# Liquid cooling report: NVIDIA R200 at 2300W drives CDU pump market to $1.14-1.54bn by 2026

- Source: News · Dunham-Bush (zh) (T2)
- Published: 2026-02-05
- Score: 42.6
- Tags: Market data, Datacenter
- Companies: Carrier, Johnson Controls, Dunham-Bush, NVIDIA, Meta
- Original: https://caifuhao.eastmoney.com/news/20260205210522384975180

## Intelligence brief

### What happened A Chinese-language industry deep-dive report on data center thermal management, aggregated from Dunham-Bush (the data center cooling brand of Chinese refrigeration group Moon Environment / Ice Wheel Group), was published on 5 February 2026. The report argues that liquid cooling has shifted from an optional technology route to a mandatory line item in compute infrastructure spending, driven by rising accelerator power density. It focuses on two incremental value pools in the liquid cooling thermal chain: the CDU (coolant distribution unit) liquid pump on the secondary loop, and the primary-side refrigeration/chiller system. The report covers component value share, technical selection parameters, material compatibility constraints, market sizing, and the business progress of named suppliers including Feilong (Flying Dragon) Auto Parts and Moon Environment's Dunham-Bush and Ice Wheel Heat Exchange Technology units. The full text is behind a paywall; only the truncated version is available. ### Key figures - NVIDIA single-chip power: ~1000W in the B200 generation, moving toward 2300W for the R200 architecture mass-produced in 2026, potentially exceeding 4000W in the planned R300 for 2027. - Rack power density threshold of 50kW cited as the point at which traditional air cooling becomes unviable. - CDU accounts for 30%-40% of total liquid cooling system value; the liquid pump accounts for 35% of CDU internal value. - NVIDIA disclosed in 2025 roughly 14 million GPU orders across Blackwell and Rubin architectures over the five quarters to 2026. - 2026 NVIDIA rack liquid cooling system market estimated at USD 6.9bn (conservative) to USD 9.7bn (optimistic). - Google TPUv7 rack liquid cooling value: USD 70,000-80,000 per rack, equivalent to USD 1,094-1,250 per chip; 2026 shipments of 2.2-2.3 million chips, contributing USD 2.4-2.9bn. - Meta ASIC target: 1.0-1.5 million units shipped between end-2025 and 2026. - Combined 2026 global liquid cooling system market: USD 9.3bn-12.6bn; corresponding annual CDU liquid pump demand: USD 1.139bn-1.544bn. - Pump efficiency above 70% with brushless motors or magnetic bearings, up to 30% energy savings versus conventional industrial pumps; N+1 redundancy with failover within 15 seconds; MTBF of at least 50,000 hours. - Worked example: a 200kW heat load at a 10 degrees C delta-T requires about 5 cubic metres per hour of flow; 10%-20% head safety margin recommended. - Global data center chiller market revenue: about RMB 105.21bn in 2024, forecast to reach RMB 167.33bn by 2031, CAGR about 6.7%; 2024 output 128,700 units at an average price of USD 113,000. - Compressors account for more than 50% of chiller cost; magnetic levitation centrifugal compressors cited as saving over 40% energy versus screw compressors. - Feilong: liquid cooling pumps covering 16W to 22kW, supporting CDU heat rejection from 24kW to 2.5MW; HP22K pump batch delivery ceremony in December 2025; 2024 revenue RMB 4.723bn, net profit attributable to parent RMB 330m. - Dunham-Bush: first centrifugal compressor product in 1965, magnetic levitation compressor launched in 2014. ### Why it matters to ebm-papst This report frames the data center thermal chain as a value migration away from air-side components toward liquid-side pumps and primary refrigeration. For ebm-papst, whose data center exposure today is concentrated in fan and air-movement solutions, the 50kW rack threshold is the key signal: above it, air cooling is described as no longer viable, which compresses the addressable market for high-static-pressure fan arrays in new high-density builds while expanding the adjacent pump, CDU and chiller ecosystem. Assessment (inference): The report's explicit statement that specialist long-life data center liquid cooling pump suppliers remain "extremely scarce" outside a few centralized CDUs using Grundfos AC large pumps represents both a competitive warning and a plausible adjacency opportunity. ebm-papst already possesses core competencies in brushless DC motor drives, magnetic bearing know-how, long-life bearing systems and fluid-moving impeller design, all of which map directly onto the pump requirements listed here (over 70% efficiency, N+1 redundancy, 15-second failover, 50,000-hour MTBF). Assessment (inference): entering CDU pump supply would put ebm-papst into a component category with a stated 2026 serviceable market of USD 1.14-1.54bn and a 35% value share inside CDUs, but it would also place it in competition with established pump specialists and with Chinese motor/pump manufacturers such as Feilong that are already qualified on NVIDIA GB200 and Huawei Ascend platforms. Assessment (inference): the named chiller incumbents Johnson Controls and Carrier, alongside Chinese players including Haier, Gree and Moon Environment, are the likely direct customers or channel partners for any ebm-papst liquid-cooling component, since they own the primary-side refrigeration architecture. Assessment (inference): the report's emphasis on magnetic levitation centrifugal compressors as the growth architecture is a market signal that high-speed motor and drive technology, rather than fan blade design, will define the next wave of data center thermal value. Assessment (inference): the principal risk to this reading is timing, since the report itself flags that slower-than-expected liquid cooling iteration could shift the industrialization timeline, and that current valuations may not be matched by earnings delivery.

