# Sungrow launches PowerMatrix matrix inverter at SNEC 2026, cutting 1GW/2GWh project CAPEX by RMB 326m

- Source: News · Sungrow (T2)
- Published: 2026-06-04
- Score: 55.6
- Tags: Product launch, ESS
- Companies: Sungrow (300274.SZ)
- Original: http://www.eeo.com.cn/2026/0604/902933.shtml

## Intelligence brief

### What happened On 3 June 2026, Sungrow (300274.SZ) unveiled its PowerMatrix™ matrix inverter at the 19th International Solar Photovoltaic and Smart Energy Conference (SNEC 2026), held at the National Exhibition and Convention Center in Shanghai. Alongside the inverter, the company introduced a matrix inverter system built around it. According to Sungrow, the PowerMatrix™ matrix inverter is a new product category that integrates PV inversion, energy storage power conversion, energy routing and grid-forming control into a single unit, positioned as a core energy node for new-type power systems. It is intended to replace the conventional grid-connection logic centred on separate PV inverters and storage PCS, shifting overall system control to the matrix inverter itself. Sungrow argues that years of record-chasing on single-point metrics such as module and inverter efficiency have not delivered holistic breakthroughs for PV-plus-storage sites. The company frames the matrix inverter as a system-level reconstruction that helps PV become a main power source. Zhang Xianli, Sungrow Vice President and President of the Ground-mounted PV Business Unit, described the product as an "octopus" because a new-type power system has a more complex generation side and growing load-side demand, requiring grid-connection equipment with multiple interfaces and scalability. The matrix inverter system can connect PV, storage, multiple load types and multiple grid-connection points, with more than 40 operating modes, redundant multi-path supply, dynamic switching to the optimal energy path, automatic isolation of local faults and uninterrupted supply. Each sub-array can form the grid independently, with 10 ms voltage stabilisation, 5 ms effective inertia response and GW-level black start in 8 minutes. ### Key figures - Event date: 3 June 2026; venue: National Exhibition and Convention Center, Shanghai (SNEC 2026, 19th edition). - More than 40 operating modes in the matrix inverter system. - Grid-forming performance: 10 ms stable voltage, 5 ms effective inertia response, 8 minutes for GW-level black start. - PV site capability: up to 260% DC/AC ratio, 200% high charging power, over 3,000 annual equivalent generation hours. - PV side: up to 28 MPPT channels per MW, 0.8% PV generation improvement. - Storage side: multi-level SOC balancing from cell to station, 8% lifetime discharge energy improvement. - Power conversion: two fewer conversion stages, 3%–5% efficiency gain. - Reference project in Northwest China: 1 GW PV, 2 GWh storage (4-hour duration), 2,500 average annual utilisation hours; CAPEX reduced by RMB 326 million and IRR improved by more than 1.5% versus a conventional AC-coupled solution. - PV plant investment return improved by at least 1.5% with the matrix inverter solution. ### Why it matters to ebm-papst Sungrow is a major global player in PV inverters and energy storage systems, and its push toward integrated, multi-port, grid-forming power conversion reshapes the architecture of utility-scale PV-plus-storage sites. For ebm-papst, this is primarily a market signal about where thermal management demand is heading: higher-power-density, multi-port converters with DC bus architectures and fewer conversion stages will change airflow, cooling and fan-redundancy requirements inside inverter and PCS enclosures. Assessment (inference): The shift from separate PV inverters and storage PCS to a single integrated matrix unit could concentrate fan content per enclosure while reducing the total number of discrete cabinets on a site, which may lower unit volumes but raise per-unit cooling value and specification requirements. Assessment (inference): Sungrow's emphasis on 260% DC/AC ratio, 200% charging power and 3,000+ equivalent hours implies sustained high-load operation, increasing the importance of high-efficiency, long-life, speed-controlled fans and of thermal solutions qualified for harsh Northwest China conditions. Assessment (inference): The claimed CAPEX reduction of RMB 326 million per 1 GW/2 GWh project and reduced transformer demand could accelerate adoption of DC-coupled, integrated architectures, pressuring ebm-papst's existing AC-coupled inverter and PCS cooling business while opening opportunities in DC bus, energy-router and grid-forming converter cooling. Assessment (inference): As a Chinese OEM scaling globally, Sungrow represents both a competitive benchmark for local Chinese fan suppliers and a potential customer opportunity for ebm-papst if it can position high-reliability, high-efficiency fan and thermal subsystems for multi-port matrix converters. Assessment (inference): The absence of disclosed fan or thermal specifications means ebm-papst should seek direct technical engagement with Sungrow's ground-mounted PV and storage teams to qualify cooling components early in the next product generation.

