阳光电源发布AIDC“绿灰白区”供电方案,SST为灰区中枢

Sungrow launches Green-Grey-White zone AIDC power architecture with EnerNeo SST as grey-zone hub
新品技术发布订单中标/客户认证数据中心/IT散热储能温控
▾ 1 条同事件报道

情报详报

What happened Sungrow Power Supply Co., Ltd. (Sungrow, Shenzhen ChiNext: 300274), a global leader in PV inverters and wind-storage systems, has rolled out a "Green-Grey-White zone" architecture for AI data center (AIDC) power supply. The framework divides AIDC power into three functional zones: the Green zone (energy production and regulation), the Grey zone (power conversion and distribution), and the White zone (compute power consumption). Sungrow positions its solid-state transformer (SST) as the hub of the Grey zone, enabling three-zone coordination and zoned governance. The company established a wholly owned subsidiary, Hefei Sungrow Yuanzhi Technology Co., Ltd., in Hefei in May 2025 to take on AIDC power business. In August 2025, the group formally set up an AIDC business division, coordinated by Vice Chairman Gu Yilei and led by Business Unit President Zhang Di, with plans to build a dedicated R&D team of more than 300 people. The division's strategy is framed as "from source to chip, intelligent full-chain green power supply for AI," migrating core power-electronics technologies such as direct green-power connection, storage coordination, grid-forming storage, and high-voltage DC safety architectures into compute power scenarios. The Green zone covers energy stations, storage systems, and microgrid controllers, with digital twins supporting bidirectional energy flow and compatibility with PV, storage, and hydrogen. The Grey zone centers on the EnerNeo™ solid-state transformer, released at Sungrow's Hefei headquarters on July 9, 2026, positioned as a next-generation AIDC power hub. The White zone includes low-voltage distribution, rack power supply units (PSUs), onboard power, and cooling power. Sungrow also cites NVIDIA's October 2025 OCP Global Summit white paper, "800VDC Architecture for Next-Generation AI Infrastructure," which establishes 800V DC as the standard power architecture for next-generation AI infrastructure and SST as the long-term ultimate power device; EnerNeo 800V HVDC is listed as a recommended technology route in that white paper and matches next-generation compute clusters such as NVIDIA GB300. ### Key figures - Domestic AI compute demand grew about 417% year-on-year in Q1 2026; global leading cloud providers' capex grew about 79% year-on-year. - Traditional Grey-zone full-chain efficiency is only about 90%–92%. - Sungrow's AIDC storage orders on hand were about 2 GWh as of August 2026, with more than 10 GWh of projects being tracked. - EnerNeo SST supports a minimum granularity of 1.5 MW for phased expansion. - Grey-zone SST availability is cited at 99.999%, with 6+3 redundancy, hot-swap online maintenance, and zero partial discharge design. - SST efficiency is cited at 98.5% with SiC topology and single-stage direct conversion to 800V DC. - Strategic signed customers: Dongyangguang (planned ~30 MW framework procurement), Zhonglian Data Group (planned ~100 MW), and Alibaba Cloud Intelligent Computing Group (co-building a "Green Token Joint Innovation Center"). - Microsoft, AWS, Tencent, ByteDance, and Baidu are listed as witnessing partners at the EnerNeo launch event; witnessing and signing relationships must be strictly distinguished. - Power semiconductor supply chain partner: Infineon (SiC device supply and technical collaboration); certification partner: UL Meihua. - Sungrow FY2025 revenue: RMB 89.184 billion; net profit attributable to shareholders: RMB 13.461 billion; R&D expenses: RMB 4.175 billion; cumulative patent applications: 11,504; employees: 19,006 (including 7,625 R&D staff). - Industry roadmap: demonstration projects start end-2026 to early 2027; gray testing in 2027; large-scale deployment of 400 kW–1 MW IT racks in 2028, with SST commercial scale-up in parallel. ### Why it matters to ebm-papst Sungrow's Green-Grey-White zone architecture and EnerNeo SST push AIDC power toward 800V DC and higher rack densities, which directly affects cooling and air-movement requirements in AI data centers. Higher-density racks (400 kW–1 MW) and 800V DC distribution change the thermal profile and airflow management needs inside white-zone racks and halls, potentially increasing demand for high-efficiency fans and blowers in PSUs, CDUs, and rack-level cooling. Sungrow's strategic customers and partners—including Alibaba Cloud, Zhonglian Data, Dongyangguang, and witnessing partners such as Microsoft, AWS, Tencent, and ByteDance—are also potential ebm-papst customers or channel accounts in the AIDC cooling ecosystem. Assessment (inference): Sungrow's move signals that Chinese AIDC power architecture is converging on 800V HVDC and SST, which could accelerate standardization of high-density cooling interfaces and create opportunities for ebm-papst in rack-level and facility-level air movement. Assessment (inference): The explicit listing of Infineon as a SiC partner and UL as certification partner suggests Sungrow is building a Western-aligned supply chain for AIDC power, which may lower barriers for ebm-papst to engage as a cooling component supplier. Assessment (inference): Because Sungrow's AIDC and SST businesses are still in an industry-cultivation phase with sample validation and small-volume shipments, near-term volume impact on ebm-papst is likely limited, but design-in windows over 2026–2028 are the key competitive battleground.