## Full text (English translation)

All content of the report: please read the original in the public account 'Market Analysis Report'.

'Data Center Thermal Management Deep Report: Liquid Cooling Upgrade + CDU Pumps + Refrigeration Systems, the Two Most Certain Companies'

NVIDIA's single-chip power consumption has already risen rapidly from the 1000W level of the B200 era toward the 2300W of the R200 architecture to be mass-produced in 2026, and may even break through the 4000W mark in the R300 planned for 2027. When rack power density crosses the 50kW watershed, the traditional air cooling model can no longer carry the instantaneous high thermal load at all, and liquid cooling systems are growing from an alternative option among selectable technology routes into a rigid expenditure in computing infrastructure.

This review focuses mainly on the two core incremental segments in the liquid cooling thermal management industry chain: the CDU liquid cooling pump, which serves as the 'heart' of the secondary-side circulation, and the refrigeration system responsible for generating and transferring the primary-side cooling source. It breaks down in detail every element from component value content and technical parameter selection to the business progress of leading manufacturers.

I. The core hub role of the liquid cooling pump in the circulation system

In the entire liquid cooling circulation link, the CDU (coolant distribution unit) plays the role of control hub, and the liquid cooling pump is the most critical power component inside this hub. Its working principle is to drive the coolant through a closed pipeline to achieve forced convection via precise fluid dynamics mechanisms, building an efficient heat exchange system. In actual deployment, the liquid cooling pump cluster is usually integrated into the CDU cabinet in the main equipment room, delivering the cooling medium to the server front end through high-density polyethylene piping. After the coolant passes through end devices such as CPU cold plates and memory heat dissipation modules, it carries away the thermal load generated by the computing core and returns to the main equipment room, ultimately forming a closed transfer loop of 'coolant - heat source - cooling tower'.

The pump's core task in this process is to regulate the flow rate and system pressure of the coolant. The pump can precisely deliver flow according to the real-time heat generation of the chip. When the equipment is in a high-load computing state and generates intense heat, the pump will rapidly increase the flow rate to carry away the high temperature; during low-load periods it will moderately reduce it to avoid unnecessary energy waste.

In terms of pressure regulation, the pump must ensure stable fluid flow within the system, avoiding pipeline failures caused by excessive pressure differences or local overheating risks caused by uneven flow distribution. At present, the CDU accounts for 30% to 40% of the value of the entire liquid cooling system, while the liquid cooling pump accounts for as much as 35% of the value inside the CDU.

II. Market size driven by NVIDIA and major-company orders

The volume ramp of computing chips directly determines the market ceiling for liquid cooling components. NVIDIA disclosed in 2025 that within the five quarters through 2026, its total GPU orders for the Blackwell and Rubin architectures amount to about 14 million units. Based on this order scale, the 2026 NVIDIA rack liquid cooling system market share is expected to reach USD 6.9 billion and USD 9.7 billion under conservative and optimistic scenarios respectively. At the same time, Google's TPUv7 rack liquid cooling system shows extremely high value attributes, with a single-rack value of between USD 70,000 and USD 80,000, corresponding to a per-chip thermal management cost of about USD 1,094 to USD 1,250. It is expected that Google's shipments of chips of the relevant grade will reach 2.2 million to 2.3 million units in 2026, thereby contributing about USD 2.4 billion to USD 2.9 billion of incremental volume to the liquid cooling market.

