# Hiwave launches integrated skid-mounted outdoor cooling source combining air and liquid cooling for data centers

- Source: Hiwave News (T1)
- Published: 2026-10-27
- Score: 54.0
- Tags: Product launch, Datacenter, HVAC
- Companies: Hiwave
- Original: https://www.haiwu.com/news/dynamic/2176.html

## Intelligence brief

### What happened Hiwave, a data center thermal management solutions provider, announced a series of integrated cooling source products designed as standardized, factory-assembled, skid-mounted outdoor cooling units for data centers. The announcement was published on 2026-10-27 on the company's news channel. The product integrates into a single skid: enclosure shell, dry coil modules, closed spray wet coil modules, a high-efficiency spray system, circulating pumps and a full hydraulic module, variable-frequency drive fans, water distribution piping, a full-chain temperature and sensor network, an intelligent control unit and the electrical distribution system. The unit is structurally optimized for freeze protection, fouling resistance, UV resistance and snow-load resistance, and is positioned for continuous, stable modulating operation across all Chinese climate zones. A central design claim is "wind-liquid co-station": by combining fin-and-tube dry coolers and high-efficiency closed spray coils within one skid architecture and deploying them in distributed modular fashion, Hiwave says a single cooling source can serve both air-cooled and liquid-cooled heat rejection needs. Operators can configure the air-to-liquid ratio according to current IT load and later add modules to expand capacity as rack power density and liquid-cooling share rise, without acquiring new land or building a separate spray cooling station, and without disrupting live operations. The unit carries Hiwave's self-developed intelligent control system with an AI energy-saving optimization algorithm that collects outdoor temperature, humidity, solar irradiance and real-time IT load data, and automatically switches between free cooling via the dry coil section in transitional and winter seasons and spray-assisted heat exchange in hot seasons, without manual intervention. Hiwave positions the product for supercomputing centers, intelligent computing centers, integrated big data centers and urban cloud-brain facilities, and particularly as the outdoor heat rejection source for cold-plate liquid cooling systems, directly supplying stable circulating cooling water to CDUs. The company frames the offering as part of its end-to-end data center thermal chain, spanning room-level terminal air conditioners, liquid cooling CDUs and outdoor integrated cooling sources. ### Key figures - Full-year operating energy efficiency improvement of 15% versus conventional fixed-logic cooling source systems, as claimed by Hiwave. - Overall delivery cycle shortened by 75% versus conventional cooling station construction. - Conventional cooling station construction cited as typically requiring 3-6 months from site leveling and equipment lifting through piping welding, electrical wiring and commissioning. - Lower water consumption at equal cooling output versus conventional closed cooling tower solutions (no specific percentage disclosed). - No specific figures disclosed for unit capacity, pricing, production volume, order intake or market share. ### Why it matters to ebm-papst This is a competitive and customer signal in the data center cooling chain. Hiwave is vertically integrating the outdoor cooling source, and the integrated skid explicitly includes variable-frequency drive fans as a factory-assembled, factory-commissioned component. That means fan selection moves from the project site to the OEM's standardized bill of materials, which shifts the purchasing decision toward a single thermal solutions vendor rather than discrete component sourcing. Assessment (inference): The "wind-liquid co-station" concept is a demand signal for fans that must perform across a wide operating envelope, since the same fan array serves dry cooling in winter free-cooling mode and spray-assisted condensing in summer, with variable-frequency control and low noise and low power draw as priorities. Assessment (inference): Hiwave's emphasis on factory assembly, sealed testing and live commissioning before shipment raises the bar on component reliability and documentation, favoring suppliers that can support pre-qualification and standardized integration rather than project-by-project engineering. Assessment (inference): The 75% delivery-cycle compression claim, if it holds in practice, pressures competitors in the outdoor cooling source space and could accelerate adoption of skid-based architectures, expanding the addressable volume of EC fans per data center project while compressing per-unit engineering support requirements. Assessment (inference): Hiwave's positioning as a one-stop thermal chain vendor spanning terminal units, CDUs and outdoor cooling sources makes it a potential channel partner for fan supply as well as a competitor to established cooling source OEMs, and ebm-papst should track whether Hiwave specifies third-party fan brands or develops in-house fan capability.