## Full text (English translation)

On 3 June, the 19th (2026) International Solar Photovoltaic and Smart Energy Conference (SNEC 2026) grandly opened at the National Exhibition and Convention Center in Shanghai. Sungrow officially released the PowerMatrix™ matrix inverter at the venue, and simultaneously launched a matrix inverter system with it at its core.

The PowerMatrix™ matrix inverter is a brand-new category integrating PV inversion, energy storage power conversion, energy routing and grid-forming control, and is a core energy node for new-type power systems. This matrix inverter "reshapes" the traditional grid-connection logic centred on PV inverters and storage PCS, shifting to overall system control via the matrix inverter.

Over the past few years, the industry has continuously set new records on single-point metrics such as the efficiency of PV modules and inverters, but this has not brought holistic breakthroughs for PV-plus-storage sites. Sungrow hopes to use the matrix inverter to achieve system reconstruction of PV-plus-storage sites and help PV become a main power source.

Why matrix

Matrix is a mathematical term, representing a set of complex or real numbers arranged in a rectangular array, implying multi-level relationships. In engineering, matrix implies a system architecture that can be used for combination, expansion and reconstruction.

Sungrow believes that the matrix in the power system should represent orderly coordination among source, grid, load and storage. This means the access of multiple elements, multi-path links and coordination of multiple systems.

The matrix inverter is the meeting point of all elements, paths and systems. Zhang Xianli, Sungrow Vice President and President of the Ground-mounted PV Business Unit, calls it an "octopus".

Zhang Xianli said that unlike traditional power systems, the generation side of new-type power systems has a more complex structure and load-side demand keeps increasing, which requires grid-connection equipment to have multi-interface and expandable capabilities, so that one site can stably and reliably meet different needs.

For PV-plus-storage sites to move toward becoming a main power source, they must have four capabilities: use on demand, grid stability, safety and reliability, and economic efficiency, and these are exactly what the matrix inverter aims to provide.

Relying on a multi-port architecture and constant-voltage bus, the PowerMatrix™ matrix inverter upgrades traditional single-path transmission to a multi-node collaborative network, with multiple functions including multi-port integration, native PV-storage fusion, energy path reconstruction, hierarchical collaborative control and source-side grid forming.

Most existing PV-plus-storage sites are installed separately, connected to the grid independently and responding to grid dispatch, without interfering with each other during operation. This brings flexibility to site selection for PV and storage stations, but also leads to problems such as long links between PV and storage stations, high conversion losses, fragmented configuration, dispersed control and difficult coordination.

The matrix inverter system can connect PV, storage, multiple types of loads and multiple grid-connection points, with PV and storage naturally coordinated in structure; multi-path energy redundant supply, 40+ operating modes, the system can dynamically switch to the optimal energy path according to operating status, automatically isolate local abnormalities and provide uninterrupted power supply.

At the same time, the matrix inverter has the ability to sense and control current transmission paths, with control precise down to specific sub-arrays, adjusting current supply chain paths in real time to avoid single-point fluctuations triggering overall system risk. The generation unit of the matrix inverter system is also a grid-forming unit; each sub-array has independent grid-forming capability, enabling 10 ms stable voltage, 5 ms effective inertia response and completion of GW-level black start in 8 minutes.