Meta's layout in the ASIC chip field is equally aggressive, with a target of 1 million to 1.5 million units shipped between the end of 2025 and 2026, and its chip area and computing density are approaching NVIDIA's GB200 level in all respects. Combining the demand data of NVIDIA and Google, the global liquid cooling system market space in 2026 is expected to be between USD 9.3 billion and USD 12.6 billion. Corresponding to upstream components, the annual market demand for CDU liquid cooling pumps will remain stable in the range of USD 1.139 billion to USD 1.544 billion. In this highly promising track, apart from a small number of centralized CDUs that still use Grundfos AC large pumps, enterprises at home and abroad that specialize in developing long-durability liquid cooling pumps for data center environments remain extremely scarce.

III. Technical selection parameters and material compatibility bottlenecks

Liquid cooling pump selection involves rigorous calibration of three core indicators: flow rate, head, and efficiency. Flow demand must fully match the total thermal load, usually calculated precisely by dividing the total thermal load by the product of coolant density, specific heat capacity and temperature difference. For example, a 200kW thermal load in a 10 degrees Celsius temperature difference environment requires about 5 cubic metres per hour of flow to ensure the cooling effect. Head represents the pump's ability to overcome pipeline resistance; the calculation must include local resistance generated by valves, cold plates and immersion tanks, and usually reserves a 10% to 20% safety margin. Insufficient head will cause flow attenuation at remote equipment, while over-designed head will cause pointless loss of electrical energy.

In terms of efficiency and reliability, pumps using brushless motors or magnetic suspension bearings show clear advantages, with operating efficiency reaching above 70%, and energy savings of up to 30% compared with traditional industrial pumps. Considering the uninterrupted operation characteristics of data centers, the pump must support N+1 redundancy, that is, when the main pump fails, the backup pump must complete seamless switching within 15 seconds, and the mean time between failures must be no less than 50,000 hours.

The chemical compatibility of materials is likewise part of the technical barrier. For traditional water cooling systems, impellers and housings usually use 304 or 316 stainless steel and copper alloys; for immersion fluorinated liquid or oil cooling systems, nickel-based alloys or special coatings must be used, together with fluororubber or PTFE seals, to prevent the seals from swelling or aging.

IV. Value restructuring and scale of the cold source side industry chain

If the liquid cooling pump is the system's 'power heart', then the primary-side cold source is the 'core energy supply station' responsible for generating cooling capacity. The main function of the cold source side is to completely transfer heat away from the cooling medium, ensuring that the return liquid remains continuously at a low temperature. This link is mainly composed of mechanical refrigeration systems and free cooling systems. Mechanical refrigeration includes air-cooled chilled water and water-cooled chilled water schemes, capable of providing chilled water at 12 to 18 degrees Celsius. Free cooling uses the physical cold of outdoor air, and when meteorological conditions permit, achieves supply water above 30 degrees Celsius through cooling towers or dry coolers.

According to QYresearch statistics, the global market revenue for data center chillers in 2024 was about RMB 105.21 billion, and is expected to climb to RMB 167.33 billion by 2031, with a compound annual growth rate of about 6.7%. In 2024, global annual output of such units was 128,700 units, with the average unit price maintained at a high level of USD 113,000. As the absolute core of the chiller, the refrigeration compressor accounts for more than 50% of the cost of the whole machine and is the main power-consuming unit of the system. As data center single-rack power crosses the 50kW threshold, the refrigeration architecture is undergoing an evolution from screw compressors to magnetic levitation centrifugal compressors; the latter, with higher refrigeration efficiency and lower energy consumption, can achieve a breakthrough of more than 40% energy savings compared with screw machines.

V. Operating principles and segmented competition of refrigeration systems

Refrigeration compressors move heat through the phase change process of the refrigerant. Their working logic is as follows: the compressor draws in gaseous refrigerant from the evaporator, raises its pressure and temperature, and discharges it into the condenser to release heat and condense; the liquefied refrigerant is depressurized through a throttle valve, enters the evaporator to absorb heat and boil, thereby carrying away the heat of the circulating medium and turning back into vapor. At present, the market has formed a clear segmentation pattern: rotary and piston types dominate low-power household scenarios, scroll types mainly occupy the light commercial market, and large industrial and special commercial scenarios are the domain of centrifugal compressors.

