China's liquid cooling shift: 24% of operators now run 30kW+ racks as PUE 1.3 rule bites

News · Dunham-Bush (zh)T22026-09-01 · CN · Carrier · Daikin · Trane Technologies · Johnson Controls · Dunham-Bush · NVIDIA
DatacenterPolicy / standardsHVAC

Intelligence brief

What happened A Chinese-language industry roundup published on 1 September 2026 (aggregated from Dunham-Bush) examines how accelerating liquid-cooling penetration in AI data centres is shifting value along the cooling chain. The core argument: as AI compute moves to higher power, heat management is no longer a matter of adding more fans inside servers. Rising per-GPU power and growing GPU counts scale the thermal problem from chip level to rack level, forcing high-density AI racks to be redesigned around liquid cooling. In existing data centres, air cooling remains dominant. For newly built high-power AI racks, cold-plate liquid cooling has become the main technical direction: liquid absorbs heat close to the chip, and a CDU (cooling distribution unit) isolates the server cooling loop from the facility water loop. The article cites NVIDIA's Rubin NVL72 as already in operation, and notes that the share of operators running racks above 30kW has risen from 19% to 24%, with the increment mainly from racks above 50kW. The piece frames liquid cooling as moving from an energy-efficiency constraint to a construction requirement. China's Ministry of Industry and Information Technology requires new large data centres to bring PUE below 1.3 and encourages facility-level technologies including liquid cooling. Shanghai's "Suanli Pujiang" initiative targets liquid-cooled racks exceeding 50% of intelligent-computing centre racks and supports deployment of racks above 100kW. Standards for cold-plate, immersion and spray cooling, coolants, efficiency testing and overall liquid-cooling system requirements have been implemented since 2021; a cold-plate liquid-cooling whole-rack standard landed in 2025, and a national standard for cold-plate liquid-cooling systems is due in 2026. The article splits the system into a primary (facility) side — chillers, outdoor free cooling and pumps, configured by heat-dissipation power — and a secondary side close to the server and chip, where value concentrates in cold plates, CDUs, manifolds and quick connectors. The CDU connects the two loops, performing isolated heat exchange so facility water never contaminates the server loop. On the primary side, mechanical cooling via chillers is expected to dominate in most high-standard Chinese data centres given hot summers and rising per-rack density (GB300). Compressors are the core chiller component: screw compressors account for 30% of chiller cost and magnetic-bearing centrifugal compressors 40%. Chiller component suppliers named include Carrier, York, Trane, Mayekawa, McQuay and Dunham-Bush among foreign brands, plus Midea, Gree, Haier, Hisense and Cigu Technology domestically; in magnetic-bearing compressors, Danfoss holds roughly 70% global share, alongside Emerson, Bitzer and Chinese players Hanbell, Cigu Technology and Chongqing General. ### Key figures - Share of operators with racks above 30kW: up from 19% to 24%, increment mainly from racks above 50kW. - China MIIT requirement: new large data centres to achieve PUE below 1.3. - Shanghai "Suanli Pujiang" target: liquid-cooled racks to exceed 50% of intelligent-computing centre racks; support for racks above 100kW. - Standards timeline: cold-plate, immersion, spray, coolant, efficiency-test and overall system standards implemented from 2021; cold-plate liquid-cooling whole-rack standard in 2025; national cold-plate liquid-cooling system standard in 2026. - Screw compressors: 30% of chiller cost. Magnetic-bearing centrifugal compressors: 40% of chiller cost. - Danfoss share of magnetic-bearing compressor market: approximately 70% globally. - NVIDIA Rubin NVL72: stated as already in operation (no shipment or volume figures disclosed). - No specific figures disclosed for market size, unit volumes or revenue. ### Why it matters to ebm-papst The article's central claim is that rack-level heat is migrating from air to liquid, with cold plates, CDUs, manifolds and quick connectors capturing value on the secondary side and chillers/compressors on the primary side. Air cooling is described as remaining dominant in the existing installed base, but not in new high-power AI racks. Assessment (inference): This is a structural demand signal rather than an immediate threat. ebm-papst's core data-centre business is air moving — fans and blowers for servers, racks and precision cooling — and the fastest-growing new-build segment is precisely where air cooling's share is being displaced. The offsetting opportunity is on the primary side: chillers, CDUs and facility cooling equipment still require fans, blowers and motors, and higher-density mechanical cooling raises the specification bar for those components. ebm-papst is not named among the chiller or compressor suppliers in this article, so its position in that value chain is not evidenced here. Assessment (inference): The standards timeline (2025 whole-rack, 2026 national system standard) suggests procurement will consolidate around qualified suppliers within roughly the next 12–18 months, which favours vendors with documented reliability and test data. ebm-papst should treat China's liquid-cooling buildout as a portfolio question: defend air-side content in the installed base and hybrid/retrofit designs, while assessing whether fan and blower content inside CDUs, chillers and liquid-cooling ancillary equipment is addressable with existing product lines. The named chiller and compressor incumbents (Carrier, Trane, Dunham-Bush, Danfoss and others) are potential channel partners or competitors depending on component scope, and none of them is identified here as an ebm-papst customer or partner.