## Full text (English translation)

All-climate adaptability with no blind spots, Hiwave integrated cooling source: a new paradigm for air-liquid combined outdoor data room heat dissipation

Traditional data center cooling source construction has long been a "patchwork engineering" exercise: one vendor for dry coolers, another for cooling towers, another for circulating pumps, and then a system integrator to stitch the control system together. Equipment parameters from different vendors match poorly, on-site piping welding work is heavy, system joint commissioning takes a long time, and the actual energy efficiency once running often falls short of design values. Facing problems such as freezing and blockage in severe northern winters, wind-blown sand and fouling outdoors in the northwest, UV aging from exposure in the south, and structural load-bearing under blizzard conditions, additional investment in protective retrofits is required. As intelligent computing centers and supercomputing center projects come online at an ever faster pace, this kind of "assembled cooling station" can no longer keep up with the core requirements of high-density computing scenarios: fast delivery, high reliability, scalability and low energy consumption. Hiwave confronts these industry pain points directly, launching a series of integrated cooling source products that turn the entire outdoor cooling source into a standardized industrial finished product, providing a fully assembled, worry-free, high-efficiency outdoor heat dissipation solution for the new generation of green data centers.

Hiwave's integrated cooling source is a skid-mounted outdoor cooling supply unit in which all components are assembled and the entire process is jointly commissioned inside the factory. The whole machine integrates the enclosure shell, dry coil modules, closed spray wet coil modules, a high-efficiency spray system, circulating pumps and a full hydraulic module, variable-frequency drive fans, water distribution piping, a full-chain temperature sensing and sensor network, an intelligent control unit and the electrical distribution system. The whole machine has undergone dedicated structural optimization and possesses freeze protection, fouling resistance, UV resistance and blizzard resistance, and can operate with continuous and stable modulation according to cooling demand under all types of meteorological conditions across the country; paired with Hiwave's self-developed intelligent control system, it optimizes operating parameters in real time to achieve precise matching of cooling output, wasting not a single kilowatt-hour of electricity and not consuming an extra drop of water.

Air-liquid co-station, one cooling source covering the full cycle of computing capacity expansion

Traditional data center construction often faces a real dilemma: when air-cooled racks are deployed initially, one air-cooled cooling source is built; when computing density is later upgraded to liquid cooling, another spray cooling station must be built on additional land, resulting in two systems, two sets of operations and maintenance, and two land investments, causing serious duplicated construction. Through rational heat exchange packing and flow field design, Hiwave's integrated cooling source integrates fin-and-tube dry coolers and high-efficiency closed spray coils within the same skid architecture, adopting distributed modular deployment to truly achieve the unification of air-cooled cooling sources and liquid-cooled cooling sources. Users can flexibly configure the air-to-liquid ratio according to the current computing scale; when rack power density later increases and the liquid cooling share grows, capacity can be expanded through module stacking without acquiring new land or building a separate cooling station, without affecting existing business operations throughout, fundamentally adapting to the smooth technology evolution of data centers from air cooling to liquid cooling.

Intelligent optimization, putting every bit of water and electricity to the best use

Energy consumption and water consumption on the cooling source side are long-term major items in data center operating costs. Compared with traditional closed cooling tower solutions, Hiwave's integrated cooling source achieves a lower heat exchange approach temperature and lower pump and fan power consumption through flow channel simulation optimization and full variable-frequency component configuration, consuming less water at the same cooling output. The whole machine carries an AI energy-saving optimization algorithm that collects dynamic data such as outdoor temperature and humidity, irradiance intensity and real-time room load in real time, and automatically switches to the most economical operating mode: in transitional seasons and winter it prioritizes the dry cooling section for zero-energy free cooling, and in high-temperature seasons it automatically starts spray to enhance heat exchange, with no manual intervention throughout. Compared with cooling source systems operating on traditional fixed logic, full-year operating energy efficiency is improved by 15%, continuously lowering data center PUE from the cooling source side while reducing water resource consumption.