The choice of free cooling scheme depends heavily on geographical climate and water resource conditions. In water-scarce areas with low ambient temperatures, dry coolers become the first choice due to the advantages of having no compressor, extremely low power consumption and small initial investment; they cool through the interaction of liquid inside the tubes and natural wind outside the tubes. In areas with abundant water resources, closed or open cooling towers are more common, using the latent heat of water evaporation to carry away heat. For heavy-load data centers in hot and humid areas, a combined cooling mode of chillers and cooling towers is usually required; this structure has extremely strong adaptability but consumes a large amount of water. In this link of the industry chain, foreign brands such as Johnson Controls and Carrier are engaged in fierce market competition with leading domestic enterprises such as Haier, Gree and Ice Wheel Environment.

VI. Business breakthroughs and practical applications of key manufacturers

Feilong Auto Parts, as a domestic manufacturing champion in the water pump field, has now completed the development of liquid cooling pumps covering the full power range from 16W to 22kW in the information and communication field. Its Hangyi HydroCool series products have achieved comprehensive adaptation to the heat dissipation needs of mainstream chips such as Huawei Ascend 910B and C series as well as NVIDIA GB200, and can support CDU heat rejection power requirements from 24kW to 2.5MW. In December 2025, the company successfully held a batch delivery ceremony for the HP22K liquid cooling circulation pump, and the products have been officially shipped to global partners. In 2024 the company achieved operating revenue of RMB 4.723 billion, with net profit attributable to the parent reaching RMB 330 million, demonstrating profit elasticity in its transformation toward the thermal management business.

Ice Wheel Environment, through its subsidiaries Dunham-Bush and Ice Wheel Heat Exchange Technology Company, provides data centers with a one-stop cold source solution from compressors and condensers to heat exchange devices. Dunham-Bush has deep historical accumulation in the field of centrifugal compressors, having produced its first related product as early as 1965, and successfully launched a magnetic levitation compressor in 2014. At present its products have been operating stably in multiple heavyweight projects such as Alibaba Jiangsu Cloud Data Center, China Telecom Jiangxi Computing Center and the National Supercomputing Center in Guangzhou. Ice Wheel Heat Exchange Technology Company is responsible for providing supporting equipment such as closed cooling towers, dry coolers and plate-fin heat exchangers, and is currently actively expanding its global market share through overseas manufacturing bases.

VII. Industry summary and risks

Liquid cooling industrialization has officially entered a key node of volume ramp, and the core rule behind it is the mandatory iteration of thermal infrastructure driven by rising computing density. CDU liquid cooling pumps and chillers, as the most technically demanding power and heat exchange links in the thermal management system, will continue to benefit from the full rollout of NVIDIA architectures and the construction momentum of domestic computing platforms.

But we still need to pay attention to multiple potential fluctuations. If the progress of liquid cooling technology in subsequent iterations falls short of expectations, it may trigger a shift in the timing of industrialization. Macroeconomic fluctuations may also affect the overall construction pace of data centers. In addition, whether the earnings delivery capability of the relevant targets can match the current high valuation expectations remains a core risk that the secondary market needs to assess prudently.

The above is for reference only.

The author of this article may add content!