Power stations move toward the refined era

In the new period of rapid construction of new-type power systems, new energy installed capacity is no longer "the bigger the better", but the higher the quality the better. The "Implementation Rules for Power Grid-connection Operation Management" and the "Implementation Rules for Power Auxiliary Service Management" impose increasingly refined requirements on power stations.

A PV site equipped with the PowerMatrix™ matrix inverter can achieve a DC/AC ratio of up to 260%, a high charging power of 200% and more than 3,000 annual equivalent generation hours.

By controlling site operation through the system, the PowerMatrix™ matrix inverter can perfectly adjust to grid demand, thereby achieving site dispatchability.

When PV generation is high, the matrix inverter automatically regulates surplus power into storage; when PV generation is low or absent, the matrix inverter regulates storage discharge, all completed within one system without dispatch through the grid.

On the PV side, up to 28 MPPT independent tracking controls per MW can be achieved, precisely tracking the maximum power point, reducing mismatch losses and improving PV generation by 0.8%. On the storage side, multi-level SOC balancing from cell to station improves lifetime storage discharge energy by 8%; in power conversion and transmission, two conversion stages are eliminated and energy conversion efficiency is improved by 3%–5%. At the same time, the dynamic energy path switching function can also reduce line losses and ineffective energy flow; in energy consumption, it greatly improves new energy access elasticity and system absorption capacity, promoting a high proportion or even full absorption of green power and further reducing curtailment losses of PV and wind.

According to calculations, using the matrix inverter solution, the investment return of a PV site improves by at least 1.5%; the larger the storage capacity and the longer the duration, the more is saved.

Costs are also falling. Compared with traditional AC-coupled solutions, the "one-stop service" of the matrix inverter can effectively save costs on PCS, cables, synchronous condensers and more. Amid the current shortage of transformers, the matrix inverter can also reduce transformer demand through DC output, helping customers deploy sites faster.

Taking a typical PV-plus-storage project in Northwest China as an example, under a design target of 1 GW PV installed capacity, 2 GWh storage installed capacity (4-hour storage) and an average annual utilisation of 2,500 hours, compared with a traditional AC-coupled solution, the matrix inverter system can reduce costs across multiple links including booster stations, transmission lines, storage equipment, PV equipment and grid-related testing, achieving a CAPEX reduction of RMB 326 million and an IRR improvement of more than 1.5%.

At the critical stage when PV is accelerating from a supplementary energy source to a main power source, the launch of the PowerMatrix™ matrix inverter undoubtedly has epoch-making significance. It not only brings a new solution to the long-standing "impossible triangle" of cost, efficiency and stability, but also breaks through the capability boundaries of new energy systems, driving new energy to evolve from an "intermittent power source" to a main power source that is "dispatchable, supportive and grid-forming".

