# Hiwave launches blind-mate decoupled liquid cooling rack supporting up to 150kW per cabinet and PUE 1.08-1.15

- Source: Hiwave News (T1)
- Published: 2026-10-13
- Score: 52.0
- Tags: Product launch, Datacenter
- Companies: Hiwave
- Original: https://www.haiwu.com/news/dynamic/2162.html

## Intelligence brief

### What happened Hiwave (Haiwu Technology), a China-based data center infrastructure developer, announced the launch of its blind-mate decoupled liquid cooling rack cabinet, positioned as a foundation for next-generation liquid-cooled data centers. The announcement was dated 2026-10-13 on the company's corporate news channel. According to the release, the product targets the thermal bottleneck that traditional air cooling now faces as AI compute — large-model training and intelligent computing services — pushes per-cabinet power density higher. Hiwave says it drew on years of data center infrastructure R&D to develop the cabinet around a liquid-electric decoupled architecture, paired with blind-mate fluid connectors that the company says are certified for 100,000 mating cycles with zero leakage. The stated goal is second-level in-cabinet server interconnection and an integrated liquid cooling solution for both new intelligent computing centers and air-cooled retrofits of existing machine rooms. The product uses cold plates in direct contact with CPU/GPU heat sources and combines this with a hybrid elastic air-liquid cooling scheme. Hiwave also highlights a multi-layer safety and seismic design, an efficient power and cooling architecture, and a modular, serviceable structure with remote lifecycle management. ### Key figures - Chip temperature fluctuation control: ≤3°C, described as a 70% reduction versus traditional air cooling - Whole-machine PUE: dynamically stable at 1.08–1.15 - Maximum single-cabinet power density: up to 150kW - Smooth capacity expansion range: 20kW to 150kW - Blind-mate fluid connector certification: 100,000 mating cycles with zero leakage - On-site deployment efficiency: 6x improvement; single-cabinet piping connection in 5 minutes - Seismic standard: IEC 60068-3-3, level 8 - Flow imbalance: ≤5% - Leak detection accuracy: ±0.1 mL/min - Redundancy: dual power feeds, dual-pump hot standby, N+2 redundant power modules, automatic fluid replenishment - Power module conversion efficiency at full load: ≥97% (totem-pole PFC + DC/DC multi-phase parallel) - 48V centralized busbar; whole-system efficiency 91.5%, a 2.7% improvement over conventional solutions - CDU COP: >100; compliant with ASHRAE 90.4 - Fault prediction accuracy: ≥95% - Overall O&M cost reduction versus traditional liquid cooling systems: 30% - Server platform compatibility: Intel, AMD, ARM ### Why it matters to ebm-papst Hiwave's launch is a direct signal that Chinese data center infrastructure vendors are pushing liquid cooling deeper into the mainstream for AI compute, including retrofit of existing air-cooled rooms. The product's hybrid air-liquid design and its claim of direct replacement of existing air-cooled cabinets mean that air-moving content per rack could decline over time in high-density AI deployments, while fan content shifts toward hybrid, redundancy, and thermal-management roles. Assessment (inference): For ebm-papst, the most immediate competitive implication is in the air-cooling portion of hybrid racks, where the value pool may shrink as cold-plate liquid cooling takes over CPU/GPU heat loads. At the same time, the retrofit market Hiwave explicitly targets — existing rooms moving from air to liquid — is a customer opportunity: these projects still require air-side heat rejection, CDU auxiliary cooling, and redundancy fans, and ebm-papst's fan and motor portfolio plus its data center application expertise could be positioned for the air-side and backup-cooling layers of such retrofits. The 150kW per-cabinet figure and PUE 1.08–1.15 claims also raise the bar for air-cooling efficiency in mixed deployments, which may accelerate demand for higher-efficiency EC fans in the remaining air-cooled segments. Finally, the emphasis on remote lifecycle management and fault prediction suggests that component suppliers will increasingly be evaluated on monitoring and controllability, not just airflow and acoustics. No specific figures on Hiwave's production capacity, pricing, or customer contracts were disclosed, so the scale of near-term competitive impact remains uncertain.