## Full text (original)

关于报告的所有内容，请于公众『市场分析报告』阅读原文
《数据中心散热深度报告：液冷升级+CDU泵+制冷系统，最具确定性的2家公司》
英伟达单芯片功耗已从B200时代的1000W水平，迅速向2026年量产的R200架构2300W进发，甚至在2027年规划的R300中可能突破4000W大关。当单机柜功率密度跨过50kW这一分水岭，传统的风冷模式已完全无法承载瞬时的高热负荷，液冷系统正由可选技术路线的备选方案，成长为算力基建中的刚性开支。
本次梳理主要聚焦于液冷温控产业链中的两大核心增量：作为二次侧循环“心脏”的CDU液冷泵，以及负责一次侧冷源产生与转移的制冷系统，详尽拆解了从组件价值量、技术参数选型到头部厂商业务进度的每一个细节。
一、液冷泵在循环体系中的核心枢纽作用
在整个液冷循环链路中，CDU（冷部分配单元）扮演着控制中枢的角色，液冷泵则是这个中枢内部最关键的动力组件。其工作原理是通过精密的流体动力学机制，驱动冷却液在封闭的管路中实现强制对流，构建起一套高效的热交换体系。在实际部署中，液冷泵集群通常集成在主机房的CDU机柜内，通过高密度聚乙烯管路将冷却介质输送至服务器前端。冷却液在经过CPU水冷板和内存散热模组等末端装置后，会带走计算核心产生的热负荷并返回主机房，最终形成“冷却液-热源-冷却塔”的闭合传递回路。
泵在这一过程中的核心任务是调节冷却液的流量与系统压力。泵能够根据芯片的实时发热情况进行流量的精准投放，当设备处于高负荷运算状态并产生剧烈热量时，泵会迅速增加流速以带走高温；在低负荷期间则适度下调，以避免不必要的能源浪费。
在压力调节方面，泵必须确保流体在系统内稳定流动，避免因压差过大导致的管路故障或流量分配不均产生的局部过热风险。目前，CDU占据了整个液冷系统价值量的30%至40%，而液冷泵在CDU内部的价值占比达到了35%之多。
二、英伟达与大厂订单驱动的市场规模
算力芯片的放量直接决定了液冷组件的市场天花板。英伟达在2025年披露，截至2026年的五个季度内，其Blackwell和Rubin架构的GPU订单总量约为1400万颗。基于这一订单规模进行测算，2026年英伟达机柜液冷系统的市场份额在保守与乐观情境下分别有望达到69亿美元和97亿美元。同时，谷歌旗下的TPUv7机柜液冷系统表现出极高的价值属性，单机柜价值量在7万至8万美元之间，对应单芯片的散热配套成本约为1094至1250美元。预计2026年谷歌相关等级芯片的出货量将达到220万至230万颗，从而为液冷市场贡献约24亿至29亿美元的增量。
Meta在ASIC芯片领域的布局同样激进，其目标是在2025年底至2026年实现100万至150万件的出货，其芯片面积与计算密度正在全方位逼近英伟达GB200的水平。综合英伟达与谷歌的需求数据，2026年全球液冷系统的市场空间预计在93亿至126亿美元之间。对应到上游组件，CDU液冷泵的年度市场需求将稳定在11.39亿至15.44亿美元的区间内。在这个充满潜力的赛道中，目前除了少部分集中式CDU还在采用格兰富的交流大泵外，国内外专业为数据中心环境开发长耐久液冷泵的企业仍处于极其稀缺的状态。
三、技术选型参数与材料兼容性瓶颈
液冷泵的选型涉及流量、扬程与效率三大核心指标的严密校准。流量需求必须与总热负荷完全匹配，通常采用总热负荷除以冷却液密度、比热容及温差乘积的公式进行精确计算。比如一个200kW的热负荷在10摄氏度温差的环境下，需要约每小时5立方米的流量才能确保散热效果。扬程则代表了泵克服管路阻力的能力，计算过程中必须计入阀门、冷板及浸没槽产生的局部阻力，并通常预留10%至20%的安全裕量。扬程不足会导致远端设备的流量衰减，而过度设计的扬程则会造成电能的无端损耗。
在效率与可靠性方面，采用无刷电机或磁悬浮轴承的泵表现出明显的优势，其运行效率可达70%以上，相比传统工业泵节能效果高达30%。考虑到数据中心不间断运行的特性，泵必须支持N+1冗余，即主泵发生故障时，备用泵需在15秒内完成无缝切换，且平均无故障时间要求不少于50000小时。
