cold-plate loops, or conversely open opportunities where CDU makers need high-reliability air-movement and motor components for the facility-side heat rejection path (dry coolers, CDUs with integrated air-cooled heat exchangers). Assessment (inference): The explicit targeting of air-to-liquid retrofits and edge sites is the most relevant opening for ebm-papst, since those deployments still rely heavily on fan-driven heat rejection and compact air movement, and a domestic Chinese CDU pushing cost down could accelerate retrofit volume — a net positive for fan demand if ebm-papst is positioned on those bills of materials. Assessment (inference): The claim of breaking the technical barrier on high-end liquid-cooling core components should be read as a competitive signal in the China market specifically; ebm-papst should track whether Hiwave's CDU becomes a reference design that pulls through domestic fan suppliers alongside it. Assessment (inference): The absence of any disclosed capacity, pricing or customer commitments means the announcement is currently a capability claim rather than verified market traction, and should not yet be treated as a confirmed share shift.

原文全文

原文 英文翻译
当智算中心建设节奏从 “试点示范” 跨入 “规模复制” 阶段,冷板式液冷的应用堵点也逐渐清晰:很多项目并非输在散热能力,而是卡在核心分配单元的可靠性、安全性与运维效率上。CDU(液冷分配单元)作为整套液冷系统的 “动力枢纽 + 安全闸门 + 智能大脑”,直接决定了液冷方案能不能真正放心用、长期用、低成本用。海悟深耕数据中心温控领域多年,面向规模化液冷落地的真实行业痛点,打造高可靠、高智能、高适配的液冷分配单元 CDU,为高密度算力系统筑牢安全、高效、省心的动力换热中枢。 作为冷板式液冷系统的核心功能单元,海悟 CDU 承担着三大核心职责:一是作为动力中枢,驱动冷却液在冷源与机柜冷板间循环流动,把冷量精准输送到 CPU、GPU 等发热核心;二是作为换热枢纽,通过板式换热器实现冷热侧回路的热量传递与物理隔离,保障冷源侧与服务器侧的水力独立;三是作为监控中枢,全链路实时采集、调节冷却液温度、流量、压力等关键参数,动态匹配机柜负载变化,让整套液冷系统始终运行在最优能效区间。 把漏液焦虑从根源锁死,全链路安全防护让客户放心 行业对液冷最大的顾虑,始终是漏液导致服务器短路烧毁的风险。海悟 CDU 从结构设计、过程监测、主动响应三个层面搭建全维度漏液防护网: 从结构根源上,严格执行冷却液回路与电气腔室的物理分隔设计,整机达到 IP66 最高防护等级,冷却液在独立的密封流道内循环,从设计层面杜绝 “水渗入电路” 的可能性。流道整体采用 316L 不锈钢材质搭配 PTFE 耐腐密封,可耐受 PH 值 2-12 的宽范围介质环境,年腐蚀率低于 0.001mm,达到军工级防腐标准,适配全生命周期长期运行;前端配置 50μm 精度前置过滤器,搭配压差实时监测,堵塞预警精度 ±5%,主动拦截管路杂质,避免微通道冷板被堵损。 在过程防护上,搭建三重毫秒级漏液响应机制:管路压力突变时系统 100ms 内自动熔断切断,冷却液电导率实时在线监测精度达 ±0.1μS/cm,搭配灵敏度 0.1mL/min 的机械式滴漏捕获装置,实现从微量渗漏到突发故障的全场景覆盖,把漏液风险控制在萌芽阶段。 把停机风险降到零,全冗余架构保障业务连续运行 关键算力业务的连续运行,容不得一次核心部件故障。海悟 CDU 从供电、核心部件、运维流程全链路搭建无中断运行体系: 供电端采用双总线冗余设计,两路供电无缝切换时间小于 10ms,主控系统支持断电状态下参数自保持,通过 IEC 61000-4-11 电磁兼容认证,彻底杜绝瞬时电压波动、单路供电跳闸对系统的冲击;核心动力与感知端实现水泵、传感器全量 N+1 冗余配置,单台水泵或传感器故障时,备用部件自动切入运行,切换延迟小于 500ms,全程业务无感知。 运维层面实现真正的在线热维护:水泵、电源模块全部支持盲插式更换,单部件现场更换时长不超过 5 分钟,运维作业无需停机、不打断业务运行,彻底告别传统机房空调维护需要提前停业务窗口的痛点。整机采用模块化拼装设计,各功能部件可根据项目所需的换热功率、流量需求快速组合,灵活适配不同规模、不同工况的项目要求。 把运维复杂度打下来,AI 智控实现系统级能效最优 液冷系统不是装完就一劳永逸,动态调节能力直接决定长期能效。海悟 CDU 搭载智能控制大脑,把复杂的系统调节交给 AI 完成: 系统内置智能补液模块,将全工况下的冷却液液位波动控制在 ±3% 以内,相比传统液冷系统 ±10% 的液位波动幅度,运维人工干预量减少 90%,日常巡检、补液的工作量大幅降低。基于 AI 算法实现动态水力平衡,根据各机柜实时负载自动调节支路流量,将机柜进出水温差稳定控制在 ±1.5℃以内,达到 ASHRAE Class A 最高精度等级,避免局部过冷或过热造成的能源浪费;支持露点精准控制、压力动态稳定调节,搭配多机组智能群控功能,实现多 CDU 之间的冷源协同、故障自诊断、负载瞬态快速响应,整套系统能效自主寻优。 同时系统通过采集轴承振动、温度梯度等 8 类核心部件运行参数搭建 AI 预测模型,部件潜在故障预测准确率≥95%,把传统 “故障发生了再抢修” 的被动运维,升级为提前 48 小时预警的主动式运维,大幅降低突发故障概率。 海悟液冷分配单元 CDU 凭借高可靠、低运维、快适配的特性,可灵活覆盖多元场景需求:面向城市云脑这类承载关键政务、民生业务的核心算力节点,以零中断、高安全的特性保障业务连续运行;面向边缘分布式数据中心,以模块化、少运维的特性降低分散站点的管理成本;面向计划从风冷升级为液冷的存量项目,以高适配性兼容原有冷源系统,无需大规模土建改造即可完成散热升级;面向老旧高密机房改造场景,以紧凑化设计、快速部署能力解决机房空间紧张、改造窗口短的现实难题。 从产业价值来看,海悟 CDU 作为液冷系统的核心国产部件,以成熟可靠的性能打破高端液冷核心部件的技术壁垒,推动液冷整体方案成本持续下探,加速高密度液冷技术从高端试点走向规模化普及。在 “东数西算” 工程与双碳目标的指引下,海悟 CDU 以低流阻、高换热效率、动态能效寻优的特性,帮助数据中心持续压低 PUE,为西部自然冷源高效利用、东部高密度算力可靠部署提供核心动力支撑,助力千行百业的数字基础设施建设迈向绿色、高效、可持续的新阶段。