海悟发布电冷算全链路协同架构方案,构筑绿色算力底座

Hiwave launches electricity-cooling-computing full-chain architecture for AI data centers with 800V HVDC and liquid cooling
海悟科技新闻T12026-10-10 · CN · 海悟科技 Hiwave
新品技术发布数据中心/IT散热商用暖通

情报详报

What happened Hiwave, a Chinese provider of liquid cooling and computing infrastructure systems, published a technical explainer on its "electricity-cooling-computing full-chain collaborative architecture" solution, dated 2026-10-10. The company states that as AI technology moves deeper into industrial deployment, physical computing capacity construction has entered an explosive phase, and new digital infrastructure must carry massive high-density computing loads while balancing operational stability, energy efficiency and low-carbon sustainability. Hiwave says the solution departs from the traditional approach of designing power supply, cooling and computing loads independently, and instead coordinates all three as one system. It combines air-liquid homologous (same-source) technology with prefabricated modular cabin deployment. On the power side, it follows the 800V high-voltage HVDC industry trend and supplies IT loads and the cooling system from the same source, shortening power transmission paths and reducing multi-stage conversion losses. On the cooling side, it integrates liquid cooling CDUs, primary/secondary piping and the power system in a single design. On the computing-load side, it builds a load-sensing mechanism to coordinate computing load, power and cooling, targeting millisecond-level GPU load fluctuations. Hiwave also describes a reliability redesign: layered cold storage buffering (secondary-side micro-buffer for 0-30 second computing surges, primary-side large cold storage unit for 30-120 second load fluctuations), intelligent PDUs that capture load-change signals at second-level speed from the electrical side, and high-speed control valves plus variable-frequency pumps across the full chain from CDU cabinet to cold source, with predictive algorithms matching cooling supply to computing load in real time. The company claims traditional cooling systems typically have 3-5 seconds of temperature-control lag, which can cause chip junction temperature runaway. On efficiency, Hiwave says the architecture optimizes power routing to cut conversion losses, supports flexible combinations of multiple cold sources to suit different Chinese regional climates and make use of natural cooling, extends equipment service life, simplifies O&M and improves overall project TCO. ### Key figures - 800V HVDC: the high-voltage direct current architecture Hiwave says it is following for same-source power supply to IT and cooling loads. - 3-5 seconds: the temperature-control lag Hiwave attributes to traditional cooling systems. - 0-30 seconds: short-duration computing load surges handled by the secondary-side micro-buffer. - 30-120 seconds: longer load fluctuations handled by the primary-side large cold storage unit. - Millisecond-level: the dynamic fluctuation characteristic of GPU computing loads cited by Hiwave. - Second-level: the speed at which intelligent PDUs are said to capture load-change signals. - No specific figures disclosed for investment amounts, production capacity, shipment volumes, market share or customer names. ### Why it matters to ebm-papst Hiwave is positioning itself as a system-level integrator for AI data center infrastructure, explicitly linking power, liquid cooling and computing load rather than selling standalone cooling equipment. For ebm-papst, this is a market signal that the air-moving and cooling value chain in AI data centers is being reorganized around full-chain architectures, where fan and blower selection may increasingly be driven by CDU, prefabricated cabin and predictive-control requirements rather than by component-level specifications alone. Assessment (inference): Hiwave's emphasis on variable-frequency pumps, high-speed control valves and predictive algorithms suggests growing demand for tightly integrated, dynamically controllable air- and liquid-moving subsystems; ebm-papst could face pressure if such integrators standardize on in-house or local fan and pump suppliers, but could also find customer opportunities by supplying high-efficiency, digitally controllable fans and blowers for CDUs, prefabricated modules and hybrid air-liquid cooling designs. Assessment (inference): the explicit 800V HVDC and natural-cooling angle indicates that Chinese AI data center projects may prioritize domestically integrated solutions, making early engagement with integrators such as Hiwave important for maintaining position in this fast-growing segment. Assessment (inference): the absence of disclosed volumes, customers or timelines means the immediate competitive threat cannot be quantified from this announcement alone.