材质的化学兼容性同样是技术壁垒的一部分。对于传统水冷系统，叶轮和壳体通常采用304或316不锈钢及铜合金；而对于浸没式氟化液或油冷系统，则必须使用镍基合金或特种涂层材料，并配套氟橡胶或聚四氟乙烯密封件，以防止密封件发生溶胀或老化。
四、冷源侧产业链的价值重构与规模
如果说液冷泵是系统的“动力心脏”，那么一次侧冷源则是负责冷却能力产生的“核心供能站”。冷源侧的主要职能是将热量从冷却介质中彻底转移出去，确保回流液持续处于低温状态。这一环节主要由机械制冷系统与自然冷却系统构成。机械制冷包括风冷冷冻水与水冷冷冻水方案，能提供12至18摄氏度的冷冻水。自然冷却则利用室外空气的物理冷量，在气象条件允许时通过冷却塔或干冷器实现30摄氏度以上的供水。
根据QYresearch统计数据，2024年全球数据中心用冷水机组的市场收入规模约为1052.1亿元，预计到2031年将攀升至1673.3亿元，年复合增长率约为6.7%。2024年全球此类机组的年产量为12.87万台，平均单台价格维持在11.3万美元的高位。制冷压缩机作为冷水机组的绝对核心，其成本占据了整机的50%以上，且是系统主要的耗电单元。随着数据中心单机柜功率跨越50kW的关口，制冷架构正经历从螺杆式压缩机向磁悬浮离心式压缩机的演进，后者凭借更高的制冷效率和更低的能耗，能够实现比螺杆机节能40%以上的突破。
五、制冷系统的运作原理与分类竞争
制冷压缩机通过制冷剂的相变过程实现热量搬移。其工作逻辑表现为：压缩机抽吸来自蒸发器的气态制冷剂，提升压力与温度后排入冷凝器放热冷凝；液化后的制冷剂通过节流阀降压，进入蒸发器吸热沸腾，从而带走循环介质的热量并重新变为蒸气。目前市场已形成明显的细分格局：转子式和活塞式主导家用低功率场景，涡旋式主要占据轻型商用市场，而大型工业及特种商业场景则是离心式压缩机的天下。
自然冷却方案的选择则高度依赖地理气候与水资源条件。在环境温度较低的缺水地区，干冷器凭借没有压缩机、耗电极低及初投资成本小的优势成为首选，它是通过管内走液与管外自然风的交互进行冷却。在水资源充裕的地区，闭式或开式冷却塔则更为普及，它们利用水的蒸发潜热带走热量。对于高热高湿地区的重载数据中心，通常需要冷水机组与冷却塔的联合供冷模式，这种结构具备极强的适应性，但耗水量较大。在这一产业链环节，江森自控、开利等外资品牌与海尔、格力、冰轮环境等国内头部企业正在展开激烈的市场角逐。
六、重点厂商的业务突破与实战应用
飞龙股份作为国内水泵领域的制造业冠军，目前已在信息通信领域完成了覆盖16W至22kW全功率段的液冷泵开发。其航逸HydroCool系列产品已实现对华为昇腾910B、C系列以及英伟达GB200等主流芯片散热需求的全面适配，可支持24kW至2.5MW的CDU解热功率需求。2025年12月，公司成功举行了HP22K液冷循环泵的批量交付仪式，产品已正式发运至全球合作伙伴手中。2024年公司实现了47.23亿元的营业收入，归母净利润达到3.30亿元，展现了在散热业务转型中的盈利弹性。
冰轮环境则通过旗下的顿汉布什和冰轮换热技术公司，为数据中心提供从压缩机、冷凝器到热交换装置的一站式冷源方案。顿汉布什在离心式压缩机领域拥有深厚的历史积淀，早在1965年便产出第一台相关产品，并于2014年成功推出磁悬浮压缩机。目前其产品已在阿里巴巴江苏云数据中心、中国电信江西计算中心及国家超级计算广州中心等多个重量级项目中稳定运行。冰轮换热技术公司则负责提供闭式冷却塔、干冷器及板翅式热交换器等配套装备，目前正积极通过海外制造基地扩张其全球市场份额。
七、行业总结与风险
液冷产业化已正式进入放量的关键节点，其背后的核心规律是算力密度提升对散热基建的强制性迭代。CDU液冷泵与冷水机组作为散热系统中最具技术含量的动力与换热环节，将持续受益于英伟达架构的全面铺开与国产算力平台的建设热度。
但咱们仍需关注多重潜在波动。液冷技术若在后续迭代中进度不及预期，可能引发产业化时间点的位移。宏观经济波动也可能对数据中心的整体建设节奏产生影响。此外，相关标的的业绩兑现能力是否能匹配目前的高估值预期，仍是二级市场需要审慎评估的核心风险。
以上，仅供参考。
本文作者可以追加内容哦 !