## Full text (original)

6月3日，第十九届 (2026) 国际太阳能光伏与智慧能源 (上海）大会（SNEC 2026）在上海国家会展中心盛大启幕。阳光电源发布在会场正式发布PowerMatrix™矩阵逆变器，并同步推出以其为核心的矩阵逆变系统。
PowerMatrix™矩阵逆变器是集成光伏逆变、储能变流、能量路由与构网控制于一体的全新品类，是面向新型电力系统的核心能量节点。该款矩阵逆变器“重塑”了传统以光伏逆变器、储能PCS为核心的并网逻辑，转向以矩阵逆变器实现系统整体控制。
过去几年，行业在光伏组件、逆变器的效率等单点指标上不断刷新纪录，但并未带来光储场站整体性的突破。阳光电源希望以矩阵逆变器，实现光储场站系统重构，助力光伏成为主力电源。
何以矩阵
矩阵是数学名词，代表着一个按照长方阵列排列的复数或实数集合，意味着多层级的关系。在工程学中，矩阵意味着可以用于组合或拓展、重构的系统架构。
阳光电源认为，电力系统中的矩阵，应代表着源网荷储之间的有序协同。这意味着多元素的接入、多路径的链接以及多系统的协调。
矩阵逆变器，即是所有元素、路径和系统的集合点。阳光电源副总裁、地面光伏事业部总裁张显立称之为“八爪鱼”。
张显立表示，与传统电力系统不同，新型电力系统电源侧结构更加复杂，负荷端需求不断增多，这就要求并网设备需要具备多接口、可拓展的能力，以实现一个场站稳定、可靠地满足不同需求。
光储场站要想走向主力电源，必须具备随需所用、稳定电网、安全可靠和经济高效四大能力，而这正是矩阵逆变器想要提供的。
PowerMatrix™矩阵逆变器依托多端口架构与恒压母线，将传统单一路径传输升级为多节点协同网络，具备多端口一体化、光储原生融合、能量路径重构、分层级协同控制以及源侧构网等多重功能。
现有的光储场站大多分离安装，独立接入电网并响应电网调度，在运行过程中并不干扰，这为光伏、储能场站选址带来了灵活性，也导致了光伏、储能场站之间链路长、变换损耗多、配置割裂、控制分散、协同难等问题。
矩阵逆变系统可接入光伏、储能、多类负载及多个并网点，光储在结构上天然协同；多路能源冗余供电，40+运行模式，系统可根据运行状态动态切换最优能量路径，局部异常时自动隔离，不间断供电。
同时，矩阵逆变器具备对电流传输路径的感知与控制能力，精确到具体子阵进行控制，实施调整电流供应链路径，避免单点波动引发系统整体风险。矩阵逆变系统的发电单元同时也是构网单元，每个子阵均具备独立构网能力，可实现10ms稳定电压、5ms有效惯量响应、8min完成GW级黑启动。
电站走向精细化时代
在新型电力系统迅猛建设的新时期，新能源装机不再是“越大越好”，而是质量越高越好。《电力并网运行管理实施细则》《电力辅助服务管理实施细则》等对电站提出了越来越精细化的要求。
搭配PowerMatrix™矩阵逆变器的光伏场站可实现最高260%的容配比、200%的高充电功率以及3000小时以上的年等效发电小时数。
通过系统控制场站运行，PowerMatrix™矩阵逆变器可以完美复合电网需求进行调节，进而实现场站的可调度性。
当光伏发电较多时，矩阵逆变器会自动调节多余电量进入储能，当光伏少发或者不发时，矩阵逆变器再调节储能进行放电，全程在一个系统中完成，无需通过电网进行调度。
在光伏侧，可实现每MW多达28路MPPT独立跟踪控制，精准追踪最大功率点，减少失配损失，光伏发电提升0.8%。在储能侧，从芯到站多级SOC均衡，实现全生命周期储能放电量提升8%；在电能转换与传输上，电能变换减少2级，能量转换效率提升3%~5%。同时，能量路径动态切换功能还可降低线损与无效能量流动；在能源消纳上，大幅提升新能源接入弹性与系统消纳能力，推动绿电高比例、甚至全量消纳，进一步降低弃光弃风损失。
根据测算，采用矩阵逆变器方案，光伏场站投资收益至少提升1.5%，储能容量越大、时长越长，省的越多。
成本也在降低。相比于传统交流耦合方案，矩阵逆变器“一站式服务”能够有效节约PCS、线缆、调相机等成本。在当前变压器供不应求的情况下，矩阵逆变器还可以通过直流输出，减少对变压器的需求，帮助客户更快部署场站。
以西北地区典型光储项目为例，在1GW光伏装机、2GWh储能装机（4小时储能）、年平均利用小时数2500小时的设计目标下，相较传统交流耦合方案，矩阵逆变系统可降低升压站、外送线路、储能设备、光伏设备、涉网测试等多环节成本，实现CAPEX降低3.26亿元，IRR提升1.5%以上。
在光伏加速从补充能源迈向主力电源的关键阶段，PowerMatrix™矩阵逆变器的推出无疑具有划时代的意义。它不仅为长期困扰行业的成本、效率、稳定性“不可能三角”带来了全新解法，更突破了新能源系统的能力边界，推动新能源从“间歇式电源”向“可调度、可支撑、可构网”的主力电源演进。