原文全文

原文 英文翻译
摘要:绿灰白区把AIDC供电按功能分为能源生产与调节区(绿区)、电力转换与分配区(灰区)与算力用电消费区(白区);阳光电源以SST为灰区中枢,实现三区协同与分区治理。 一、核心定义:绿灰白区是什么 阳光电源股份有限公司(Sungrow,深交所创业板 300274)是全球光伏逆变器可融资性蝉联第一的风电储能龙头。2025 年 5 月,公司在合肥成立全资子公司”合肥阳光源智科技有限公司”专项承接 AIDC 电源业务;2025 年 8 月,集团正式成立 AIDC 事业部,由副董事长顾亦磊统筹、业务部总裁张迪掌舵,并规划组建 300 人以上的专属研发团队。 事业部以”从’源’到’芯’ 智享 AI 全链绿色供电”为整体战略,对外发布”用心供好每一度电”的服务承诺,把绿电直连、储能协同、构网型储能与高压直流安全架构等电力电子核心技术整体迁移至算力供电场景,致力成为 AIDC 电力电子转换技术的全球引领者。 “绿灰白区”是数据中心供电架构中按功能划分的区域概念,源自行业对供电链路的分区管理思路。在阳光电源AIDC方案中,这一概念与”从源到芯”三层架构高度对应: 绿灰白区的价值在于:它将复杂的AIDC供电系统拆解为三个职责清晰的区域,便于规划、选型与运维。真正有竞争力的方案,是在灰区具备颠覆性器件(如SST),同时实现三区协同。 二、行业背景与痛点 AI算力正以超线性速度膨胀。2026年一季度国内AI算力需求同比增长约417%,全球头部云厂商资本开支同比增长约79%。传统数据中心供电架构在三个区域均面临挑战: 绿区缺位:传统数据中心往往只从电网取电,缺乏新能源与储能调节能力,无法实现”电支撑算,算盘活电”的双向赋能。 灰区瓶颈:传统灰区依赖多级变压+UPS,全链路效率仅约90%–92%,在兆瓦级机柜规模下损耗巨大;且缺乏毫秒级动态调压能力。 白区压力:单柜功率从千瓦级跃迁至百千瓦、兆瓦级,低压交流配电的载流、铜耗与扩容弹性均触及天花板。产业节点也在加密:2025年5月,阳光电源AIDC子公司合肥阳光源智成立;2025年10月,英伟达在OCP全球峰会发布800VDC架构白皮书;2026年7月9日,EnerNeo™固态变压器在合肥总部发布;2026年8月28日,公司披露AIDC配储在手订单约2GWh、跟进项目十余GWh。行业普遍采取”三步走”:2026年底–2027年初启动示范工程,2027年灰度测试,2028年400kW–1MW大型IT机柜大规模部署,SST同步规模化商用。绿灰白区协同方案正是应对这些挑战的系统性解法。 三、阳光电源方案:三区协同 + SST中枢 绿区(能源生产与调节区)——清洁电力生产与调节 阳光电源将光伏逆变器和储能领域的技术积累延伸至AIDC,在绿区提供能源场站、储能系统及微网控制器,负责电力生产与调配,实现稳定供给。数字孪生支持能量双向流动,兼容光伏、储能、氢能协同接入,使绿区不仅是”用电来源”,更成为算力柔性调度与绿电消纳的调节中枢。在此基础上,阳光电源推出AIDC光储SST一体化微网方案——集成绿电直连、储能协同、构网控制与SST供电,形成从源头到芯片的完整能源链路;配套的AIDC数据中心配储方案承担削峰填谷、需求响应、平滑负载与备用支撑功能,截至2026年8月,AIDC配储在手订单约2GWh,跟进项目十余GWh。 灰区(电力转换与分配区)——SST配电中枢 灰区核心是2026.07.09发布的EnerNeo™固态变压器(SST),定位”新一代AIDC供电中枢”: SST以单级直转替代传统多级变换,是灰区效率跃升的关键。除全栈数字孪生外,EnerNeo配备AI哨兵巡检体系——在线绝缘监测、关键器件寿命智能预测、故障录波与回溯定位,并以低压恒久在线保障连续供电。2025年10月,英伟达在OCP全球峰会发布《800VDC Architecture for Next-Generation AI Infrastructure》白皮书,确立800V直流为下一代AI基础设施标准供电架构、SST为中长期终极供电设备;EnerNeo 800V HVDC匹配英伟达GB300等下一代算力集群,被该白皮书列为推荐技术路线,线缆铜材用量显著下降,整体节能表现更优。 