Full text

Original English translation
Liquid cooling industry chain: penetration accelerating — which segments will be pushed up by high-power racks? As AI compute continues to move toward higher power, the heat dissipation problem is no longer just about installing a few more fans inside servers. With GPU single-chip power rising rapidly and GPU counts increasing, heat is amplified from chip level to rack level, and high-density AI racks must rearrange their cooling systems. This is also where liquid cooling has changed the most. In existing data centres, air cooling is still mainstream. For newly added high-power AI racks, cold-plate liquid cooling has become the main technical direction: liquid absorbs heat near the chip, and then a CDU isolates the server cooling loop from the data centre water loop. As high-power racks begin to scale, the demand side now has harder evidence. NVIDIA Rubin NVL72 has already entered operational status, and the share of operators with racks above 30kW has risen from 19% to 24%, with the increment mainly coming from racks above 50kW. Liquid cooling moves from an energy-efficiency constraint to a construction requirement Liquid cooling is not being driven by AI server enthusiasm alone. Domestic data centre construction is simultaneously constrained by energy-efficiency indicators: the Ministry of Industry and Information Technology requires new large data centres to reduce PUE below 1.3, and encourages research and development of facility-level technologies such as liquid cooling. PUE can be understood as the ratio between a data centre's total power consumption and its IT equipment power consumption; the lower the value, the less is consumed by supporting segments such as power distribution and cooling. When energy-efficiency pressure lands on the construction side, it pushes machine rooms from demonstration projects toward standardised procurement. Shanghai's "Suanli Pujiang" initiative proposes that liquid-cooled racks account for more than 50% of intelligent-computing centre racks, and supports deployment of high-density racks above 100kW. Since 2021, standards for cold-plate, immersion and spray types, coolants, energy-efficiency testing and overall liquid-cooling system requirements have been implemented one after another; in 2025 the cold-plate liquid-cooling whole-rack standard landed, and in 2026 the national standard for cold-plate liquid-cooling systems was released. What policy and standards jointly change is the criteria for project implementation. In the past, liquid cooling was more like an option in a few high-performance computing scenarios; now design, testing, tendering and acceptance can proceed along more unified standards, and the conditions for liquid-cooled rack scale-up have shifted from "can it be done" to "can it be delivered stably at volume". The primary side determines the cold source, the secondary side sits close to the chip After high-power racks carry heat out, the liquid-cooling system passes through two loops. The primary side is the facility-level shared cold source, mainly including chillers, outdoor cold sources and pumps; it is more standardised and configured according to heat dissipation power. The secondary side is close to the server and chip, with value concentrated in cold plates, CDUs, manifolds and quick connectors, and with higher customisation and reliability requirements. The two loops are connected by the CDU. Chilled water produced by the chiller does not directly cool computing chips such as GB200 and GB300; instead, inside the CDU it performs isolated heat exchange with the secondary-side circulating coolant, both carrying heat away and preventing the server-side loop from being contaminated by the facility water loop. The real industry-chain change is that liquid-cooling value does not rest only in the rack as a whole, but is split across multiple key components: cold source, heat exchange, circulation, distribution and connection. Secondary-side requirements are closer to hardware reliability. Cold plate assemblies mostly use thermally conductive materials such as copper or aluminium, with internal microchannel structures, directly contacting heat-generating devices for heat exchange. The CDU handles filtration, pressurisation, temperature control and distribution. Piping and connectors handle coolant transport and circulation, and must also provide leak prevention and quick disassembly/reassembly. These segments are not simple accessories; failure at any node will affect the stable operation of the entire rack. Mechanical cooling pushes compressors to the fore The key equipment on the primary side is the chiller. When local ambient temperatures are generally low and cooling demand is not great, natural cooling alone can be used. But China has pronounced seasonal variation, with high temperatures nationwide in summer, and combined with the increase in per-rack power density of GB300, most high-standard data centres in future will use mechanical cooling, that is, chillers. The core component of a chiller is the compressor, which drives the refrigeration cycle and transfers heat absorbed by the liquid-cooling system to the external environment. According to cooling capacity and technical principle, compressors include scroll compressor units, screw compressors and centrifugal compressors; among these, screw compressors account for 30% of chiller cost, and magnetic-bearing centrifugal compressors account for 40% of unit cost. As data centres shift more from natural cooling to mechanical cooling, compressors will directly affect chiller cost and supply elasticity. The supply landscape also shows that this segment still has room for substitution. Participants in chiller core components include foreign brands such as Carrier, York, Trane, Mayekawa, McQuay and Dunham-Bush, as well as domestic enterprises such as Midea, Gree, Haier, Hisense and Cigu Technology. Among magnetic-bearing compressor suppliers, Danfoss holds about 70% global share, with international companies such as Emerson and Bitzer as well as domestic manufacturers including Hanbell, Cigu Technology and Chongqing General participating together.