原文全文

原文 英文翻译
电冷算全链协同架构方案解析,构筑绿色算力底座,赋能数字经济高质量发展 发布时间:2026-10-10 AI 技术加速向产业纵深落地,实体算力建设迎来爆发期,新型数字基础设施建设不仅要承载海量高密度算力需求,更要兼顾运行稳定、能效优化与低碳可持续发展,助力双碳目标落地,培育壮大新质生产力。 在液冷深度应用的新阶段,决定 AI 数据中心综合能力的早已不是单一设备性能,而是整套系统的协同调度能力与动态响应能力。依托多年液冷技术积淀与算力基础设施系统工程能力,海悟在风液同源、模块化预制部署、全生命周期协同运维等赛道持续深耕,沉淀大量前沿探索成果与落地案例。在此基础上,海悟推出电冷算全链路协同架构方案,跳出传统 “供电、制冷、算力负载独立设计” 的建设思路,以系统思维统筹电、冷、算三大核心环节,打造稳定、高效、低碳、可规模化复制的 AI 算力基础设施底座,助力数字经济绿色发展。 系统协同:由设备独立走向全链联动,释放一体化架构价值 随着 800V 高压 HVDC 与液冷技术融合落地,供电、制冷、算力负载各自为战的传统模式,难以适配高密度 GPU 算力集群建设需求。海悟电冷算全链路协同架构,融合风液同源技术与预制化方舱方案,真正实现方案工程化落地与规模化复制。 在供电侧,紧跟 800V HVDC 行业发展趋势,实现 IT 负载与制冷系统同源供电,缩短电能传输链路,减少多级能量转换损耗,简化整体配电架构;在制冷侧,完成液冷 CDU、一次 / 二次侧管路与供电系统一体化协同设计,电气系统与液冷系统深度适配;在算力负载侧,针对 GPU 算力毫秒级动态波动特性,搭建负载感知机制,实现算力负载、供电、制冷三者联动调度,彻底打破设备孤岛。 可靠性重构:从被动故障保障升级为主动预判控制 AI 算力负载具备毫秒级剧烈波动特征,传统制冷系统普遍存在 3~5 秒温控滞后,极易造成芯片结温失控,威胁核心业务连续运行。海悟对算力基础设施可靠性体系进行重构,将运维模式从被动故障兜底升级为主动预判控制。 方案采用分层蓄冷缓冲设计,二次侧微缓冲承接 0-30 秒短时算力冲击,一次侧大蓄冷单元应对 30-120 秒长时间负载波动,显着提升系统抗冲击能力。依托智能 PDU 从电气侧秒级捕捉负载突变信号,驱动制冷系统提前响应,实现冷量先于热量生成的超前调控。同时在 CDU 机柜至冷源的全链路配置高速调节阀与变频泵,搭载智能预测算法,让冷量供给随算力负载实时动态匹配,为 AI 算力运行筑牢可靠防线。 高能效与可持续:全局优化能效,践行绿色低碳发展理念 算力密度持续攀升的背景下,数据中心能效升级不再局限于 PUE 指标优化,而是追求系统综合能效提升与项目长期可持续运营。海悟电冷算全链路协同架构,从供电、制冷、全生命周期运营多维度挖掘节能潜力。 供电链路优化线路布局,降低电能转换损耗,提升整体供电效率;制冷系统支持多冷源灵活组合,适配国内不同地域气候特征,充分利用自然冷源,拉高全年运行能效。同时方案延长设备使用寿命,简化运维工作,优化项目整体 TCO,在保障算力供给的同时降低碳排,践行绿色低碳发展理念。 算力基础设施是数字经济的基石。海悟坚持全生命周期・全链路制冷・全场景覆盖・全行业协同的建设理念,持续迭代算力基础设施解决方案。以系统协同为基础,以可靠性重构为核心,以高能效可持续为目标,持续推动面向未来的 AI 数据中心基础设施升级。让每一份算力都得到可靠承载、高效释放,持续为新型数字基建建设、绿色算力产业发展贡献力量。 相关新闻更多