Productized delivery, compressing the project cycle from "counted in quarters" to "counted in weeks"

Traditional cooling station construction, from site leveling, equipment lifting, piping welding and electrical wiring to final system joint commissioning and trial operation, often takes 3-6 months. For intelligent computing projects that must seize an online window, time cost is market competitiveness. Hiwave's integrated cooling source adopts a deeply productized design: all components are assembled, seal-tested and electrically commissioned in the factory, and on site only water pipe connection and cable connection are needed before commissioning, shortening the overall delivery cycle by 75% and greatly shortening customers' project online time. The control system supports three operating modes: fully automatic intelligent operation, local manual commissioning and remote mode switching. Operations and maintenance personnel do not need to frequently attend the outdoor cooling yard and can complete all parameter adjustments and mode switching from the central control room; the system comes with fault self-diagnosis for all components and status visualization, with automatic alarms for anomalies, greatly reducing later operations and maintenance workload.

With the characteristics of high integration, fast deployment and high reliability, Hiwave's integrated cooling source can be widely adapted to high heat density scenarios such as supercomputing centers, intelligent computing centers, integrated big data centers and urban cloud brains, and is especially suitable as the outdoor heat dissipation cooling source for cold-plate liquid cooling systems, directly providing stable circulating cooling water to the CDU and eliminating the duplicated investment of customers separately building outdoor dry coolers and cooling towers.

From the perspective of social value, the all-climate protection capability of Hiwave's integrated cooling source can adapt to different construction conditions ranging from severe cold and windy, sandy regions in the northwest to high-temperature, high-humidity, rainy and snowy regions in the south, stably supplying cooling 24/7 for critical computing businesses and ensuring the continuous, uninterrupted operation of urban government computing and supercomputing research tasks. From the perspective of low-carbon contribution, the whole machine maximizes the potential for utilizing natural cooling sources, and with a 15% energy efficiency improvement and lower water consumption performance, helps data centers reduce energy and water consumption across the entire life cycle, precisely responding to dual carbon construction requirements. From the perspective of digital economy empowerment, the characteristics of fast delivery and elastic expansion perfectly match the rhythm of intelligent computing projects of "phased construction, fast online", helping the efficient implementation of computing hub nodes under the "East Data West Computing" project, and providing solid and reliable outdoor cooling source support for the development of digital industries such as AI large models and high-performance computing.

As a service provider covering full-chain temperature control solutions for data centers, Hiwave continues to refine its product capabilities from room terminal air conditioners and liquid cooling distribution units (CDU) to outdoor integrated cooling sources, saving customers the trouble of multi-supplier integration and building a green and efficient new generation of computing infrastructure with one-stop solutions.