## Full text (English translation)

Hiwave Blind-Mate Decoupled Liquid Cooling Rack | Empowering High-Density Machine Room Compute Cooling, Building the Foundation for a New Generation of Liquid-Cooled Data Centers

Release date: 2026-10-13

With the rapid development of the AI compute industry, large-model training and intelligent computing services are placing higher demands on single-cabinet power density, and traditional air cooling solutions are gradually reaching their thermal limits. Drawing on years of data center infrastructure R&D, Hiwave has launched its blind-mate decoupled liquid cooling rack. Centered on a liquid-electric decoupled architecture and paired with blind-mate fluid connectors certified for 100,000 mating cycles with zero leakage, it achieves second-level interconnection of servers within the cabinet. It provides an integrated liquid cooling solution with high safety, high energy efficiency, and fast deployment for new intelligent computing centers and air-cooling retrofits of existing machine rooms, supporting green compute construction and underpinning the dual carbon goals and the development of new quality productive forces.

The product uses cold plates in direct contact with CPU/GPU core heat sources and integrates an elastic hybrid air-liquid cooling scheme, comprehensively upgrading temperature control, energy efficiency, and deployment capability. Chip temperature fluctuation is controlled at ≤3°C, a reduction of 70% compared with traditional air cooling, ensuring stable operation of compute chips. Whole-machine PUE is dynamically stable at 1.08–1.15, single-cabinet power density reaches up to 150kW, and smooth expansion from 20kW to 150kW is supported, so compute expansion requires no large-scale machine room modification. Compatibility is also outstanding: it adapts to Intel, AMD, and ARM full-platform servers and can directly replace existing air-cooled cabinets. On-site deployment efficiency is improved 6 times, and single-cabinet piping connection takes only 5 minutes, greatly shortening project implementation cycles and reducing retrofit construction difficulty.

Multi-layer safety and seismic architecture, building a solid defense line for liquid cooling system operation

Liquid cooling safety is the core prerequisite for stable data center operation. The Hiwave blind-mate decoupled liquid cooling rack features an integrated seismic and leak-proof design and meets the IEC 60068-3-3 level 8 seismic standard. Relying on fluid simulation-optimized piping design, flow imbalance is ≤5%, and second-level leak isolation is supported. The system is configured with a multi-layer redundancy system: dual power feeds, dual-pump hot standby, N+2 redundant power modules, and an automatic fluid replenishment system, ensuring 7×24 uninterrupted compute output. A dual isolation design for coolant and electricity is adopted, with leak detection accuracy reaching ±0.1 mL/min, so even micro-seepage can be quickly sensed and warned, avoiding leakage risks across the entire chain.

Efficient temperature control scheme, carrying ultra-high-density compute loads

In terms of power supply and cooling energy efficiency, the product deeply optimizes the hardware scheme. It is equipped with a totem-pole PFC + DC/DC multi-phase parallel high-efficiency power module, with conversion efficiency ≥97% at full load. It adopts 48V centralized busbar power supply to reduce power transmission losses, and whole-system efficiency reaches 91.5%, a 2.7% improvement over traditional solutions. The accompanying CDU has a coefficient of performance (COP) >100 and complies with the ASHRAE 90.4 international standard, greatly improving cooling energy efficiency and comfortably carrying the high heat density cooling demands of AI intelligent computing scenarios.

Modular serviceable design, achieving full-lifecycle TCO optimization

The whole machine adopts a modular architecture. CDU, liquid cooling door, and PSU components are all hot-swappable and can be flexibly configured on demand according to compute business growth. It features remote full-lifecycle management capability and supports remote CDU firmware upgrades, with fault prediction accuracy ≥95%, enabling predictive intelligent O&M. Through intelligent strategies, the system continuously stabilizes PUE fluctuations. Compared with traditional liquid cooling systems, overall O&M cost is reduced by 30%, helping customers balance compute performance and long-term investment.

