Stulz 发布第四代 TelAir 4 与 WallAir 4 数据中心冷却系列

Stulz launches TelAir 4 and WallAir 4 cooling units with R454C, 6-17kW, up to 80% cost savings
聚合·StulzT22026-09-01 · INTL · Stulz 世图兹
新品技术发布数据中心/IT散热商用暖通
▾ 2 条同事件报道

情报详报

What happened On 1 September 2026, German cooling specialist Stulz announced the fourth generation of its TelAir and WallAir cooling series, designated TelAir 4 and WallAir 4. According to the company, the new units are aimed at the growing demands of 5G, edge and critical infrastructure applications. The TelAir 4 series is designed for indoor installation, while the WallAir 4 is a monobloc solution that can be mounted externally on a container wall to save space. Both series combine a lower-GWP R454C refrigerant with integrated free cooling and a certified EN378 safety architecture. Stulz states that both lines are available in two standard enclosure sizes and four cooling capacity classes. Customers can choose between classic on/off systems fitted with a thermostatic expansion valve, or continuously modulating EC inverter compressors paired with an electronic expansion valve. In both variants the evaporator fan is positioned at the bottom to quickly dilute and extract refrigerant gases in the event of a leak. A two-stage sensor system activates maximum fan speed and shuts down other power consumers at 10% of the lower flammability limit (LFL), while at 20% LFL the unit is fully disconnected from the power supply. An enclosed IP54 control cabinet further eliminates potential ignition sources. In terms of airflow, the TelAir 4 series supports both downflow and displacement concepts, with optional adjustable outlet grilles for targeted horizontal or vertical air distribution without mixing cold and warm air. WallAir 4 uses the displacement principle for direct cold air stratification within the room. Stulz also highlights that TelAir 4's in-wall installation provides protection against weather and vandalism and reduces noise emissions to levels suitable for sensitive residential and mixed-use areas. The E² Basic controller enables operation through an integrated ethernet interface, Modbus and a wide range of inputs and outputs for integration with building management and DCIM systems, with password-protected access levels and dedicated inputs for monitoring fire, smoke and intrusion alarms. ### Key figures - Product generations: TelAir 4 and WallAir 4 (fourth generation) - Refrigerant: R454C (lower GWP) - Cooling capacity classes: four, ranging from 6-17kW - Enclosure sizes: two standard sizes - Claimed operating cost reduction: up to 80% in combined free cooling and mixed-mode operation - Operating temperature range: -20°C to 54°C for both TelAir 4 and WallAir 4 - Optional winter kit: extends operation down to -40°C - Safety thresholds: maximum fan speed and shutdown of other power consumers at 10% LFL; full power disconnection at 20% LFL - Control cabinet protection rating: IP54 - Announcement date: 1 September 2026 - Location: Germany (company announcement) ### Why it matters to ebm-papst Stulz is a direct competitor in precision cooling for data centres, edge and critical infrastructure, and the TelAir 4 / WallAir 4 launch refreshes its portfolio in exactly the 6-17kW edge and container segment where ebm-papst fans and motors are widely designed in. The explicit use of EC fans across a -20°C to 54°C range, with an optional winter kit down to -40°C, signals continued demand for high-efficiency, wide-temperature EC fan platforms in this class. Assessment (inference): The shift to R454C, a mildly flammable A2L refrigerant, combined with the leak-mitigation architecture (bottom-mounted evaporator fan, two-stage LFL sensor logic, IP54 cabinet) raises the bar for component suppliers. Fan and motor solutions used in these units may increasingly be expected to support A2L-compatible safety concepts, spark-free or low-ignition-risk designs, and documented behaviour under leak scenarios. This could favour suppliers able to co-engineer with OEMs on safety certification rather than supplying commodity air movers. Assessment (inference): The claimed up-to-80% operating cost reduction from free cooling and mixed-mode operation, together with EC inverter compressor options, reinforces the market's focus on part-load efficiency and total cost of ownership. For ebm-papst this is both a competitive signal and a customer opportunity: Stulz and similar OEMs will need EC fans with precise speed control, wide input/output integration and compatibility with BMS/DCIM monitoring. The emphasis on Modbus, ethernet and DCIM integration also suggests growing demand for intelligent, communicable fan units rather than standalone motors. Assessment (inference): The container-mountable WallAir 4 monobloc and the in-wall TelAir 4 point to continued growth in space-constrained edge and 5G deployments, a segment where compact, low-noise, weather-resistant fan solutions command a premium. ebm-papst should treat this launch as a prompt to verify its roadmap against A2L refrigerant requirements, -40°C extended operation and noise-sensitive residential siting, and to engage Stulz and comparable OEMs early in their next design cycles.

原文全文

Stulz launches data centre cooler upgrades 1st September 2026GERMANY: Stulz has announced a fourth generation of its TelAir and WallAir cooling series to meet the growing demands of 5G, edge and critical infrastructure applications. TelAir 4 and WallAir 4 combine the advantages of a lower GWP R454C refrigerant with integrated free cooling and a certified EN378 safety architecture. The TelAir 4 series is designed for indoor installation, while the WallAir 4 can be mounted externally on a container wall as a space saving monobloc solution. Both are available in two standard enclosure sizes and four cooling capacity classes, ranging from 6-17kW. In combined free cooling and mixed-mode operation, Stulz claims the TelAir and WallAir units can reduce operating costs by up to 80%. With EC fans, the units operate across a temperature range from -20°C to 54°C for TelAir 4 and -20°C to 54°C for WallAir 4. For extreme climates, an optional winter kit extends operation down to -40°C. Customers can choose between classic on/off systems that are equipped with a thermostatic expansion valve, or continuously modulating EC inverter compressors paired with an electronic expansion valve. In both variants the evaporator fan is positioned at the bottom to quickly dilute and extract refrigerant gases in the event of a leak. A two-stage sensor system activates maximum fan speed and shuts down other power consumers at 10% of the lower flammability limit, while at 20% LFL the unit is fully disconnected from the power supply. An enclosed IP54 control cabinet further eliminates potential ignition sources. In terms of airflow, the TelAir 4 series supports both downflow and displacement concepts, with optional adjustable outlet grilles for targeted horizontal or vertical air distribution without mixing cold and warm air. WallAir 4 utilises the proven displacement principle for direct cold air stratification within the room, and TelAir 4’s in-wall installation provides protection against weather and vandalism, reducing noise emissions to levels suitable for use in sensitive residential and mixed-use areas. Stulz says it has prioritised ease of use and its E² Basic controller enables operation through integrated ethernet interface, Modbus and a wide range of inputs and outputs for seamless integration with building management and (DCIM) systems. Password protected access levels provide enhanced security, alongside dedicated inputs for monitoring fire, smoke and intrusion alarms.