海悟推出手插解耦型液冷机柜,单柜支持50~150kW高密度算力散热

Hiwave launches plug-in decoupled liquid cooling cabinet supporting 50–150kW per rack for AI data centers
海悟科技新闻T12026-10-09 · CN · 海悟科技 Hiwave
新品技术发布数据中心/IT散热

情报详报

What happened Hiwave announced on 2026-10-09 the launch of its plug-in decoupled liquid cooling cabinet, a direct-to-chip cold plate cooling product aimed at high-density data center thermal management. According to the company, the cabinet uses a direct-contact cold plate that targets server CPU and GPU heat sources directly, replacing traditional air cooling with a circulating liquid cooling loop. Its "full-stack liquid-electric decoupling" architecture is positioned for both greenfield data center construction and retrofit of existing air-cooled machine rooms, which the company says lowers the deployment barrier for high-density compute facilities. The product is marketed to AI computing centers, telecom operators and cloud computing data centers. Hiwave states the cabinet is compatible with Intel, AMD and ARM server platforms and can directly replace existing air-cooled cabinets for seamless upgrades. The announcement also frames the product against China's "East Data West Computing" national strategy and dual-carbon goals, and says it can support cross-regional compute scheduling and AI large-model training, HPC and cloud workloads. ### Key figures - Per-cabinet compute deployment density: 50–150 kW - Chip temperature differential controlled at ≤5°C - Heat transfer thermal resistance reduced by 40% versus traditional air cooling - Self-sealing connectors certified for 100,000 mating cycles - Piping material: 316L stainless steel, with corrosion rate below 0.01 mm/year - 5-year TCO reduction of 20%–30% versus traditional air cooling in medium-to-high density scenarios - Dual-pump hot standby and liquid-level interlock protection - Real-time monitoring of three parameters: flow, temperature and pressure - Compatibility: Intel, AMD and ARM server platforms - No pricing, production capacity, shipment volume or customer names disclosed. ### Why it matters to ebm-papst This is a direct signal that the high-density data center cooling market in China is shifting from air cooling toward liquid cooling, at least for GPU-heavy AI clusters. For ebm-papst, whose data center business is heavily tied to precision air movement and fan-based thermal solutions, the growth of direct-to-chip liquid cooling in the 50–150 kW per rack range represents a structural threat to the traditional fan wall and CRAC/CRAH air-cooling content per rack. If liquid cooling becomes the default for new AI capacity, the addressable fan content per megawatt could decline in that segment. At the same time, liquid cooling does not eliminate air movement: CDUs, secondary loops, leak-detection enclosures and residual rack-level airflow still require fans and blowers, and retrofit projects often need hybrid air-liquid architectures. Hiwave's emphasis on retrofit compatibility with existing air-cooled rooms and on replacing air-cooled cabinets directly suggests a transition period in which hybrid cooling persists, which could be a customer opportunity for ebm-papst in retrofit airflow, redundancy and monitoring components. Assessment (inference): Hiwave is a Chinese thermal management vendor rather than a global incumbent, so the near-term competitive impact on ebm-papst's European and North American data center business is likely limited; the more relevant risk is that Chinese liquid cooling designs and standards gain traction in domestic and Belt-and-Road data center projects, potentially displacing fan-centric architectures in those markets. Assessment (inference): ebm-papst should treat this as a market signal to accelerate its own liquid-cooling-adjacent portfolio, such as fan solutions for CDUs and hybrid cooling, rather than as an immediate head-to-head product threat. Assessment (inference): the absence of disclosed pricing, capacity or named customers means the commercial scale of this launch cannot yet be verified, and the 20%–30% TCO and 40% thermal resistance figures are vendor claims that have not been independently validated.

原文全文

原文 英文翻译
海悟手插解耦型液冷机柜|赋能高密度机房数据中心温控散热算力,夯实数字经济基础设施 发布时间:2026-10-09 随着 AI 大模型、算力集群快速落地,算力功率密度持续攀升,传统风冷散热方案已经难以满足 GPU、高性能服务器的稳定运行需求,液冷成为算力基础设施升级的核心方向。海悟推出手插解耦型液冷机柜,依托直接接触冷板散热技术与液电分离解耦架构,兼顾新建项目部署与存量机房风冷改造,以高安全、高效率、易运维的特性,为 AI 计算中心、运营商、云计算算力数据中心打造高性能散热底座,助力践行双碳目标,培育新质生产力。 海悟手插解耦型液冷机柜采用直接接触式冷板,直击服务器 CPU、GPU 核心热源,依靠循环液冷替代传统风冷。创新全栈液电分离解耦设计,打破部署场景限制,既可用于新建数据中心规划建设,也能完成存量机房升级改造,在提升散热性能的同时简化运维流程,大幅降低高密度算力机房的落地门槛。 多重安全防护体系,保障算力连续稳定运行。机柜配置经过 10 万次插拔认证的自密封接头,筑牢零泄漏基础;搭载双泵热备与液位联动保护,构建双重安全冗余,异常工况快速响应。管路选用 316L 不锈钢材质,腐蚀率低于 0.01mm / 年,长效抵抗介质腐蚀,支撑数据中心 7×24 小时不间断稳定作业。 精准控温,释放超高算力承载能力。冷板与热源直接接触,芯片温差控制在≤5℃,相比传统风冷,传热热阻降低 40%,换热性能大幅提升。单柜可实现 50~150kW 高密度算力部署,有效解决高密度 GPU 集群的局部热点难题,充分释放高性能服务器算力潜能。 轻量化改造 + 智能监控,大幅简化运维管理。产品完美兼容现有服务器产线,存量机房改造无需承重加固,省去大量土建改造投入。采用螺栓式盲插接口,支持免工具模块化快速更换,降低现场运维难度。系统可对流量、温度、压力三维参数实时采集监测,异常提前预警,实现机房精细化、智能化运维。 方案兼容 Intel、AMD、ARM 全平台服务器,能够直接替换原有风冷机柜,实现机房无缝升级。强大的场景适配性推动液冷技术在高密度算力场景从 “备选方案” 走向 “刚需方案”,拉动冷却液、管路、CDU 等上下游产业链协同发展,为液冷行业标准化落地积累宝贵实践经验。 从低碳与经济价值来看,海悟手插解耦型液冷机柜具备突出的全生命周期优势。在中高密度算力场景,5 年 TCO 相比传统风冷降低 20%-30%,前期建设、后期运维双向降本,长期持续释放碳减排效益,有效降低数据中心 PUE,打造低碳绿色算力中心。 紧扣 “东数西算” 国家战略,该产品可适配南北方不同地域机房环境,支撑跨区域算力调度,为 AI 大模型训练、高性能计算、云计算等前沿业务提供可靠底层支撑,持续赋能数字经济高质量发展。 算力时代,散热先行。海悟手插解耦型液冷机柜,以安全可靠的液冷技术、低成本存量改造能力、优异节能降碳表现,破解高密度算力散热痛点,助力数据中心迈向绿色低碳新阶段,为数字基础设施建设注入强劲动力。 相关新闻更多