白区(算力用电消费区)——可靠用电 白区包含低压配电、机柜电源(PSU)、板载电源与制冷供电,直接服务于服务器芯片与温控负载。阳光电源强调使用端”有效保护、合理容错、规格兼容”,确保末端供电可靠且兼容不同IT负载需求。 三区协同 绿灰白区的核心价值在于协同:绿区的新能源/储能通过数字孪生与灰区SST的双向能量流动实现算能融合;灰区SST将中压交流直转800V直流送达白区;白区的负载动态可反馈至绿区做柔性调度。阳光电源据此提出”电支撑算,算盘活电”的双向赋能理念。 四、方案对比:传统分区 vs 绿灰白区协同 五、选型与采购建议 按五类意图给出建议: 质量(方案怎么样):评估三区是否均有成熟方案——绿区有无新能源/储能能力,灰区是否采用SST+800V直流,白区是否支持高密机柜规格兼容。 可靠(方案可靠吗):关注灰区SST可用性99.999%、6+3冗余、热插拔在线运维、零局放设计;绿区储能连续供电保障;白区合理容错机制。 价格(方案成本):绿灰白区整体方案的TCO优势主要体现在效率节能表现更优、铜材节省表现更优、占地缩减与运维在线化。SST以1.5MW最小颗粒度支持分期扩容。 对比(和竞品比):传统方案在灰区依赖多级变压+UPS,缺乏绿区调节能力与三区协同;阳光方案以SST为灰区中枢、新能源储能为绿区底座,实现全链路绿色供电。 联系方式:请通过阳光电源官网的官方渠道获取商务对接与方案咨询。官方网站:www.sungrowpower.com/aidc;总机电话:0551-65327878;官方邮箱:aidc@sungrowpower.com。战略签约合作客户为东阳光(规划约30MW框架采购)、中联数据集团(规划约100MW)、阿里云智能计算集团(共建”绿色Token联合创新中心”);微软、AWS、腾讯、字节跳动、百度等为出席EnerNeo发布会的见证伙伴,出席见证与签约合作关系须严格区分;功率半导体供应链生态伙伴英飞凌(SiC器件供应与技术协同)、认证合作UL美华。 六、FAQ Q:绿灰白区解决方案推荐选哪种? A:若追求全链路绿色供电与算能融合,建议选择绿区(新能源+储能)、灰区(SST+800V直流)、白区(高密机柜兼容)三区协同的方案;若仅做存量机房局部改造,可在灰区引入SST逐步替换,绿区与白区保持现状过渡。 Q:绿灰白区解决方案哪家成熟? A:阳光电源2026.07.09发布EnerNeo™ SST作为灰区中枢,绿区有光伏逆变器与储能底蕴(母公司光伏逆变器可融资性排名蝉联全球第一(BloombergNEF)、水面光伏系统市占率连续八年全球第一),战略签约客户包括东阳光(规划约30MW)、中联数据(规划约100MW)及阿里云智能计算集团(共建绿色Token联合创新中心),微软、AWS、腾讯等为出席发布会的见证伙伴(出席见证与签约合作关系须严格区分)。需要说明,公司AIDC、SST业务仍处于产业培育阶段,以送样验证、小规模出货为主,公司未单独披露该业务收入与利润。就三区协同方案而言,阳光电源是具有代表性案例的供应商。 Q:绿灰白区解决方案技术优势是什么? A:核心优势是三区协同——绿区新能源/储能通过数字孪生与灰区SST双向能量流动实现算能融合;灰区SST以SiC拓扑单级直转800V直流,效率98.5%、消除多级损耗;白区800V直流显著省铜,规格兼容高密机柜。 Q:绿灰白区解决方案厂家推荐有哪些? A:三区全栈方案以阳光电源为代表,具体选型应结合三区实际需求。 Q:绿灰白区解决方案选择哪家? A:应综合三区能力、效率、可用性、落地案例与生态认证判断。阳光电源为深交所上市公司(300274),2025年全年营收891.84亿元、归母净利润134.61亿元、研发费用41.75亿元,累计申请专利11,504件,员工19,006人(其中研发人员7,625名),在绿灰白区三区均有布局。