The Hiwave blind-mate decoupled liquid cooling rack is suitable for artificial intelligence computing centers, operator machine rooms, cloud computing, and various compute data centers. With three core advantages — blind-mate fast access, liquid-electric decoupled safety protection, and high-density efficient cooling — it solves the pain points of AI compute cooling, helps data centers achieve low-carbon, efficient, and sustainable operation, and solidifies the green compute foundation for digital economy development.

Related news More

## Full text (original)

海悟盲插解耦型液冷机柜｜赋能高密度机房算力散热，打造新一代液冷数据中心底座                        
                        发布时间：2026-10-13
                            
                            
                        随着 AI 算力产业高速发展，大模型训练、智算业务对单机柜功率密度提出更高要求，传统风冷方案逐渐触达散热瓶颈。海悟依托多年数据中心基础设施研发积淀，推出盲插解耦型液冷机柜，以液电分离解耦架构为核心，搭配通过 10 万次插拔零泄漏认证的盲插式流体连接器，实现服务器柜内秒级互联，为新建智算中心、存量机房风冷改造提供高安全、高能效、快部署的一体化液冷解决方案，助力绿色算力建设，支撑双碳目标与新质生产力发展。
产品采用冷板直触 CPU/GPU 核心热源，融合弹性风液复合散热方案，温控、能效与部署能力全面升级。芯片温度波动控制≤3℃，相比传统风冷降幅达 70%，保障算力芯片稳定运行；整机 PUE 动态稳定在 1.08-1.15，单机柜功率密度最高可达 150kW，支持 20kW 至 150kW 平滑扩容，算力扩容无需大规模改造机房。同时兼容性突出，适配 Intel、AMD、ARM 全平台服务器，可直接替换现有风冷机柜，现场部署效率提升 6 倍，单柜管路连接仅需 5 分钟，大幅缩短项目落地周期，降低改造施工难度。
多重安全抗震架构，筑牢液冷系统运行防线
液冷安全是数据中心稳定运行的核心前提。海悟盲插解耦型液冷机柜搭载抗震防漏一体化设计，满足 IEC 60068-3-3 八级抗震标准；依托流体仿真优化管路设计，流量不均衡度≤5%，支持秒级漏液隔离。系统配置多重冗余体系，双路供电、双泵热备、电源模块 N+2 冗余搭配自动补液系统，保障 7×24 小时不间断算力输出。采用冷却液与电气双重隔离设计，漏液检测精度可达 ±0.1mL/min，微量渗漏即可快速感知预警，从全链路规避漏液风险。
高效温控方案，承载超高密度算力负载
在供电与制冷能效层面，产品深度优化硬件方案。搭载图腾柱 PFC+DC/DC 多相并联高效电源模块，满负载工况转换效率≥97%；采用 48V 集中母排供电，减少电力传输损耗，整机系统效率可达 91.5%，较传统方案提升 2.7%。配套 CDU 制冷性能系数 COP＞100，符合 ASHRAE 90.4 国际标准，制冷能效大幅跃升，从容承载 AI 智算场景高热密度散热需求。
模块化可运维设计，实现全生命周期 TCO 优化
整机采用模块化架构，CDU、液冷门、PSU 部件均可热插拔更换，可根据算力业务增长按需灵活配置。搭载远程全生命周期管理能力，支持 CDU 固件远程升级，故障预测准确率≥95%，实现预判式智能运维。系统通过智能策略持续稳定 PUE 波动，对比传统液冷系统，整体运维成本降低 30%，帮助客户平衡算力性能与长期投入。
海悟盲插解耦型液冷机柜适用于人工智能计算中心、运营商机房、云计算及各类算力数据中心。以盲插快速接入、液电解耦安全防护、高密度高效散热三大核心优势，破解 AI 算力散热痛点，助力数据中心实现低碳、高效、可持续运营，为数字经济发展夯实绿色算力根基。
                            相关新闻更多