## Full text (original)

传统数据中心的冷源建设，长期以来都是一项 “拼凑式工程”：干冷器选一家、冷却塔找一家、循环水泵配一家、控制系统再找集成商拼接，不同厂家的设备参数匹配差、现场管路焊接工程量大、系统联调周期长，最后跑起来的实际能效往往比设计值打折扣。遇到北方严寒冬天怕冻堵、西北户外怕风沙污堵、南方暴晒紫外线老化、暴雪天结构承压等问题，还要额外投入做防护改造。随着智算中心、超算中心项目上线节奏越来越快，这种 “拼装式冷站” 已经跟不上高密度算力场景 “快交付、高可靠、能扩容、低能耗” 的核心需求。海悟直面行业痛点，推出系列一体化冷源产品，把整套室外冷源做成标准化工业成品，为新一代绿色数据中心提供整装、省心、高能效的室外散热解决方案。
海悟一体化冷源，是一套在工厂内完成全部件组装、全流程联调的撬装式室外供冷单元。整机集成壳体围护、干盘管模块、闭式喷淋湿盘管模块、高效喷淋系统、循环水泵与全套水力模块、变频传动风机、配水管路、全链路温感与传感网络、智能控制单元与配电系统。整机经过专项结构优化，具备防冻、防污、抗紫外线、抗暴雪能力，在全国各类气象条件下都能根据冷量需求连续稳定调节运行；搭配海悟自研智能控制系统，实时寻优运行参数，做到冷量精准匹配，不浪费一度电、不多耗一滴水。
风液共站，一套冷源覆盖全周期算力扩容
传统数据中心建设往往面临一个现实难题：初期上风冷机柜的时候建一套风冷冷源，后续算力密度升级要上液冷，又要额外征地建一套喷淋冷却站，两套系统、两套运维、两份占地投入，造成严重的重复建设。 海悟一体化冷源通过合理的换热填料与流场设计，把管翅式干冷器、高效闭式喷淋盘管整合在同一个撬装架构内，采用分布式模块化部署，真正实现风冷冷源与液冷冷源的合二为一。用户可以根据当前算力规模灵活配置风液比，后续机柜功率密度提升、液冷占比增大时，无需重新征地、新建独立冷站，即可通过模块叠加完成扩容，全程不影响现有业务运行，从根本上适配数据中心从风冷到液冷的平滑技术演进。
智能寻优，把每一分水电都用在刀刃上
冷源侧的能耗与水耗，是数据中心运营成本里的长期大头。对比传统闭式冷却塔方案，海悟一体化冷源通过流道仿真优化、变频部件全配，实现更低的换热逼近度与更低的泵耗、风耗，在同等冷量下耗水量更省。 整机搭载 AI 节能寻优算法，实时采集室外温湿度、辐照强度、机房实时负载等动态数据，自动切换最经济的运行模式：过渡季与冬季优先利用干冷段实现零能耗免费制冷，高温季自动启动喷淋强化换热，全程无需人工干预。相比传统固定逻辑运行的冷源系统，全年运行能效提升 15%，从冷源侧持续压低数据中心 PUE，同时减少水资源消耗。
产品化交付，把项目周期从 “按季度算” 压到 “按周算”
传统冷站建设，从场地平整、设备吊装、管路焊接、电气接线到最后系统联调试运行，动辄需要 3-6 个月，对于要抢上线窗口期的智算项目来说，时间成本就是市场竞争力。 海悟一体化冷源采用深度产品化设计，所有部件在工厂内完成组装、密封测试、带电联调，现场仅需完成水管对接、电缆连接即可投运，整体交付周期缩短 75%，帮客户大幅缩短项目上线时间。控制系统支持全自动智能运行、本地手动调试、远程模式切换三种操作模式，运维人员无需频繁值守户外冷场，在中控室即可完成全部参数调整与模式切换；系统自带全部件故障自诊断、状态可视化功能，异常自动报警，大幅降低后期运维工作量。
凭借高集成、快部署、高可靠的特性，海悟一体化冷源可广泛适配超算中心、智算中心、一体化大数据中心、城市云脑等高热密度场景，尤其适合作为冷板式液冷系统的室外端散热冷源，直接为 CDU 提供稳定的循环冷却水，省去客户单独建设室外干冷器、冷却塔的重复投入。
从社会价值看，海悟一体化冷源的全气候防护能力，可适配从西北严寒、多风沙区域到南方高温、高湿、多雨雪区域的不同建设条件，7×24 小时稳定为关键算力业务供冷，保障城市政务算力、超算科研任务的连续不间断运行。从低碳贡献看，整机最大化挖掘自然冷源利用潜力，以 15% 的能效提升、更低的水耗表现，帮助数据中心全生命周期降低能耗与水耗，精准响应双碳建设要求。从数字经济赋能看，快速交付、弹性扩容的特性，完美匹配智算项目 “分期建设、快速上线” 的节奏，助力 “东数西算” 工程下各算力枢纽节点高效落地，为 AI 大模型、高性能计算等数字产业发展提供坚实可靠的室外冷源支撑。
作为覆盖数据中心全链路温控解决方案的服务商，海悟从机房末端空调、液冷分配单元 CDU 到室外侧一体化冷源持续打磨产品能力，帮客户省去多供应商集成的麻烦，用一站式方案共建绿色高效的新一代算力基础设施。